{"id":4922,"date":"2026-01-23T08:56:08","date_gmt":"2026-01-23T00:56:08","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=4922"},"modified":"2026-01-23T08:56:11","modified_gmt":"2026-01-23T00:56:11","slug":"how-does-the-anti-torsion-braid-prevent-cable-twisting-during-reeling","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/how-does-the-anti-torsion-braid-prevent-cable-twisting-during-reeling\/","title":{"rendered":"How Does the Anti-Torsion Braid Prevent Cable Twisting During Reeling?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u5982\u4f55\u9632\u6b62\u7535\u7f06\u5728\u6536\u5377\u8fc7\u7a0b\u4e2d\u53d1\u751f\u626d\u8f6c\uff1f<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img data-dominant-color=\"5b6261\" data-has-transparency=\"false\" loading=\"lazy\" decoding=\"async\" width=\"491\" height=\"609\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-575.avif\" alt=\"\" class=\"wp-image-4923 not-transparent\" style=\"--dominant-color: #5b6261; width:640px;height:auto\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-575.avif 491w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-575-242x300.avif 242w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-575-400x496.avif 400w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"Technical analysis of anti-torsion braids in cable sheaths and their role in preventing cable twisting during reeling operations - Anhui Feichun Special Cable Co., Ltd.\">\n    <title>How Anti-Torsion Braids Prevent Cable Twisting During Reeling | Anhui Feichun Special Cable<\/title>\n    <style>\n        * {\n            margin: 0;\n            padding: 0;\n            box-sizing: border-box;\n        }\n\n        body {\n            font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n            line-height: 1.8;\n            max-width: 100%;\n            padding: 20px;\n        }\n\n        .container {\n            max-width: 1200px;\n            margin: 0 auto;\n            width: 100%;\n        }\n\n        header {\n            padding: 30px 0;\n            border-bottom: 2px solid;\n            margin-bottom: 40px;\n        }\n\n        h1 {\n            font-size: 2em;\n            margin-bottom: 15px;\n            font-weight: 700;\n        }\n\n        h2 {\n            font-size: 1.5em;\n            margin: 40px 0 20px 0;\n            font-weight: 600;\n        }\n\n        h3 {\n            font-size: 1.2em;\n            margin: 30px 0 15px 0;\n            font-weight: 600;\n        }\n\n        .subtitle {\n            font-size: 0.95em;\n            opacity: 0.8;\n            margin-top: 10px;\n        }\n\n        p {\n            margin-bottom: 20px;\n            text-align: justify;\n        }\n\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            margin: 30px 0;\n            font-size: 0.95em;\n        }\n\n        th, td {\n            padding: 15px;\n            text-align: left;\n            border: 1px solid;\n        }\n\n        th {\n            font-weight: 600;\n        }\n\n        .company-info {\n            margin: 50px 0;\n            padding: 30px;\n            border: 2px solid;\n            border-radius: 8px;\n        }\n\n        .contact-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(250px, 1fr));\n            gap: 20px;\n            margin-top: 20px;\n        }\n\n        .contact-item {\n            padding: 15px;\n            border: 1px solid;\n            border-radius: 5px;\n        }\n\n        .contact-item strong {\n            display: block;\n            margin-bottom: 8px;\n            font-size: 1.05em;\n        }\n\n        a {\n            text-decoration: none;\n            border-bottom: 1px dotted;\n        }\n\n        a:hover {\n            opacity: 0.7;\n        }\n\n        .reference-section {\n            margin-top: 50px;\n            padding-top: 30px;\n            border-top: 2px solid;\n        }\n\n        .reference-list {\n            margin-top: 20px;\n        }\n\n        .reference-item {\n            margin-bottom: 15px;\n            padding-left: 20px;\n            text-indent: -20px;\n        }\n\n        footer {\n            margin-top: 60px;\n            padding-top: 30px;\n            border-top: 2px solid;\n            text-align: center;\n            opacity: 0.8;\n        }\n\n        @media (prefers-color-scheme: dark) {\n            body {\n                background-color: #1a1a1a;\n                color: #e0e0e0;\n            }\n            \n            th, td {\n                border-color: #444;\n            }\n            \n            header {\n                border-bottom-color: #444;\n            }\n            \n            .company-info {\n                border-color: #444;\n            }\n            \n            .contact-item {\n                border-color: #444;\n            }\n            \n            .reference-section {\n                