{"id":4016,"date":"2026-01-04T09:47:58","date_gmt":"2026-01-04T01:47:58","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=4016"},"modified":"2026-01-04T09:50:42","modified_gmt":"2026-01-04T01:50:42","slug":"what-is-iec-60092-cable","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/what-is-iec-60092-cable\/","title":{"rendered":"What is IEC 60092 Cable?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Complete Technical Guide to Marine &amp; Offshore Cable Standard \u2014 Shipboard Electrical Installations, BS 6883, NEK 606, Power &amp; Instrumentation Cables<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"e3e3e3\" data-has-transparency=\"false\" style=\"--dominant-color: #e3e3e3;\" loading=\"lazy\" decoding=\"async\" width=\"776\" height=\"628\" sizes=\"auto, (max-width: 776px) 100vw, 776px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-441-776x628.avif\" alt=\"\" class=\"wp-image-4017 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-441-776x628.avif 776w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-441-300x243.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-441-768x622.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-441-400x324.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-441-800x648.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-441.avif 819w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"Complete technical guide to IEC 60092 marine cable standard - shipboard and offshore electrical installations, BS 6883, NEK 606, power and instrumentation cables for ships and offshore platforms.\">\n    <meta name=\"keywords\" content=\"IEC 60092, marine cable, shipboard cable, offshore cable, BS 6883, NEK 606, BFOU, RFOU, 657TQ, 658TQ, ship wiring, offshore platform cable\">\n    <meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n    <title>What is IEC 60092 Cable? Marine &#038; Offshore Cable Standard Guide | Feichun Cable<\/title>\n    <style>\n        :root {\n            --bg-primary: #0a0e14;\n            --bg-secondary: #131920;\n            --bg-tertiary: #1a2028;\n            --text-primary: #e6edf3;\n            --text-secondary: #8b949e;\n            --text-muted: #6e7681;\n            --accent-cyan: #06b6d4;\n            --accent-green: #10b981;\n            --accent-orange: #f59e0b;\n            --accent-red: #ef4444;\n            --accent-gold: #d4af37;\n            --accent-purple: #8b5cf6;\n            --accent-blue: #3b82f6;\n            --border-color: #30363d;\n            --link-color: #58a6ff;\n            --highlight-bg: #388bfd26;\n            --marine-blue: #003366;\n            --marine-cyan: #00668c;\n            --offshore-orange: #e65c00;\n        }\n        \n        * { margin: 0; padding: 0; box-sizing: border-box; }\n        \n        body {\n            font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', 'Noto Sans', Helvetica, Arial, sans-serif;\n            background-color: var(--bg-primary);\n            color: var(--text-primary);\n            line-height: 1.7;\n            font-size: 16px;\n        }\n        \n        .container { max-width: 1200px; margin: 0 auto; padding: 0 24px; }\n        \n        header {\n            background: linear-gradient(135deg, #003366 0%, #00668c 50%, #0088aa 100%);\n            padding: 60px 0;\n            border-bottom: 4px solid var(--accent-gold);\n        }\n        \n        .header-content { text-align: center; }\n        \n        .company-name {\n            font-size: 1rem;\n            color: rgba(255,255,255,0.9);\n            margin-bottom: 16px;\n            letter-spacing: 2px;\n            text-transform: uppercase;\n        }\n        \n        .company-name-cn {\n            font-size: 0.9rem;\n            color: rgba(255,255,255,0.7);\n            margin-bottom: 24px;\n        }\n        \n        h1 {\n            font-size: 2.5rem;\n            font-weight: 700;\n            margin-bottom: 16px;\n            color: #ffffff;\n            text-shadow: 2px 2px 4px rgba(0,0,0,0.3);\n        }\n        \n        .subtitle {\n            font-size: 1.2rem;\n            color: rgba(255,255,255,0.85);\n            max-width: 900px;\n            margin: 0 auto;\n        }\n        \n        .certification-badges {\n            display: flex;\n            justify-content: center;\n            gap: 12px;\n            margin-top: 24px;\n            flex-wrap: wrap;\n        }\n        \n        .cert-badge {\n            background: rgba(255,255,255,0.15);\n            padding: 8px 16px;\n            border-radius: 20px;\n            font-size: 0.85rem;\n            color: #ffffff;\n            border: 1px solid rgba(255,255,255,0.3);\n        }\n        \n        main { padding: 48px 0; }\n        section { margin-bottom: 48px; }\n        \n        h2 {\n            font-size: 1.75rem;\n            color: var(--marine-cyan);\n            margin-bottom: 24px;\n            padding-bottom: 12px;\n            border-bottom: 2px solid var(--border-color);\n        }\n        \n        h3 { font-size: 1.35rem; color: var(--text-primary); margin: 32px 0 16px 0; }\n        h4 { font-size: 1.1rem; color: var(--accent-cyan); margin: 24px 0 12px 0; }\n        p { margin-bottom: 16px; color: var(--text-secondary); }\n        \n        .lang-badge {\n            display: inline-block;\n            padding: 4px 12px;\n            border-radius: 12px;\n            font-size: 0.75rem;\n            font-weight: 600;\n            margin-right: 8px;\n            text-transform: uppercase;\n        }\n        \n        .lang-es { background: linear-gradient(135deg, #f59e0b, #d97706); color: #fff; }\n        .lang-zh { background: linear-gradient(135deg, #10b981, #059669); color: #fff; }\n        \n        .lang-section {\n            background: var(--bg-secondary);\n            border-radius: 8px;\n            padding: 24px;\n            margin: 24px 0;\n            border-left: 4px solid;\n        }\n        \n        .lang-section.spanish { border-left-color: var(--accent-orange); }\n        .lang-section.chinese { border-left-color: var(--accent-green); }\n        \n        .spec-table {\n            width: 100%;\n            border-collapse: collapse;\n            margin: 24px 0;\n            font-size: 0.8rem;\n        }\n        \n        .spec-table th, .spec-table td {\n            padding: 8px 10px;\n            text-align: left;\n            border: 1px solid var(--border-color);\n        }\n        \n        .spec-table th {\n            background: var(--bg-tertiary);\n            color: var(--marine-cyan);\n            font-weight: 600;\n        }\n        \n        .spec-table td {\n            background: var(--bg-secondary);\n            color: var(--text-secondary);\n        }\n        \n        .spec-table tr:hover td { background: var(--highlight-bg); }\n        \n        .spec-table .header-iec { background: linear-gradient(90deg, rgba(0,102,140,0.3), var(--bg-secondary)); color: var(--marine-cyan); font-weight: 600; }\n        .spec-table .header-bs { background: linear-gradient(90deg, rgba(139,92,246,0.3), var(--bg-secondary)); color: var(--accent-purple); font-weight: 600; }\n        .spec-table .header-nek { background: linear-gradient(90deg, rgba(230,92,0,0.3), var(--bg-secondary)); color: var(--offshore-orange); font-weight: 600; }\n        .spec-table .header-power { background: linear-gradient(90deg, rgba(59,130,246,0.3), var(--bg-secondary)); color: var(--accent-blue); font-weight: 600; }\n        .spec-table .header-inst { background: linear-gradient(90deg, rgba(16,185,129,0.3), var(--bg-secondary)); color: var(--accent-green); font-weight: 600; }\n        \n        .highlight-box {\n            background: linear-gradient(135deg, var(--bg-secondary), var(--bg-tertiary));\n            border: 1px solid var(--border-color);\n            border-radius: 8px;\n            padding: 24px;\n            margin: 24px 0;\n        }\n        \n        .highlight-box.marine { border-left: 4px solid var(--marine-cyan); background: linear-gradient(135deg, rgba(0,102,140,0.1), var(--bg-secondary)); }\n        .highlight-box.fire { border-left: 4px solid var(--accent-red); background: linear-gradient(135deg, rgba(239,68,68,0.1), var(--bg-secondary)); }\n        .highlight-box.offshore { border-left: 4px solid var(--offshore-orange); background: linear-gradient(135deg, rgba(230,92,0,0.1), var(--bg-secondary)); }\n        \n        .highlight-title { color: var(--text-primary); font-weight: 600; font-size: 1.1rem; margin-bottom: 12px; }\n        \n        .parameter-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(160px, 1fr));\n            gap: 16px;\n            margin: 24px 0;\n        }\n        \n        .parameter-card {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            border-radius: 8px;\n            padding: 16px;\n        }\n        \n        .parameter-card h4 { color: var(--marine-cyan); margin: 0 0 10px 0; font-size: 0.85rem; }\n        .parameter-value { font-size: 1.2rem; font-weight: 700; color: var(--text-primary); margin-bottom: 4px; }\n        .parameter-unit { font-size: 0.75rem; color: var(--text-muted); }\n        \n        .cable-badge {\n            display: inline-block;\n            padding: 3px 8px;\n            border-radius: 4px;\n            font-size: 0.7rem;\n            font-weight: 700;\n            margin: 1px;\n        }\n        \n        .badge-bfou { background: linear-gradient(135deg, #dc2626, #ef4444); color: #fff; }\n        .badge-rfou { background: linear-gradient(135deg, #ea580c, #f97316); color: #fff; }\n        .badge-bs { background: linear-gradient(135deg, #7c3aed, #8b5cf6); color: #fff; }\n        .badge-iec { background: linear-gradient(135deg, #0066cc, #3b82f6); color: #fff; }\n        .badge-xi { background: linear-gradient(135deg, #059669, #10b981); color: #fff; }\n        \n        .standard-badge {\n            display: inline-block;\n            padding: 3px 8px;\n            border-radius: 4px;\n            font-size: 0.7rem;\n            font-weight: 600;\n            margin: 1px;\n        }\n        \n        .std-iec { background: rgba(0,102,140,0.3); color: #00a8cc; border: 1px solid #00a8cc; }\n        .std-bs { background: rgba(139,92,246,0.2); color: #a78bfa; border: 1px solid #a78bfa; }\n        .std-nek { background: rgba(230,92,0,0.2); color: #fb923c; border: 1px solid #fb923c; }\n        .std-dnv { background: rgba(16,185,129,0.2); color: #4ade80; border: 1px solid #4ade80; }\n        .std-lr { background: rgba(239,68,68,0.2); color: #f87171; border: 1px solid #f87171; }\n        \n        .fire-badge {\n            display: inline-block;\n            padding: 2px 6px;\n            border-radius: 3px;\n            font-size: 0.65rem;\n            font-weight: 600;\n        }\n        \n        .fire-resistant { background: #dc2626; color: #fff; }\n        .flame-retardant { background: #ea580c; color: #fff; }\n        \n        .citation { font-size: 0.85rem; color: var(--text-muted); font-style: italic; margin-top: 12px; }\n        .source-ref { color: var(--link-color); text-decoration: none; }\n        .source-ref:hover { text-decoration: underline; }\n        \n        .external-sources {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            border-radius: 8px;\n            padding: 24px;\n            margin: 32px 0;\n        }\n        \n        .external-sources h3 { color: var(--marine-cyan); margin-bottom: 16px; }\n        .source-list { display: grid; gap: 12px; }\n        \n        .source-item {\n            display: flex;\n            align-items: flex-start;\n            gap: 12px;\n            padding: 12px;\n            background: var(--bg-tertiary);\n            border-radius: 6px;\n        }\n        \n        .source-icon { color: var(--marine-cyan); font-size: 0.8rem; margin-top: 4px; }\n        \n        .marine-box {\n            background: linear-gradient(135deg, var(--bg-tertiary), var(--bg-secondary));\n            border: 3px solid var(--marine-cyan);\n            border-radius: 12px;\n            padding: 24px;\n            margin: 32px 0;\n        }\n        \n        .marine-box h3 { color: var(--marine-cyan); margin-bottom: 16px; text-align: center; }\n        \n        .contact-section {\n            background: linear-gradient(135deg, #0a0e14, #131920);\n            border: 2px solid var(--marine-cyan);\n            border-radius: 12px;\n            padding: 32px;\n            margin: 48px 0;\n        }\n        \n        .contact-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n            gap: 24px;\n            margin-top: 24px;\n        }\n        \n        .contact-item {\n            display: flex;\n            align-items: center;\n            gap: 12px;\n            padding: 16px;\n            background: var(--bg-secondary);\n            border-radius: 8px;\n        }\n        \n        .contact-icon {\n            width: 40px;\n            height: 40px;\n            background: var(--marine-cyan);\n            border-radius: 50%;\n            display: flex;\n            align-items: center;\n            justify-content: center;\n            color: #fff;\n            font-size: 1.2rem;\n        }\n        \n        .contact-details h4 { color: var(--text-primary); margin: 0 0 4px 0; font-size: 0.9rem; }\n        .contact-details a, .contact-details span { color: var(--accent-cyan); text-decoration: none; font-size: 0.95rem; }\n        .contact-details a:hover { text-decoration: underline; }\n        \n        footer {\n            background: var(--bg-secondary);\n            padding: 32px 0;\n            border-top: 1px solid var(--border-color);\n            text-align: center;\n        }\n        \n        footer p { color: var(--text-muted); font-size: 0.9rem; margin-bottom: 8px; }\n        \n        @media (max-width: 768px) {\n            h1 { font-size: 1.8rem; }\n            h2 { font-size: 1.4rem; }\n            .container { padding: 0 16px; }\n            .spec-table { font-size: 0.65rem; }\n            .spec-table th, .spec-table td { padding: 4px 6px; }\n            .parameter-grid { grid-template-columns: 1fr 1fr; }\n        }\n    <\/style>\n<\/head>\n<body>\n    <header>\n        <div class=\"container\">\n            <div class=\"header-content\">\n                <p class=\"company-name\">Anhui Feichun Special Cable Co., Ltd.<\/p>\n                <p class=\"company-name-cn\">\u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n                <h1>What is IEC 60092 Cable?<\/h1>\n                <p class=\"subtitle\">Complete Technical Guide to Marine &#038; Offshore Cable Standard \u2014 Shipboard Electrical Installations, BS 6883, NEK 606, Power &#038; Instrumentation Cables<\/p>\n                <div class=\"certification-badges\">\n                    <span class=\"cert-badge\">\ud83d\udea2 IEC 60092<\/span>\n                    <span class=\"cert-badge\">\ud83c\uddec\ud83c\udde7 BS 6883<\/span>\n                    <span class=\"cert-badge\">\ud83c\uddf3\ud83c\uddf4 NEK 606<\/span>\n                    <span class=\"cert-badge\">\u26a1 Up to 30kV<\/span>\n                    <span class=\"cert-badge\">\ud83d\udd25 Fire Resistant<\/span>\n                    <span class=\"cert-badge\">\ud83d\udee2\ufe0f MUD Resistant<\/span>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/header>\n    \n    <main>\n        <div class=\"container\">\n            <!