{"id":4876,"date":"2026-01-22T14:58:24","date_gmt":"2026-01-22T06:58:24","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=4876"},"modified":"2026-01-22T14:58:28","modified_gmt":"2026-01-22T06:58:28","slug":"what-is-the-difference-between-a-festoon-cable-application-and-a-reeling-application-under-vde-selection-guidelines","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/what-is-the-difference-between-a-festoon-cable-application-and-a-reeling-application-under-vde-selection-guidelines\/","title":{"rendered":"What is the difference between a &#8220;Festoon&#8221; cable application and a &#8220;Reeling&#8221; application under VDE selection guidelines?"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"6e7977\" data-has-transparency=\"false\" style=\"--dominant-color: #6e7977;\" loading=\"lazy\" decoding=\"async\" width=\"1001\" height=\"628\" sizes=\"auto, (max-width: 1001px) 100vw, 1001px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568-1001x628.avif\" alt=\"\" class=\"wp-image-4877 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568-1001x628.avif 1001w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568-300x188.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568-768x482.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568-400x251.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568-800x502.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568-832x522.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-568.avif 1140w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>Technical Engineering Guide: Festoon vs. Reeling Cable Applications (VDE Guidelines)<\/title>\n<style>\n    \/* * INDUSTRIAL STYLE-NEUTRAL CSS *\n     * Designed to inherit the parent website's colors (Light\/Dark Mode).\n     * Focuses on structural integrity, professional typography, and data readability.\n     * No fixed colors are used to ensure zero conflict with your theme.\n     *\/\n    \n    .industrial-container {\n        width: 100%;\n        max-width: 100%;\n        margin: 0 auto;\n        font-family: system-ui, -apple-system, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n        line-height: 1.8;\n        word-wrap: break-word;\n    }\n\n    \/* HEADERS *\/\n    .industrial-container h1 {\n        font-size: 2.6rem;\n        font-weight: 800;\n        margin-top: 2.5rem;\n        margin-bottom: 1.5rem;\n        border-bottom: 5px solid currentColor;\n        padding-bottom: 20px;\n        text-transform: uppercase;\n        letter-spacing: -0.5px;\n    }\n\n    .industrial-container h2 {\n        font-size: 2rem;\n        font-weight: 700;\n        margin-top: 4rem;\n        margin-bottom: 1.5rem;\n        border-left: 8px solid currentColor;\n        padding-left: 20px;\n    }\n\n    .industrial-container h3 {\n        font-size: 1.5rem;\n        font-weight: 600;\n        margin-top: 2.5rem;\n        margin-bottom: 1rem;\n        text-decoration: underline;\n        text-decoration-style: dotted;\n    }\n\n    \/* BILINGUAL BLOCKS *\/\n    .bilingual-wrapper {\n        margin-bottom: 40px;\n        padding-bottom: 30px;\n        border-bottom: 1px dashed currentColor;\n    }\n\n    .en-content {\n        display: block;\n        font-size: 1.15rem;\n        