{"id":4880,"date":"2026-01-22T15:10:16","date_gmt":"2026-01-22T07:10:16","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=4880"},"modified":"2026-01-22T15:11:40","modified_gmt":"2026-01-22T07:11:40","slug":"can-ntscgewou-cables-be-used-for-vertical-drum-reeling-e-g-spreader-without-modification","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/can-ntscgewou-cables-be-used-for-vertical-drum-reeling-e-g-spreader-without-modification\/","title":{"rendered":"Can (N)TSCGEW\u00d6U cables be used for &#8220;Vertical Drum Reeling&#8221; (e.g., Spreader) without modification?"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"7f8a81\" data-has-transparency=\"false\" style=\"--dominant-color: #7f8a81;\" loading=\"lazy\" decoding=\"async\" width=\"996\" height=\"491\" sizes=\"auto, (max-width: 996px) 100vw, 996px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-569.avif\" alt=\"\" class=\"wp-image-4881 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-569.avif 996w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-569-300x148.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-569-768x379.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-569-400x197.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-569-800x394.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-569-832x410.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>Engineering FAQ: Can (N)TSCGEW\u00d6U cables be used for &#8220;Vertical Drum Reeling&#8221; (e.g., Spreader) without modification?<\/title>\n<style>\n    \/* * INDUSTRIAL STYLE-NEUTRAL CSS *\n     * Designed to inherit the parent website's colors (Light\/Dark Mode).\n     * Focuses on structural integrity, professional typography, and data readability.\n     * No fixed colors are used to ensure zero conflict with your theme.\n     *\/\n    \n    .industrial-container {\n        width: 100%;\n        max-width: 100%;\n        margin: 0 auto;\n        font-family: system-ui, -apple-system, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n        line-height: 1.8;\n        word-wrap: break-word;\n    }\n\n    \/* HEADERS *\/\n    .industrial-container h1 {\n        font-size: 2.6rem;\n        font-weight: 800;\n        margin-top: 2.5rem;\n        margin-bottom: 1.5rem;\n        border-bottom: 5px solid currentColor;\n        padding-bottom: 20px;\n        text-transform: uppercase;\n        letter-spacing: -0.5px;\n    }\n\n    .industrial-container h2 {\n        font-size: 2rem;\n        font-weight: 700;\n        margin-top: 4rem;\n        margin-bottom: 1.5rem;\n        border-left: 8px solid currentColor;\n        padding-left: 20px;\n    }\n\n    .industrial-container h3 {\n        font-size: 1.5rem;\n        font-weight: 600;\n        margin-top: 2.5rem;\n        margin-bottom: 1rem;\n        text-decoration: underline;\n        text-decoration-style: dotted;\n    }\n\n    \/* BILINGUAL BLOCKS *\/\n    .bilingual-wrapper {\n        margin-bottom: 40px;\n        padding-bottom: 30px;\n        border-bottom: 1px dashed currentColor;\n    }\n\n    .en-content {\n        display: block;\n        font-size: 1.15rem;\n        font-weight: 500;\n        margin-bottom: 15px;\n        line-height: 1.7;\n    }\n\n    .cn-content {\n        display: block;\n        font-size: 1.05rem;\n        opacity: 0.85; \/* Uses opacity for hierarchy, avoiding fixed colors *\/\n        font-weight: 400;\n        line-height: 1.6;\n        margin-top: 10px;\n    }\n\n    \/* TECHNICAL TABLES *\/\n    .spec-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 50px 0;\n        font-size: 1rem;\n    }\n\n    .spec-table th, .spec-table td {\n        border: 1px solid currentColor;\n        padding: 18px;\n        vertical-align: top;\n        text-align: left;\n    }\n\n    .spec-table th {\n        text-transform: uppercase;\n        font-weight: 900;\n        border-bottom: 3px solid currentColor;\n        \/* Background shading via transparency *\/\n        background-color: rgba(125, 125, 125, 0.1); \n    }\n\n    \/* INFO BOXES *\/\n    .tech-box {\n        border: 2px solid currentColor;\n        padding: 30px;\n        margin: 40px 0;\n    }\n\n    .box-label {\n        text-transform: uppercase;\n        font-weight: 800;\n        display: block;\n        margin-bottom: 10px;\n        border-bottom: 1px solid currentColor;\n        width: fit-content;\n    }\n    \n    .warning-box {\n        border: 4px solid currentColor;\n        padding: 20px;\n        margin: 30px 0;\n        font-weight: bold;\n        text-align: center;\n    }\n\n    \/* CONTACT SECTION *\/\n    .contact-block {\n        border-top: 4px double currentColor;\n        border-bottom: 4px double currentColor;\n        padding: 50px 20px;\n        margin-top: 100px;\n        text-align: center;\n    }\n\n    .contact-details {\n        display: grid;\n        grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n        gap: 40px;\n        margin-top: 40px;\n        text-align: left;\n    }\n\n    .contact-row strong {\n        display: block;\n        text-transform: uppercase;\n        font-size: 0.85rem;\n        opacity: 0.7;\n        margin-bottom: 8px;\n        letter-spacing: 1px;\n    }\n\n    .contact-row a {\n        font-size: 1.25rem;\n        font-weight: 700;\n        text-decoration: none;\n        border-bottom: 2px solid currentColor;\n    }\n\n    \/* CITATION *\/\n    .references {\n        font-size: 0.9rem;\n        margin-top: 50px;\n        opacity: 0.8;\n        padding: 20px;\n        border: 1px dotted currentColor;\n    }\n\n    \/* LISTS *\/\n    ul.industrial-list {\n        list-style-type: square;\n        padding-left: 20px;\n    }\n    \n    ul.industrial-list li {\n        margin-bottom: 15px;\n    }\n\n    \/* IMAGES *\/\n    img {\n        max-width: 100%;\n        height: auto;\n        display: block;\n        margin: 40px auto;\n        border: 1px solid currentColor;\n        padding: 5px;\n    }\n<\/style>\n<\/head>\n<body>\n\n<div class=\"industrial-container\">\n\n    <header>\n        <h1>Engineering Inquiry: Can (N)TSCGEW\u00d6U cables be used for &#8220;Vertical Drum Reeling&#8221; (e.g., Spreader) without modification?<\/h1>\n        <p><strong>Published by: Anhui Feichun Special Cable Co., Ltd.<\/strong><br>\n        <em>Specialists in High-Tensile Cabling Solutions<\/em><\/p>\n    <\/header>\n\n    \n\n    <section>\n        <h2>1. Executive Summary: The Risk of Gravity<\/h2>\n        \n        <div class=\"bilingual-wrapper\">\n            <span class=\"en-content\">The short answer is: <strong>Only for very limited lengths and speeds.