-- Section 1: Introduction -->\n            <section>\n                <h2>1. Introduction to IEC 60092 Standard<\/h2>\n                \n                <p>IEC 60092 is the international standard for electrical installations in ships and fixed\/mobile marine applications. Ship wiring is covered by various national standards such as BS 6883 (British) and NEK 606 (Norwegian), and subject to third-party accreditations including Lloyd&#8217;s Register, DNV (Det Norske Veritas), and ABS (American Bureau of Shipping). As an international standard, IEC 60092 covers power and instrumentation cables for use on ships and in mobile marine environments.<\/p>\n                \n                <p>IEC 60092 cables are specifically designed for electrical installations in ships and offshore environments. These cables meet international standards, ensuring reliable power, control, and signal transmission in fixed and mobile marine applications. With robust construction and exceptional performance, IEC 60092 cables are the trusted choice for demanding marine and offshore projects.<\/p>\n                \n                <div class=\"highlight-box marine\">\n                    <div class=\"highlight-title\">\ud83d\udccb IEC 60092 Standard Family Overview<\/div>\n                    <table class=\"spec-table\" style=\"margin: 16px 0;\">\n                        <tr><td><strong>IEC 60092-350<\/strong><\/td><td>General construction and test methods for power, control, and instrumentation cables up to 18\/30(36)kV<\/td><\/tr>\n                        <tr><td><strong>IEC 60092-352<\/strong><\/td><td>Selection and installation of cables in fixed electrical systems up to 15kV on ships<\/td><\/tr>\n                        <tr><td><strong>IEC 60092-353<\/strong><\/td><td>Non-radial power cables with extruded solid insulation for 1kV and 3kV (including fire resistant)<\/td><\/tr>\n                        <tr><td><strong>IEC 60092-354<\/strong><\/td><td>Single and three-core power cables with conductor\/core screening for 6kV to 30kV<\/td><\/tr>\n                        <tr><td><strong>IEC 60092-360<\/strong><\/td><td>Electrical, mechanical characteristics of insulation and sheathing materials<\/td><\/tr>\n                        <tr><td><strong>IEC 60092-376<\/strong><\/td><td>Screened and unscreened cables for control and instrumentation circuits 150\/250V<\/td><\/tr>\n                    <\/table>\n                <\/div>\n                \n                <p class=\"citation\">Source: <a href=\"https:\/\/www.elandcables.com\/electrical-cable-and-accessories\/cables-by-standard\/iec60092-cable\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">Eland Cables &#8211; IEC 60092 Standard Cable<\/a><\/p>\n                \n                <div class=\"lang-section spanish\">\n                    <p><span class=\"lang-badge lang-es\">Espa\u00f1ol<\/span><strong>Introducci\u00f3n al Est\u00e1ndar IEC 60092<\/strong><\/p>\n                    <p>IEC 60092 es la norma internacional para instalaciones el\u00e9ctricas en buques y aplicaciones marinas fijas\/m\u00f3viles. El cableado de buques est\u00e1 cubierto por varias normas nacionales como BS 6883 (brit\u00e1nica) y NEK 606 (noruega), y est\u00e1 sujeto a acreditaciones de terceros incluyendo Lloyd&#8217;s Register, DNV y ABS. La familia de normas IEC 60092 incluye IEC 60092-350 (requisitos generales de construcci\u00f3n), IEC 60092-353 (cables de potencia 1kV\/3kV), IEC 60092-354 (cables de potencia 6kV-30kV), e IEC 60092-376 (cables de instrumentaci\u00f3n 150\/250V). Estos cables est\u00e1n dise\u00f1ados espec\u00edficamente para resistir ambientes marinos severos incluyendo vibraci\u00f3n, movimiento y exposici\u00f3n a aceites.<\/p>\n                <\/div>\n                \n                <div class=\"lang-section chinese\">\n                    <p><span class=\"lang-badge lang-zh\">\u7e41\u9ad4\u4e2d\u6587<\/span><strong>IEC 60092 \u6a19\u6e96\u7c21\u4ecb<\/strong><\/p>\n                    <p>IEC 60092\u662f\u8239\u8236\u548c\u56fa\u5b9a\/\u79fb\u52d5\u6d77\u6d0b\u61c9\u7528\u96fb\u6c23\u88dd\u7f6e\u7684\u570b\u969b\u6a19\u6e96\u3002\u8239\u8236\u4f48\u7dda\u7531\u5404\u7a2e\u570b\u5bb6\u6a19\u6e96\u8986\u84cb\uff0c\u5982BS 6883\uff08\u82f1\u570b\uff09\u548cNEK 606\uff08\u632a\u5a01\uff09\uff0c\u4e26\u53d7Lloyd&#8217;s Register\u3001DNV\u548cABS\u7b49\u7b2c\u4e09\u65b9\u8a8d\u8b49\u6a5f\u69cb\u7684\u8a8d\u8b49\u3002IEC 60092\u6a19\u6e96\u7cfb\u5217\u5305\u62ec\uff1aIEC 60092-350\uff08\u901a\u7528\u7d50\u69cb\u8981\u6c42\u548c\u6e2c\u8a66\u65b9\u6cd5\uff0c\u96fb\u58d3\u81f318\/30kV\uff09\u3001IEC 60092-352\uff08\u96fb\u7e9c\u9078\u64c7\u548c\u5b89\u88dd\uff09\u3001IEC 60092-353\uff081kV\u548c3kV\u64e0\u58d3\u7d55\u7de3\u96fb\u529b\u96fb\u7e9c\uff0c\u5305\u62ec\u8010\u706b\u96fb\u7e9c\uff09\u3001IEC 60092-354\uff086kV\u81f330kV\u4e2d\u9ad8\u58d3\u96fb\u529b\u96fb\u7e9c\uff09\u3001IEC 60092-360\uff08\u7d55\u7de3\u548c\u8b77\u5957\u6750\u6599\u7279\u6027\uff09\u3001IEC 60092-376\uff08150\/250V\u63a7\u5236\u548c\u5100\u8868\u96fb\u7e9c\uff09\u3002\u9019\u4e9b\u96fb\u7e9c\u5c08\u9580\u8a2d\u8a08\u7528\u65bc\u627f\u53d7\u56b4\u82db\u7684\u6d77\u6d0b\u74b0\u5883\uff0c\u5305\u62ec\u632f\u52d5\u3001\u904b\u52d5\u548c\u6cb9\u985e\u66b4\u9732\u3002<\/p>\n                <\/div>\n            <\/section>\n            \n            <!-- Section 2: Related Standards Comparison -->\n            <section>\n                <h2>2. Related Standards Comparison<\/h2>\n                \n                <p>IEC 60092 cables are complemented by national standards that provide additional specifications for marine and offshore applications. The main related standards are BS 6883 (British Standard for offshore), NEK 606 (Norwegian offshore standard), and BS 7917 (fire resistant cables).<\/p>\n                \n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Standard<\/th>\n                            <th>Origin<\/th>\n                            <th>Scope<\/th>\n                            <th>Key Features<\/th>\n                            <th>Certifications<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr class=\"header-iec\"><td colspan=\"5\">International Standards<\/td><\/tr>\n                        <tr>\n                            <td><span class=\"standard-badge std-iec\">IEC 60092<\/span><\/td>\n                            <td>International (IEC)<\/td>\n                            <td>Ships &#038; offshore units<\/td>\n                            <td>Power, control, instrumentation up to 30kV<\/td>\n                            <td>DNV, Lloyd&#8217;s, ABS<\/td>\n                        <\/tr>\n                        <tr class=\"header-bs\"><td colspan=\"5\">British Standards<\/td><\/tr>\n                        <tr>\n                            <td><span class=\"standard-badge std-bs\">BS 6883<\/span><\/td>\n                            <td>UK (BSI)<\/td>\n                            <td>Fixed offshore units, ships<\/td>\n                            <td>EPR insulation, SW4 sheath, HOFR<\/td>\n                            <td>Lloyd&#8217;s Register<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"standard-badge std-bs\">BS 7917<\/span><\/td>\n                            <td>UK (BSI)<\/td>\n                            <td>Fire resistant cables<\/td>\n                            <td>Mica tape fire barrier, 120min at 750\u00b0C<\/td>\n                            <td>Lloyd&#8217;s, DNV<\/td>\n                        <\/tr>\n                        <tr class=\"header-nek\"><td colspan=\"5\">Norwegian Standard<\/td><\/tr>\n                        <tr>\n                            <td><span class=\"standard-badge std-nek\">NEK TS 606<\/span><\/td>\n                            <td>Norway (NEK)<\/td>\n                            <td>Offshore oil &#038; gas<\/td>\n                            <td>MUD resistant, halogen-free, BFOU\/RFOU<\/td>\n                            <td>DNV, Lloyd&#8217;s, ABS<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <p class=\"citation\">Source: <a href=\"https:\/\/battcables.com\/product-category\/iec-60092-cable\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">Batt Cables &#8211; IEC 60092 Cable<\/a><\/p>\n            <\/section>\n            \n            <!