font-weight: 500;\n        margin-bottom: 15px;\n        line-height: 1.7;\n    }\n\n    .cn-content {\n        display: block;\n        font-size: 1.05rem;\n        opacity: 0.85; \/* Uses opacity for hierarchy, avoiding fixed colors *\/\n        font-weight: 400;\n        line-height: 1.6;\n        margin-top: 10px;\n    }\n\n    \/* TECHNICAL TABLES *\/\n    .spec-table {\n        width: 100%;\n        border-collapse: collapse;\n        margin: 50px 0;\n        font-size: 1rem;\n    }\n\n    .spec-table th, .spec-table td {\n        border: 1px solid currentColor;\n        padding: 18px;\n        vertical-align: top;\n        text-align: left;\n    }\n\n    .spec-table th {\n        text-transform: uppercase;\n        font-weight: 900;\n        border-bottom: 3px solid currentColor;\n        \/* Background shading via transparency *\/\n        background-color: rgba(125, 125, 125, 0.1); \n    }\n\n    \/* INFO BOXES *\/\n    .tech-box {\n        border: 2px solid currentColor;\n        padding: 30px;\n        margin: 40px 0;\n    }\n\n    .box-label {\n        text-transform: uppercase;\n        font-weight: 800;\n        display: block;\n        margin-bottom: 10px;\n        border-bottom: 1px solid currentColor;\n        width: fit-content;\n    }\n\n    \/* CONTACT SECTION *\/\n    .contact-block {\n        border-top: 4px double currentColor;\n        border-bottom: 4px double currentColor;\n        padding: 50px 20px;\n        margin-top: 100px;\n        text-align: center;\n    }\n\n    .contact-details {\n        display: grid;\n        grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n        gap: 40px;\n        margin-top: 40px;\n        text-align: left;\n    }\n\n    .contact-row strong {\n        display: block;\n        text-transform: uppercase;\n        font-size: 0.85rem;\n        opacity: 0.7;\n        margin-bottom: 8px;\n        letter-spacing: 1px;\n    }\n\n    .contact-row a {\n        font-size: 1.25rem;\n        font-weight: 700;\n        text-decoration: none;\n        border-bottom: 2px solid currentColor;\n    }\n\n    \/* CITATION *\/\n    .references {\n        font-size: 0.9rem;\n        margin-top: 50px;\n        opacity: 0.8;\n        padding: 20px;\n        border: 1px dotted currentColor;\n    }\n\n    \/* LISTS *\/\n    ul.industrial-list {\n        list-style-type: square;\n        padding-left: 20px;\n    }\n    \n    ul.industrial-list li {\n        margin-bottom: 15px;\n    }\n\n    \/* IMAGES *\/\n    img {\n        max-width: 100%;\n        height: auto;\n        display: block;\n        margin: 40px auto;\n        border: 1px solid currentColor;\n        padding: 5px;\n    }\n<\/style>\n<\/head>\n<body>\n\n<div class=\"industrial-container\">\n\n    <header>\n        <h1>Engineering Guide: What is the difference between a &#8220;Festoon&#8221; cable application and a &#8220;Reeling&#8221; application under VDE selection guidelines?<\/h1>\n        <p><strong>Published by: Anhui Feichun Special Cable Co., Ltd.