{"id":5189,"date":"2026-01-27T09:44:37","date_gmt":"2026-01-27T01:44:37","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=5189"},"modified":"2026-01-27T09:45:46","modified_gmt":"2026-01-27T01:45:46","slug":"halogen-free-mining-why-ntscgewou-fr-cables-are-becoming-mandatory-in-tunnel-projects","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/halogen-free-mining-why-ntscgewou-fr-cables-are-becoming-mandatory-in-tunnel-projects\/","title":{"rendered":"Halogen-Free Mining: Why (N)TSCGEW\u00d6U-FR Cables are Becoming Mandatory in Tunnel Projects"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>The Global Shift Toward Low Smoke Zero Halogen Flame Retardant Cables for Underground Safety<\/strong>&nbsp;\u5168\u7403\u5411\u4f4e\u70df\u65e0\u5364\u963b\u71c3\u7535\u7f06\u8f6c\u53d8\u4ee5\u4fdd\u969c\u5730\u4e0b\u5b89\u5168<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"496173\" data-has-transparency=\"false\" style=\"--dominant-color: #496173;\" loading=\"lazy\" decoding=\"async\" width=\"1051\" height=\"609\" sizes=\"auto, (max-width: 1051px) 100vw, 1051px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-628.avif\" alt=\"\" class=\"wp-image-5190 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-628.avif 1051w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-628-300x174.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-628-768x445.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-628-400x232.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-628-800x464.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-628-832x482.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"Why halogen-free flame retardant (N)TSCGEW\u00d6U-FR cables are becoming mandatory in tunnel projects - safety, regulations, and technical standards - Anhui Feichun Special Cable Co., Ltd.\">\n    <meta name=\"keywords\" content=\"halogen free cable, LSZH cable, tunnel cable requirements, flame retardant cable, MSHA mining, low smoke zero halogen, NTSCGEWOU-FR\">\n    <title>Halogen-Free Mining: Why (N)TSCGEW\u00d6U-FR Cables are Mandatory in Tunnel Projects | Feichun Cables<\/title>\n    <style>\n        * {\n            margin: 0;\n            padding: 0;\n            box-sizing: border-box;\n        }\n\n        body {\n            font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n            line-height: 1.8;\n            max-width: 100%;\n            padding: 20px;\n        }\n\n        @media (min-width: 768px) {\n            body {\n                padding: 40px 60px;\n            }\n        }\n\n        header {\n            padding-bottom: 30px;\n            margin-bottom: 40px;\n            border-bottom: 2px solid;\n        }\n\n        h1 {\n            font-size: 2em;\n            margin-bottom: 15px;\n            font-weight: 700;\n        }\n\n        h2 {\n            font-size: 1.5em;\n            margin-top: 40px;\n            margin-bottom: 20px;\n            font-weight: 600;\n        }\n\n        h3 {\n            font-size: 1.2em;\n            margin-top: 30px;\n            margin-bottom: 15px;\n            font-weight: 600;\n        }\n\n        p {\n            margin-bottom: 20px;\n        }\n\n        .bilingual {\n            font-size: 0.9em;\n            opacity: 0.85;\n            margin-left: 10px;\n        }\n\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            margin: 30px 0;\n            font-size: 0.95em;\n        }\n\n        th, td {\n            padding: 12px 15px;\n            text-align: left;\n            border: 1px solid;\n        }\n\n        th {\n            font-weight: 600;\n        }\n\n        tbody tr:nth-child(even) {\n            opacity: 0.95;\n        }\n\n        .company-info {\n            margin-top: 50px;\n            padding: 25px;\n            border-radius: 8px;\n            border: 1px solid;\n        }\n\n        .contact-info {\n            margin-top: 15px;\n        }\n\n        .contact-info a {\n            display: inline-block;\n            margin-right: 20px;\n            margin-bottom: 10px;\n            text-decoration: none;\n        }\n\n        .reference {\n            font-size: 0.85em;\n            margin-top: 5px;\n            opacity: 0.8;\n        }\n\n        .spec-list {\n            margin: 20px 0 20px 25px;\n        }\n\n        .spec-list li {\n            margin-bottom: 10px;\n        }\n\n        sup {\n            font-size: 0.75em;\n        }\n\n        footer {\n            margin-top: 60px;\n            padding-top: 30px;\n            border-top: 1px solid;\n            font-size: 0.9em;\n            opacity: 0.8;\n        }\n\n        .warning-box {\n            margin: 25px 0;\n            padding: 20px;\n            border-radius: 6px;\n            border: 2px solid;\n        }\n\n        .comparison-box {\n            margin: 25px 0;\n            padding: 20px;\n            border-radius: 6px;\n            border: 1px solid;\n        }\n\n        \/* Light\/Dark mode compatibility *\/\n        @media (prefers-color-scheme: light) {\n            body {\n                background-color: #ffffff;\n                color: #1a1a1a;\n            }\n            header {\n                border-bottom-color: #d0d0d0;\n            }\n            th, td {\n                border-color: #d0d0d0;\n            }\n            .company-info, .comparison-box {\n                background-color: #f8f8f8;\n                border-color: #d0d0d0;\n            }\n            .warning-box {\n                background-color: #fff8f0;\n                border-color: #ff9800;\n            }\n            footer {\n                border-top-color: #d0d0d0;\n            }\n            a {\n                color: #0066cc;\n            }\n            a:hover {\n                color: #0052a3;\n            }\n        }\n\n        @media (prefers-color-scheme: dark) {\n            body {\n                background-color: #1a1a1a;\n                color: #e0e0e0;\n            }\n            header {\n                border-bottom-color: #404040;\n            }\n            th, td {\n                border-color: #404040;\n            }\n            tbody tr:nth-child(even) {\n                background-color: rgba(255, 255, 255, 0.03);\n            }\n            .company-info, .comparison-box {\n                background-color: #242424;\n                border-color: #404040;\n            }\n            .warning-box {\n                background-color: #2a2416;\n                border-color: #cc7a00;\n            }\n            footer {\n                border-top-color: #404040;\n            }\n            a {\n                color: #4d9fff;\n            }\n            a:hover {\n                color: #6bb3ff;\n            }\n        }\n    <\/style>\n<\/head>\n<body>\n    <header>\n        <h1>Halogen-Free Mining: Why (N)TSCGEW\u00d6U-FR Cables are Becoming Mandatory in Tunnel Projects<\/h1>\n        <p><strong>The Global Shift Toward Low Smoke Zero Halogen Flame Retardant Cables for Underground Safety<\/strong> <span class=\"bilingual\">\u5168\u7403\u5411\u4f4e\u70df\u65e0\u5364\u963b\u71c3\u7535\u7f06\u8f6c\u53d8\u4ee5\u4fdd\u969c\u5730\u4e0b\u5b89\u5168<\/span><\/p>\n        <p><em>Anhui Feichun Special Cable Co., Ltd.<\/em> <span class=\"bilingual\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span><\/p>\n    <\/header>\n\n    <main>\n        <section>\n            <h2>1. Understanding Halogen-Free Flame Retardant Technology <span class=\"bilingual\">\u4e86\u89e3\u65e0\u5364\u963b\u71c3\u6280\u672f<\/span><\/h2>\n            \n            <p>Over the past two decades, the cable industry has witnessed a fundamental transformation in safety requirements for confined space installations, particularly in tunnels, underground transit systems, and mining operations. At the center of this evolution lies the shift from traditional halogenated flame retardant cables to halogen-free, low-smoke alternatives. This technological transition represents more than just a materials change\u2014it reflects a deeper understanding of fire safety dynamics and the true risks that cable fires pose to human life, critical infrastructure, and emergency response operations.<sup>1<\/sup><\/p>\n            \n            <p class=\"bilingual\">\u5728\u8fc7\u53bb\u7684\u4e8c\u5341\u5e74\u4e2d\uff0c\u7535\u7f06\u884c\u4e1a\u5728\u5bc6\u95ed\u7a7a\u95f4\u5b89\u88c5\uff08\u7279\u522b\u662f\u96a7\u9053\u3001\u5730\u4e0b\u4ea4\u901a\u7cfb\u7edf\u548c\u91c7\u77ff\u4f5c\u4e1a\uff09\u7684\u5b89\u5168\u8981\u6c42\u65b9\u9762\u53d1\u751f\u4e86\u6839\u672c\u6027\u7684\u8f6c\u53d8\u3002\u8fd9\u4e00\u6f14\u53d8\u7684\u6838\u5fc3\u662f\u4ece\u4f20\u7edf\u7684\u5364\u5316\u963b\u71c3\u7535\u7f06\u5411\u65e0\u5364\u3001\u4f4e\u70df\u66ff\u4ee3\u54c1\u7684\u8f6c\u53d8\u3002<\/p>\n\n            <p>Halogens, defined as Group 17 elements in the periodic table, include fluorine, chlorine, bromine, and iodine. These elements have been widely used in cable manufacturing because they provide excellent flame retardant properties when incorporated into insulation and jacketing materials. Polyvinyl chloride, commonly known as PVC, contains chlorine and has dominated cable construction for decades due to its favorable electrical properties, mechanical durability, and inherent flame resistance. Chloroprene rubber also contains chlorine, while some high-temperature cable materials incorporate fluorine-based polymers such as FEP, PTFE, and ETFE. Bromine-based flame retardant additives are frequently added to enhance fire resistance in various cable compounds.