border-top-color: #444;\n            }\n            \n            footer {\n                border-top-color: #444;\n            }\n        }\n\n        @media (prefers-color-scheme: light) {\n            body {\n                background-color: #ffffff;\n                color: #333333;\n            }\n            \n            th, td {\n                border-color: #ddd;\n            }\n            \n            header {\n                border-bottom-color: #ddd;\n            }\n            \n            .company-info {\n                border-color: #ddd;\n            }\n            \n            .contact-item {\n                border-color: #ddd;\n            }\n            \n            .reference-section {\n                border-top-color: #ddd;\n            }\n            \n            footer {\n                border-top-color: #ddd;\n            }\n        }\n\n        .bilingual {\n            margin-top: 8px;\n            font-size: 0.92em;\n            opacity: 0.85;\n            font-style: italic;\n        }\n    <\/style>\n<\/head>\n<body>\n    <div class=\"container\">\n        <header>\n            <h1>How Does the Anti-Torsion Braid Prevent Cable Twisting During Reeling?<\/h1>\n            <p class=\"subtitle bilingual\">\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u5982\u4f55\u9632\u6b62\u7535\u7f06\u5728\u6536\u5377\u8fc7\u7a0b\u4e2d\u53d1\u751f\u626d\u8f6c\uff1f<\/p>\n            <p class=\"subtitle\">Anhui Feichun Special Cable Co., Ltd. | \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n        <\/header>\n\n        <article>\n            <section>\n                <h2>Introduction<\/h2>\n                <p class=\"bilingual\">\u5f15\u8a00<\/p>\n                \n                <p>In industrial cable applications involving continuous reeling and unreeling operations, cable integrity under mechanical stress is paramount. One critical structural element that ensures operational reliability is the anti-torsion braid, also known as an embedded textile mesh, positioned within the cable sheath. This technical component plays a vital role in maintaining cable performance in demanding environments such as crane systems, hoists, conveyor belts, and mobile machinery.<\/p>\n                <p class=\"bilingual\">\u5728\u6d89\u53ca\u8fde\u7eed\u6536\u5377\u548c\u653e\u5377\u64cd\u4f5c\u7684\u5de5\u4e1a\u7535\u7f06\u5e94\u7528\u4e2d\uff0c\u673a\u68b0\u5e94\u529b\u4e0b\u7684\u7535\u7f06\u5b8c\u6574\u6027\u81f3\u5173\u91cd\u8981\u3002\u786e\u4fdd\u64cd\u4f5c\u53ef\u9760\u6027\u7684\u4e00\u4e2a\u5173\u952e\u7ed3\u6784\u5143\u4ef6\u662f\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\uff0c\u4e5f\u79f0\u4e3a\u5d4c\u5165\u5f0f\u7eba\u7ec7\u7f51\uff0c\u4f4d\u4e8e\u7535\u7f06\u62a4\u5957\u5185\u3002\u8be5\u6280\u672f\u7ec4\u4ef6\u5728\u8d77\u91cd\u673a\u7cfb\u7edf\u3001\u63d0\u5347\u673a\u3001\u4f20\u9001\u5e26\u548c\u79fb\u52a8\u673a\u68b0\u7b49\u82db\u523b\u73af\u5883\u4e2d\u7ef4\u62a4\u7535\u7f06\u6027\u80fd\u65b9\u9762\u8d77\u7740\u81f3\u5173\u91cd\u8981\u7684\u4f5c\u7528\u3002<\/p>\n\n                <p>The anti-torsion braid functions as a mechanical reinforcement layer that resists rotational forces generated during cable movement. When cables are subjected to reeling operations, they experience complex mechanical stresses including bending, tension, and most critically, torsional strain. Without adequate torsion protection, cables can develop permanent twists, conductor displacement, insulation damage, and premature failure.<\/p>\n                <p class=\"bilingual\">\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u4f5c\u4e3a\u673a\u68b0\u589e\u5f3a\u5c42\uff0c\u62b5\u6297\u7535\u7f06\u8fd0\u52a8\u8fc7\u7a0b\u4e2d\u4ea7\u751f\u7684\u65cb\u8f6c\u529b\u3002\u5f53\u7535\u7f06\u7ecf\u53d7\u6536\u5377\u64cd\u4f5c\u65f6\uff0c\u4f1a\u7ecf\u5386\u590d\u6742\u7684\u673a\u68b0\u5e94\u529b\uff0c\u5305\u62ec\u5f2f\u66f2\u3001\u5f20\u529b\uff0c\u6700\u5173\u952e\u7684\u662f\u626d\u8f6c\u5e94\u53d8\u3002\u5982\u679c\u6ca1\u6709\u8db3\u591f\u7684\u626d\u8f6c\u4fdd\u62a4\uff0c\u7535\u7f06\u4f1a\u4ea7\u751f\u6c38\u4e45\u6027\u626d\u66f2\u3001\u5bfc\u4f53\u4f4d\u79fb\u3001\u7edd\u7f18\u635f\u574f\u548c\u8fc7\u65e9\u5931\u6548\u3002<\/p>\n            <\/section>\n\n            <section>\n                <h2>Structure and Material Composition<\/h2>\n                <p class=\"bilingual\">\u7ed3\u6784\u548c\u6750\u6599\u7ec4\u6210<\/p>\n\n                <p>The anti-torsion braid is strategically positioned between the inner sheath (covering the conductor cores) and the outer protective jacket. This placement is essential for maximizing mechanical effectiveness while maintaining cable flexibility. According to manufacturing standards such as DIN VDE 0250-814 and IEC 60502-2, the braid typically consists of high-strength textile fibers including polyamide (nylon), polyester (PET), or aramid materials.