<\/strong> For typical industrial Spreader or Vertical Lift applications, standard (N)TSCGEW\u00d6U cables are <strong>NOT recommended<\/strong> without modification. While (N)TSCGEW\u00d6U is designed for high dynamic stress, it is primarily optimized for <em>horizontal<\/em> reeling where the cable weight is supported by the ground or rollers. In vertical applications, the entire weight of the suspended cable (plus acceleration forces) hangs directly on the copper conductors. Without a dedicated tensile support element (like Aramid or Steel), this often exceeds the <strong>VDE Safety Limit of 15 N\/mm\u00b2<\/strong>, leading to conductor elongation, breakage, and &#8220;corkscrewing.&#8221;<\/span>\n            <span class=\"cn-content\">\u7b80\u77ed\u7684\u56de\u7b54\u662f\uff1a<strong>\u4ec5\u9002\u7528\u4e8e\u975e\u5e38\u6709\u9650\u7684\u957f\u5ea6\u548c\u901f\u5ea6\u3002<\/strong> \u5bf9\u4e8e\u5178\u578b\u7684\u5de5\u4e1a\u540a\u5177\u6216\u5782\u76f4\u5347\u964d\u5e94\u7528\uff0c<strong>\u4e0d\u63a8\u8350<\/strong>\u4f7f\u7528\u672a\u7ecf\u4fee\u6539\u7684\u6807\u51c6 (N)TSCGEW\u00d6U \u7535\u7f06\u3002\u867d\u7136 (N)TSCGEW\u00d6U \u4e13\u4e3a\u9ad8\u52a8\u6001\u5e94\u529b\u8bbe\u8ba1\uff0c\u4f46\u5b83\u4e3b\u8981\u9488\u5bf9<em>\u6c34\u5e73<\/em>\u5377\u7ed5\u8fdb\u884c\u4e86\u4f18\u5316\uff0c\u6b64\u65f6\u7535\u7f06\u91cd\u91cf\u7531\u5730\u9762\u6216\u6eda\u8f6e\u652f\u6491\u3002\u5728\u5782\u76f4\u5e94\u7528\u4e2d\uff0c\u60ac\u6302\u7535\u7f06\u7684\u5168\u90e8\u91cd\u91cf\uff08\u52a0\u4e0a\u52a0\u901f\u5ea6\u529b\uff09\u76f4\u63a5\u60ac\u6302\u5728\u94dc\u5bfc\u4f53\u4e0a\u3002\u5982\u679c\u6ca1\u6709\u4e13\u7528\u7684\u62c9\u4f38\u652f\u6491\u5143\u4ef6\uff08\u5982\u82b3\u7eb6\u6216\u94a2\uff09\uff0c\u8fd9\u901a\u5e38\u4f1a\u8d85\u8fc7 <strong>15 N\/mm\u00b2 \u7684 VDE \u5b89\u5168\u6781\u9650<\/strong>\uff0c\u5bfc\u81f4\u5bfc\u4f53\u4f38\u957f\u3001\u65ad\u88c2\u548c\u201c\u87ba\u65cb\u53d8\u5f62\u201d\u3002<\/span>\n        <\/div>\n    <\/section>\n\n    <section>\n        <h2>2. Physics of Failure: Horizontal vs. Vertical<\/h2>\n        \n        <div class=\"tech-box\">\n            <span class=\"box-label\">Horizontal Reeling (Standard Use)<\/span>\n            <p>In a standard gantry crane application, the cable lays on the ground. The Reel Motor only needs to pull enough tension to lift the cable off the ground and wrap it. The tensile load is relatively low.<\/p>\n            <p class=\"cn-content\">\u5728\u6807\u51c6\u7684\u95e8\u5f0f\u8d77\u91cd\u673a\u5e94\u7528\u4e2d\uff0c\u7535\u7f06\u94fa\u8bbe\u5728\u5730\u9762\u4e0a\u3002\u5377\u76d8\u7535\u673a\u53ea\u9700\u62c9\u52a8\u8db3\u591f\u7684\u5f20\u529b\u5c06\u7535\u7f06\u4ece\u5730\u9762\u63d0\u8d77\u5e76\u5377\u7ed5\u3002\u62c9\u4f38\u8d1f\u8377\u76f8\u5bf9\u8f83\u4f4e\u3002<\/p>\n        <\/div>\n\n        <div class=\"tech-box\">\n            <span class=\"box-label\">Vertical Reeling (Spreader Use)<\/span>\n            <p>In a Spreader application, the cable hangs vertically.\n            <br><strong>Tensile Force ($F_t$) = Weight of Cable ($m \\times g$) + Acceleration Force ($m \\times a$).