<sup>2<\/sup><\/p>\n\n            <p>However, the very properties that make halogens effective flame retardants become catastrophically dangerous when these materials burn. When halogenated cables are exposed to fire or high temperatures, the halogens undergo combustion reactions that produce halogen acids\u2014specifically hydrochloric acid from chlorine, hydrofluoric acid from fluorine, and hydrobromic acid from bromine. These acids form when halogen gases combine with hydrogen and subsequently react with moisture, whether from the air, firefighting water, or human respiratory systems. The resulting toxic and corrosive fumes create a dual threat: immediate danger to anyone attempting evacuation or rescue, and long-term damage to sensitive electronic equipment, structural reinforcement materials, and building systems.<sup>3<\/sup><\/p>\n\n            <div class=\"warning-box\">\n                <h3>The Hidden Danger of Halogenated Cable Fires <span class=\"bilingual\">\u5364\u5316\u7535\u7f06\u706b\u707e\u7684\u9690\u85cf\u5371\u9669<\/span><\/h3>\n                <p>In tunnel and underground fires involving traditional PVC cables, research has demonstrated that the smoke produced can block more than seventy percent of light transmission, reducing visibility to less than five meters during active fires. This optical density makes evacuation nearly impossible and severely hampers firefighting efforts. Simultaneously, the concentration of toxic gases can reach levels exceeding safe exposure limits within minutes, with corrosive acid vapors causing chemical burns to respiratory tract tissues and eyes even at distances far from the actual fire source.<sup>4<\/sup><\/p>\n            <\/div>\n\n            <p class=\"reference\">[1] HELUKABEL. (2025). Flame Retardancy of Halogen-Free Cables. Retrieved from <a href=\"https:\/\/www.helukabel.us\/us-en\/newsroom\/item\/flame-resistance-halogen-free-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.helukabel.us\/newsroom\/flame-resistance-halogen-free-cables<\/a><\/p>\n\n            <p class=\"reference\">[2] Transfer Multisort Elektronik. (2023). Halogen-free Cables and the Related Regulations. Retrieved from <a href=\"https:\/\/www.tme.com\/us\/en-us\/news\/about-product\/page\/54075\/halogen-free-cables-and-the-related-regulations\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.tme.com\/us\/halogen-free-cables-regulations<\/a><\/p>\n\n            <p class=\"reference\">[3] SAB Cable. (2025). In Case of Fire, Choose the Most Protective Halogen-Free Cable. Retrieved from <a href=\"https:\/\/sabcable.com\/resources\/cable-technology-blog\/in-case-of-fire-choose-the-most-protective-halogen-free-cable\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/sabcable.com\/resources\/halogen-free-cable<\/a><\/p>\n\n            <p class=\"reference\">[4] CB Cables. (2025). When to Use Low Smoke Zero Halogen Cables. Retrieved from <a href=\"https:\/\/www.cbcables.com\/blog\/when-to-use-low-smoke-zero-halogen-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.cbcables.com\/blog\/when-to-use-lszh-cables<\/a><\/p>\n\n            <h3>1.1 What Makes a Cable Truly Halogen-Free <span class=\"bilingual\">\u4ec0\u4e48\u4f7f\u7535\u7f06\u771f\u6b63\u65e0\u5364<\/span><\/h3>\n\n            <p>The term &#8220;halogen-free&#8221; has specific technical definitions established by international standards organizations. According to IEC 61249-2-21, the authoritative international standard for halogen-free materials, a cable component can be classified as halogen-free only when the halogen content of each individual element (fluorine, chlorine, bromine, and iodine) does not exceed nine hundred parts per million by weight, with the total halogen content not exceeding fifteen hundred parts per million. This stringent threshold ensures that even when the material undergoes combustion, the amount of halogen acid gases produced remains below dangerous levels.<sup>5<\/sup><\/p>\n\n            <p class=\"bilingual\">\u6839\u636eIEC 61249-2-21\uff08\u65e0\u5364\u6750\u6599\u7684\u6743\u5a01\u56fd\u9645\u6807\u51c6\uff09\uff0c\u53ea\u6709\u5f53\u6bcf\u4e2a\u5355\u72ec\u5143\u7d20\uff08\u6c1f\u3001\u6c2f\u3001\u6eb4\u548c\u7898\uff09\u7684\u5364\u7d20\u542b\u91cf\u4e0d\u8d85\u8fc7\u767e\u4e07\u5206\u4e4b\u4e5d\u767e\uff08\u6309\u91cd\u91cf\u8ba1\uff09\uff0c\u4e14\u603b\u5364\u7d20\u542b\u91cf\u4e0d\u8d85\u8fc7\u767e\u4e07\u5206\u4e4b\u4e00\u5343\u4e94\u767e\u65f6\uff0c\u7535\u7f06\u7ec4\u4ef6\u624d\u80fd\u88ab\u5f52\u7c7b\u4e3a\u65e0\u5364\u3002<\/p>\n\n            <p>Additional testing standards verify halogen-free performance through combustion analysis. DIN EN 60754-1 and VDE 0482-754-1 establish test procedures for measuring the total acidity of gases evolved during cable combustion, with materials required to produce less than five milligrams of halogen acid per gram of material to achieve halogen-free certification. Complementary testing under DIN EN 60754-2 and VDE 0482-754-2 measures the pH value and electrical conductivity of aqueous solutions containing combustion gases, with pH values required to be above 4.3 and conductivity below ten microsiemens per millimeter to confirm low acid gas production.<sup>6<\/sup><\/p>\n\n            <p>Modern halogen-free cables achieve flame retardancy through alternative chemistry based on thermoplastic and thermoset polyolefin compounds. These materials incorporate aluminum trihydrate or magnesium hydroxide as flame retardant fillers, which decompose endothermically when exposed to heat, absorbing thermal energy and releasing water vapor that dilutes combustible gases and cools the flame zone. Cross-linked polyethylene, ethylene-vinyl acetate copolymers, and thermoplastic elastomers form the polymer matrix, providing the necessary electrical insulation and mechanical properties while remaining free of halogen elements.<sup>7<\/sup><\/p>\n\n            <table>\n                <caption><strong>Table 1: Comparison of Halogenated vs. Halogen-Free Cable Properties During Fire<\/strong> <span class=\"bilingual\">\u5364\u5316\u4e0e\u65e0\u5364\u7535\u7f06\u5728\u706b\u707e\u671f\u95f4\u7684\u6027\u80fd\u6bd4\u8f83<\/span><\/caption>\n                <thead>\n                    <tr>\n                        <th>Property <span class=\"bilingual\">\u6027\u80fd<\/span><\/th>\n                        <th>Traditional PVC\/Halogenated <span class=\"bilingual\">\u4f20\u7edfPVC\/\u5364\u5316<\/span><\/th>\n                        <th>Halogen-Free LSZH <span class=\"bilingual\">\u65e0\u5364LSZH<\/span><\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td>Smoke Opacity<\/td>\n                        <td>&gt;70% light blockage<\/td>\n                        <td>&lt;20% light blockage (\u226580% transmittance)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Toxic Gas Production<\/td>\n                        <td>High (HCl, HBr, HF acids)<\/td>\n                        <td>Minimal (&lt;50 ppm toxic compounds)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Corrosive Gas Release<\/td>\n                        <td>&gt;100 mg\/g hydrogen chloride<\/td>\n                        <td>&lt;5 mg\/g halogen acid content<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>pH of Combustion Gases<\/td>\n                        <td>&lt;3.0 (highly acidic)<\/td>\n                        <td>&gt;4.3 (low acidity)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Visibility Range During Fire<\/td>\n                        <td>&lt;5 meters<\/td>\n                        <td>&gt;20 meters<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Equipment Corrosion Risk<\/td>\n                        <td>Severe (damages electronics, metals)<\/td>\n                        <td>Minimal (no acidic corrosion)<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n\n            <p class=\"reference\">[5] Acquis Compliance. (2023). Understanding Halogen-Free Standards: IEC 61249-2-21. Retrieved from <a href=\"https:\/\/www.acquiscompliance.com\/blog\/understanding-halogen-free-standards-iec\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.acquiscompliance.com\/blog\/halogen-free-standards-iec<\/a><\/p>\n\n            <p class=\"reference\">[6] HELUKABEL. (2025). Flame Retardancy of Halogen-Free Cables. Retrieved from <a href=\"https:\/\/www.helukabel.us\/us-en\/newsroom\/item\/flame-resistance-halogen-free-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.helukabel.us\/newsroom\/flame-resistance-halogen-free-cables<\/a><\/p>\n\n            <p class=\"reference\">[7] Frigate AI. (2025). Halogen-Free Cables: Flame-Retardant and Low-Smoke Zero Halogen. Retrieved from <a href=\"https:\/\/frigate.ai\/product\/halogen-free-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/frigate.ai\/product\/halogen-free-cables<\/a><\/p>\n        <\/section>\n\n        <section>\n            <h2>2. Historical Incidents That Drove Regulatory Change <span class=\"bilingual\">\u63a8\u52a8\u76d1\u7ba1\u53d8\u9769\u7684\u5386\u53f2\u4e8b\u4ef6<\/span><\/h2>\n\n            <p>The global movement toward mandatory halogen-free cables in tunnels and confined spaces did not emerge from abstract safety analysis but from tragic real-world incidents that demonstrated the devastating consequences of halogenated cable fires. These catastrophic events fundamentally changed how regulatory bodies, infrastructure operators, and safety engineers approach cable specifications for underground and enclosed environments.