<\/p>\n                <p class=\"bilingual\">\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u6218\u7565\u6027\u5730\u4f4d\u4e8e\u5185\u62a4\u5957\uff08\u8986\u76d6\u5bfc\u4f53\u82af\uff09\u548c\u5916\u4fdd\u62a4\u5c42\u4e4b\u95f4\u3002\u8fd9\u79cd\u653e\u7f6e\u5bf9\u4e8e\u5728\u4fdd\u6301\u7535\u7f06\u67d4\u97e7\u6027\u7684\u540c\u65f6\u6700\u5927\u5316\u673a\u68b0\u6548\u80fd\u81f3\u5173\u91cd\u8981\u3002\u6839\u636eDIN VDE 0250-814\u548cIEC 60502-2\u7b49\u5236\u9020\u6807\u51c6\uff0c\u7f16\u7ec7\u5c42\u901a\u5e38\u7531\u9ad8\u5f3a\u5ea6\u7eba\u7ec7\u7ea4\u7ef4\u7ec4\u6210\uff0c\u5305\u62ec\u805a\u9170\u80fa\uff08\u5c3c\u9f99\uff09\u3001\u805a\u916f\uff08PET\uff09\u6216\u82b3\u7eb6\u6750\u6599\u3002<\/p>\n\n                <p>The braiding pattern follows a specific geometric configuration, typically a diamond or lattice weave structure, which provides omnidirectional strength. The braid coverage percentage typically ranges from 85 to 95 percent, ensuring comprehensive mechanical support without compromising cable flexibility. Material selection depends on the operational environment, with considerations for temperature resistance, chemical exposure, and abrasion resistance.<\/p>\n                <p class=\"bilingual\">\u7f16\u7ec7\u56fe\u6848\u9075\u5faa\u7279\u5b9a\u7684\u51e0\u4f55\u914d\u7f6e\uff0c\u901a\u5e38\u4e3a\u83f1\u5f62\u6216\u7f51\u683c\u7f16\u7ec7\u7ed3\u6784\uff0c\u63d0\u4f9b\u5168\u5411\u5f3a\u5ea6\u3002\u7f16\u7ec7\u8986\u76d6\u7387\u901a\u5e38\u572885%\u81f395%\u4e4b\u95f4\uff0c\u5728\u4e0d\u5f71\u54cd\u7535\u7f06\u67d4\u97e7\u6027\u7684\u60c5\u51b5\u4e0b\u786e\u4fdd\u5168\u9762\u7684\u673a\u68b0\u652f\u6491\u3002\u6750\u6599\u9009\u62e9\u53d6\u51b3\u4e8e\u64cd\u4f5c\u73af\u5883\uff0c\u9700\u8003\u8651\u8010\u6e29\u6027\u3001\u8010\u5316\u5b66\u8150\u8680\u6027\u548c\u8010\u78e8\u6027\u3002<\/p>\n            <\/section>\n\n            <section>\n                <h2>Mechanical Principles of Torsion Prevention<\/h2>\n                <p class=\"bilingual\">\u626d\u8f6c\u9884\u9632\u7684\u673a\u68b0\u539f\u7406<\/p>\n\n                <h3>Load Distribution Mechanism<\/h3>\n                <p class=\"bilingual\">\u8f7d\u8377\u5206\u914d\u673a\u5236<\/p>\n\n                <p>During reeling operations, cables experience torsional forces resulting from the rotational motion of the drum and the linear movement of the equipment. The anti-torsion braid functions by distributing these forces across a larger cross-sectional area, preventing localized stress concentration on individual conductors. The braided structure creates a continuous mechanical pathway that transfers torsional loads from the cable core to the outer sheath, effectively isolating the electrical conductors from rotational stress.<\/p>\n                <p class=\"bilingual\">\u5728\u6536\u5377\u64cd\u4f5c\u8fc7\u7a0b\u4e2d\uff0c\u7535\u7f06\u7531\u4e8e\u6eda\u7b52\u7684\u65cb\u8f6c\u8fd0\u52a8\u548c\u8bbe\u5907\u7684\u7ebf\u6027\u8fd0\u52a8\u800c\u7ecf\u5386\u626d\u8f6c\u529b\u3002\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u901a\u8fc7\u5728\u66f4\u5927\u7684\u6a2a\u622a\u9762\u79ef\u4e0a\u5206\u914d\u8fd9\u4e9b\u529b\u6765\u53d1\u6325\u4f5c\u7528\uff0c\u9632\u6b62\u5355\u4e2a\u5bfc\u4f53\u4e0a\u7684\u5c40\u90e8\u5e94\u529b\u96c6\u4e2d\u3002\u7f16\u7ec7\u7ed3\u6784\u521b\u5efa\u4e86\u4e00\u4e2a\u8fde\u7eed\u7684\u673a\u68b0\u901a\u9053\uff0c\u5c06\u626d\u8f6c\u8f7d\u8377\u4ece\u7535\u7f06\u82af\u4f20\u9012\u5230\u5916\u62a4\u5957\uff0c\u6709\u6548\u5730\u5c06\u7535\u7edd\u7f18\u5bfc\u4f53\u4e0e\u65cb\u8f6c\u5e94\u529b\u9694\u79bb\u3002<\/p>\n\n                <h3>Stranding Direction Compatibility<\/h3>\n                <p class=\"bilingual\">\u7ede\u5408\u65b9\u5411\u517c\u5bb9\u6027<\/p>\n\n                <p>A critical aspect of torsion management relates to stranding direction. Cable conductors are typically laid with either right-hand (Z-lay) or left-hand (S-lay) stranding. The anti-torsion braid must be compatible with the stranding direction to prevent counter-rotation during reeling. Installation guidelines from cable manufacturers specify that cables with right stranding direction should be wound to the right side of the drum, while left-stranded cables wind to the left. The braid reinforces this directional preference, maintaining the natural lay of the conductors.