{"id":4821,"date":"2026-01-22T13:33:42","date_gmt":"2026-01-22T05:33:42","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=4821"},"modified":"2026-01-22T13:33:45","modified_gmt":"2026-01-22T05:33:45","slug":"vde-cable-designation-understanding-g-2g-and-3g-insulation-material-codes","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/vde-cable-designation-understanding-g-2g-and-3g-insulation-material-codes\/","title":{"rendered":"VDE Cable Designation: Understanding &#8220;G&#8221;, &#8220;2G&#8221;, and &#8220;3G&#8221; Insulation Material Codes"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>VDE\u7535\u7f06\u6807\u8bc6\uff1a\u7406\u89e3&#8221;G&#8221;\u3001&#8221;2G&#8221;\u548c&#8221;3G&#8221;\u7edd\u7f18\u6750\u6599\u4ee3\u7801<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"5c514c\" data-has-transparency=\"false\" style=\"--dominant-color: #5c514c;\" loading=\"lazy\" decoding=\"async\" width=\"1020\" height=\"628\" sizes=\"auto, (max-width: 1020px) 100vw, 1020px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552-1020x628.avif\" alt=\"\" class=\"wp-image-4822 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552-1020x628.avif 1020w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552-300x185.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552-768x473.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552-400x246.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552-800x492.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552-832x512.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-552.avif 1030w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"Technical guide explaining VDE cable designation codes G, 2G, and 3G for insulation materials including Elastomer, Silicone Rubber (SIR), and EPR (Ethylene Propylene Rubber). Professional cable engineering reference by Anhui Feichun Special Cable Co., Ltd.\">\n    <meta name=\"keywords\" content=\"VDE cable designation, G 2G 3G insulation codes, elastomer cable, silicone rubber cable, EPR cable, DIN VDE 0282, cable insulation materials\">\n    <title>VDE Cable Designation Codes G, 2G, 3G &#8211; Insulation Materials Explained | Anhui Feichun Special Cable<\/title>\n<\/head>\n<body>\n<article>\n    <header>\n        <h1>VDE Cable Designation: Understanding &#8220;G&#8221;, &#8220;2G&#8221;, and &#8220;3G&#8221; Insulation Material Codes<\/h1>\n        <p><strong>VDE\u7535\u7f06\u6807\u8bc6\uff1a\u7406\u89e3&#8221;G&#8221;\u3001&#8221;2G&#8221;\u548c&#8221;3G&#8221;\u7edd\u7f18\u6750\u6599\u4ee3\u7801<\/strong><\/p>\n        <p>Technical Reference by <strong>Anhui Feichun Special Cable Co., Ltd.<\/strong> (\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8)<\/p>\n    <\/header>\n\n    <nav>\n        <h2>Contents \u76ee\u5f55<\/h2>\n        <ul>\n            <li><a href=\"#introduction\">Introduction \u7b80\u4ecb<\/a><\/li>\n            <li><a href=\"#code-definitions\">Code Definitions \u4ee3\u7801\u5b9a\u4e49<\/a><\/li>\n            <li><a href=\"#material-comparison\">Technical Comparison \u6280\u672f\u5bf9\u6bd4<\/a><\/li>\n            <li><a href=\"#applications\">Industrial Applications \u5de5\u4e1a\u5e94\u7528<\/a><\/li>\n            <li><a href=\"#standards\">Related Standards \u76f8\u5173\u6807\u51c6<\/a><\/li>\n            <li><a href=\"#contact\">Contact Information \u8054\u7cfb\u65b9\u5f0f<\/a><\/li>\n        <\/ul>\n    <\/nav>\n\n    <section id=\"introduction\">\n        <h2>Introduction to VDE Cable Designation System<\/h2>\n        <p><strong>VDE\u7535\u7f06\u547d\u540d\u7cfb\u7edf\u7b80\u4ecb<\/strong><\/p>\n        \n        <p>The VDE (Verband der Elektrotechnik) designation