<\/p>\n\n            <h3>2.1 The King&#8217;s Cross Fire and London Underground Tragedy <span class=\"bilingual\">\u56fd\u738b\u5341\u5b57\u706b\u707e\u548c\u4f26\u6566\u5730\u94c1\u60b2\u5267<\/span><\/h3>\n\n            <p>On November 18, 1987, a fire at King&#8217;s Cross St. Pancras underground station in London claimed thirty-one lives and injured approximately one hundred people, becoming one of the deadliest peacetime disasters in British history. The fire began beneath a wooden escalator but rapidly intensified due to the combustion of cable insulation materials throughout the station. Post-incident investigation revealed that the dense black smoke produced by burning cables, many of which contained halogenated materials, contributed significantly to the death toll by obscuring escape routes and producing toxic fumes that incapacitated passengers before they could reach safety.<sup>8<\/sup><\/p>\n\n            <p class=\"bilingual\">1987\u5e7411\u670818\u65e5\uff0c\u4f26\u6566\u56fd\u738b\u5341\u5b57\u5723\u6f58\u514b\u62c9\u65af\u5730\u94c1\u7ad9\u53d1\u751f\u706b\u707e\uff0c\u9020\u621031\u4eba\u6b7b\u4ea1\uff0c\u7ea6100\u4eba\u53d7\u4f24\uff0c\u6210\u4e3a\u82f1\u56fd\u5386\u53f2\u4e0a\u6700\u81f4\u547d\u7684\u548c\u5e73\u65f6\u671f\u707e\u96be\u4e4b\u4e00\u3002\u8c03\u67e5\u663e\u793a\uff0c\u71c3\u70e7\u7535\u7f06\u4ea7\u751f\u7684\u6d53\u5bc6\u9ed1\u70df\uff08\u5176\u4e2d\u8bb8\u591a\u542b\u6709\u5364\u5316\u6750\u6599\uff09\u901a\u8fc7\u906e\u853d\u9003\u751f\u8def\u7ebf\u548c\u4ea7\u751f\u6709\u6bd2\u70df\u96fe\u4e25\u91cd\u5f71\u54cd\u4e86\u6b7b\u4ea1\u4eba\u6570\u3002<\/p>\n\n            <p>The formal inquiry that followed this tragedy led to sweeping changes in fire safety standards for underground transit systems worldwide. One key recommendation focused specifically on cable materials, noting that the contribution of wire and cable jacketing to fire propagation and smoke production had been severely underestimated. As a direct consequence, British standards BS 6724 and BS 7211 were strengthened to explicitly recommend or mandate halogen-free cables in public buildings and transportation infrastructure. Today, halogen-containing cables are completely prohibited in all new London Underground projects and National Health Service hospital installations in the United Kingdom.<sup>9<\/sup><\/p>\n\n            <p class=\"reference\">[8] Wikipedia. (2025). Low Smoke Zero Halogen. Retrieved from <a href=\"https:\/\/en.wikipedia.org\/wiki\/Low_smoke_zero_halogen\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/en.wikipedia.org\/wiki\/Low_smoke_zero_halogen<\/a><\/p>\n\n            <p class=\"reference\">[9] TST Cables. (2025). Requirements and Standards for LSZH Cables in Various Countries. Retrieved from <a href=\"https:\/\/www.tstcables.com\/do-you-know-the-requirements-and-standards-for-lszh-cables-in-various-countries-around-the-world\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.tstcables.com\/lszh-cables-requirements-standards<\/a><\/p>\n\n            <h3>2.2 The Washington DC Metro Tunnel Incident <span class=\"bilingual\">\u534e\u76db\u987f\u7279\u533a\u5730\u94c1\u96a7\u9053\u4e8b\u6545<\/span><\/h3>\n\n            <p>A more recent tragedy occurred in January 2015 when an electrical short circuit in a Washington DC Metro subway tunnel caused legacy power cables to ignite, producing noxious smoke and toxic gases. One passenger died from smoke inhalation, and dozens of others required hospitalization for respiratory injuries. The incident investigation determined that the burning cables, which contained halogenated insulation materials, emitted corrosive hydrogen chloride gas and dense smoke that filled the tunnel and subway cars, preventing safe evacuation despite the relatively small scale of the actual fire.<sup>10<\/sup><\/p>\n\n            <p>This disaster prompted Metro maintenance officials to accelerate the long-planned replacement of older power cables with low-halogen or halogen-free alternatives throughout the Washington DC transit system. The incident also influenced transit authorities across North America to reassess their cable specifications, with many municipalities updating standards to require halogen-free construction for all new cable installations in underground environments. The tragedy demonstrated that even in modern transit systems with extensive safety protocols, the choice of cable materials remains a critical factor in passenger protection during fire emergencies.<sup>11<\/sup><\/p>\n\n            <p class=\"reference\">[10] Texcan. (2025). Choosing Appropriate Cables for Transportation Project Design. Retrieved from <a href=\"https:\/\/www.texcan.com\/articles\/technical-news\/choosing-appropriate-cables-for-your-transportation-project-design\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.texcan.com\/articles\/choosing-cables-transportation<\/a><\/p>\n\n            <p class=\"reference\">[11] Texcan. (2025). Choosing Appropriate Cables for Transportation Project Design. Retrieved from <a href=\"https:\/\/www.texcan.com\/articles\/technical-news\/choosing-appropriate-cables-for-your-transportation-project-design\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.texcan.com\/articles\/choosing-cables-transportation<\/a><\/p>\n\n            <h3>2.3 Military and Naval Lessons: HMS Sheffield <span class=\"bilingual\">\u519b\u4e8b\u548c\u6d77\u519b\u6559\u8bad\uff1a\u8c22\u83f2\u5c14\u5fb7\u53f7<\/span><\/h3>\n\n            <p>The adoption of halogen-free cables in military and naval applications was significantly influenced by the 1982 Falklands War incident involving HMS Sheffield. When the British destroyer was struck by an Exocet missile, the resulting fire produced extraordinarily dense black smoke from burning cables and other materials containing halogenated flame retardants. The toxic and corrosive smoke quickly spread throughout the ship, hampering damage control efforts and contributing to the vessel&#8217;s eventual loss. Post-incident analysis revealed that crew members suffered respiratory injuries from the corrosive gases produced by burning PVC-jacketed cables, even in areas distant from the impact zone.<sup>12<\/sup><\/p>\n\n            <p>Following this and similar incidents in confined military environments, defense organizations worldwide began mandating halogen-free cable specifications for naval vessels, submarines, armored vehicles, and aircraft applications. The military sector&#8217;s early adoption of low-smoke, halogen-free technology helped drive materials research and manufacturing capability improvements that eventually made these cables economically viable for commercial tunnel and building applications.<sup>13<\/sup><\/p>\n\n            <p class=\"reference\">[12] Wikipedia. (2025). Low Smoke Zero Halogen. Retrieved from <a href=\"https:\/\/en.wikipedia.org\/wiki\/Low_smoke_zero_halogen\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/en.wikipedia.org\/wiki\/Low_smoke_zero_halogen<\/a><\/p>\n\n            <p class=\"reference\">[13] Cabling Installation &#038; Maintenance. (2025). UL to Industry: Time to Clarify Some Misconceptions. Retrieved from <a href=\"https:\/\/www.cablinginstall.com\/standards\/cabling-standards\/article\/16467729\/ul-to-industry-time-to-clarify-some-misconceptions\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.cablinginstall.com\/standards\/ul-misconceptions<\/a><\/p>\n        <\/section>\n\n        <section>\n            <h2>3. Global Regulatory Framework and Mandatory Requirements <span class=\"bilingual\">\u5168\u7403\u76d1\u7ba1\u6846\u67b6\u548c\u5f3a\u5236\u6027\u8981\u6c42<\/span><\/h2>\n\n            <p>The transition from optional to mandatory halogen-free cable requirements has occurred at different paces across various regions and jurisdictions, but the overall trend is unmistakably toward stricter regulations that eliminate halogenated cables from tunnel, underground transit, and public building applications. Understanding this evolving regulatory landscape is essential for infrastructure developers, mining operators, and cable specifiers working on international projects or planning installations that must remain compliant for decades of operational life.<\/p>\n\n            <h3>3.1 European Union Construction Products Regulation <span class=\"bilingual\">\u6b27\u76df\u5efa\u7b51\u4ea7\u54c1\u6cd5\u89c4<\/span><\/h3>\n\n            <p>The European Union has established the world&#8217;s most comprehensive and stringent framework for halogen-free cable requirements through the Construction Products Regulation, officially designated as EU Regulation 305\/2011. Implemented in 2017, this regulation mandates that all power and communication cables used in permanent building installations must undergo fire classification testing according to EN 50575 standards and bear the CE conformity marking demonstrating compliance with established performance criteria.