<\/p>\n                <p class=\"bilingual\">\u626d\u8f6c\u7ba1\u7406\u7684\u4e00\u4e2a\u5173\u952e\u65b9\u9762\u6d89\u53ca\u7ede\u5408\u65b9\u5411\u3002\u7535\u7f06\u5bfc\u4f53\u901a\u5e38\u91c7\u7528\u53f3\u624b\uff08Z\u578b\uff09\u6216\u5de6\u624b\uff08S\u578b\uff09\u7ede\u5408\u3002\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u5fc5\u987b\u4e0e\u7ede\u5408\u65b9\u5411\u517c\u5bb9\uff0c\u4ee5\u9632\u6b62\u6536\u5377\u8fc7\u7a0b\u4e2d\u7684\u53cd\u5411\u65cb\u8f6c\u3002\u7535\u7f06\u5236\u9020\u5546\u7684\u5b89\u88c5\u6307\u5357\u89c4\u5b9a\uff0c\u53f3\u7ede\u5408\u65b9\u5411\u7684\u7535\u7f06\u5e94\u5411\u6eda\u7b52\u53f3\u4fa7\u7f20\u7ed5\uff0c\u800c\u5de6\u7ede\u5408\u7535\u7f06\u5411\u5de6\u7f20\u7ed5\u3002\u7f16\u7ec7\u5c42\u52a0\u5f3a\u4e86\u8fd9\u79cd\u65b9\u5411\u504f\u597d\uff0c\u4fdd\u6301\u5bfc\u4f53\u7684\u81ea\u7136\u6392\u5217\u3002<\/p>\n            <\/section>\n\n            <section>\n                <h2>Technical Performance Characteristics<\/h2>\n                <p class=\"bilingual\">\u6280\u672f\u6027\u80fd\u7279\u5f81<\/p>\n\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Parameter \u53c2\u6570<\/th>\n                            <th>Specification \u89c4\u683c<\/th>\n                            <th>Benefit \u4f18\u52bf<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>Torsional Resistance<br><span class=\"bilingual\">\u6297\u626d\u8f6c\u6027<\/span><\/td>\n                            <td>\u00b1100\u00b0 per meter max<br><span class=\"bilingual\">\u6bcf\u7c73\u6700\u5927\u00b1100\u00b0<\/span><\/td>\n                            <td>Prevents conductor displacement<br><span class=\"bilingual\">\u9632\u6b62\u5bfc\u4f53\u4f4d\u79fb<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Bending Radius<br><span class=\"bilingual\">\u5f2f\u66f2\u534a\u5f84<\/span><\/td>\n                            <td>15 \u00d7 cable diameter (min)<br><span class=\"bilingual\">15\u500d\u7535\u7f06\u76f4\u5f84\uff08\u6700\u5c0f\uff09<\/span><\/td>\n                            <td>Maintains cable flexibility<br><span class=\"bilingual\">\u4fdd\u6301\u7535\u7f06\u67d4\u97e7\u6027<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Temperature Range<br><span class=\"bilingual\">\u6e29\u5ea6\u8303\u56f4<\/span><\/td>\n                            <td>-40\u00b0C to +90\u00b0C<br><span class=\"bilingual\">-40\u00b0C\u81f3+90\u00b0C<\/span><\/td>\n                            <td>Stable performance across environments<br><span class=\"bilingual\">\u8de8\u73af\u5883\u7a33\u5b9a\u6027\u80fd<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Abrasion Resistance<br><span class=\"bilingual\">\u8010\u78e8\u6027<\/span><\/td>\n                            <td>High (per IEC 60811-2-1)<br><span class=\"bilingual\">\u9ad8\uff08\u7b26\u5408IEC 60811-2-1\uff09<\/span><\/td>\n                            <td>Extended service life<br><span class=\"bilingual\">\u5ef6\u957f\u4f7f\u7528\u5bff\u547d<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td>Flexing Cycles<br><span class=\"bilingual\">\u5f2f\u66f2\u5faa\u73af<\/span><\/td>\n                            <td>>1,000,000 cycles<br><span class=\"bilingual\">>1,000,000\u6b21\u5faa\u73af<\/span><\/td>\n                            <td>Reliable for continuous reeling<br><span class=\"bilingual\">\u8fde\u7eed\u6536\u5377\u7684\u53ef\u9760\u6027<\/span><\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/section>\n\n            <section>\n                <h2>Application in Reeling Drum Systems<\/h2>\n                <p class=\"bilingual\">\u5728\u6536\u5377\u7cfb\u7edf\u4e2d\u7684\u5e94\u7528<\/p>\n\n                <h3>Spring-Operated Reeling Drums<\/h3>\n                <p class=\"bilingual\">\u5f39\u7c27\u64cd\u4f5c\u6536\u5377\u6eda\u7b52<\/p>\n\n                <p>In spring-operated cable reeling systems, the anti-torsion braid becomes particularly critical due to the constant tension maintained by the spring mechanism. These systems, commonly used in overhead cranes and material handling equipment, apply continuous rotational force to the cable. The braid prevents the cable from developing a permanent twist memory, which could cause kinking or conductor damage over thousands of reeling cycles.<\/p>\n                <p class=\"bilingual\">\u5728\u5f39\u7c27\u64cd\u4f5c\u7684\u7535\u7f06\u6536\u5377\u7cfb\u7edf\u4e2d\uff0c\u7531\u4e8e\u5f39\u7c27\u673a\u6784\u4fdd\u6301\u6052\u5b9a\u5f20\u529b\uff0c\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u53d8\u5f97\u5c24\u4e3a\u5173\u952e\u3002\u8fd9\u4e9b\u7cfb\u7edf\u901a\u5e38\u7528\u4e8e\u6865\u5f0f\u8d77\u91cd\u673a\u548c\u7269\u6599\u642c\u8fd0\u8bbe\u5907\uff0c\u5bf9\u7535\u7f06\u65bd\u52a0\u8fde\u7eed\u7684\u65cb\u8f6c\u529b\u3002\u7f16\u7ec7\u5c42\u9632\u6b62\u7535\u7f06\u4ea7\u751f\u6c38\u4e45\u6027\u626d\u8f6c\u8bb0\u5fc6\uff0c\u8fd9\u53ef\u80fd\u5bfc\u81f4\u5728\u6570\u5343\u6b21\u6536\u5377\u5faa\u73af\u4e2d\u51fa\u73b0\u626d\u7ed3\u6216\u5bfc\u4f53\u635f\u574f\u3002<\/p>\n\n                <h3>Motorized Reeling Drums<\/h3>\n                <p class=\"bilingual\">\u7535\u52a8\u6536\u5377\u6eda\u7b52<\/p>\n\n                <p>Motorized or torque-controlled reeling systems present different mechanical challenges. These drums, driven by AC or DC motors, can generate significant rotational speeds and require cables capable of withstanding rapid acceleration and deceleration. The anti-torsion braid provides dimensional stability during these dynamic conditions, maintaining consistent electrical performance even under variable mechanical loads. This is essential for applications such as ship-to-shore cranes, rail-mounted gantry cranes, and stacker reclaimers where cable lengths can exceed several hundred meters.