system is widely adopted across Europe for identifying cable properties and specifications. According to the DIN VDE 0292 standard, type designation codes provide systematic identification of cable characteristics including conductor material, insulation type, and structural features. (VDE\u547d\u540d\u7cfb\u7edf\u5728\u6b27\u6d32\u5e7f\u6cdb\u91c7\u7528\uff0c\u7528\u4e8e\u6807\u8bc6\u7535\u7f06\u7279\u6027\u548c\u89c4\u683c\u3002\u6839\u636eDIN VDE 0292\u6807\u51c6\uff0c\u578b\u53f7\u4ee3\u7801\u7cfb\u7edf\u6027\u5730\u6807\u8bc6\u7535\u7f06\u7279\u6027\uff0c\u5305\u62ec\u5bfc\u4f53\u6750\u6599\u3001\u7edd\u7f18\u7c7b\u578b\u548c\u7ed3\u6784\u7279\u5f81\u3002)<\/p>\n\n        <p>Within this system, the letter codes in the &#8220;G&#8221; series specifically denote rubber-based and elastomeric insulation materials. These codes appear within cable type designations to indicate the insulation and\/or sheath material composition. (\u5728\u8be5\u7cfb\u7edf\u4e2d\uff0c&#8221;G&#8221;\u7cfb\u5217\u5b57\u6bcd\u4ee3\u7801\u4e13\u95e8\u8868\u793a\u6a61\u80f6\u57fa\u548c\u5f39\u6027\u4f53\u7edd\u7f18\u6750\u6599\u3002\u8fd9\u4e9b\u4ee3\u7801\u51fa\u73b0\u5728\u7535\u7f06\u578b\u53f7\u4e2d\uff0c\u8868\u793a\u7edd\u7f18\u548c\/\u6216\u62a4\u5957\u6750\u6599\u6210\u5206\u3002)<\/p>\n    <\/section>\n\n    <section id=\"code-definitions\">\n        <h2>VDE Insulation Material Code Definitions<\/h2>\n        <p><strong>VDE\u7edd\u7f18\u6750\u6599\u4ee3\u7801\u5b9a\u4e49<\/strong><\/p>\n\n        <table border=\"1\" cellpadding=\"12\" cellspacing=\"0\" width=\"100%\">\n            <caption><strong>Table 1: Primary G-Series Insulation Codes (\u88681\uff1aG\u7cfb\u5217\u4e3b\u8981\u7edd\u7f18\u4ee3\u7801)<\/strong><\/caption>\n            <thead>\n                <tr>\n                    <th width=\"12%\">Code<br>\u4ee3\u7801<\/th>\n                    <th width=\"25%\">Material (English)<\/th>\n                    <th width=\"25%\">\u6750\u6599 (Chinese)<\/th>\n                    <th width=\"38%\">Chemical Designation<br>\u5316\u5b66\u540d\u79f0<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td><strong>G<\/strong><\/td>\n                    <td>Elastomer (General Rubber)<\/td>\n                    <td>\u5f39\u6027\u4f53\uff08\u901a\u7528\u6a61\u80f6\uff09<\/td>\n                    <td>Generic Elastomeric Compound<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>2G<\/strong><\/td>\n                    <td>Silicone Rubber<\/td>\n                    <td>\u7845\u6a61\u80f6<\/td>\n                    <td>SIR (Silicone Rubber) \/ Polyorganosiloxane<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>3G<\/strong><\/td>\n                    <td>Ethylene Propylene Rubber<\/td>\n                    <td>\u4e59\u4e19\u6a61\u80f6<\/td>\n                    <td>EPR \/ EPDM (Ethylene Propylene Diene Monomer)<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n\n        <h3>Extended G-Series Codes (\u6269\u5c55G\u7cfb\u5217\u4ee3\u7801)<\/h3>\n        \n        <table border=\"1\" cellpadding=\"12\" cellspacing=\"0\" width=\"100%\">\n            <caption><strong>Table 2: Complete G-Series Material Reference (\u88682\uff1a\u5b8c\u6574G\u7cfb\u5217\u6750\u6599\u53c2\u8003)<\/strong><\/caption>\n            <thead>\n                <tr>\n                    <th width=\"10%\">Code<\/th>\n                    <th width=\"30%\">Material<\/th>\n                    <th width=\"20%\">Abbreviation<\/th>\n                    <th width=\"40%\">Primary Characteristics<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>G<\/td>\n                    <td>Elastomer<\/td>\n                    <td>\u2014<\/td>\n                    <td>General-purpose rubber compound (\u901a\u7528\u6a61\u80f6\u5316\u5408\u7269)<\/td>\n                <\/tr>\n                <tr>\n                    <td>2G<\/td>\n                    <td>Silicone Rubber<\/td>\n                    <td>SIR<\/td>\n                    <td>High temperature resistance (\u9ad8\u6e29\u8010\u53d7\u6027)<\/td>\n                <\/tr>\n                <tr>\n                    <td>3G<\/td>\n                    <td>Ethylene Propylene Rubber<\/td>\n                    <td>EPR<\/td>\n                    <td>Excellent dielectric properties (\u4f18\u5f02\u4ecb\u7535\u6027\u80fd)<\/td>\n                <\/tr>\n                <tr>\n                    <td>4G<\/td>\n                    <td>Ethylene Vinyl Acetate<\/td>\n                    <td>EVA<\/td>\n                    <td>Flexibility and UV resistance (\u67d4\u97e7\u6027\u548c\u6297\u7d2b\u5916\u7ebf)<\/td>\n                <\/tr>\n                <tr>\n                    <td>5G<\/td>\n                    <td>Polychloroprene (Neoprene)<\/td>\n                    <td>CR<\/td>\n                    <td>Oil and flame resistance (\u8010\u6cb9\u548c\u963b\u71c3)<\/td>\n                <\/tr>\n                <tr>\n                    <td>6G<\/td>\n                    <td>Chlorosulfonated Polyethylene<\/td>\n                    <td>CSM \/ Hypalon<\/td>\n                    <td>Chemical resistance (\u8010\u5316\u5b66\u6027)<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n    <\/section>\n\n    <section id=\"material-comparison\">\n        <h2>Technical Specifications Comparison<\/h2>\n        <p><strong>\u6280\u672f\u89c4\u683c\u5bf9\u6bd4<\/strong><\/p>\n\n        <table border=\"1\" cellpadding=\"12\" cellspacing=\"0\" width=\"100%\">\n            <caption><strong>Table 3: Thermal and Electrical Performance Parameters (\u88683\uff1a\u70ed\u5b66\u548c\u7535\u6c14\u6027\u80fd\u53c2\u6570)<\/strong><\/caption>\n            <thead>\n                <tr>\n                    <th width=\"20%\">Parameter<br>\u53c2\u6570<\/th>\n                    <th width=\"26%\">G &#8211; Elastomer<br>\u5f39\u6027\u4f53<\/th>\n                    <th width=\"27%\">2G &#8211; Silicone (SIR)<br>\u7845\u6a61\u80f6<\/th>\n                    <th width=\"27%\">3G &#8211; EPR<br>\u4e59\u4e19\u6a61\u80f6<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td><strong>Operating Temperature Range<\/strong><br>\u5de5\u4f5c\u6e29\u5ea6\u8303\u56f4<\/td>\n                    <td>-30\u00b0C to +60\u00b0C<\/td>\n                    <td>-60\u00b0C to +180\u00b0C<br>(up to +200\u00b0C special grades)<\/td>\n                    <td>-55\u00b0C to +150\u00b0C<br>(up to +160\u00b0C with peroxide curing)<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Continuous Conductor Temperature<\/strong><br>\u5bfc\u4f53\u6301\u7eed\u6e29\u5ea6<\/td>\n                    <td>60\u00b0C to 90\u00b0C<\/td>\n                    <td>150\u00b0C to 180\u00b0C<\/td>\n                    <td>90\u00b0C (standard)<br>105\u00b0C (high-grade)<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Short-Circuit Temperature<\/strong><br>\u77ed\u8def\u6e29\u5ea6<\/td>\n                    <td>200\u00b0C<\/td>\n                    <td>250\u00b0C<\/td>\n                    <td>250\u00b0C<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Dielectric Strength<\/strong><br>\u4ecb\u7535\u5f3a\u5ea6<\/td>\n                    <td>Standard<\/td>\n                    <td>Excellent<\/td>\n                    <td>High (superior to XLPE)<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Flexibility<\/strong><br>\u67d4\u97e7\u6027<\/td>\n                    <td>Good<\/td>\n                    <td>Excellent<\/td>\n                    <td>Very Good<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Ozone Resistance<\/strong><br>\u8010\u81ed\u6c27\u6027<\/td>\n                    <td>Moderate<\/td>\n                    <td>Excellent<\/td>\n                    <td>Excellent<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Water Treeing Resistance<\/strong><br>\u8010\u6c34\u6811\u6027<\/td>\n                    <td>Moderate<\/td>\n                    <td>Good<\/td>\n                    <td>Low sensitivity<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Halogen Content<\/strong><br>\u5364\u7d20\u542b\u91cf<\/td>\n                    <td>Varies<\/td>\n                    <td>Halogen-free (\u65e0\u5364)<\/td>\n                    <td>Halogen-free (\u65e0\u5364)<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n\n        <h3>Material Properties Detail: 2G Silicone Rubber (2G\u7845\u6a61\u80f6\u6750\u6599\u7279\u6027\u8be6\u89e3)<\/h3>\n        \n        <p>Silicone rubber (polyorganosiloxane) differs fundamentally from carbon-based elastomers due to its silicon-oxygen (Si-O) molecular backbone. The Si-O bond exhibits high bond energy, providing exceptional thermal stability. Key characteristics include stable dielectric constant and loss factor at temperatures up to 250\u00b0C, excellent corona and arc resistance, and retained flexibility across extreme temperature ranges. (\u7845\u6a61\u80f6\u56e0\u5176\u7845-\u6c27\u5206\u5b50\u9aa8\u67b6\u800c\u4e0e\u78b3\u57fa\u5f39\u6027\u4f53\u6839\u672c\u4e0d\u540c\u3002Si-O\u952e\u5177\u6709\u9ad8\u952e\u80fd\uff0c\u63d0\u4f9b\u5353\u8d8a\u7684\u70ed\u7a33\u5b9a\u6027\u3002\u5173\u952e\u7279\u6027\u5305\u62ec\uff1a\u5728250\u00b0C\u9ad8\u6e29\u4e0b\u7a33\u5b9a\u7684\u4ecb\u7535\u5e38\u6570\u548c\u635f\u8017\u56e0\u5b50\u3001\u4f18\u5f02\u7684\u8010\u7535\u6655\u548c\u7535\u5f27\u6027\u80fd\uff0c\u4ee5\u53ca\u5728\u6781\u7aef\u6e29\u5ea6\u8303\u56f4\u5185\u4fdd\u6301\u7684\u67d4\u97e7\u6027\u3002)<\/p>\n\n        <h3>Material Properties Detail: 3G EPR \/ EPDM (3G\u4e59\u4e19\u6a61\u80f6\u6750\u6599\u7279\u6027\u8be6\u89e3)<\/h3>\n        \n        <p>EPR (Ethylene Propylene Rubber) represents a family of copolymers and terpolymers of ethylene and propylene. EPDM (Ethylene Propylene Diene Monomer) incorporates diene monomers for enhanced cross-linking capabilities. EPR insulation demonstrates superior dielectric properties compared to traditional materials, enabling higher voltage applications with reduced cross-sectional requirements. The saturated polymer backbone provides inherent resistance to oxidation, ozone degradation, and weathering without requiring additional stabilizers. (EPR\u4ee3\u8868\u4e59\u70ef\u548c\u4e19\u70ef\u7684\u5171\u805a\u7269\u548c\u4e09\u5143\u5171\u805a\u7269\u5bb6\u65cf\u3002EPDM\u5f15\u5165\u4e8c\u70ef\u5355\u4f53\u4ee5\u589e\u5f3a\u4ea4\u8054\u80fd\u529b\u3002EPR\u7edd\u7f18\u8868\u73b0\u51fa\u4f18\u4e8e\u4f20\u7edf\u6750\u6599\u7684\u4ecb\u7535\u6027\u80fd\uff0c\u4f7f\u66f4\u9ad8\u7535\u538b\u5e94\u7528\u80fd\u591f\u51cf\u5c11\u622a\u9762\u8981\u6c42\u3002\u9971\u548c\u805a\u5408\u7269\u9aa8\u67b6\u63d0\u4f9b\u56fa\u6709\u7684\u6297\u6c27\u5316\u3001\u8010\u81ed\u6c27\u964d\u89e3\u548c\u8010\u5019\u6027\uff0c\u65e0\u9700\u989d\u5916\u7a33\u5b9a\u5242\u3002)<\/p>\n    <\/section>\n\n    <section id=\"applications\">\n        <h2>Industrial Applications by Insulation Type<\/h2>\n        <p><strong>\u6309\u7edd\u7f18\u7c7b\u578b\u5212\u5206\u7684\u5de5\u4e1a\u5e94\u7528<\/strong><\/p>\n\n        <table border=\"1\" cellpadding=\"12\" cellspacing=\"0\" width=\"100%\">\n            <caption><strong>Table 