<sup>14<\/sup><\/p>\n\n            <p class=\"bilingual\">\u6b27\u76df\u901a\u8fc7\u5efa\u7b51\u4ea7\u54c1\u6cd5\u89c4\uff08\u6b63\u5f0f\u540d\u79f0\u4e3aEU 305\/2011\u6cd5\u89c4\uff09\u5efa\u7acb\u4e86\u4e16\u754c\u4e0a\u6700\u5168\u9762\u548c\u6700\u4e25\u683c\u7684\u65e0\u5364\u7535\u7f06\u8981\u6c42\u6846\u67b6\u3002\u8be5\u6cd5\u89c4\u4e8e2017\u5e74\u5b9e\u65bd\uff0c\u8981\u6c42\u6240\u6709\u7528\u4e8e\u6c38\u4e45\u6027\u5efa\u7b51\u5b89\u88c5\u7684\u7535\u529b\u548c\u901a\u4fe1\u7535\u7f06\u90fd\u5fc5\u987b\u6309\u7167EN 50575\u6807\u51c6\u8fdb\u884c\u9632\u706b\u5206\u7c7b\u6d4b\u8bd5\u3002<\/p>\n\n            <p>The EN 50575 classification system categorizes cables into seven performance classes ranging from Aca (highest performance) to Fca (lowest performance), with specific classes designated for different application scenarios. For underground transit systems including subways, metro railways, and vehicular tunnels, European regulations explicitly require cables meeting Cca, Dca, or higher classifications, all of which mandate halogen-free construction to limit smoke production and toxic gas emission. Germany, France, the Netherlands, Sweden, Italy, and other EU member states strictly enforce these CPR low-smoke halogen-free standards, with non-compliant cables prohibited from sale or installation in covered applications.<sup>15<\/sup><\/p>\n\n            <p>Additional European standards provide detailed technical requirements beyond the basic CPR framework. EN 50305 specifies maximum corrosivity levels by requiring combustion product pH values to remain above 4.3, ensuring that acid gas production stays within safe limits even during extended fires. The stringent emphasis on corrosivity testing reflects European infrastructure operators&#8217; concern about protecting sensitive electronic equipment in railway signaling systems, telecommunications facilities, and tunnel ventilation control systems from acid damage that could compromise functionality long after fire suppression.<sup>16<\/sup><\/p>\n\n            <table>\n                <caption><strong>Table 2: Global Halogen-Free Cable Regulatory Requirements by Region<\/strong> <span class=\"bilingual\">\u6309\u5730\u533a\u5212\u5206\u7684\u5168\u7403\u65e0\u5364\u7535\u7f06\u76d1\u7ba1\u8981\u6c42<\/span><\/caption>\n                <thead>\n                    <tr>\n                        <th>Region\/Country <span class=\"bilingual\">\u5730\u533a\/\u56fd\u5bb6<\/span><\/th>\n                        <th>Primary Standards <span class=\"bilingual\">\u4e3b\u8981\u6807\u51c6<\/span><\/th>\n                        <th>Mandatory Applications <span class=\"bilingual\">\u5f3a\u5236\u6027\u5e94\u7528<\/span><\/th>\n                        <th>Implementation Status <span class=\"bilingual\">\u5b9e\u65bd\u72b6\u6001<\/span><\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td>European Union<\/td>\n                        <td>CPR EU 305\/2011, EN 50575, EN 50305<\/td>\n                        <td>Subways, hospitals, schools, high-rises, airports, tunnels<\/td>\n                        <td>Mandatory since 2017, strictly enforced<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>United Kingdom<\/td>\n                        <td>BS 6724, BS 7211<\/td>\n                        <td>London Underground, NHS hospitals, public buildings<\/td>\n                        <td>Halogenated cables completely banned in new projects<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>China<\/td>\n                        <td>GB 31247-2014, GB\/T 19666, GB 50217<\/td>\n                        <td>Subways, high-speed rail, data centers, super high-rises<\/td>\n                        <td>Mandatory 3C certification from July 2025<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>United States<\/td>\n                        <td>NFPA 130, NFPA 101, UL 1685, IEEE 1202<\/td>\n                        <td>Transit systems, confined spaces (project-specific)<\/td>\n                        <td>Not federally mandated, but widely required by authorities<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>Japan<\/td>\n                        <td>JIS C 3665, SONY SS-00259<\/td>\n                        <td>Tokyo Metro, JR East, public transportation<\/td>\n                        <td>Industry self-regulation plus major enterprise requirements<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>South Korea<\/td>\n                        <td>KS C IEC 60754, KS C IEC 61034<\/td>\n                        <td>Seoul Metro, Incheon Airport, semiconductor facilities<\/td>\n                        <td>Mandatory for critical infrastructure<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n\n            <p class=\"reference\">[14] TST Cables. (2025). Requirements and Standards for LSZH Cables in Various Countries. Retrieved from <a href=\"https:\/\/www.tstcables.com\/do-you-know-the-requirements-and-standards-for-lszh-cables-in-various-countries-around-the-world\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.tstcables.com\/lszh-cables-requirements-standards<\/a><\/p>\n\n            <p class=\"reference\">[15] Transfer Multisort Elektronik. (2023). Halogen-free Cables and the Related Regulations. Retrieved from <a href=\"https:\/\/www.tme.com\/us\/en-us\/news\/about-product\/page\/54075\/halogen-free-cables-and-the-related-regulations\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.tme.com\/us\/halogen-free-cables-regulations<\/a><\/p>\n\n            <p class=\"reference\">[16] TST Cables. (2025). Requirements and Standards for LSZH Cables in Various Countries. Retrieved from <a href=\"https:\/\/www.tstcables.com\/do-you-know-the-requirements-and-standards-for-lszh-cables-in-various-countries-around-the-world\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.tstcables.com\/lszh-cables-requirements-standards<\/a><\/p>\n\n            <h3>3.2 Chinese GB Standards and New Certification Requirements <span class=\"bilingual\">\u4e2d\u56fdGB\u6807\u51c6\u548c\u65b0\u8ba4\u8bc1\u8981\u6c42<\/span><\/h3>\n\n            <p>China has implemented comprehensive halogen-free cable standards through the GB (Guobiao or National Standard) system, with recent regulatory updates significantly strengthening enforcement mechanisms. GB 31247-2014 establishes the classification system for flame-retardant and fire-resistant wires and cables, dividing products into A, B, C, and D grades based on performance characteristics. The highest flame-retardant classification, designated B1 grade, explicitly requires cables to demonstrate low smoke properties with light transmittance of at least sixty percent, halogen-free construction with halogen acid gas emission below five milligrams per gram, and low toxicity during combustion.<sup>17<\/sup><\/p>\n\n            <p>The general technical requirements for low-smoke halogen-free cables are specified in GB\/T 19666, which applies across all scenarios within Chinese jurisdiction and establishes baseline performance criteria that all compliant cables must meet. More specific application requirements are mandated by GB 50217, the Code for Design of Power Engineering Cables, which identifies compulsory scenarios where halogen-free cables must be used. These mandatory applications include all subway and metro railway systems such as those in Beijing, Shanghai, Guangzhou, and Shenzhen; high-speed rail installations; data centers and telecommunications facilities; hospitals and medical centers; and super high-rise buildings including landmark structures like the Shenzhen Ping An Finance Center.<sup>18<\/sup><\/p>\n\n            <p>A critical regulatory change takes effect on July 1, 2025, when new Chinese regulations will require all flame-retardant wires and cables to pass mandatory CCC (China Compulsory Certification, also known as 3C certification) before they can be legally sold or installed. Products failing to meet the established standards will be prohibited from the market entirely. This certification requirement ensures that imported and domestically produced cables undergo rigorous testing by accredited laboratories before being approved for use in Chinese infrastructure projects, significantly reducing the risk of substandard or counterfeit products entering the supply chain.<sup>19<\/sup><\/p>\n\n            <p class=\"reference\">[17] CB Cables. (2025). When to Use Low Smoke Zero Halogen Cables. Retrieved from <a href=\"https:\/\/www.cbcables.com\/blog\/when-to-use-low-smoke-zero-halogen-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.cbcables.com\/blog\/when-to-use-lszh-cables<\/a><\/p>\n\n            <p class=\"reference\">[18] CB Cables. (2025). When to Use Low Smoke Zero Halogen Cables. Retrieved from <a href=\"https:\/\/www.cbcables.com\/blog\/when-to-use-low-smoke-zero-halogen-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.cbcables.com\/blog\/when-to-use-lszh-cables<\/a><\/p>\n\n            <p class=\"reference\">[19] TST Cables. (2025). Requirements and Standards for LSZH Cables in Various Countries. Retrieved from <a href=\"https:\/\/www.tstcables.com\/do-you-know-the-requirements-and-standards-for-lszh-cables-in-various-countries-around-the-world\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.tstcables.com\/lszh-cables-requirements-standards<\/a><\/p>\n\n            <h3>3.3 North American Approach: Project-Based Requirements <span class=\"bilingual\">\u5317\u7f8e\u65b9\u6cd5\uff1a\u57fa\u4e8e\u9879\u76ee\u7684\u8981\u6c42<\/span><\/h3>\n\n            <p>Unlike the European Union&#8217;s comprehensive regulatory framework or China&#8217;s national standards system, the United States has not adopted federal mandates requiring halogen-free cables in all tunnel and underground applications. However, this does not mean that American tunnel projects can freely use halogenated cables. Instead, halogen-free requirements are typically imposed through project specifications, transportation authority standards, and recommendations from influential safety organizations like the National Fire Protection Association.