<\/p>\n                <p class=\"bilingual\">\u7535\u52a8\u6216\u626d\u77e9\u63a7\u5236\u7684\u6536\u5377\u7cfb\u7edf\u63d0\u51fa\u4e86\u4e0d\u540c\u7684\u673a\u68b0\u6311\u6218\u3002\u8fd9\u4e9b\u7531\u4ea4\u6d41\u6216\u76f4\u6d41\u7535\u673a\u9a71\u52a8\u7684\u6eda\u7b52\u53ef\u4ee5\u4ea7\u751f\u663e\u8457\u7684\u65cb\u8f6c\u901f\u5ea6\uff0c\u9700\u8981\u80fd\u591f\u627f\u53d7\u5feb\u901f\u52a0\u901f\u548c\u51cf\u901f\u7684\u7535\u7f06\u3002\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u5728\u8fd9\u4e9b\u52a8\u6001\u6761\u4ef6\u4e0b\u63d0\u4f9b\u5c3a\u5bf8\u7a33\u5b9a\u6027\uff0c\u5373\u4f7f\u5728\u53ef\u53d8\u673a\u68b0\u8f7d\u8377\u4e0b\u4e5f\u4fdd\u6301\u4e00\u81f4\u7684\u7535\u6c14\u6027\u80fd\u3002\u8fd9\u5bf9\u4e8e\u5cb8\u6865\u8d77\u91cd\u673a\u3001\u8f68\u9053\u5f0f\u9f99\u95e8\u8d77\u91cd\u673a\u548c\u5806\u53d6\u6599\u673a\u7b49\u5e94\u7528\u81f3\u5173\u91cd\u8981\uff0c\u8fd9\u4e9b\u5e94\u7528\u4e2d\u7535\u7f06\u957f\u5ea6\u53ef\u8d85\u8fc7\u6570\u767e\u7c73\u3002<\/p>\n            <\/section>\n\n            <section>\n                <h2>Standards and Compliance<\/h2>\n                <p class=\"bilingual\">\u6807\u51c6\u4e0e\u5408\u89c4<\/p>\n\n                <table>\n                    <thead>\n                        <tr>\n                            <th>Standard \u6807\u51c6<\/th>\n                            <th>Title \u6807\u9898<\/th>\n                            <th>Key Requirements \u5173\u952e\u8981\u6c42<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td>DIN VDE 0250-814<\/td>\n                            <td>Rubber-sheathed cables for reeling applications<br><span class=\"bilingual\">\u7528\u4e8e\u6536\u5377\u5e94\u7528\u7684\u6a61\u80f6\u62a4\u5957\u7535\u7f06<\/span><\/td>\n                            <td>Torsion resistance, flexing endurance<br><span class=\"bilingual\">\u6297\u626d\u8f6c\u6027\u3001\u5f2f\u66f2\u8010\u4e45\u6027<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td>IEC 60502-2<\/td>\n                            <td>Power cables with extruded insulation<br><span class=\"bilingual\">\u6324\u538b\u7edd\u7f18\u7535\u529b\u7535\u7f06<\/span><\/td>\n                            <td>Mechanical and electrical properties<br><span class=\"bilingual\">\u673a\u68b0\u548c\u7535\u6c14\u7279\u6027<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td>IEC 60332-1<\/td>\n                            <td>Flame retardant testing<br><span class=\"bilingual\">\u963b\u71c3\u6d4b\u8bd5<\/span><\/td>\n                            <td>Fire safety performance<br><span class=\"bilingual\">\u6d88\u9632\u5b89\u5168\u6027\u80fd<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td>IEC 60811-2-1<\/td>\n                            <td>Chemical properties testing<br><span class=\"bilingual\">\u5316\u5b66\u7279\u6027\u6d4b\u8bd5<\/span><\/td>\n                            <td>Oil resistance, environmental durability<br><span class=\"bilingual\">\u8010\u6cb9\u6027\u3001\u73af\u5883\u8010\u4e45\u6027<\/span><\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n            <\/section>\n\n            <section>\n                <h2>Installation and Operational Considerations<\/h2>\n                <p class=\"bilingual\">\u5b89\u88c5\u548c\u64cd\u4f5c\u6ce8\u610f\u4e8b\u9879<\/p>\n\n                <p>Proper installation is critical to maximizing the effectiveness of anti-torsion braids. Cable manufacturers recommend torsion-free mounting procedures where the cable is wound directly from the supply drum to the reeling drum without complete unwinding. This preserves the factory-set lay length and prevents introducing initial torsional stress. The cable must be fixed and connected in a torsion-free manner, with at least two windings remaining on the drum even at full extension to maintain mechanical integrity.<\/p>\n                <p class=\"bilingual\">\u6b63\u786e\u7684\u5b89\u88c5\u5bf9\u4e8e\u6700\u5927\u5316\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u7684\u6709\u6548\u6027\u81f3\u5173\u91cd\u8981\u3002\u7535\u7f06\u5236\u9020\u5546\u5efa\u8bae\u91c7\u7528\u65e0\u626d\u8f6c\u5b89\u88c5\u7a0b\u5e8f\uff0c\u5c06\u7535\u7f06\u76f4\u63a5\u4ece\u4f9b\u5e94\u6eda\u7b52\u7f20\u7ed5\u5230\u6536\u5377\u6eda\u7b52\u4e0a\uff0c\u800c\u65e0\u9700\u5b8c\u5168\u5c55\u5f00\u3002\u8fd9\u4fdd\u7559\u4e86\u51fa\u5382\u8bbe\u7f6e\u7684\u6392\u5217\u957f\u5ea6\uff0c\u9632\u6b62\u5f15\u5165\u521d\u59cb\u626d\u8f6c\u5e94\u529b\u3002\u7535\u7f06\u5fc5\u987b\u4ee5\u65e0\u626d\u8f6c\u65b9\u5f0f\u56fa\u5b9a\u548c\u8fde\u63a5\uff0c\u5373\u4f7f\u5728\u5b8c\u5168\u5ef6\u4f38\u65f6\u4e5f\u81f3\u5c11\u5728\u6eda\u7b52\u4e0a\u4fdd\u7559\u4e24\u5708\uff0c\u4ee5\u4fdd\u6301\u673a\u68b0\u5b8c\u6574\u6027\u3002<\/p>\n\n                <p>During operation, monitoring systems should track cable behavior for signs of excessive torsion, including irregular winding patterns, conductor protrusion, or visible sheath deformation. Regular inspection intervals should verify that the minimum bending radius is maintained and that the cable shows no signs of permanent set or twist accumulation. When replacement becomes necessary, the new cable should match the original stranding direction and braid configuration to ensure system compatibility.