-- Section 3: BS 6883 Cable Models -->\n            <section>\n                <h2>3. BS 6883 Type SW4 Marine Cables<\/h2>\n                \n                <p>BS 6883 is the British (and international) industry standard for the Offshore Oil and Gas, Ship Building and Marine Industries. These cables feature tinned annealed copper conductors complying with BS 6360\/IEC 60228, EPR insulation complying with BS 7655, and HOFR (Heat and Oil Resistant and Flame Retardant) halogen-free sheathing.<\/p>\n                \n                <div class=\"highlight-box fire\">\n                    <div class=\"highlight-title\">\ud83d\udd25 BS 6883 SW4 Cable Characteristics<\/div>\n                    <table class=\"spec-table\" style=\"margin: 16px 0;\">\n                        <tr><td><strong>Standard<\/strong><\/td><td>BS 6883 (Lloyd&#8217;s Register Approved)<\/td><\/tr>\n                        <tr><td><strong>Voltage Rating<\/strong><\/td><td>0.6\/1kV (power), 150\/250V (instrumentation)<\/td><\/tr>\n                        <tr><td><strong>Conductor<\/strong><\/td><td>Tinned annealed copper, Class 2 or Class 5 per EN 60228<\/td><\/tr>\n                        <tr><td><strong>Insulation<\/strong><\/td><td>Halogen-free EPR (Ethylene Propylene Rubber)<\/td><\/tr>\n                        <tr><td><strong>Sheath Type<\/strong><\/td><td>SW4 \u2014 HOFR halogen-free, flame retardant, heat\/oil resistant<\/td><\/tr>\n                        <tr><td><strong>Temperature Range<\/strong><\/td><td>-40\u00b0C to +90\u00b0C (fixed), -25\u00b0C to +90\u00b0C (flexed)<\/td><\/tr>\n                        <tr><td><strong>Fire Performance<\/strong><\/td><td>Flame retardant IEC 60332-3-22, Low smoke IEC 61034<\/td><\/tr>\n                    <\/table>\n                <\/div>\n                \n                <h3>3.1 BS 6883 Cable Model Comparison<\/h3>\n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>Type<\/th>\n                            <th>Voltage<\/th>\n                            <th>Armour<\/th>\n                            <th>Application<\/th>\n                            <th>Fire Performance<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bs\">657TQ<\/span><\/td>\n                            <td>SW4 Power<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Unarmoured<\/td>\n                            <td>Power, control, lighting<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bs\">658TQ<\/span><\/td>\n                            <td>SW4 Power<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>GSWB Armoured<\/td>\n                            <td>Power, control (mechanical protection)<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bs\">6571TQ<\/span><\/td>\n                            <td>SW4 Earth<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Unarmoured<\/td>\n                            <td>Earth\/protective conductor<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <p class=\"citation\">Source: <a href=\"https:\/\/www.elandcables.com\/cables\/bs-6883-sw4-marine-power-lighting-control-cable\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">Eland Cables &#8211; BS 6883 SW4 Marine Cable<\/a><\/p>\n            <\/section>\n            \n            <!-- Section 4: NEK 606 Cables -->\n            <section>\n                <h2>4. NEK TS 606 Offshore Cables (BFOU &#038; RFOU)<\/h2>\n                \n                <p>NEK TS 606 is the Norwegian offshore industry technical specification covering a range of power, instrumentation and earth cables that are halogen-free and\/or MUD resistant. The NEK 606 cable standard has been widely adopted internationally with BFOU (fire resistant) and RFOU (flame retardant) cables in common use for offshore oil and gas applications.<\/p>\n                \n                <div class=\"marine-box\">\n                    <h3>\u26a1 NEK 606 Cable Code Designation<\/h3>\n                    <table class=\"spec-table\" style=\"margin: 16px 0;\">\n                        <tr><td><strong>B<\/strong><\/td><td>Fire resistant insulation (with mica glass tape) \u2014 maintains circuit integrity during fire<\/td><\/tr>\n                        <tr><td><strong>R \/ T<\/strong><\/td><td>Flame retardant insulation \u2014 EPR (R) or XLPE (T)<\/td><\/tr>\n                        <tr><td><strong>F<\/strong><\/td><td>Inner sheath\/bedding present<\/td><\/tr>\n                        <tr><td><strong>O<\/strong><\/td><td>Wire braid armour (tinned copper wire braid TCWB)<\/td><\/tr>\n                        <tr><td><strong>U<\/strong><\/td><td>Outer sheath (halogen-free, MUD resistant)<\/td><\/tr>\n                        <tr><td><strong>(i)<\/strong><\/td><td>Individual screen \u2014 each pair separately screened<\/td><\/tr>\n                        <tr><td><strong>(c)<\/strong><\/td><td>Collective screen \u2014 single screen over all pairs<\/td><\/tr>\n                    <\/table>\n                <\/div>\n                \n                <h3>4.1 NEK 606 Power Cable Models<\/h3>\n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>Code<\/th>\n                            <th>Voltage (U\u2080\/U)<\/th>\n                            <th>Type<\/th>\n                            <th>Fire Performance<\/th>\n                            <th>Application<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr class=\"header-power\"><td colspan=\"6\">Low Voltage Power Cables (0.6\/1kV)<\/td><\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU P101<\/span><\/td>\n                            <td>P101<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Flame Retardant<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">IEC 60332-3-22<\/span><\/td>\n                            <td>General power distribution<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bfou\">BFOU P105<\/span><\/td>\n                            <td>P105<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Fire Resistant<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">IEC 60331<\/span><\/td>\n                            <td>Emergency systems, critical circuits<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">UX P108<\/span><\/td>\n                            <td>P108<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Earth Cable<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">IEC 60332-1<\/span><\/td>\n                            <td>Earth\/protective conductor<\/td>\n                        <\/tr>\n                        <tr class=\"header-power\"><td colspan=\"6\">Medium Voltage Power Cables (3.6kV &#8211; 18\/30kV)<\/td><\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU P102<\/span><\/td>\n                            <td>P102<\/td>\n                            <td>3.6\/6kV<\/td>\n                            <td>Flame Retardant<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">IEC 60332-3-22<\/span><\/td>\n                            <td>MV power distribution<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU P103<\/span><\/td>\n                            <td>P103<\/td>\n                            <td>6\/10kV<\/td>\n                            <td>Flame Retardant<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">IEC 60332-3-22<\/span><\/td>\n                            <td>MV power distribution<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU P104<\/span><\/td>\n                            <td>P104<\/td>\n                            <td>8.7\/15kV<\/td>\n                            <td>Flame Retardant<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">IEC 60332-3-22<\/span><\/td>\n                            <td>MV power distribution<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU P112<\/span><\/td>\n                            <td>P112<\/td>\n                            <td>12\/20kV<\/td>\n                            <td>Flame Retardant<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">IEC 60332-3-22<\/span><\/td>\n                            <td>HV power distribution<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU P113<\/span><\/td>\n                            <td>P113<\/td>\n                            <td>18\/30kV<\/td>\n                            <td>Flame Retardant<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">IEC 60332-3-22<\/span><\/td>\n                            <td>HV power distribution<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <h3>4.2 NEK 606 Instrumentation Cable Models<\/h3>\n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>Code<\/th>\n                            <th>Voltage<\/th>\n                            <th>Screen<\/th>\n                            <th>Fire Performance<\/th>\n                            <th>Application<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr class=\"header-inst\"><td colspan=\"6\">Instrumentation Cables (150\/250V)<\/td><\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU(i) S101<\/span><\/td>\n                            <td>S101<\/td>\n                            <td>150\/250V<\/td>\n                            <td>Individual<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Analog signals 4-20mA<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-rfou\">RFOU(c) S102<\/span><\/td>\n                            <td>S102<\/td>\n                            <td>150\/250V<\/td>\n                            <td>Collective<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Digital signals<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bfou\">BFOU(i) S103<\/span><\/td>\n                            <td>S103<\/td>\n                            <td>150\/250V<\/td>\n                            <td>Individual<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">Fire Resistant<\/span><\/td>\n                            <td>Emergency instrumentation<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bfou\">BFOU(c) S104<\/span><\/td>\n                            <td>S104<\/td>\n                            <td>150\/250V<\/td>\n                            <td>Collective<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">Fire Resistant<\/span><\/td>\n                            <td>Emergency control circuits<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <p class=\"citation\">Source: <a href=\"https:\/\/www.elandcables.com\/electrical-cable-and-accessories\/cables-by-standard\/nek-606-cable\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">Eland Cables &#8211; NEK 606 Standard Cable<\/a><\/p>\n            <\/section>\n            \n            <!-- Section 5: IEC 60092 Cable Models -->\n            <section>\n                <h2>5. IEC 60092 Series Cable Models<\/h2>\n                \n                <p>IEC 60092-353 covers power cables for 1kV and 3kV, while IEC 60092-354 covers medium to high voltage cables from 6kV to 30kV. IEC 60092-376 specifies control and instrumentation cables at 150\/250V.<\/p>\n                \n                <h3>5.1 IEC 60092-353 Power Cables (0.6\/1kV &#8211; 1.8\/3kV)<\/h3>\n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>Standard<\/th>\n                            <th>Voltage<\/th>\n                            <th>Armour<\/th>\n                            <th>Fire Performance<\/th>\n                            <th>Application<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XI 0.6\/1kV<\/span><\/td>\n                            <td>IEC 60092-353<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Unarmoured<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Power distribution<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XAI 0.6\/1kV<\/span><\/td>\n                            <td>IEC 60092-353<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Armoured<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Mechanical protection areas<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XAI 331 0.6\/1kV<\/span><\/td>\n                            <td>IEC 60092-353<\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>Armoured + Fire Barrier<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">Fire Resistant<\/span><\/td>\n                            <td>Emergency circuits<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <h3>5.2 IEC 60092-354 Medium\/High Voltage Power Cables<\/h3>\n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>Standard<\/th>\n                            <th>Voltage (U\u2080\/U)<\/th>\n                            <th>Um (kV)<\/th>\n                            <th>Construction<\/th>\n                            <th>Application<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td><span class=\"cable-badge badge-iec\">XAI 3.6\/6kV<\/span><\/td>\n                            <td>IEC 60092-354<\/td>\n                            <td>3.6\/6kV<\/td>\n                            <td>7.2<\/td>\n                            <td>Conductor + core screen, armoured<\/td>\n                            <td>MV power<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-iec\">XAI 6\/10kV<\/span><\/td>\n                            <td>IEC 60092-354<\/td>\n                            <td>6\/10kV<\/td>\n                            <td>12<\/td>\n                            <td>Conductor + core screen, armoured<\/td>\n                            <td>MV power<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-iec\">XAI 8.7\/15kV<\/span><\/td>\n                            <td>IEC 60092-354<\/td>\n                            <td>8.7\/15kV<\/td>\n                            <td>17.5<\/td>\n                            <td>Conductor + core screen, armoured<\/td>\n                            <td>MV power<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-iec\">XAI 12\/20kV<\/span><\/td>\n                            <td>IEC 60092-354<\/td>\n                            <td>12\/20kV<\/td>\n                            <td>24<\/td>\n                            <td>Conductor + core screen, armoured<\/td>\n                            <td>HV power<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-iec\">XAI 18\/30kV<\/span><\/td>\n                            <td>IEC 60092-354<\/td>\n                            <td>18\/30kV<\/td>\n                            <td>36<\/td>\n                            <td>Conductor + core screen, armoured<\/td>\n                            <td>HV power<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <h3>5.3 IEC 60092-376 Instrumentation Cables (150\/250V)<\/h3>\n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>Voltage<\/th>\n                            <th>Screen<\/th>\n                            <th>Armour<\/th>\n                            <th>Fire Performance<\/th>\n                            <th>Application<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XI(i) 150\/250V<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Individual<\/td>\n                            <td>Unarmoured<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Instrumentation<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XI(c) 150\/250V<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Collective<\/td>\n                            <td>Unarmoured<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Control circuits<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XAI(i) 150\/250V<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Individual<\/td>\n                            <td>Armoured<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Instrumentation (protected)<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XAI(c) 150\/250V<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Collective<\/td>\n                            <td>Armoured<\/td>\n                            <td><span class=\"fire-badge flame-retardant\">Flame Retardant<\/span><\/td>\n                            <td>Control (protected)<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XAI(i) 331 150\/250V<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Individual<\/td>\n                            <td>Armoured + Mica<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">Fire Resistant<\/span><\/td>\n                            <td>Emergency instrumentation<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-xi\">XAI(c) 331 150\/250V<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Collective<\/td>\n                            <td>Armoured + Mica<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">Fire Resistant<\/span><\/td>\n                            <td>Emergency control<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <p class=\"citation\">Source: <a href=\"https:\/\/standards.globalspec.com\/std\/10044885\/IEC%2060092-353\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">GlobalSpec &#8211; IEC 60092-353<\/a><\/p>\n            <\/section>\n            \n            <!-- Section 6: BS 7917 Fire Resistant Cables -->\n            <section>\n                <h2>6. BS 7917 Fire Resistant Cables<\/h2>\n                \n                <p>BS 7917 covers fire resistant cables with enhanced circuit integrity. These cables use mica glass tape (MGT) as a fire barrier over the conductor, enabling the cable to maintain circuit integrity for at least 120 minutes at 750\u00b0C according to IEC 60331.<\/p>\n                \n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Model<\/th>\n                            <th>Voltage<\/th>\n                            <th>Screen<\/th>\n                            <th>Armour<\/th>\n                            <th>Fire Rating<\/th>\n                            <th>Application<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bs\">TCu\/MGT\/EPR\/IS\/ZH\/GSWB\/ZH<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Individual<\/td>\n                            <td>GSWB<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">120min @ 750\u00b0C<\/span><\/td>\n                            <td>Emergency instrumentation<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bs\">TCu\/MGT\/EPR\/CS\/ZH\/GSWB\/ZH<\/span><\/td>\n                            <td>150\/250V<\/td>\n                            <td>Collective<\/td>\n                            <td>GSWB<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">120min @ 750\u00b0C<\/span><\/td>\n                            <td>Emergency control<\/td>\n                        <\/tr>\n                        <tr>\n                            <td><span class=\"cable-badge badge-bs\">TCu\/MGT\/EPR\/ZH\/GSWB\/ZH SW4<\/span><\/td>\n                            <td>0.6\/1kV<\/td>\n                            <td>\u2014<\/td>\n                            <td>GSWB<\/td>\n                            <td><span class=\"fire-badge fire-resistant\">120min @ 750\u00b0C<\/span><\/td>\n                            <td>Emergency power<\/td>\n                        <\/tr>\n                    <\/tbody>\n                <\/table>\n                \n                <p><strong>Construction Key:<\/strong> TCu = Tinned Copper, MGT = Mica Glass Tape fire barrier, EPR = Ethylene Propylene Rubber insulation, IS = Individual Screen, CS = Collective Screen, ZH = Zero Halogen sheath, GSWB = Galvanized Steel Wire Braid armour.<\/p>\n            <\/section>\n            \n            <!-- Section 7: Fire Performance Comparison -->\n            <section>\n                <h2>7. Fire Performance Comparison<\/h2>\n                \n                <div class=\"highlight-box fire\">\n                    <div class=\"highlight-title\">\ud83d\udd25 BFOU vs RFOU \u2014 Critical Selection Criteria<\/div>\n                    <table class=\"spec-table\" style=\"margin: 16px 0;\">\n                        <thead>\n                            <tr>\n                                <th>Property<\/th>\n                                <th>BFOU (Fire Resistant)<\/th>\n                                <th>RFOU (Flame Retardant)<\/th>\n                            <\/tr>\n                        <\/thead>\n                        <tbody>\n                            <tr><td>Fire Barrier<\/td><td>Mica glass tape (MGT)<\/td><td>None<\/td><\/tr>\n                            <tr><td>Circuit Integrity<\/td><td>Maintained during fire (2-3 hours)<\/td><td>NOT maintained during fire<\/td><\/tr>\n                            <tr><td>Test Standard<\/td><td>IEC 60331-21<\/td><td>IEC 60332-3-22<\/td><\/tr>\n                            <tr><td>Fire Temperature<\/td><td>750-830\u00b0C sustained<\/td><td>Self-extinguishing only<\/td><\/tr>\n                            <tr><td>Application<\/td><td>Emergency systems, fire alarms, evacuation<\/td><td>General power, non-critical circuits<\/td><\/tr>\n                            <tr><td>Cost<\/td><td>Higher (mica tape layer)<\/td><td>Standard<\/td><\/tr>\n                        <\/tbody>\n                    <\/table>\n                    <p style=\"color: var(--accent-red); font-weight: 600; font-size: 0.9rem;\">\u26a0\ufe0f Emergency systems, fire detection, emergency lighting, and life safety circuits MUST use fire resistant (BFOU) cables!<\/p>\n                <\/div>\n                \n                <p class=\"citation\">Source: <a href=\"https:\/\/www.elandcables.com\/cables\/bfou-and-rfou-cables\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">Eland Cables &#8211; BFOU &#038; RFOU Cables<\/a><\/p>\n            <\/section>\n            \n            <!