<sup>20<\/sup><\/p>\n\n            <p>NFPA 130, the Standard for Fixed Guideway Transit and Passenger Rail Systems, strongly recommends the use of low-smoke, halogen-free materials in confined spaces including subway tunnels, elevated rail systems, and underground stations. Similarly, NFPA 101, the Life Safety Code, provides guidance on cable materials for buildings and structures where limited egress routes make smoke and toxic gas production particularly dangerous. While these NFPA standards are not legally binding federal requirements, they are frequently adopted by state and local authorities having jurisdiction, and many transit agencies reference them directly in procurement specifications.<sup>21<\/sup><\/p>\n\n            <p>Major infrastructure owners and technology companies have independently adopted halogen-free cable requirements as corporate standards. For example, Google and Microsoft explicitly require LSZH cabling in all data center tender documents and construction specifications, recognizing that the equipment protection benefits and improved personnel safety justify any additional material costs. Transit authorities operating major subway systems in cities like New York, Boston, San Francisco, and Chicago have progressively updated specifications to require halogen-free cables for new installations and major renovation projects, even absent federal mandates.<sup>22<\/sup><\/p>\n\n            <p class=\"reference\">[20] Galaxy Wire &#038; Cable. (2025). What Makes a Cable Low Smoke Zero Halogen and When is it Required? Retrieved from <a href=\"https:\/\/www.galaxywire.com\/connections-blog\/what-makes-a-cable-low-smoke-zero-halogen-and-when-is-it-required\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.galaxywire.com\/what-makes-cable-lszh<\/a><\/p>\n\n            <p class=\"reference\">[21] Top Cable. (2025). Fire Resistant Cables vs Halogen-Free Cables. Retrieved from <a href=\"https:\/\/www.topcable.com\/blog-electric-cable\/fire-resistant-halogenfree\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.topcable.com\/blog\/fire-resistant-halogenfree<\/a><\/p>\n\n            <p class=\"reference\">[22] Wesco. (2025). Cable Materials Evolution: The Shift to Halogen Free. Retrieved from <a href=\"https:\/\/www.wesco.com\/us\/en\/knowledge-hub\/articles\/cable-materials-evolution-the-shift-to-halogen-free.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.wesco.com\/knowledge-hub\/cable-materials-halogen-free<\/a><\/p>\n        <\/section>\n\n        <section>\n            <h2>4. Why Tunnels and Mining Operations Require Halogen-Free Cables <span class=\"bilingual\">\u4e3a\u4ec0\u4e48\u96a7\u9053\u548c\u91c7\u77ff\u4f5c\u4e1a\u9700\u8981\u65e0\u5364\u7535\u7f06<\/span><\/h2>\n\n            <p>The physical characteristics of tunnels and underground mining environments create uniquely dangerous conditions during fire emergencies that make halogen-free cables not just preferable but essential for protecting human life and preserving critical infrastructure. Understanding these environmental factors helps explain why regulatory bodies worldwide have prioritized tunnel applications when implementing mandatory halogen-free requirements.<\/p>\n\n            <h3>4.1 Confined Space Smoke Accumulation <span class=\"bilingual\">\u5bc6\u95ed\u7a7a\u95f4\u70df\u96fe\u79ef\u805a<\/span><\/h3>\n\n            <p>Tunnels and underground mining galleries are characterized by limited ventilation and restricted air circulation compared to above-ground structures. During a cable fire, smoke and combustion gases rapidly accumulate in these confined spaces, with no natural escape path to allow toxic fumes to dissipate harmlessly into the atmosphere. Standard tunnel ventilation systems, while designed to provide fresh air during normal operations, often prove inadequate to clear smoke during active fires, particularly when ventilation equipment itself becomes damaged by heat or corrosive gases.<sup>23<\/sup><\/p>\n\n            <p class=\"bilingual\">\u96a7\u9053\u548c\u5730\u4e0b\u77ff\u4e95\u5df7\u9053\u7684\u7279\u70b9\u662f\u4e0e\u5730\u9762\u7ed3\u6784\u76f8\u6bd4\u901a\u98ce\u6709\u9650\u548c\u7a7a\u6c14\u5faa\u73af\u53d7\u9650\u3002\u5728\u7535\u7f06\u706b\u707e\u671f\u95f4\uff0c\u70df\u96fe\u548c\u71c3\u70e7\u6c14\u4f53\u8fc5\u901f\u5728\u8fd9\u4e9b\u5bc6\u95ed\u7a7a\u95f4\u4e2d\u79ef\u805a\uff0c\u6ca1\u6709\u81ea\u7136\u9003\u9038\u8def\u5f84\u5141\u8bb8\u6709\u6bd2\u70df\u96fe\u65e0\u5bb3\u5730\u6d88\u6563\u5230\u5927\u6c14\u4e2d\u3002<\/p>\n\n            <p>Research on smoke behavior in tunnel fires has demonstrated that the smoke layer descends from the ceiling much more rapidly in confined underground environments than in conventional buildings with windows and multiple ventilation openings. When traditional PVC or other halogenated cables burn in a tunnel, the dense black smoke they produce can fill the entire cross-section of the tunnel within minutes, reducing visibility to near zero and making evacuation or rescue operations virtually impossible. In contrast, halogen-free cables produce significantly less smoke with much lower optical density, maintaining light transmittance above eighty percent even during active combustion. This improved visibility can mean the difference between successful evacuation and tragedy in underground emergency scenarios.<sup>24<\/sup><\/p>\n\n            <p class=\"reference\">[23] SAB Cable. (2025). In Case of Fire, Choose the Most Protective Halogen-Free Cable. Retrieved from <a href=\"https:\/\/sabcable.com\/resources\/cable-technology-blog\/in-case-of-fire-choose-the-most-protective-halogen-free-cable\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/sabcable.com\/resources\/halogen-free-cable<\/a><\/p>\n\n            <p class=\"reference\">[24] Remee Products. (2025). Benefits of Low Smoke Zero Halogen Cables. Retrieved from <a href=\"https:\/\/remee.com\/low-smoke-zero-halogen-cable-benefits\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/remee.com\/low-smoke-zero-halogen-cable-benefits<\/a><\/p>\n\n            <h3>4.2 Extended Evacuation Distances and Limited Egress Routes <span class=\"bilingual\">\u5ef6\u957f\u7684\u758f\u6563\u8ddd\u79bb\u548c\u6709\u9650\u7684\u51fa\u53e3\u8def\u7ebf<\/span><\/h3>\n\n            <p>Unlike conventional buildings where occupants are typically within a hundred meters of an exit, tunnel users and mining personnel may be located several kilometers from the nearest safe egress point when a fire begins. Highway tunnels, railway tunnels, and mine shafts often extend for many kilometers with emergency exits spaced at intervals of five hundred to one thousand meters or more. This reality means that evacuation times measured in tens of minutes are normal and expected, rather than the two- to three-minute evacuation windows used in building fire safety calculations.<\/p>\n\n            <p>The extended evacuation timeline makes smoke toxicity and visibility even more critical than in surface structures. Occupants attempting to evacuate through a smoke-filled tunnel for ten or fifteen minutes face cumulative exposure to toxic gases that would be immediately fatal if the cable materials produce high concentrations of hydrogen chloride, hydrogen fluoride, or carbon monoxide. Halogen-free cables address this challenge by limiting toxic gas production to levels below fifty parts per million, allowing human exposure for the extended periods necessary to complete tunnel evacuation without causing irreversible respiratory damage or incapacitation.<sup>25<\/sup><\/p>\n\n            <p>Mining operations present additional complications due to complex tunnel networks with multiple branches, shafts at various elevations, and equipment that may obstruct emergency egress routes. Underground coal mines and metal mines often have limited escape ways that must serve as the only evacuation path for hundreds of workers distributed across kilometers of underground workings. In these environments, cable fires that produce dense smoke or toxic gases can trap miners underground for extended periods while rescue teams attempt to establish safe evacuation routes, making halogen-free cable construction an essential safety measure.