<\/p>\n                <p class=\"bilingual\">\u5728\u64cd\u4f5c\u671f\u95f4\uff0c\u76d1\u63a7\u7cfb\u7edf\u5e94\u8ddf\u8e2a\u7535\u7f06\u884c\u4e3a\u4ee5\u53d1\u73b0\u8fc7\u5ea6\u626d\u8f6c\u7684\u8ff9\u8c61\uff0c\u5305\u62ec\u4e0d\u89c4\u5219\u7684\u7f20\u7ed5\u6a21\u5f0f\u3001\u5bfc\u4f53\u7a81\u51fa\u6216\u53ef\u89c1\u7684\u62a4\u5957\u53d8\u5f62\u3002\u5b9a\u671f\u68c0\u67e5\u95f4\u9694\u5e94\u9a8c\u8bc1\u662f\u5426\u4fdd\u6301\u6700\u5c0f\u5f2f\u66f2\u534a\u5f84\uff0c\u7535\u7f06\u662f\u5426\u663e\u793a\u51fa\u6c38\u4e45\u53d8\u5f62\u6216\u626d\u8f6c\u7d2f\u79ef\u7684\u8ff9\u8c61\u3002\u5f53\u9700\u8981\u66f4\u6362\u65f6\uff0c\u65b0\u7535\u7f06\u5e94\u4e0e\u539f\u59cb\u7ede\u5408\u65b9\u5411\u548c\u7f16\u7ec7\u914d\u7f6e\u76f8\u5339\u914d\uff0c\u4ee5\u786e\u4fdd\u7cfb\u7edf\u517c\u5bb9\u6027\u3002<\/p>\n            <\/section>\n\n            <section>\n                <h2>Conclusion<\/h2>\n                <p class=\"bilingual\">\u7ed3\u8bba<\/p>\n\n                <p>The anti-torsion braid represents a critical engineering solution for cable reliability in reeling applications. By providing mechanical reinforcement that resists rotational forces, distributes torsional loads, and maintains dimensional stability, this structural element enables cables to withstand millions of flexing cycles without degradation. As industrial systems continue to demand higher performance and longer service life, the role of anti-torsion technology in cable design becomes increasingly vital.<\/p>\n                <p class=\"bilingual\">\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\u4ee3\u8868\u4e86\u6536\u5377\u5e94\u7528\u4e2d\u7535\u7f06\u53ef\u9760\u6027\u7684\u5173\u952e\u5de5\u7a0b\u89e3\u51b3\u65b9\u6848\u3002\u901a\u8fc7\u63d0\u4f9b\u62b5\u6297\u65cb\u8f6c\u529b\u3001\u5206\u914d\u626d\u8f6c\u8f7d\u8377\u548c\u4fdd\u6301\u5c3a\u5bf8\u7a33\u5b9a\u6027\u7684\u673a\u68b0\u589e\u5f3a\uff0c\u8be5\u7ed3\u6784\u5143\u4ef6\u4f7f\u7535\u7f06\u80fd\u591f\u627f\u53d7\u6570\u767e\u4e07\u6b21\u5f2f\u66f2\u5faa\u73af\u800c\u4e0d\u9000\u5316\u3002\u968f\u7740\u5de5\u4e1a\u7cfb\u7edf\u7ee7\u7eed\u8981\u6c42\u66f4\u9ad8\u7684\u6027\u80fd\u548c\u66f4\u957f\u7684\u4f7f\u7528\u5bff\u547d\uff0c\u53cd\u626d\u8f6c\u6280\u672f\u5728\u7535\u7f06\u8bbe\u8ba1\u4e2d\u7684\u4f5c\u7528\u53d8\u5f97\u8d8a\u6765\u8d8a\u91cd\u8981\u3002<\/p>\n\n                <p>For applications involving heavy-duty reeling operations, proper cable selection incorporating proven anti-torsion braid technology ensures operational reliability, minimizes maintenance costs, and maximizes equipment uptime. Understanding the mechanical principles and material science behind these protective structures allows engineers to specify appropriate cable solutions for even the most demanding industrial environments.<\/p>\n                <p class=\"bilingual\">\u5bf9\u4e8e\u6d89\u53ca\u91cd\u578b\u6536\u5377\u64cd\u4f5c\u7684\u5e94\u7528\uff0c\u6b63\u786e\u9009\u62e9\u91c7\u7528\u7ecf\u8fc7\u9a8c\u8bc1\u7684\u53cd\u626d\u8f6c\u7f16\u7ec7\u6280\u672f\u7684\u7535\u7f06\u53ef\u786e\u4fdd\u64cd\u4f5c\u53ef\u9760\u6027\u3001\u6700\u5c0f\u5316\u7ef4\u62a4\u6210\u672c\u5e76\u6700\u5927\u5316\u8bbe\u5907\u6b63\u5e38\u8fd0\u884c\u65f6\u95f4\u3002\u4e86\u89e3\u8fd9\u4e9b\u4fdd\u62a4\u7ed3\u6784\u80cc\u540e\u7684\u673a\u68b0\u539f\u7406\u548c\u6750\u6599\u79d1\u5b66\u4f7f\u5de5\u7a0b\u5e08\u80fd\u591f\u4e3a\u5373\u4f7f\u662f\u6700\u82db\u523b\u7684\u5de5\u4e1a\u73af\u5883\u6307\u5b9a\u9002\u5f53\u7684\u7535\u7f06\u89e3\u51b3\u65b9\u6848\u3002<\/p>\n            <\/section>\n\n            <div class=\"company-info\">\n                <h2>Contact Anhui Feichun Special Cable Co., Ltd.