4: Application Matrix (\u88684\uff1a\u5e94\u7528\u77e9\u9635)<\/strong><\/caption>\n            <thead>\n                <tr>\n                    <th width=\"15%\">Code<\/th>\n                    <th width=\"42%\">Typical Applications<\/th>\n                    <th width=\"43%\">\u5178\u578b\u5e94\u7528<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td><strong>G<\/strong><\/td>\n                    <td>General industrial equipment, appliances, portable tools, household electronics<\/td>\n                    <td>\u901a\u7528\u5de5\u4e1a\u8bbe\u5907\u3001\u7535\u5668\u3001\u4fbf\u643a\u5f0f\u5de5\u5177\u3001\u5bb6\u7528\u7535\u5b50\u4ea7\u54c1<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>2G (SIR)<\/strong><\/td>\n                    <td>Steel mills, smelting operations, power plants, coking facilities, metallurgical machinery, petroleum refineries, chemical processing, high-temperature lighting systems, aerospace applications, railway rolling stock, medical equipment<\/td>\n                    <td>\u94a2\u94c1\u5382\u3001\u51b6\u70bc\u4f5c\u4e1a\u3001\u53d1\u7535\u5382\u3001\u7126\u5316\u8bbe\u65bd\u3001\u51b6\u91d1\u673a\u68b0\u3001\u77f3\u6cb9\u70bc\u5382\u3001\u5316\u5de5\u5904\u7406\u3001\u9ad8\u6e29\u7167\u660e\u7cfb\u7edf\u3001\u822a\u7a7a\u822a\u5929\u5e94\u7528\u3001\u94c1\u8def\u673a\u8f66\u8f66\u8f86\u3001\u533b\u7597\u8bbe\u5907<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>3G (EPR)<\/strong><\/td>\n                    <td>High-voltage power distribution, medium-voltage cables, mining equipment, trailing cables, dredge operations, offshore installations, marine applications, mobile power supplies, cranes, hoisting equipment, renewable energy installations<\/td>\n                    <td>\u9ad8\u538b\u914d\u7535\u3001\u4e2d\u538b\u7535\u7f06\u3001\u91c7\u77ff\u8bbe\u5907\u3001\u62d6\u66f3\u7535\u7f06\u3001\u758f\u6d5a\u4f5c\u4e1a\u3001\u6d77\u4e0a\u8bbe\u65bd\u3001\u8239\u8236\u5e94\u7528\u3001\u79fb\u52a8\u7535\u6e90\u3001\u8d77\u91cd\u673a\u3001\u8d77\u91cd\u8bbe\u5907\u3001\u53ef\u518d\u751f\u80fd\u6e90\u8bbe\u65bd<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n\n        <h3>Cable Type Examples (\u7535\u7f06\u578b\u53f7\u793a\u4f8b)<\/h3>\n        \n        <table border=\"1\" cellpadding=\"12\" cellspacing=\"0\" width=\"100%\">\n            <caption><strong>Table 5: Common VDE Cable Designations Using G-Codes (\u88685\uff1a\u4f7f\u7528G\u4ee3\u7801\u7684\u5e38\u89c1VDE\u7535\u7f06\u578b\u53f7)<\/strong><\/caption>\n            <thead>\n                <tr>\n                    <th width=\"25%\">Designation<br>\u578b\u53f7<\/th>\n                    <th width=\"20%\">Insulation Code<\/th>\n                    <th width=\"55%\">Description \/ \u63cf\u8ff0<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>NSSH\u00d6U<\/td>\n                    <td>G (Elastomer)<\/td>\n                    <td>Heavy-duty rubber-sheathed flexible cable (\u91cd\u578b\u6a61\u80f6\u62a4\u5957\u67d4\u6027\u7535\u7f06)<\/td>\n                <\/tr>\n                <tr>\n                    <td>SIF \/ SIAF<\/td>\n                    <td>2G (Silicone)<\/td>\n                    <td>High-temperature silicone insulated equipment wire (\u9ad8\u6e29\u7845\u80f6\u7edd\u7f18\u8bbe\u5907\u7ebf)<\/td>\n                <\/tr>\n                <tr>\n                    <td>H05S-K \/ H05SJ-K<\/td>\n                    <td>2G (Silicone)<\/td>\n                    <td>Silicone rubber insulated flexible cable per DIN VDE 0282 (\u7b26\u5408DIN VDE 0282\u7684\u7845\u6a61\u80f6\u7edd\u7f18\u67d4\u6027\u7535\u7f06)<\/td>\n                <\/tr>\n                <tr>\n                    <td>N2XSY<\/td>\n                    <td>3G (EPR variant)<\/td>\n                    <td>Medium voltage power cable with EPR insulation (\u4e2d\u538bEPR\u7edd\u7f18\u7535\u529b\u7535\u7f06)<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n    <\/section>\n\n    <section id=\"standards\">\n        <h2>Applicable Standards and Regulations<\/h2>\n        <p><strong>\u9002\u7528\u6807\u51c6\u548c\u6cd5\u89c4<\/strong><\/p>\n\n        <table border=\"1\" cellpadding=\"12\" cellspacing=\"0\" width=\"100%\">\n            <caption><strong>Table 6: Relevant Technical Standards (\u88686\uff1a\u76f8\u5173\u6280\u672f\u6807\u51c6)<\/strong><\/caption>\n            <thead>\n                <tr>\n                    <th width=\"30%\">Standard<br>\u6807\u51c6<\/th>\n                    <th width=\"70%\">Scope \/ \u8303\u56f4<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>DIN VDE 0282<\/td>\n                    <td>Cables of rated voltages up to 450\/750 V with cross-linked insulation (\u989d\u5b9a\u7535\u538b\u81f3450\/750 V\u7684\u4ea4\u8054\u7edd\u7f18\u7535\u7f06)<\/td>\n                <\/tr>\n                <tr>\n                    <td>DIN VDE 0292<\/td>\n                    <td>Type designation codes for cable identification (\u7535\u7f06\u6807\u8bc6\u578b\u53f7\u4ee3\u7801)<\/td>\n                <\/tr>\n                <tr>\n                    <td>DIN VDE 0293-308<\/td>\n                    <td>Core identification by colors (\u82af\u7ebf\u989c\u8272\u6807\u8bc6)<\/td>\n                <\/tr>\n                <tr>\n                    <td>HD 22 (CENELEC)<\/td>\n                    <td>Harmonized document for rubber-insulated cables (\u6a61\u80f6\u7edd\u7f18\u7535\u7f06\u534f\u8c03\u6587\u4ef6)<\/td>\n                <\/tr>\n                <tr>\n                    <td>IEC 60228<\/td>\n                    <td>Conductors of insulated cables (\u7edd\u7f18\u7535\u7f06\u5bfc\u4f53)<\/td>\n                <\/tr>\n                <tr>\n                    <td>EN 50525<\/td>\n                    <td>Electric cables &#8211; Low voltage energy cables (\u7535\u7f06 &#8211; \u4f4e\u538b\u80fd\u6e90\u7535\u7f06)<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n\n        <h3>Reference Sources (\u53c2\u8003\u6765\u6e90)<\/h3>\n        <p>This technical article references the following authoritative sources for accuracy verification:<\/p>\n        <ul>\n            <li><a href=\"https:\/\/www.helukabel.com\/media\/publication\/de\/cor_docs\/qt_23\/QT_COR-DOCS_X_014_Code-designation-explanations_for_cables_and_insulated.pdf\" rel=\"nofollow noopener\" target=\"_blank\">HELUKABEL &#8211; Code Designation Explanations for Cables<\/a><\/li>\n            <li><a href=\"https:\/\/media.faberkabel.de\/technical-data.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Faber Kabel &#8211; Type Designation Code Technical Data<\/a><\/li>\n            <li><a href=\"https:\/\/www.elandcables.com\/the-cable-lab\/faqs\/faq-what-are-the-benefits-of-epr-insulated-cables\" rel=\"nofollow noopener\" target=\"_blank\">Eland Cables &#8211; EPR Insulated Cable Benefits<\/a><\/li>\n            <li><a href=\"https:\/\/www.elandcables.com\/the-cable-lab\/faqs\/faq-what-are-the-benefits-of-silicone-insulated-cables\" rel=\"nofollow noopener\" target=\"_blank\">Eland Cables &#8211; Silicone Insulated Cable Benefits<\/a><\/li>\n            <li><a href=\"https:\/\/tratosgroup.com\/tratos-cable-academy\/polymeric-materials-for-cables-insulation-and-sheath\/epr-epdm-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">Tratos Cable Academy &#8211; EPR\/EPDM Cables<\/a><\/li>\n            <li><a