<\/strong>\n            <br>Standard copper conductors have a low yield strength. If the calculated tension exceeds <strong>20 N\/mm\u00b2<\/strong> (Total Copper Cross-Section), the copper begins to stretch permanently (plastic deformation). This stretches the copper <em>inside<\/em> the rubber sheath, causing the cable to twist and deform (Corkscrew) as the excess copper tries to find space.<\/p>\n            <p class=\"cn-content\">\u5728\u540a\u5177\u5e94\u7528\u4e2d\uff0c\u7535\u7f06\u5782\u76f4\u60ac\u6302\u3002<br><strong>\u62c9\u529b ($F_t$) = \u7535\u7f06\u91cd\u91cf ($m \\times g$) + \u52a0\u901f\u5ea6\u529b ($m \\times a$)\u3002<\/strong><br>\u6807\u51c6\u94dc\u5bfc\u4f53\u7684\u5c48\u670d\u5f3a\u5ea6\u8f83\u4f4e\u3002\u5982\u679c\u8ba1\u7b97\u51fa\u7684\u5f20\u529b\u8d85\u8fc7 <strong>20 N\/mm\u00b2<\/strong>\uff08\u603b\u94dc\u622a\u9762\u79ef\uff09\uff0c\u94dc\u5f00\u59cb\u53d1\u751f\u6c38\u4e45\u4f38\u957f\uff08\u5851\u6027\u53d8\u5f62\uff09\u3002\u8fd9\u4f1a\u5728\u6a61\u80f6\u62a4\u5957<em>\u5185\u90e8<\/em>\u62c9\u4f38\u94dc\uff0c\u968f\u7740\u591a\u4f59\u7684\u94dc\u8bd5\u56fe\u5bfb\u627e\u7a7a\u95f4\uff0c\u5bfc\u81f4\u7535\u7f06\u626d\u66f2\u53d8\u5f62\uff08\u87ba\u65cb\u53d8\u5f62\uff09\u3002<\/p>\n        <\/div>\n    <\/section>\n\n    \n\n    <section>\n        <h2>3. When is Modification Required? (Calculation Rule)<\/h2>\n        \n        <p>You can use standard (N)TSCGEW\u00d6U <strong>IF AND ONLY IF<\/strong> the tensile load is low.<\/p>\n\n        <table class=\"spec-table\">\n            <thead>\n                <tr>\n                    <th>Parameter (\u53c2\u6570)<\/th>\n                    <th>Standard (N)TSCGEW\u00d6U<br>(No Modification)<\/th>\n                    <th>Modified (N)TSCGEW\u00d6U-V \/ (N)TSZCGEW\u00d6U<br>(With Strain Relief)<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td><strong>Max Tensile Stress<\/strong><br>\u6700\u5927\u62c9\u4f38\u5e94\u529b<\/td>\n                    <td><strong>< 15 N\/mm\u00b2<\/strong><br>(Safe Limit)<br><span class=\"cn-content\"><strong>< 15 N\/mm\u00b2<\/strong><br>\uff08\u5b89\u5168\u6781\u9650\uff09<\/span><\/td>\n                    <td><strong>> 20 N\/mm\u00b2<\/strong><br>(Requires Support)<br><span class=\"cn-content\"><strong>> 20 N\/mm\u00b2<\/strong><br>\uff08\u9700\u8981\u652f\u6491\uff09<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Typical Vertical Length<\/strong><br>\u5178\u578b\u5782\u76f4\u957f\u5ea6<\/td>\n                    <td><strong>Max 30-50 Meters<\/strong><br>(Depending on cable weight)<br><span class=\"cn-content\"><strong>\u6700\u5927 30-50 \u7c73<\/strong><br>\uff08\u53d6\u51b3\u4e8e\u7535\u7f06\u91cd\u91cf\uff09<\/span><\/td>\n                    <td><strong>Up to 200+ Meters<\/strong><br>(Load carried by Aramid\/Steel)<br><span class=\"cn-content\"><strong>\u9ad8\u8fbe 200+ \u7c73<\/strong><br>\uff08\u7531\u82b3\u7eb6\/\u94a2\u627f\u53d7\u8d1f\u8f7d\uff09<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Acceleration<\/strong><br>\u52a0\u901f\u5ea6<\/td>\n                    <td>Low (< 0.5 m\/s\u00b2)<br><span class=\"cn-content\">\u4f4e (< 0.5 m\/s\u00b2)<\/span><\/td>\n                    <td>High (> 1.0 m\/s\u00b2)<br><span class=\"cn-content\">\u9ad8 (> 1.0 m\/s\u00b2)<\/span><\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n        \n        <div class=\"warning-box\">\n            CRITICAL: If your calculation shows tension > 15 N\/mm\u00b2, you MUST use a cable with a Central Strain Relief Member (usually designated with &#8220;-V&#8221; or &#8220;Z&#8221;).