<\/h2>\n                <p class=\"bilingual\">\u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n                \n                <div class=\"contact-grid\">\n                    <div class=\"contact-item\">\n                        <strong>WhatsApp<\/strong>\n                        <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 13855 123218<\/a>\n                    <\/div>\n                    <div class=\"contact-item\">\n                        <strong>Technical Support \u6280\u672f\u652f\u6301<\/strong>\n                        <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n                    <\/div>\n                    <div class=\"contact-item\">\n                        <strong>Sales Contact \u9500\u552e\u8054\u7cfb<\/strong>\n                        <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a>\n                    <\/div>\n                    <div class=\"contact-item\">\n                        <strong>Engineering Inquiries \u5de5\u7a0b\u54a8\u8be2<\/strong>\n                        <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a>\n                    <\/div>\n                <\/div>\n            <\/div>\n\n            <div class=\"reference-section\">\n                <h2>References and External Resources<\/h2>\n                <p class=\"bilingual\">\u53c2\u8003\u6587\u732e\u548c\u5916\u90e8\u8d44\u6e90<\/p>\n                \n                <div class=\"reference-list\">\n                    <div class=\"reference-item\">\n                        [1] SAB Cable. (2024). &#8220;Installation Instructions &#8211; Reeling Cables and Wires.&#8221; <a href=\"https:\/\/www.sab-cable.com\/cables-wires-harnessing-temperature-measurement\/technical-data\/cables-and-wires\/installation-instructions-for-reeling-cables.html\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.sab-cable.com<\/a>\n                    <\/div>\n                    \n                    <div class=\"reference-item\">\n                        [2] NSHTOU Cables. (2021). &#8220;Drum Reeling Cable &#8211; Structure and Standards.&#8221; <a href=\"https:\/\/honestcable.com\/nshtou-drum-reeling-cable\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/honestcable.com<\/a>\n                    <\/div>\n                    \n                    <div class=\"reference-item\">\n                        [3] UK Cables. (2024). &#8220;Drum Reeling Cable Technical Specifications.&#8221; <a href=\"https:\/\/www.ukcables.co.uk\/cables\/drum-reeling\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.ukcables.co.uk<\/a>\n                    <\/div>\n                    \n                    <div class=\"reference-item\">\n                        [4] Honest Cable. (2025). &#8220;Heavy-Duty Reeling Cable for Industrial Power &#038; Control.&#8221; <a href=\"https:\/\/honestcable.com\/reeling-cable\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/honestcable.com<\/a>\n                    <\/div>\n                    \n                    <div class=\"reference-item\">\n                        [5] HellermannTyton. (2024). &#8220;Braided Sleeving Technical Guide.&#8221; <a href=\"https:\/\/www.hellermanntyton.com\/competences\/braided-sleeving\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.hellermanntyton.com<\/a>\n                    <\/div>\n                    \n                    <div class=\"reference-item\">\n                        [6] Elektromag. (2024). &#8220;Cable Reeling Drum Systems and Applications.&#8221; <a href=\"https:\/\/elektromag.com\/cable_reeling_drums\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/elektromag.com<\/a>\n                    <\/div>\n                    \n                    <div class=\"reference-item\">\n                        [7] VDE Publishing House. &#8220;IEC\/DIN VDE Standards for Cable Testing and Certification.&#8221; <a href=\"https:\/\/www.vde-verlag.de\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.vde-verlag.de<\/a>\n                    <\/div>\n                    \n                    <div class=\"reference-item\">\n                        [8] Atkins &#038; Pearce. (2024). &#8220;Expandable Braided Sleeving Engineering Guide.&#8221; <a href=\"https:\/\/www.atkinsandpearce.com\/product-category\/expandable-braided-sleeving\/\" rel=\"nofollow noopener\" target=\"_blank\">https:\/\/www.atkinsandpearce.com<\/a>\n                    <\/div>\n                <\/div>\n            <\/div>\n        <\/article>\n\n        <footer>\n            <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. | \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n            <p>All technical specifications are subject to verification and may vary based on application requirements.<\/p>\n            <p class=\"bilingual\">\u6240\u6709\u6280\u672f\u89c4\u683c\u5747\u9700\u9a8c\u8bc1\uff0c\u53ef\u80fd\u6839\u636e\u5e94\u7528\u8981\u6c42\u800c\u6709\u6240\u4e0d\u540c\u3002<\/p>\n        <\/footer>\n    <\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"In industrial cable applications involving continuous reeling and unreeling operations, cable integrity under mechanical stress is paramount. One critical structural element that ensures operational reliability is the anti-torsion braid, also known as an embedded textile mesh, positioned within the cable sheath. This technical component plays a vital role in maintaining cable performance in demanding environments such as crane systems, hoists, conveyor belts, and mobile machinery.