-- Section 8: Complete Cable Model Summary -->\n            <section>\n                <h2>8. Complete Cable Model Summary<\/h2>\n                \n                <table class=\"spec-table\">\n                    <thead>\n                        <tr>\n                            <th>Standard<\/th>\n                            <th>Model<\/th>\n                            <th>Voltage<\/th>\n                            <th>Type<\/th>\n                            <th>Armour<\/th>\n                            <th>Fire<\/th>\n                        <\/tr>\n                    <\/thead>\n                    <tbody>\n                        <tr class=\"header-bs\"><td colspan=\"6\">BS 6883 Type SW4<\/td><\/tr>\n                        <tr><td>BS 6883<\/td><td>657TQ<\/td><td>0.6\/1kV<\/td><td>Power<\/td><td>No<\/td><td>FR<\/td><\/tr>\n                        <tr><td>BS 6883<\/td><td>658TQ<\/td><td>0.6\/1kV<\/td><td>Power<\/td><td>GSWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>BS 6883<\/td><td>6571TQ<\/td><td>0.6\/1kV<\/td><td>Earth<\/td><td>No<\/td><td>FR<\/td><\/tr>\n                        <tr class=\"header-nek\"><td colspan=\"6\">NEK 606 Power Cables<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU P101<\/td><td>0.6\/1kV<\/td><td>Power<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>BFOU P105<\/td><td>0.6\/1kV<\/td><td>Power<\/td><td>TCWB<\/td><td>Fire Res<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>UX P108<\/td><td>0.6\/1kV<\/td><td>Earth<\/td><td>No<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU P102<\/td><td>3.6\/6kV<\/td><td>Power<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU P103<\/td><td>6\/10kV<\/td><td>Power<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU P104<\/td><td>8.7\/15kV<\/td><td>Power<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU P112<\/td><td>12\/20kV<\/td><td>Power<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU P113<\/td><td>18\/30kV<\/td><td>Power<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr class=\"header-nek\"><td colspan=\"6\">NEK 606 Instrumentation Cables<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU(i) S101<\/td><td>150\/250V<\/td><td>Inst (i)<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>RFOU(c) S102<\/td><td>150\/250V<\/td><td>Inst (c)<\/td><td>TCWB<\/td><td>FR<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>BFOU(i) S103<\/td><td>150\/250V<\/td><td>Inst (i)<\/td><td>TCWB<\/td><td>Fire Res<\/td><\/tr>\n                        <tr><td>NEK 606<\/td><td>BFOU(c) S104<\/td><td>150\/250V<\/td><td>Inst (c)<\/td><td>TCWB<\/td><td>Fire Res<\/td><\/tr>\n                        <tr class=\"header-iec\"><td colspan=\"6\">IEC 60092-353 Power Cables<\/td><\/tr>\n                        <tr><td>IEC 60092-353<\/td><td>XI 0.6\/1kV<\/td><td>0.6\/1kV<\/td><td>Power<\/td><td>No<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-353<\/td><td>XAI 0.6\/1kV<\/td><td>0.6\/1kV<\/td><td>Power<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-353<\/td><td>XAI 331 0.6\/1kV<\/td><td>0.6\/1kV<\/td><td>Power<\/td><td>Yes+MGT<\/td><td>Fire Res<\/td><\/tr>\n                        <tr class=\"header-iec\"><td colspan=\"6\">IEC 60092-354 MV\/HV Power Cables<\/td><\/tr>\n                        <tr><td>IEC 60092-354<\/td><td>XAI 3.6\/6kV<\/td><td>3.6\/6kV<\/td><td>Power<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-354<\/td><td>XAI 6\/10kV<\/td><td>6\/10kV<\/td><td>Power<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-354<\/td><td>XAI 8.7\/15kV<\/td><td>8.7\/15kV<\/td><td>Power<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-354<\/td><td>XAI 12\/20kV<\/td><td>12\/20kV<\/td><td>Power<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-354<\/td><td>XAI 18\/30kV<\/td><td>18\/30kV<\/td><td>Power<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr class=\"header-iec\"><td colspan=\"6\">IEC 60092-376 Instrumentation Cables<\/td><\/tr>\n                        <tr><td>IEC 60092-376<\/td><td>XI(i) 150\/250V<\/td><td>150\/250V<\/td><td>Inst (i)<\/td><td>No<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-376<\/td><td>XI(c) 150\/250V<\/td><td>150\/250V<\/td><td>Inst (c)<\/td><td>No<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-376<\/td><td>XAI(i) 150\/250V<\/td><td>150\/250V<\/td><td>Inst (i)<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-376<\/td><td>XAI(c) 150\/250V<\/td><td>150\/250V<\/td><td>Inst (c)<\/td><td>Yes<\/td><td>FR<\/td><\/tr>\n                        <tr><td>IEC 60092-376<\/td><td>XAI(i) 331<\/td><td>150\/250V<\/td><td>Inst (i)<\/td><td>Yes+MGT<\/td><td>Fire Res<\/td><\/tr>\n                        <tr><td>IEC 60092-376<\/td><td>XAI(c) 331<\/td><td>150\/250V<\/td><td>Inst (c)<\/td><td>Yes+MGT<\/td><td>Fire Res<\/td><\/tr>\n                    <\/tbody>\n                <\/table>\n                <p style=\"font-size: 0.8rem; color: var(--text-muted);\">Legend: FR = Flame Retardant (IEC 60332), Fire Res = Fire Resistant (IEC 60331), (i) = Individual screen, (c) = Collective screen, GSWB = Galvanized Steel Wire Braid, TCWB = Tinned Copper Wire Braid, MGT = Mica Glass Tape<\/p>\n            <\/section>\n            \n            <!-- Section 9: Key Parameters -->\n            <section>\n                <h2>9. Key Technical Parameters<\/h2>\n                \n                <div class=\"parameter-grid\">\n                    <div class=\"parameter-card\">\n                        <h4>Voltage Range<\/h4>\n                        <div class=\"parameter-value\">150V &#8211; 30kV<\/div>\n                        <div class=\"parameter-unit\">U\u2080\/U rating<\/div>\n                    <\/div>\n                    <div class=\"parameter-card\">\n                        <h4>Conductor<\/h4>\n                        <div class=\"parameter-value\">Tinned Cu<\/div>\n                        <div class=\"parameter-unit\">Class 2\/5 EN 60228<\/div>\n                    <\/div>\n                    <div class=\"parameter-card\">\n                        <h4>Temp Range<\/h4>\n                        <div class=\"parameter-value\">-40\u00b0C to +90\u00b0C<\/div>\n                        <div class=\"parameter-unit\">Operating<\/div>\n                    <\/div>\n                    <div class=\"parameter-card\">\n                        <h4>Fire Test<\/h4>\n                        <div class=\"parameter-value\">750\u00b0C<\/div>\n                        <div class=\"parameter-unit\">IEC 60331<\/div>\n                    <\/div>\n                    <div class=\"parameter-card\">\n                        <h4>Insulation<\/h4>\n                        <div class=\"parameter-value\">EPR \/ XLPE<\/div>\n                        <div class=\"parameter-unit\">Halogen-free<\/div>\n                    <\/div>\n                    <div class=\"parameter-card\">\n                        <h4>Sheath<\/h4>\n                        <div class=\"parameter-value\">LSZH \/ HOFR<\/div>\n                        <div class=\"parameter-unit\">MUD resistant<\/div>\n                    <\/div>\n                <\/div>\n            <\/section>\n            \n            <!-- External Sources -->\n            <section>\n                <div class=\"external-sources\">\n                    <h3>Authoritative External References<\/h3>\n                    <div class=\"source-list\">\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>Eland Cables &#8211; IEC 60092 Standard Cable<\/strong><br>\n                                <a href=\"https:\/\/www.elandcables.com\/electrical-cable-and-accessories\/cables-by-standard\/iec60092-cable\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/www.elandcables.com\/&#8230;\/iec60092-cable<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>Eland Cables &#8211; NEK 606 Standard Cable<\/strong><br>\n                                <a href=\"https:\/\/www.elandcables.com\/electrical-cable-and-accessories\/cables-by-standard\/nek-606-cable\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/www.elandcables.com\/&#8230;\/nek-606-cable<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>Eland Cables &#8211; BFOU &#038; RFOU Cables<\/strong><br>\n                                <a href=\"https:\/\/www.elandcables.com\/cables\/bfou-and-rfou-cables\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/www.elandcables.com\/cables\/bfou-and-rfou-cables<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>Eland