<sup>26<\/sup><\/p>\n\n            <p class=\"reference\">[25] Texcan. (2025). Choosing Appropriate Cables for Transportation Project Design. Retrieved from <a href=\"https:\/\/www.texcan.com\/articles\/technical-news\/choosing-appropriate-cables-for-your-transportation-project-design\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.texcan.com\/articles\/choosing-cables-transportation<\/a><\/p>\n\n            <p class=\"reference\">[26] Remee Products. (2025). Benefits of Low Smoke Zero Halogen Cables. Retrieved from <a href=\"https:\/\/remee.com\/low-smoke-zero-halogen-cable-benefits\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/remee.com\/low-smoke-zero-halogen-cable-benefits<\/a><\/p>\n\n            <h3>4.3 Protection of Critical Safety and Control Systems <span class=\"bilingual\">\u4fdd\u62a4\u5173\u952e\u5b89\u5168\u548c\u63a7\u5236\u7cfb\u7edf<\/span><\/h3>\n\n            <p>Modern tunnels and mining operations rely heavily on electronic systems for ventilation control, emergency lighting, communication, fire detection, and emergency response coordination. These systems must remain operational during fire emergencies to support evacuation and firefighting efforts. However, the corrosive acid gases produced when halogenated cables burn can damage or destroy sensitive electronic equipment within minutes of exposure, rendering critical safety systems inoperable precisely when they are most needed.<\/p>\n\n            <div class=\"comparison-box\">\n                <h3>Equipment Damage from Halogenated Cable Fires <span class=\"bilingual\">\u5364\u5316\u7535\u7f06\u706b\u707e\u9020\u6210\u7684\u8bbe\u5907\u635f\u574f<\/span><\/h3>\n                <p>The 1988 AT&#038;T central office fire in Hinsdale, Illinois, provides a well-documented example of corrosive gas damage from burning PVC cables. Although the actual flames affected a relatively small area, hydrogen chloride gas from burning cable insulation spread throughout the facility, forming hydrochloric acid when it contacted moisture in the air conditioning system. This acidic contamination destroyed sensitive switching equipment, printed circuit boards, and electronic components throughout the building, causing damage that took months to repair and cost hundreds of millions of dollars. The incident demonstrated that in fires involving halogenated cables, corrosive gas damage often far exceeds the direct fire and heat damage.<sup>27<\/sup><\/p>\n            <\/div>\n\n            <p>Tunnel ventilation control systems, emergency lighting inverters, fire alarm panels, and communication equipment contain numerous metal components, printed circuit boards, and connector systems vulnerable to acid corrosion. By eliminating halogen content from cable insulation and jacketing materials, halogen-free cables prevent the formation of corrosive acid gases even when exposed to fire, allowing critical systems to continue functioning during emergencies and minimizing post-fire cleanup and restoration costs.<sup>28<\/sup><\/p>\n\n            <p class=\"reference\">[27] Wesco. (2025). Cable Materials Evolution: The Shift to Halogen Free. Retrieved from <a href=\"https:\/\/www.wesco.com\/us\/en\/knowledge-hub\/articles\/cable-materials-evolution-the-shift-to-halogen-free.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.wesco.com\/knowledge-hub\/cable-materials-halogen-free<\/a><\/p>\n\n            <p class=\"reference\">[28] Frigate AI. (2025). Halogen-Free Cables: Flame-Retardant and Low-Smoke Zero Halogen. Retrieved from <a href=\"https:\/\/frigate.ai\/product\/halogen-free-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/frigate.ai\/product\/halogen-free-cables<\/a><\/p>\n        <\/section>\n\n        <section>\n            <h2>5. Technical Standards and Performance Testing <span class=\"bilingual\">\u6280\u672f\u6807\u51c6\u548c\u6027\u80fd\u6d4b\u8bd5<\/span><\/h2>\n\n            <p>Ensuring that cables marketed as halogen-free and low-smoke actually meet safety performance requirements demands rigorous testing according to internationally recognized standards. Cable manufacturers, testing laboratories, and certification bodies employ multiple test methods to verify compliance with halogen content limits, smoke production characteristics, and flame retardant properties.<\/p>\n\n            <h3>5.1 Key International Testing Standards <span class=\"bilingual\">\u5173\u952e\u56fd\u9645\u6d4b\u8bd5\u6807\u51c6<\/span><\/h3>\n\n            <p>The IEC 60754 series of standards establishes test methods for measuring gases evolved during combustion of cable materials. IEC 60754-1 specifies procedures for determining halogen acid gas content through chemical titration, while IEC 60754-2 measures the pH value and electrical conductivity of aqueous solutions containing combustion gases. These tests provide quantitative data on the amount of acidic gases produced when cable insulation burns, verifying that materials meet halogen-free classification criteria.<sup>29<\/sup><\/p>\n\n            <p class=\"bilingual\">IEC 60754\u7cfb\u5217\u6807\u51c6\u5efa\u7acb\u4e86\u6d4b\u91cf\u7535\u7f06\u6750\u6599\u71c3\u70e7\u8fc7\u7a0b\u4e2d\u91ca\u653e\u7684\u6c14\u4f53\u7684\u6d4b\u8bd5\u65b9\u6cd5\u3002IEC 60754-1\u89c4\u5b9a\u4e86\u901a\u8fc7\u5316\u5b66\u6ef4\u5b9a\u6d4b\u5b9a\u5364\u7d20\u9178\u6c14\u542b\u91cf\u7684\u7a0b\u5e8f\uff0c\u800cIEC 60754-2\u6d4b\u91cf\u542b\u6709\u71c3\u70e7\u6c14\u4f53\u7684\u6c34\u6eb6\u6db2\u7684pH\u503c\u548c\u7535\u5bfc\u7387\u3002<\/p>\n\n            <p>Smoke density testing follows procedures outlined in IEC 61034, which measures light transmittance through smoke produced by burning cable samples in a standardized test chamber. Cables are burned under defined conditions, and photometric equipment measures the percentage of light that can pass through the resulting smoke layer. Low-smoke cables must demonstrate light transmittance of at least sixty percent after three minutes of combustion, ensuring that visibility remains adequate for evacuation purposes even when cables are burning.<sup>30<\/sup><\/p>\n\n            <p>Flame retardancy is evaluated using various test methods depending on the cable type and installation configuration. IEC 60332-1 assesses single vertical cable flame propagation, verifying that individual cables are self-extinguishing and will not sustain burning when the ignition source is removed. For cables installed in bundles or on cable trays\u2014the typical configuration in tunnels and mining applications\u2014IEC 60332-3 vertical flame spread testing provides more realistic evaluation of fire behavior, measuring how far flames propagate along a multi-cable sample before self-extinguishing.<sup>31<\/sup><\/p>\n\n            <table>\n                <caption><strong>Table 3: Key Performance Testing Standards for Halogen-Free Cables<\/strong> <span class=\"bilingual\">\u65e0\u5364\u7535\u7f06\u5173\u952e\u6027\u80fd\u6d4b\u8bd5\u6807\u51c6<\/span><\/caption>\n                <thead>\n                    <tr>\n                        <th>Test Standard <span class=\"bilingual\">\u6d4b\u8bd5\u6807\u51c6<\/span><\/th>\n                        <th>Property Measured <span class=\"bilingual\">\u6d4b\u91cf\u5c5e\u6027<\/span><\/th>\n                        <th>Pass Criteria <span class=\"bilingual\">\u901a\u8fc7\u6807\u51c6<\/span><\/th>\n                    <\/tr>\n                <\/thead>\n                <tbody>\n                    <tr>\n                        <td>IEC 60754-1<\/td>\n                        <td>Halogen acid gas content (titration)<\/td>\n                        <td>&lt;5 mg\/g halogen acid<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>IEC 60754-2<\/td>\n                        <td>pH and conductivity of combustion gases<\/td>\n                        <td>pH &gt;4.3, conductivity &lt;10 \u00b5S\/mm<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>IEC 61034<\/td>\n                        <td>Smoke density (light transmittance)<\/td>\n                        <td>&gt;60% light transmittance (typical &gt;80% for LSZH)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>IEC 60332-1<\/td>\n                        <td>Single vertical cable flame propagation<\/td>\n                        <td>Self-extinguishing, limited char length<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>IEC 60332-3<\/td>\n                        <td>Bundled cable vertical flame spread<\/td>\n                        <td>Flame spread &lt;2.5m (Category A), &lt;1.5m (Category C)<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>IEC 62821<\/td>\n                        <td>Complete LSHF cable requirements<\/td>\n                        <td>Combined halogen-free, low smoke, and flame tests<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>UL 1685\/IEEE 1202<\/td>\n                        <td>Vertical tray flame test<\/td>\n                        <td>Limited flame spread in cable tray configuration<\/td>\n                    <\/tr>\n                    <tr>\n                        <td>EN 50575 (CPR)<\/td>\n                        <td>European cable classification<\/td>\n                        <td>Aca to Fca classes based on comprehensive testing<\/td>\n                    <\/tr>\n                <\/tbody>\n            <\/table>\n\n            <p class=\"reference\">[29] UL Solutions. (2025). Halogen Free and Low Smoke Halogen Free Cable Certification. Retrieved from <a href=\"https:\/\/www.ul.com\/services\/halogen-free-hf-and-low-smoke-halogen-free-lshf-cable-certification\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.ul.com\/services\/halogen-free-lshf-cable-certification<\/a><\/p>\n\n            <p class=\"reference\">[30] Teknor Apex. (2025). Flame Retardant Wire and Cable Jacketing Compounds Receive Halogen-Free Assessments from UL. Retrieved from <a href=\"http:\/\/www.teknorapex.com\/en-us\/news\/flame-retardant-wire-and-cable-jacketing-compounds-receive-halogen-free-assessments-from-ul\" rel=\"nofollow noopener\" target=\"_blank\">http:\/\/www.teknorapex.com\/news\/flame-retardant-halogen-free-ul<\/a><\/p>\n\n            <p class=\"reference\">[31] Frigate AI. (2025). Halogen-Free Cables: Flame-Retardant and Low-Smoke Zero Halogen. Retrieved from <a href=\"https:\/\/frigate.ai\/product\/halogen-free-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/frigate.ai\/product\/halogen-free-cables<\/a><\/p>\n\n            <h3>5.2 Certification and Compliance Verification <span class=\"bilingual\">\u8ba4\u8bc1\u548c\u5408\u89c4\u9a8c\u8bc1<\/span><\/h3>\n\n            <p>Third-party certification from recognized testing laboratories provides independent verification that cables meet established halogen-free and low-smoke standards. Organizations such as UL Solutions, Underwriters Laboratories, and various national testing authorities offer optional certification programs specifically for halogen-free and low-smoke halogen-free cables. UL&#8217;s Material Recognition service under UL 2885 standard evaluates individual cable components including insulation compounds, jacket materials, fillers, and tapes for halogen content and combustion performance, while complete cable assembly certification programs verify that finished cables meet all applicable requirements.<sup>32<\/sup><\/p>\n\n            <p>The certification process involves comprehensive testing of cable samples, factory inspections to verify manufacturing quality control systems, and ongoing surveillance testing of production to ensure continued compliance. Certified cables receive distinctive markings or labels that allow purchasers, inspectors, and regulatory authorities to quickly verify compliance. For example, UL-certified halogen-free cables bear optional &#8220;-HF&#8221; surface markings, while cables meeting both halogen-free and low-smoke requirements display &#8220;-LSHF&#8221; markings according to IEC 62821 standards.<sup>33<\/sup><\/p>\n\n            <p class=\"reference\">[32] UL Solutions. (2025). Halogen Free and Low Smoke Halogen Free Cable Certification. Retrieved from <a href=\"https:\/\/www.ul.com\/services\/halogen-free-hf-and-low-smoke-halogen-free-lshf-cable-certification\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.ul.com\/services\/halogen-free-lshf-cable-certification<\/a><\/p>\n\n            <p class=\"reference\">[33] Cabling Installation &#038; Maintenance. (2025). UL to Industry: Time to Clarify Some Misconceptions. Retrieved from <a href=\"https:\/\/www.cablinginstall.com\/standards\/cabling-standards\/article\/16467729\/ul-to-industry-time-to-clarify-some-misconceptions\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.cablinginstall.com\/standards\/ul-misconceptions<\/a><\/p>\n        <\/section>\n\n        <section>\n            <h2>6. Engineering Considerations and Material Trade-offs <span class=\"bilingual\">\u5de5\u7a0b\u8003\u8651\u56e0\u7d20\u548c\u6750\u6599\u6743\u8861<\/span><\/h2>\n\n            <p>While the safety benefits of halogen-free cables are unquestionable in tunnel and underground applications, engineers must understand certain material property differences when transitioning from traditional halogenated cables to halogen-free alternatives. Proper cable selection and installation practices ensure that halogen-free cables deliver reliable long-term performance while maximizing safety advantages.<\/p>\n\n            <h3>6.1 Mechanical Properties and Installation Requirements <span class=\"bilingual\">\u673a\u68b0\u6027\u80fd\u548c\u5b89\u88c5\u8981\u6c42<\/span><\/h3>\n\n            <p>Halogen-free cable compounds contain high percentages of inorganic filler materials such as aluminum trihydrate or magnesium hydroxide that provide flame retardancy through endothermic decomposition. These mineral fillers, while essential for fire performance, can affect mechanical properties compared to traditional PVC formulations. Halogen-free jackets may exhibit slightly reduced flexibility and cold-temperature performance, with some formulations becoming stiff or prone to cracking when installed in very cold environments or subjected to tight bending radii.<sup>34<\/sup><\/p>\n\n            <p class=\"bilingual\">\u65e0\u5364\u7535\u7f06\u5316\u5408\u7269\u542b\u6709\u9ad8\u767e\u5206\u6bd4\u7684\u65e0\u673a\u586b\u6599\u6750\u6599\uff0c\u5982\u6c34\u5408\u6c27\u5316\u94dd\u6216\u6c22\u6c27\u5316\u9541\uff0c\u901a\u8fc7\u5438\u70ed\u5206\u89e3\u63d0\u4f9b\u963b\u71c3\u6027\u3002\u8fd9\u4e9b\u77ff\u7269\u586b\u6599\u867d\u7136\u5bf9\u9632\u706b\u6027\u80fd\u81f3\u5173\u91cd\u8981\uff0c\u4f46\u4e0e\u4f20\u7edfPVC\u914d\u65b9\u76f8\u6bd4\u53ef\u80fd\u5f71\u54cd\u673a\u68b0\u6027\u80fd\u3002<\/p>\n\n            <p>To address these characteristics during installation, cable manufacturers provide specific minimum bend radius specifications that must be observed to prevent jacket cracking. Installation teams should pay particular attention to ambient temperature during cable pulling operations, as halogen-free cables may require heated storage or pre-warming when installed in cold weather conditions below minus ten degrees Celsius. Modern advanced thermoplastic elastomer and thermoplastic polyolefin formulations have significantly improved the mechanical performance of halogen-free cables, with premium grades achieving flexibility and low-temperature performance approaching traditional PVC while maintaining excellent fire safety characteristics.<sup>35<\/sup><\/p>\n\n            <p class=\"reference\">[34] Wesco. (2025). Cable Materials Evolution: The Shift to Halogen Free. Retrieved from <a href=\"https:\/\/www.wesco.com\/us\/en\/knowledge-hub\/articles\/cable-materials-evolution-the-shift-to-halogen-free.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.wesco.com\/knowledge-hub\/cable-materials-halogen-free<\/a><\/p>\n\n            <p class=\"reference\">[35] Wesco. (2025). Cable Materials Evolution: The Shift to Halogen Free. Retrieved from <a href=\"https:\/\/www.wesco.com\/us\/en\/knowledge-hub\/articles\/cable-materials-evolution-the-shift-to-halogen-free.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.wesco.com\/knowledge-hub\/cable-materials-halogen-free<\/a><\/p>\n\n            <h3>6.2 Cost Considerations and Lifecycle Value <span class=\"bilingual\">\u6210\u672c\u8003\u8651\u548c\u751f\u547d\u5468\u671f\u4ef7\u503c<\/span><\/h3>\n\n            <p>Halogen-free cable materials typically cost thirty to fifty percent more than equivalent PVC-jacketed cables on a purchase price basis. This cost premium reflects the specialized polymer formulations, higher filler content, and more complex manufacturing processes required to achieve halogen-free performance while maintaining necessary electrical and mechanical properties. For large tunnel or mining projects involving hundreds of kilometers of cable installation, this price difference can represent a significant budget impact that requires careful justification.<sup>36<\/sup><\/p>\n\n            <p>However, lifecycle cost analysis that includes potential fire damage, business interruption, equipment replacement, and liability costs presents a very different picture. The devastating equipment damage caused by corrosive gases from halogenated cable fires, as demonstrated in incidents like the AT&#038;T Hinsdale fire, can result in losses measuring hundreds of millions of dollars and service interruptions lasting months. For critical infrastructure applications like subway systems, highway tunnels, and major mining operations, the potential cost of a single catastrophic fire far exceeds the additional cable material cost investment in halogen-free construction.<sup>37<\/sup><\/p>\n\n            <p>Many infrastructure owners have concluded that specifying halogen-free cables throughout a tunnel or underground facility represents the most cost-effective approach to risk management, eliminating the possibility of mixing cable types and ensuring uniform fire safety performance. The relatively modest initial cost premium becomes insignificant when amortized over the decades-long service life of tunnel infrastructure, while the safety and equipment protection benefits provide value throughout the installation&#8217;s operational lifetime.<sup>38<\/sup><\/p>\n\n            <p class=\"reference\">[36] CB Cables. (2025). When to Use Low Smoke Zero Halogen Cables. Retrieved from <a href=\"https:\/\/www.cbcables.com\/blog\/when-to-use-low-smoke-zero-halogen-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.cbcables.com\/blog\/when-to-use-lszh-cables<\/a><\/p>\n\n            <p class=\"reference\">[37] Wesco. (2025). Cable Materials Evolution: The Shift to Halogen Free. Retrieved from <a href=\"https:\/\/www.wesco.com\/us\/en\/knowledge-hub\/articles\/cable-materials-evolution-the-shift-to-halogen-free.