href=\"https:\/\/tratosgroup.com\/tratos-cable-academy\/polymeric-materials-for-cables-insulation\/general-purpose-silicone-rubber-cables\/\" rel=\"nofollow noopener\" target=\"_blank\">Tratos Cable Academy &#8211; Silicone Rubber Cables<\/a><\/li>\n            <li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Ethylene_propylene_rubber\" rel=\"nofollow noopener\" target=\"_blank\">Wikipedia &#8211; Ethylene Propylene Rubber<\/a><\/li>\n            <li><a href=\"https:\/\/www.bayka.de\/en\/service\/technical-information\/type-designation-codes\/\" rel=\"nofollow noopener\" target=\"_blank\">Bayerische Kabelwerke &#8211; Type Designation Codes<\/a><\/li>\n            <li><a href=\"https:\/\/www.vde-verlag.de\/standards\/0282046\/din-vde-0282-15-vde-0282-15-2000-05.html\" rel=\"nofollow noopener\" target=\"_blank\">VDE Publishing House &#8211; DIN VDE 0282-15<\/a><\/li>\n        <\/ul>\n    <\/section>\n\n    <section id=\"contact\">\n        <h2>Contact Anhui Feichun Special Cable Co., Ltd.<\/h2>\n        <p><strong>\u8054\u7cfb\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/strong><\/p>\n\n        <table border=\"1\" cellpadding=\"12\" cellspacing=\"0\" width=\"100%\">\n            <tbody>\n                <tr>\n                    <td width=\"30%\"><strong>Company Name<\/strong><br>\u516c\u53f8\u540d\u79f0<\/td>\n                    <td width=\"70%\">Anhui Feichun Special Cable Co., Ltd.<br>\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Technical Support<\/strong><br>\u6280\u672f\u652f\u6301<\/td>\n                    <td><a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow noopener\">tech@feichuncables.com<\/a><\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>Sales Inquiry<\/strong><br>\u9500\u552e\u54a8\u8be2<\/td>\n                    <td>\n                        <a href=\"mailto:zihao.yang@feichuncables.com\" rel=\"nofollow noopener\">zihao.yang@feichuncables.com<\/a><br>\n                        <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow noopener\">ziyu.huang@feichuncables.com<\/a>\n                    <\/td>\n                <\/tr>\n                <tr>\n                    <td><strong>WhatsApp<\/strong><br>WhatsApp\u8054\u7cfb<\/td>\n                    <td><a href=\"https:\/\/wa.me\/8613855123218\" rel=\"nofollow noopener\" target=\"_blank\">+86 138 5512 3218<\/a><\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n\n        <p>For custom cable solutions utilizing G, 2G (Silicone), or 3G (EPR) insulation materials, our engineering team provides comprehensive technical consultation and product specifications tailored to your industrial requirements. (\u5982\u9700\u4f7f\u7528G\u30012G\uff08\u7845\u6a61\u80f6\uff09\u62163G\uff08EPR\uff09\u7edd\u7f18\u6750\u6599\u7684\u5b9a\u5236\u7535\u7f06\u89e3\u51b3\u65b9\u6848\uff0c\u6211\u4eec\u7684\u5de5\u7a0b\u56e2\u961f\u5c06\u6839\u636e\u60a8\u7684\u5de5\u4e1a\u9700\u6c42\u63d0\u4f9b\u5168\u9762\u7684\u6280\u672f\u54a8\u8be2\u548c\u4ea7\u54c1\u89c4\u683c\u3002)<\/p>\n    <\/section>\n\n    <footer>\n        <hr>\n        <p><small>\u00a9 2025 Anhui Feichun Special Cable Co., Ltd. (\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8) &#8211; Technical Reference Document<\/small><\/p>\n        <p><small>Last Updated: January 2025 | Document for reference purposes. Specifications subject to verification with current standards.