<\/strong><br>\n        <em>Experts in Port Machinery Electrification and Cable Dynamics<\/em><\/p>\n    <\/header>\n\n    \n\n    <section>\n        <h2>1. Executive Summary: The Mechanics of Movement<\/h2>\n        \n        <div class=\"bilingual-wrapper\">\n            <span class=\"en-content\">In the material handling industry (cranes, mining, ports), moving machinery requires power. The two primary methods for delivering this power are <strong>Festoon Systems<\/strong> (Cable Trolleys) and <strong>Reeling Systems<\/strong> (Cable Drums). While both use flexible rubber cables, the mechanical stresses applied to the cables are fundamentally different. According to <strong>DIN VDE 0298-3<\/strong>, selecting the wrong cable type (e.g., using a festoon cable on a reel) will lead to catastrophic failure due to torsion or tensile overload.<\/span>\n            <span class=\"cn-content\">\u5728\u7269\u6599\u642c\u8fd0\u7cfb\u7edf\u884c\u4e1a\uff08\u8d77\u91cd\u673a\u3001\u91c7\u77ff\u3001\u6e2f\u53e3\uff09\u4e2d\uff0c\u79fb\u52a8\u673a\u68b0\u9700\u8981\u52a8\u529b\u3002\u4f20\u8f93\u52a8\u529b\u7684\u4e24\u79cd\u4e3b\u8981\u65b9\u6cd5\u662f<strong>\u62d6\u4ee4\u7cfb\u7edf<\/strong>\uff08\u7535\u7f06\u5c0f\u8f66\uff09\u548c<strong>\u5377\u76d8\u7cfb\u7edf<\/strong>\uff08\u7535\u7f06\u5377\u7b52\uff09\u3002\u867d\u7136\u4e24\u8005\u90fd\u4f7f\u7528\u67d4\u6027\u6a61\u80f6\u7535\u7f06\uff0c\u4f46\u65bd\u52a0\u5728\u7535\u7f06\u4e0a\u7684\u673a\u68b0\u5e94\u529b\u6709\u7740\u6839\u672c\u7684\u4e0d\u540c\u3002\u6839\u636e <strong>DIN VDE 0298-3<\/strong>\uff0c\u9009\u62e9\u9519\u8bef\u7684\u7535\u7f06\u7c7b\u578b\uff08\u4f8b\u5982\uff0c\u5728\u5377\u76d8\u4e0a\u4f7f\u7528\u62d6\u4ee4\u7535\u7f06\uff09\u5c06\u56e0\u626d\u8f6c\u6216\u62c9\u4f38\u8fc7\u8f7d\u800c\u5bfc\u81f4\u707e\u96be\u6027\u6545\u969c\u3002<\/span>\n        <\/div>\n    <\/section>\n\n    <section>\n        <h2>2. Festoon Systems (Cable Trolleys)<\/h2>\n        \n        <div class=\"tech-box\">\n            <span class=\"box-label\">Definition &#038; Stress Profile<\/span>\n            <p><strong>Mechanism:<\/strong> Cables hang in loops (festoons) supported by trolleys that run along a C-track or I-beam. As the crane moves, the trolleys gather (compress) or spread out (extend).<\/p>\n            <p><strong>Primary Stress:<\/strong> <strong>Bending (Flexing).<\/strong> The cable is bent and straightened repeatedly at the bottom of the loop. There is very little tensile (pulling) load on the copper, as the trolleys carry the weight.<\/p>\n            <p><strong>Ideal Cable Geometry:<\/strong> <strong>Flat Cables (Flachleitung).<\/strong> Flat cables like <strong>(N)GRDG\u00d6U<\/strong> or <strong>(N)GFLG\u00d6U<\/strong> are preferred because they bend easily in one plane and can be stacked efficiently without twisting.<\/p>\n            <p class=\"cn-content\"><strong>\u673a\u5236\uff1a<\/strong> \u7535\u7f06\u4ee5\u73af\u5f62\uff08\u5782\u5f62\uff09\u60ac\u6302\uff0c\u7531\u6cbf\u7740 C \u578b\u8f68\u9053\u6216\u5de5\u5b57\u94a2\u8fd0\u884c\u7684\u5c0f\u8f66\u652f\u6491\u3002\u5f53\u8d77\u91cd\u673a\u79fb\u52a8\u65f6\uff0c\u5c0f\u8f66\u805a\u96c6\uff08\u538b\u7f29\uff09\u6216\u5c55\u5f00\uff08\u5ef6\u4f38\uff09\u3002<br><strong>\u4e3b\u8981\u5e94\u529b\uff1a<\/strong> <strong>\u5f2f\u66f2\uff08\u5c48\u6320\uff09\u3002<\/strong> \u7535\u7f06\u5728\u73af\u7684\u5e95\u90e8\u53cd\u590d\u5f2f\u66f2\u548c\u4f38\u76f4\u3002\u94dc\u5bfc\u4f53\u4e0a\u7684\u62c9\u4f38\uff08\u62c9\u529b\uff09\u8d1f\u8377\u975e\u5e38\u5c0f\uff0c\u56e0\u4e3a\u5c0f\u8f66\u627f\u53d7\u4e86\u91cd\u91cf\u3002<br><strong>\u7406\u60f3\u7535\u7f06\u51e0\u4f55\u5f62\u72b6\uff1a<\/strong> <strong>\u6241\u5e73\u7535\u7f06 (Flachleitung)\u3002<\/strong> \u6241\u5e73\u7535\u7f06\u5982 <strong>(N)GRDG\u00d6U<\/strong> \u6216 <strong>(N)GFLG\u00d6U<\/strong> \u662f\u9996\u9009\uff0c\u56e0\u4e3a\u5b83\u4eec\u6613\u4e8e\u5728\u4e00\u4e2a\u5e73\u9762\u5185\u5f2f\u66f2\uff0c\u5e76\u4e14\u53ef\u4ee5\u9ad8\u6548\u5806\u53e0\u800c\u4e0d\u4f1a\u626d\u66f2\u3002<\/p>\n        <\/div>\n\n        <ul class=\"industrial-list\">\n            <li><strong>Anhui Feichun Recommended Models:<\/strong> (N)GRDG\u00d6U (Rubber Flat), H07VVH6-F (PVC Flat for indoor).<\/li>\n            <li><strong>Key VDE Parameter:<\/strong> Minimum Bending Radius (typically 3-5x Cable Thickness).<\/li>\n        <\/ul>\n    <\/section>\n    \n    \n\n    <section>\n        <h2>3. Reeling Systems (Cable Drums)<\/h2>\n        \n        <div class=\"tech-box\">\n            <span class=\"box-label\">Definition &#038; Stress Profile<\/span>\n            <p><strong>Mechanism:<\/strong> The cable is wound onto a large motorized or spring-driven cylindrical drum. The drum pulls the cable off the ground as the machine moves.<\/p>\n            <p><strong>Primary Stress:<\/strong> <strong>Tension (Tensile Load) + Torsion (Twisting).<\/strong> The cable must withstand the pulling force of the drum. Furthermore, winding a cable inherently introduces a twisting force.<\/p>\n            <p><strong>Ideal Cable Geometry:<\/strong> <strong>Round Cables with Anti-Torsion Braid.<\/strong> Flat cables are rarely used on drums (except specialized designs). Round cables like <strong>(N)TSCGEW\u00d6U<\/strong> are mandatory. They MUST feature an internal textile or aramid braid to prevent &#8220;corkscrewing&#8221; (structural deformation).<\/p>\n            <p class=\"cn-content\"><strong>\u673a\u5236\uff1a<\/strong> \u7535\u7f06\u7f20\u7ed5\u5728\u4e00\u4e2a\u5927\u578b\u7535\u52a8\u6216\u5f39\u7c27\u9a71\u52a8\u7684\u5706\u67f1\u5f62\u5377\u7b52\u4e0a\u3002\u5f53\u673a\u5668\u79fb\u52a8\u65f6\uff0c\u5377\u7b52\u5c06\u7535\u7f06\u4ece\u5730\u9762\u62c9\u8d77\u3002<br><strong>\u4e3b\u8981\u5e94\u529b\uff1a<\/strong> <strong>\u5f20\u529b\uff08\u62c9\u4f38\u8d1f\u8377\uff09+ \u626d\u8f6c\uff08\u626d\u66f2\uff09\u3002<\/strong> \u7535\u7f06\u5fc5\u987b\u627f\u53d7\u5377\u7b52\u7684\u62c9\u529b\u3002\u6b64\u5916\uff0c\u7f20\u7ed5\u7535\u7f06\u672c\u8d28\u4e0a\u4f1a\u5f15\u5165\u626d\u8f6c\u529b\u3002<br><strong>\u7406\u60f3\u7535\u7f06\u51e0\u4f55\u5f62\u72b6\uff1a<\/strong> <strong>\u5e26\u6709\u6297\u626d\u8f6c\u7f16\u7ec7\u5c42\u7684\u5706\u5f62\u7535\u7f06\u3002<\/strong> \u6241\u5e73\u7535\u7f06\u5f88\u5c11\u7528\u4e8e\u5377\u7b52\uff08\u7279\u6b8a\u8bbe\u8ba1\u9664\u5916\uff09\u3002\u5fc5\u987b\u4f7f\u7528\u50cf <strong>(N)TSCGEW\u00d6U<\/strong> \u8fd9\u6837\u7684\u5706\u5f62\u7535\u7f06\u3002\u5b83\u4eec\u5fc5\u987b\u5177\u6709\u5185\u90e8\u7eba\u7ec7\u6216\u82b3\u7eb6\u7f16\u7ec7\u5c42\uff0c\u4ee5\u9632\u6b62\u201c\u87ba\u65cb\u53d8\u5f62\u201d\uff08\u7ed3\u6784\u53d8\u5f62\uff09\u3002<\/p>\n        <\/div>\n\n        <ul class=\"industrial-list\">\n            <li><strong>Anhui Feichun Recommended Models:<\/strong> (N)TSCGEW\u00d6U (HV), (N)SHT\u00d6U (LV), (N)TSKCGEW\u00d6U.