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.wesco.com\/knowledge-hub\/cable-materials-halogen-free<\/a><\/p>\n\n            <p class=\"reference\">[38] Top Cable. (2025). Fire Resistant Cables vs Halogen-Free Cables. Retrieved from <a href=\"https:\/\/www.topcable.com\/blog-electric-cable\/fire-resistant-halogenfree\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.topcable.com\/blog\/fire-resistant-halogenfree<\/a><\/p>\n        <\/section>\n\n        <section class=\"company-info\">\n            <h2>About Anhui Feichun Special Cable Co., Ltd. <span class=\"bilingual\">\u5173\u4e8e\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/span><\/h2>\n            \n            <p>Anhui Feichun Special Cable Co., Ltd. specializes in the engineering and manufacturing of halogen-free flame retardant cables for demanding tunnel, mining, and underground infrastructure applications. Our (N)TSCGEW\u00d6U-FR series cables are designed specifically to meet the most stringent international standards for low-smoke, zero-halogen performance, combining superior fire safety characteristics with the mechanical durability and electrical performance required for critical infrastructure installations.<\/p>\n            \n            <p class=\"bilingual\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8\u4e13\u4e1a\u4ece\u4e8b\u7528\u4e8e\u82db\u523b\u96a7\u9053\u3001\u91c7\u77ff\u548c\u5730\u4e0b\u57fa\u7840\u8bbe\u65bd\u5e94\u7528\u7684\u65e0\u5364\u963b\u71c3\u7535\u7f06\u7684\u5de5\u7a0b\u8bbe\u8ba1\u548c\u5236\u9020\u3002\u6211\u4eec\u7684(N)TSCGEW\u00d6U-FR\u7cfb\u5217\u7535\u7f06\u4e13\u95e8\u8bbe\u8ba1\u7528\u4e8e\u6ee1\u8db3\u6700\u4e25\u683c\u7684\u4f4e\u70df\u3001\u96f6\u5364\u6027\u80fd\u56fd\u9645\u6807\u51c6\uff0c\u5c06\u5353\u8d8a\u7684\u9632\u706b\u5b89\u5168\u7279\u6027\u4e0e\u5173\u952e\u57fa\u7840\u8bbe\u65bd\u5b89\u88c5\u6240\u9700\u7684\u673a\u68b0\u8010\u4e45\u6027\u548c\u7535\u6c14\u6027\u80fd\u76f8\u7ed3\u5408\u3002<\/p>\n\n            <p>Our cables comply with international standards including IEC 60754-1, IEC 60754-2, IEC 61034, IEC 60332-3, EN 50575, GB 31247-2014, and GB\/T 19666, with certified performance verification from accredited testing laboratories. We provide comprehensive technical support for tunnel and mining projects worldwide, including specification development, compliance documentation, and installation guidance to ensure optimal fire safety performance throughout the project lifecycle.<\/p>\n\n            <p>With manufacturing facilities equipped for large-scale production and quality control systems certified to international standards, Feichun Cables delivers reliable supply of halogen-free cables for the world&#8217;s most demanding underground infrastructure projects.<\/p>\n\n            <div class=\"contact-info\">\n                <p><strong>Contact Information <span class=\"bilingual\">\u8054\u7cfb\u65b9\u5f0f<\/span>:<\/strong><\/p>\n                <p>\n                    WhatsApp: <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 13855123218<\/a>\n                <\/p>\n                <p>\n                    Technical Support Email: \n                    <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n                <\/p>\n                <p>\n                    Sales Inquiries: \n                    <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a> | \n                    <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a>\n                <\/p>\n            <\/div>\n        <\/section>\n    <\/main>\n\n    <footer>\n        <p><strong>References and Standards:<\/strong><\/p>\n        <p>This technical guide references international standards including IEC 60754 series, IEC 61034, IEC 60332 series, IEC 62821, EN 50575, EN 50305, GB 31247-2014, GB\/T 19666, GB 50217, NFPA 130, NFPA 101, UL 1685, IEEE 1202, BS 6724, and BS 7211. Technical information is based on published research from cable manufacturers, fire safety organizations, testing laboratories, and regulatory authorities worldwide.<\/p>\n        \n        <p style=\"margin-top: 20px;\">\u00a9 2026 Anhui Feichun Special Cable Co., Ltd. All technical information provided for engineering reference purposes. Halogen-free cable requirements vary by jurisdiction and application. Consult with qualified fire safety engineers and follow all applicable codes, standards, and regulations for specific tunnel and mining installations. Cable specifications should be developed based on comprehensive fire risk analysis and regulatory compliance requirements.<\/p>\n    <\/footer>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"Over the past two decades, the cable industry has witnessed a fundamental transformation in safety requirements for confined space installations, particularly in tunnels, underground transit systems, and mining operations. At the center of this evolution lies the shift from traditional halogenated flame retardant cables to halogen-free, low-smoke alternatives. This technological transition represents more than just a materials change\u2014it reflects a deeper understanding of fire safety dynamics and the true risks that cable fires pose to human life, critical infrastructure, and emergency response operations.1\n\u5728\u8fc7\u53bb\u7684\u4e8c\u5341\u5e74\u4e2d\uff0c\u7535\u7f06\u884c\u4e1a\u5728\u5bc6\u95ed\u7a7a\u95f4\u5b89\u88c5\uff08\u7279\u522b\u662f\u96a7\u9053\u3001\u5730\u4e0b\u4ea4\u901a\u7cfb\u7edf\u548c\u91c7\u77ff\u4f5c\u4e1a\uff09\u7684\u5b89\u5168\u8981\u6c42\u65b9\u9762\u53d1\u751f\u4e86\u6839\u672c\u6027\u7684\u8f6c\u53d8\u3002\u8fd9\u4e00\u6f14\u53d8\u7684\u6838\u5fc3\u662f\u4ece\u4f20\u7edf\u7684\u5364\u5316\u963b\u71c3\u7535\u7f06\u5411\u65e0\u5364\u3001\u4f4e\u70df\u66ff\u4ee3\u54c1\u7684\u8f6c\u53d8\u3002","protected":false},"author":1,"featured_media":5190,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,97,1,56],"tags":[34930,34928,15696,22347,34944,1237,18987,34940,11371,34941,34945,15710,34901,34891,667,34952,171,34885,18778,34892,34895,34900,34929,830,34942,11375,34937,152,107,34932,30186,11376,8046,34948,652,656,34943,417,418,697,34898,34897,10894,34934,11523,98,34949,34883,34884,14394,15229,99,34936,1149,1102,34946,111,139,214,34888,204,34939,34927,34893,34896,34886,34882,16553,10027,7186,34955,34950,34931,34889,34887,34933,1074,34938,34951,10895,34894,34902,1037,1091,34947,34899,7902,34890,34935,2288],"class_list":["post-5189","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-lszh-low-smoke-zero-halogen-flexible-cable","category-uncategorized","category-reeling-cable","tag-alpha-wire-halogen-free","tag-belden-lszh","tag-bs-6724","tag-bs-7211","tag-chinese-3c-certification-halogen-free-cable","tag-coal-mining-cable","tag-confined-space-cable","tag-confined-space-toxic-gas-evacuation","tag-construction-products-regulation","tag-corrosive-gas-damage-from-pvc-cables","tag-cost-benefit-analysis-lszh-cables","tag-cpr-cable","tag-din-en-60754","tag-en-50305","tag-en-50575","tag-evacuation-visibility-tunnel-fires","tag-explosion-proof-mining-cable","tag-flame-retardant-non-corrosive-2","tag-frnc-cable","tag-gb-31247-2014","tag-gb-50217","tag-gb-t-19666","tag-general-cable-halogen-free","tag-halogen-free-cable","tag-halogen-free-cable-installation-cold-weather","tag-halogen-free-flame-retardant","tag-halogen-free-flame-retardant-mining-cable","tag-heavy-duty-mining-cable","tag-heavy-duty-e-loader-mining-cable","tag-helukabel-lszh","tag-hf-cable","tag-hffr-cable","tag-highway-tunnel-cable","tag-highway-tunnel-communication-cable-requirements","tag-iec-60332-1","tag-iec-60332-3","tag-iec-60754-halogen-content-testing","tag-iec-60754-1","tag-iec-60754-2","tag-iec-61034","tag-iec-61249-2-21","tag-iec-62821","tag-ieee-1202","tag-lake-cable-lszh","tag-low-smoke-halogen-free","tag-low-smoke-zero-halogen","tag-low-smoke-zero-halogen-testing-standards","tag-ls0h-cable","tag-lsfh-cable","tag-lshf-cable","tag-lsoh-cable","tag-lszh-cable","tag-lszh-cable-requirements-subway-projects","tag-metal-mining-cable","tag-metro-cable","tag-metro-tunnel-lszh-power-cable","tag-mining-cable","tag-mining-cables","tag-mining-power-cable","tag-mining-shaft-cable","tag-mining-trailing-cable","tag-msha-halogen-free-mining-cable","tag-nexans-halogen-free","tag-nfpa-101","tag-nfpa-130","tag-non-halogenated-cable-2","tag-ntscgewou-fr","tag-prysmian-lszh","tag-rail-transit-cable","tag-railway-tunnel-cable","tag-regulatory-requirements-halogen-free-cables-europe","tag-smoke-density-light-transmittance-requirements","tag-southwire-lszh","tag-subsurface-cable","tag-subway-cable","tag-top-cable-halogen-free","tag-tunnel-cable","tag-tunnel-cable-fire-safety-regulations","tag-tunnel-ventilation-fire-safety-cables","tag-ul-1685","tag-ul-2885","tag-ul-94-flame-rating","tag-underground-cable","tag-underground-mining-cable","tag-underground-railway-cable-specifications","tag-vde-0482-754","tag-vehicular-tunnel-cable","tag-ventilation-tunnel-cable","tag-why-halogen-free-cables-mandatory-tunnels","tag-zero-halogen-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=5189"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5189\/revisions"}],"predecessor-version":[{"id":5191,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/5189\/revisions\/5191"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/5190"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=5189"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=5189"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=5189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}