\n\u5728\u6d89\u53ca\u8fde\u7eed\u6536\u5377\u548c\u653e\u5377\u64cd\u4f5c\u7684\u5de5\u4e1a\u7535\u7f06\u5e94\u7528\u4e2d\uff0c\u673a\u68b0\u5e94\u529b\u4e0b\u7684\u7535\u7f06\u5b8c\u6574\u6027\u81f3\u5173\u91cd\u8981\u3002\u786e\u4fdd\u64cd\u4f5c\u53ef\u9760\u6027\u7684\u4e00\u4e2a\u5173\u952e\u7ed3\u6784\u5143\u4ef6\u662f\u53cd\u626d\u8f6c\u7f16\u7ec7\u5c42\uff0c\u4e5f\u79f0\u4e3a\u5d4c\u5165\u5f0f\u7eba\u7ec7\u7f51\uff0c\u4f4d\u4e8e\u7535\u7f06\u62a4\u5957\u5185\u3002\u8be5\u6280\u672f\u7ec4\u4ef6\u5728\u8d77\u91cd\u673a\u7cfb\u7edf\u3001\u63d0\u5347\u673a\u3001\u4f20\u9001\u5e26\u548c\u79fb\u52a8\u673a\u68b0\u7b49\u82db\u523b\u73af\u5883\u4e2d\u7ef4\u62a4\u7535\u7f06\u6027\u80fd\u65b9\u9762\u8d77\u7740\u81f3\u5173\u91cd\u8981\u7684\u4f5c\u7528\u3002","protected":false},"author":1,"featured_media":4923,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[46,66,8,94,464,9563,1,56,101],"tags":[989,11024,2264,32780,32497,9849,32759,32771,1021,32753,2769,32758,4505,10549,32774,4667,6982,32754,32748,1111,1064,998,32779,32752,32763,23077,780,32778,2618,32755,2779,820,32750,1002,1012,32762,22726,32764,3057,32760,1107,32747,16975,16891,652,618,32761,1044,32751,32776,32769,8989,4593,149,111,524,1696,7517,7597,32766,1006,3158,2692,3311,32775,1233,32770,17,32749,32757,1084,3186,2401,14543,32773,32765,32768,32777,32772,26457,2604,32756,32767,766,994,2781,18959,20074,22788,22163,32744,32745,22736,32135,32742,31878,32743,11984,31718,32746,32741,22977,32740],"class_list":["post-4922","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cable-for-shore-connection-systems","category-common-problems-encountered-in-cable-applications","category-cranes-and-material-handling-cable","category-din-vde-0250-mining-cable","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","category-medium-voltage-cable","category-uncategorized","category-reeling-cable","category-submersible-pump-cable","tag-0-6-1kv-cable","tag-1-8-3kv-cable","tag-600-1000v-cable","tag-ac-cable","tag-anti-torsion-braid-function","tag-anti-twist-cable","tag-anti-twist-layer-in-cable-sheath","tag-automatic-cable-reel","tag-automation-cable","tag-cable-braid-for-torsion-prevention","tag-cable-chain-system","tag-cable-conductor-displacement-prevention","tag-cable-drum","tag-cable-drum-systems","tag-cable-festoon-system","tag-cable-reeling-drum","tag-cable-reeling-system","tag-cable-stranding-direction-compatibility","tag-cable-torsion-protection-mechanism","tag-construction-equipment-cable","tag-conveyor-cable","tag-crane-cable","tag-crane-cable-application","tag-crane-cable-torsion-resistance","tag-crd-cable","tag-dc-cable","tag-din-vde-0250-814","tag-dock-equipment-cable","tag-drum-reeling-cable","tag-drum-reeling-cable-specifications","tag-eot-crane-cable","tag-epr-insulated-cable","tag-flexible-cable-for-continuous-reeling","tag-flexible-power-cable","tag-gantry-crane-cable","tag-hd-21","tag-hd-22","tag-heavy-duty-reeling-cable-2","tag-heavy-machinery-cable","tag-high-flex-reeling-cable-durability","tag-hoist-cable","tag-how-to-prevent-cable-twisting-during-reeling","tag-iec-60227","tag-iec-60245","tag-iec-60332-1","tag-iec-60502-2","tag-iec-60811-2-1","tag-industrial-cable","tag-industrial-cable-mechanical-protection","tag-industrial-crane","tag-lifting-magnet-cable","tag-low-voltage-reeling-cable","tag-material-handling-equipment","tag-medium-voltage-cable","tag-mining-cable","tag-mining-equipment","tag-mobile-equipment-cable","tag-mobile-equipment-power-supply","tag-motorized-cable-reel","tag-motorized-reeling-drum","tag-neoprene-cable","tag-nshtou-cable","tag-overhead-crane-cable","tag-port-equipment-cable","tag-port-machinery","tag-power-plant-cable","tag-rail-mounted-gantry","tag-reeling-cable","tag-reeling-cable-installation-best-practices","tag-reeling-drum-cable-selection","tag-renewable-energy-cable","tag-rubber-sheathed-cable","tag-ship-to-shore-crane-cable-2","tag-shipbuilding-cable","tag-spring-cable-reel","tag-spring-operated-reeling-drum","tag-sprocket-driven-reeling-drum","tag-stacker-reclaimer","tag-steel-mill-equipment","tag-steel-plant-cable","tag-sts-crane-cable","tag-textile-mesh-in-cable-construction","tag-torque-controlled-reeling-drum","tag-torsion-resistant-cable","tag-trailing-cable","tag-transfer-car-cable","tag-vde-0472","tag-vde-0482","tag-22788","tag-22163","tag-32744","tag-32745","tag-22736","tag-32135","tag-32742","tag-31878","tag-32743","tag-11984","tag-31718","tag-32746","tag-32741","tag-22977","tag-32740","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4922","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=4922"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4922\/revisions"}],"predecessor-version":[{"id":4924,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4922\/revisions\/4924"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/4923"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=4922"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=4922"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=4922"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}