<\/li>\n            <li><strong>Key VDE Parameter:<\/strong> Maximum Tensile Load (typically 15-20 N\/mm\u00b2 dynamic).<\/li>\n        <\/ul>\n    <\/section>\n\n    \n\n    <section>\n        <h2>4. Technical Comparison Table (VDE Guidelines)<\/h2>\n\n        <table class=\"spec-table\">\n            <thead>\n                <tr>\n                    <th>Feature (\u7279\u6027)<\/th>\n                    <th>Festoon Application (\u62d6\u4ee4\u5e94\u7528)<\/th>\n                    <th>Reeling Application (\u5377\u76d8\u5e94\u7528)<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td><strong>Dominant Mechanical Force<\/strong><br>\u4e3b\u5bfc\u673a\u68b0\u529b<\/td>\n                    <td>Continuous Bending<br><span class=\"cn-content\">\u8fde\u7eed\u5f2f\u66f2<\/span><\/td>\n                    <td>High Tension &#038; Torsion<br><span class=\"cn-content\">\u9ad8\u5f20\u529b &#038; \u626d\u8f6c<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Cable Shape Preference<\/strong><br>\u7535\u7f06\u5f62\u72b6\u504f\u597d<\/td>\n                    <td><strong>FLAT<\/strong> (Preferred for stacking stability)<br><span class=\"cn-content\"><strong>\u6241\u5e73<\/strong>\uff08\u9996\u9009\uff0c\u4e3a\u4e86\u5806\u53e0\u7a33\u5b9a\u6027\uff09<\/span><\/td>\n                    <td><strong>ROUND<\/strong> (Mandatory for uniform winding)<br><span class=\"cn-content\"><strong>\u5706\u5f62<\/strong>\uff08\u5f3a\u5236\uff0c\u4e3a\u4e86\u5747\u5300\u5377\u7ed5\uff09<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Internal Reinforcement<\/strong><br>\u5185\u90e8\u589e\u5f3a<\/td>\n                    <td>Usually none required (Copper carries current only).<br><span class=\"cn-content\">\u901a\u5e38\u4e0d\u9700\u8981\uff08\u94dc\u4ec5\u627f\u8f7d\u7535\u6d41\uff09\u3002<\/span><\/td>\n                    <td><strong>Anti-Torsion Braid<\/strong> (Crucial).<br><span class=\"cn-content\"><strong>\u6297\u626d\u8f6c\u7f16\u7ec7\u5c42<\/strong>\uff08\u81f3\u5173\u91cd\u8981\uff09\u3002<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Heat Dissipation<\/strong><br>\u6563\u70ed<\/td>\n                    <td><strong>Good.<\/strong> Flat cables have high surface area.<br><span class=\"cn-content\"><strong>\u597d\u3002<\/strong> \u6241\u5e73\u7535\u7f06\u8868\u9762\u79ef\u5927\u3002<\/span><\/td>\n                    <td><strong>Poor.<\/strong> Multi-layer winding traps heat (De-rating required).<br><span class=\"cn-content\"><strong>\u5dee\u3002<\/strong> \u591a\u5c42\u5377\u7ed5\u4f1a\u805a\u96c6\u70ed\u91cf\uff08\u9700\u8981\u964d\u5bb9\uff09\u3002<\/span><\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Typical Speed<\/strong><br>\u5178\u578b\u901f\u5ea6<\/td>\n                    <td>Up to 240 m\/min (High Speed Trolleys)<br><span class=\"cn-content\">\u9ad8\u8fbe 240 m\/min<\/span><\/td>\n                    <td>Up to 120 m\/min (Motorized Reels)<br><span class=\"cn-content\">\u9ad8\u8fbe 120 m\/min<\/span><\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n    <\/section>\n\n    <section>\n        <h2>5. Engineering Warning: The &#8220;Reeling Factor&#8221;<\/h2>\n        \n        <div class=\"tech-box\">\n            <span class=\"box-label\">Thermal Derating on Drums<\/span>\n            <p>A critical mistake in Reeling applications is ignoring the thermal buildup. When a cable is fully wound on a drum but still energized (current flowing), it acts like an induction coil heater. <strong>VDE 0298-4<\/strong> requires a strict de-rating factor.