\n            <br><span class=\"cn-content\">\u5173\u952e\u63d0\u793a\uff1a\u5982\u679c\u60a8\u7684\u8ba1\u7b97\u663e\u793a\u5f20\u529b > 15 N\/mm\u00b2\uff0c\u60a8\u5fc5\u987b\u4f7f\u7528\u5e26\u6709\u4e2d\u592e\u5e94\u529b\u6d88\u9664\u6784\u4ef6\u7684\u7535\u7f06\uff08\u901a\u5e38\u6807\u8bb0\u4e3a\u201c-V\u201d\u6216\u201cZ\u201d\uff09\u3002<\/span>\n        <\/div>\n    <\/section>\n\n    <section>\n        <h2>4. The Anhui Feichun Solution: (N)TSZCGEW\u00d6U<\/h2>\n        \n        <div class=\"bilingual-wrapper\">\n            <span class=\"en-content\">To handle vertical spreader applications safely, Anhui Feichun manufactures a modified version often coded as <strong>(N)TSZCGEW\u00d6U<\/strong> (where &#8220;Z&#8221; stands for <em>Zugentlastung<\/em> &#8211; Strain Relief).\n            <br>This cable features a <strong>Central Aramid (Kevlar) Core<\/strong>. The Aramid fibers have a tensile strength 5x higher than steel by weight. The entire weight of the cable is clamped to this central core at the termination points, leaving the sensitive copper conductors completely stress-free.<\/span>\n            <span class=\"cn-content\">\u4e3a\u4e86\u5b89\u5168\u5730\u5904\u7406\u5782\u76f4\u540a\u5177\u5e94\u7528\uff0c\u5b89\u5fbd\u98de\u7eaf\u751f\u4ea7\u4e00\u79cd\u6539\u8fdb\u7248\u672c\uff0c\u901a\u5e38\u7f16\u7801\u4e3a <strong>(N)TSZCGEW\u00d6U<\/strong>\uff08\u5176\u4e2d\u201cZ\u201d\u4ee3\u8868 <em>Zugentlastung<\/em> &#8211; \u5e94\u529b\u6d88\u9664\uff09\u3002<br>\u8be5\u7535\u7f06\u5177\u6709<strong>\u4e2d\u592e\u82b3\u7eb6 (Kevlar) \u82af<\/strong>\u3002\u82b3\u7eb6\u7ea4\u7ef4\u7684\u5355\u4f4d\u91cd\u91cf\u6297\u62c9\u5f3a\u5ea6\u662f\u94a2\u7684 5 \u500d\u3002\u7535\u7f06\u7684\u5168\u90e8\u91cd\u91cf\u5728\u7ec8\u7aef\u70b9\u88ab\u5939\u7d27\u5230\u8fd9\u4e2a\u4e2d\u5fc3\u82af\u4e0a\uff0c\u4f7f\u654f\u611f\u7684\u94dc\u5bfc\u4f53\u5b8c\u5168\u6ca1\u6709\u5e94\u529b\u3002<\/span>\n        <\/div>\n\n        <ul class=\"industrial-list\">\n            <li><strong>Reduced Diameter:<\/strong> Aramid allows us to keep the cable compact compared to steel ropes.<\/li>\n            <li><strong>Torsion Free:<\/strong> The central element prevents the cable from spinning under load.<\/li>\n        <\/ul>\n    <\/section>\n\n    <div class=\"contact-block\">\n        <h3>Contact Anhui Feichun Special Cable Co., Ltd.<\/h3>\n        <p><strong>Free Tensile Load Calculation for Your Vertical Application<\/strong><\/p>\n        \n        <div class=\"contact-details\">\n            <div class=\"contact-row\">\n                <strong>Technical Engineering Dept.