<\/small><\/p>\n    <\/footer>\n<\/article>\n<\/body>\n<\/html>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"The VDE (Verband der Elektrotechnik) designation system is widely adopted across Europe for identifying cable properties and specifications. According to the DIN VDE 0292 standard, type designation codes provide systematic identification of cable characteristics including conductor material, insulation type, and structural features. (VDE\u547d\u540d\u7cfb\u7edf\u5728\u6b27\u6d32\u5e7f\u6cdb\u91c7\u7528\uff0c\u7528\u4e8e\u6807\u8bc6\u7535\u7f06\u7279\u6027\u548c\u89c4\u683c\u3002\u6839\u636eDIN VDE 0292\u6807\u51c6\uff0c\u578b\u53f7\u4ee3\u7801\u7cfb\u7edf\u6027\u5730\u6807\u8bc6\u7535\u7f06\u7279\u6027\uff0c\u5305\u62ec\u5bfc\u4f53\u6750\u6599\u3001\u7edd\u7f18\u7c7b\u578b\u548c\u7ed3\u6784\u7279\u5f81\u3002)","protected":false},"author":1,"featured_media":4822,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[94,56],"tags":[31979,31977,31982,31975,1267,31968,1249,10873,5199,5075,31984,24456,31945,31992,31967,978,4214,31989,1723,10990,3005,31987,10955,18610,31962,830,31971,18228,1030,31988,31978,31985,3167,1044,19089,31972,31974,31973,111,31966,31964,6484,1028,788,1233,25033,1084,31993,31965,31963,31994,31991,31990,4216,31976,31969,31983,31986,23461,31961,31960,31970,31980,31981],"class_list":["post-4821","post","type-post","status-publish","format-standard","has-post-thumbnail","category-din-vde-0250-mining-cable","category-reeling-cable","tag-150c-conductor-temperature","tag-180c-rated-cable","tag-3g-epr-cable-designation-explained","tag-aerospace-wire","tag-ce-marked-cable","tag-cenelec-hd-22","tag-chemical-plant-cable","tag-cross-linked-insulation","tag-custom-cable-solutions","tag-dielectric-strength-cable","tag-difference-between-2g-and-3g-cable-insulation","tag-din-vde-0282","tag-din-vde-0292","tag-din-vde-cable-identification-guide","tag-din-vde-standard-cable","tag-en-50525-cable","tag-epr-cable-supplier","tag-epr-cable-temperature-rating","tag-european-cable-standards","tag-flame-retardant-rubber-cable","tag-flexible-rubber-cable","tag-german-cable-naming-system","tag-german-cable-standard","tag-h05s-k-silicone-cable","tag-h05sj-k-cable","tag-halogen-free-cable","tag-harmonized-cable-codes","tag-heat-resistant-wire","tag-high-temperature-cable","tag-high-temperature-cable-for-steel-mill","tag-high-voltage-insulation-material","tag-how-to-read-vde-cable-markings","tag-iec-60228-conductor","tag-industrial-cable","tag-industrial-cable-supplier","tag-marine-cable-insulation","tag-medical-equipment-wire","tag-metallurgical-equipment-cable","tag-mining-cable","tag-n2xsy-epr-cable","tag-nsshou-rubber-cable","tag-oem-cable-production","tag-offshore-cable","tag-ozone-resistant-cable","tag-power-plant-cable","tag-railway-rolling-stock-cable","tag-renewable-energy-cable","tag-rubber-insulated-cable-wholesale","tag-siaf-high-temperature-wire","tag-sif-silicone-wire","tag-silicone-cable-manufacturer-china","tag-silicone-rubber-cable-operating-temperature","tag-silicone-vs-epr-cable-insulation","tag-special-cable-manufacturer","tag-steel-mill-wiring","tag-vde-0282-15","tag-vde-2g-silicone-rubber-meaning","tag-vde-cable-code-chart","tag-vde-cable-designation","tag-vde-g-2g-3g-codes","tag-vde-insulation-codes","tag-vde-type-designation","tag-water-treeing-resistant","tag-what-does-g-mean-in-vde-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4821","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=4821"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4821\/revisions"}],"predecessor-version":[{"id":4823,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4821\/revisions\/4823"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/4822"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=4821"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=4821"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=4821"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}