<\/p>\n            <ul class=\"industrial-list\">\n                <li>1 Layer on Drum: Factor 0.80<\/li>\n                <li>2 Layers on Drum: Factor 0.61<\/li>\n                <li>3 Layers on Drum: Factor 0.49<\/li>\n                <li>4 Layers on Drum: Factor 0.42<\/li>\n            <\/ul>\n            <p><strong>Implication:<\/strong> You often need a much larger cross-section cable for a Reeling Drum than for a Festoon System carrying the same current.<\/p>\n            <p class=\"cn-content\"><strong>\u5377\u76d8\u4e0a\u7684\u70ed\u964d\u5bb9\uff1a<\/strong> \u5377\u76d8\u5e94\u7528\u4e2d\u7684\u4e00\u4e2a\u4e25\u91cd\u9519\u8bef\u662f\u5ffd\u89c6\u70ed\u91cf\u79ef\u805a\u3002\u5f53\u7535\u7f06\u5b8c\u5168\u7f20\u7ed5\u5728\u5377\u7b52\u4e0a\u4f46\u4ecd\u7136\u901a\u7535\uff08\u7535\u6d41\u6d41\u52a8\uff09\u65f6\uff0c\u5b83\u7684\u4f5c\u7528\u5c31\u50cf\u611f\u5e94\u7ebf\u5708\u52a0\u70ed\u5668\u3002<strong>VDE 0298-4<\/strong> \u8981\u6c42\u4e25\u683c\u7684\u964d\u5bb9\u7cfb\u6570\u3002<br><strong>\u542b\u4e49\uff1a<\/strong> \u5bf9\u4e8e\u627f\u8f7d\u76f8\u540c\u7535\u6d41\u7684\u5377\u76d8\u5377\u7b52\uff0c\u60a8\u901a\u5e38\u9700\u8981\u6bd4\u62d6\u4ee4\u7cfb\u7edf\u4f7f\u7528\u622a\u9762\u79ef\u5927\u5f97\u591a\u7684\u7535\u7f06\u3002<\/p>\n        <\/div>\n    <\/section>\n\n    <div class=\"contact-block\">\n        <h3>Contact Anhui Feichun Special Cable Co., Ltd.<\/h3>\n        <p><strong>System Design Consultation: Festoon &#038; Reeling Solutions<\/strong><\/p>\n        \n        <div class=\"contact-details\">\n            <div class=\"contact-row\">\n                <strong>Technical Engineering Dept.<\/strong>\n                <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">tech@feichuncables.com<\/a>\n            <\/div>\n            <div class=\"contact-row\">\n                <strong>International Sales (Zihao Yang)<\/strong>\n                <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow\">zihao.yang@feichuncables.com<\/a>\n            <\/div>\n            <div class=\"contact-row\">\n                <strong>International Sales (Ziyu Huang)<\/strong>\n                <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">ziyu.huang@feichuncables.com<\/a>\n            <\/div>\n            <div class=\"contact-row\">\n                <strong>WhatsApp \/ 24h Support<\/strong>\n                <a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 13855123218<\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n\n    <div class=\"references\">\n        <h4>Authoritative References &#038; Standards:<\/h4>\n        <ul>\n            <li><a href=\"#\" rel=\"nofollow\">DIN VDE 0298-3: Application of cables and cords in power installations &#8211; Guide to use.<\/a><\/li>\n            <li><a href=\"#\" rel=\"nofollow\">DIN VDE 0250-813: Cables for mining and industry &#8211; Medium voltage reeling cables.