<\/strong>\n                <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n            <\/div>\n            <div class=\"contact-row\">\n                <strong>International Sales (Zihao Yang)<\/strong>\n                <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a>\n            <\/div>\n            <div class=\"contact-row\">\n                <strong>International Sales (Ziyu Huang)<\/strong>\n                <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a>\n            <\/div>\n            <div class=\"contact-row\">\n                <strong>WhatsApp \/ 24h Support<\/strong>\n                <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 13855123218<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n\n    <div class=\"references\">\n        <h4>Authoritative References &#038; Standards:<\/h4>\n        <ul>\n            <li><a href=\"#\" rel=\"nofollow\">DIN VDE 0298-3: Application of cables and cords in power installations &#8211; Guide to use (Tensile Limits).<\/a><\/li>\n            <li><a href=\"#\" rel=\"nofollow\">DIN VDE 0250-813: Medium voltage reeling cables.<\/a><\/li>\n            <li><a href=\"#\" rel=\"nofollow\">IEC 60228: Conductors of insulated cables.<\/a><\/li>\n        <\/ul>\n    <\/div>\n\n<\/div>\n\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"(N)TSCGEW\u00d6U vertical reeling limits, VDE 0298-3 tensile load calculation, spreader cable vs reeling cable, vertical drum application cable, Anhui Feichun Special Cable, cable corkscrewing causes, central strain relief aramid, high tensile strength rubber cable, STS crane spreader cable, vertical lift power supply, medium voltage reeling cable specs, copper conductor yield strength, heavy duty port machinery cable, torsional stress in vertical cables, (N)TSCGEW\u00d6U-V meaning, preventing cable elongation, gantry crane hoist cable, DIN VDE 0250-813 standard","protected":false},"author":1,"featured_media":4881,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[35,9563,1,56],"tags":[32520,32530,2484,32523,32524,32528,1670,32531,152,32266,32521,32532,32533,32526,30625,32529,32525,32522,32527],"class_list":["post-4880","post","type-post","status-publish","format-standard","has-post-thumbnail","category-festoon-cable","category-medium-voltage-cable","category-uncategorized","category-reeling-cable","tag-ntscgewou-vertical-reeling-limits","tag-ntscgewou-v-meaning","tag-anhui-feichun-special-cable","tag-cable-corkscrewing-causes","tag-central-strain-relief-aramid","tag-copper-conductor-yield-strength","tag-din-vde-0250-813-standard","tag-gantry-crane-hoist-cable","tag-heavy-duty-mining-cable","tag-heavy-duty-port-machinery-cable","tag-high-tensile-strength-rubber-cable","tag-medium-voltage-reeling-cable-specs","tag-preventing-cable-elongation","tag-spreader-cable-vs-reeling-cable","tag-sts-crane-spreader-cable","tag-torsional-stress-in-vertical-cables","tag-vde-0298-3-tensile-load-calculation","tag-vertical-drum-application-cable","tag-vertical-lift-power-supply","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4880","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=4880"}],"version-history":[{"count":3,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4880\/revisions"}],"predecessor-version":[{"id":4886,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4880\/revisions\/4886"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/4881"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=4880"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=4880"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=4880"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}