<\/a><\/li>\n            <li><a href=\"#\" rel=\"nofollow\">IEC 60204-1: Safety of machinery &#8211; Electrical equipment of machines &#8211; General requirements.<\/a><\/li>\n        <\/ul>\n    <\/div>\n\n<\/div>\n\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"Festoon vs Reeling cable difference, VDE 0298-3 selection guide, cable trolley system design, motorized cable reel specification, flat cable vs round cable application, Anhui Feichun Special Cable, (N)GRDG\u00d6U festoon cable, (N)TSCGEW\u00d6U reeling cable, tensile load calculation for cranes, anti-torsion braid function, port machinery electrification, overhead crane power supply, cable bending radius calculation, dynamic stress in mining cables, festoon system speed limits, drum reeling thermal derating, heavy duty rubber cable, gantry crane cable management, IEC 60204-1 crane safety, flexible cable mechanical life","protected":false},"author":1,"featured_media":4877,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[94,165,35,464,56],"tags":[32491,32512,31705,32510,2484,32497,32493,32492,32502,32498,32499,32490,32495,32503,32501,152,2954,32500,32508,111,204,32494,32369,32235,32496,32489,32504,32518,32380,32161,32373,32515,32505,32513,32511,32507,32506,32290,32514,32519,32509,32516],"class_list":["post-4876","post","type-post","status-publish","format-standard","has-post-thumbnail","category-din-vde-0250-mining-cable","category-drag-chain-cable","category-festoon-cable","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","category-reeling-cable","tag-ngrdgou-festoon-cable","tag-ngrdgou-","tag-ntscgewou-reeling-cable","tag-ntscgewou-","tag-anhui-feichun-special-cable","tag-anti-torsion-braid-function","tag-cable-bending-radius-calculation","tag-cable-trolley-system-design","tag-drum-reeling-thermal-derating","tag-dynamic-stress-in-mining-cables","tag-festoon-system-speed-limits","tag-festoon-vs-reeling-cable-difference","tag-flat-cable-vs-round-cable-application","tag-flexible-cable-mechanical-life","tag-gantry-crane-cable-management","tag-heavy-duty-mining-cable","tag-heavy-duty-rubber-cable","tag-iec-60204-1-crane-safety","tag-iec-60204-1-","tag-mining-cable","tag-mining-trailing-cable","tag-motorized-cable-reel-specification","tag-overhead-crane-power-supply","tag-port-machinery-electrification","tag-tensile-load-calculation-for-cranes","tag-vde-0298-3-selection-guide","tag-vde-0298-3-","tag-32518","tag-32380","tag-32161","tag-32373","tag-32515","tag-32505","tag-32513","tag-32511","tag-32507","tag-32506","tag-32290","tag-32514","tag-32519","tag-32509","tag-32516","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4876","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=4876"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4876\/revisions"}],"predecessor-version":[{"id":4878,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4876\/revisions\/4878"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/4877"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=4876"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=4876"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=4876"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}