Cables &#8211; BS 6883 SW4 Marine Cable<\/strong><br>\n                                <a href=\"https:\/\/www.elandcables.com\/cables\/bs-6883-sw4-marine-power-lighting-control-cable\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/www.elandcables.com\/&#8230;\/bs-6883-sw4<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>GlobalSpec &#8211; IEC 60092-353<\/strong><br>\n                                <a href=\"https:\/\/standards.globalspec.com\/std\/10044885\/IEC%2060092-353\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/standards.globalspec.com\/&#8230;\/IEC60092-353<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>GlobalSpec &#8211; IEC 60092-376<\/strong><br>\n                                <a href=\"https:\/\/standards.globalspec.com\/std\/10158085\/IEC%2060092-376\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/standards.globalspec.com\/&#8230;\/IEC60092-376<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>IEC Webstore &#8211; IEC 60092-353:2024<\/strong><br>\n                                <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/72868\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/webstore.iec.ch\/&#8230;\/72868<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>Batt Cables &#8211; IEC 60092 Cable<\/strong><br>\n                                <a href=\"https:\/\/battcables.com\/product-category\/iec-60092-cable\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/battcables.com\/&#8230;\/iec-60092-cable<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>Habia &#8211; BFOU and RFOU Cables NEK TS 606<\/strong><br>\n                                <a href=\"https:\/\/www.habia.com\/en\/products\/industry-standard-cables\/bfou-and-rfou-cables\/\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/www.habia.com\/&#8230;\/bfou-and-rfou-cables<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"source-item\">\n                            <span class=\"source-icon\">\u25cf<\/span>\n                            <div>\n                                <strong>Prysmian\/Draka &#8211; NEK606 Products<\/strong><br>\n                                <a href=\"https:\/\/nl.prysmian.com\/en\/products-and-services\/products\/nek606\" rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"source-ref\">https:\/\/nl.prysmian.com\/&#8230;\/nek606<\/a>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                <\/div>\n            <\/section>\n            \n            <!-- Contact Section -->\n            <section>\n                <div class=\"contact-section\">\n                    <h2 style=\"color: var(--marine-cyan); border: none; padding: 0; margin-bottom: 8px;\">Contact Feichun Cable<\/h2>\n                    <p style=\"color: var(--text-secondary);\">For technical support with IEC 60092 marine cables, NEK 606 offshore cables, BS 6883 shipwiring, or BFOU\/RFOU applications, please contact our engineering team.<\/p>\n                    \n                    <div class=\"contact-grid\">\n                        <div class=\"contact-item\">\n                            <div class=\"contact-icon\">\ud83d\udcf1<\/div>\n                            <div class=\"contact-details\">\n                                <h4>WhatsApp<\/h4>\n                                <a href=\"https:\/\/wa.me\/8613855123218\" target=\"_blank\" rel=\"noopener\">+86 138 5512 3218<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"contact-item\">\n                            <div class=\"contact-icon\">\ud83d\udce7<\/div>\n                            <div class=\"contact-details\">\n                                <h4>Technical Support<\/h4>\n                                <a href=\"mailto:tech@feichuncables.com\">tech@feichuncables.com<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"contact-item\">\n                            <div class=\"contact-icon\">\ud83d\udc64<\/div>\n                            <div class=\"contact-details\">\n                                <h4>Sales &#8211; Mr. Zihao Yang<\/h4>\n                                <a href=\"mailto:zihao.yang@feichuncable.com\">zihao.yang@feichuncable.com<\/a>\n                            <\/div>\n                        <\/div>\n                        <div class=\"contact-item\">\n                            <div class=\"contact-icon\">\ud83d\udc64<\/div>\n                            <div class=\"contact-details\">\n                                <h4>Sales &#8211; Mr. Ziyu Huang<\/h4>\n                                <a href=\"mailto:ziyu.huang@feichuncables.com\">ziyu.huang@feichuncables.com<\/a>\n                            <\/div>\n                        <\/div>\n                    <\/div>\n                <\/div>\n            <\/section>\n        <\/div>\n    <\/main>\n    \n    <footer>\n        <div class=\"container\">\n            <p><strong>Anhui Feichun Special Cable Co., Ltd.<\/strong> | \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8<\/p>\n            <p>Professional Manufacturer of IEC 60092, NEK 606 &#038; BS 6883 Marine &#038; Offshore Cables<\/p>\n            <p style=\"margin-top: 16px; font-size: 0.8rem;\">\u00a9 2025 Feichun Cable. All rights reserved.<\/p>\n        <\/div>\n    <\/footer>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"IEC 60092 cable, marine cable, shipboard cable, offshore cable, BS 6883 cable, NEK 606 cable, BFOU cable, RFOU cable, 657TQ cable, 658TQ cable, fire resistant marine cable, flame retardant cable, ship wiring, offshore platform cable, Lloyd&#8217;s Register approved, DNV certified, halogen free cable, LSZH marine cable, MUD resistant cable, IEC 60092-353, IEC 60092-354, IEC 60092-376, SW4 cable, EPR insulated, TCWB armoured, instrumentation cable, control cable, emergency power cable, oil rig cable, Feichun cable","protected":false},"author":1,"featured_media":4017,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[1],"tags":[21966,21929,21934,20610,21949,14400,21947,14398,21948,21932,3165,15325,21951,21962,21953,21959,21946,20504,20503,21945,21944,20515,21926,21925,1034,21939,21921,21935,20412,20665,1147,21918,3778,21930,4491,11434,21924,774,14409,21922,830,21933,13608,20446,20349,407,21917,408,20351,409,410,1029,21936,21914,3166,15950,385,5916,20566,20417,20534,397,21919,386,21950,21928,21965,1028,21923,21938,5374,10026,14517,21963,15296,21960,21952,21955,21954,21957,21958,992,21937,21915,1016,21920,20528,20505,21916,21961,21964,21940,21956,21931,21927,21943,21942,21941],"class_list":["post-4016","post","type-post","status-publish","format-standard","has-post-thumbnail","category-uncategorized","tag-c-collective-screen","tag-1-8-3kv-marine-cable-xi-cable","tag-18-30kv-marine-cable-conductor-screening","tag-6571tq-cable","tag-6571tq-sw4-cable","tag-657tq-cable","tag-657tq-sw4-cable","tag-658tq-cable","tag-658tq-sw4-cable","tag-8-7-15kv-marine-cable-12-20kv-marine-cable","tag-abs-approved-cable","tag-bfou-cable","tag-bfou-fire-resistant","tag-bfou-meaning","tag-bfou-p105-0-6-1kv-rfou-p102-3-6-6kv","tag-bfouc-s104-250v","tag-british-marine-cable-standard-lloyds-register-approved-cable","tag-bs-6883","tag-bs-6883-cable","tag-bs-6883-marine-cable-bs-6883-offshore-cable","tag-bs-6883-sw4-cable","tag-bs-7917","tag-cable-installation-ships","tag-cable-selection-installation","tag-control-cable","tag-control-cable-150-250v-marine-cable","tag-copper-conductor-marine-18-30kv-marine-cable","tag-core-screening","tag-dnv-approved-cable","tag-dnv-certified","tag-emergency-power-cable","tag-en-60092","tag-epr-insulated","tag-extruded-insulation-0-6-1kv-marine-cable","tag-feichun-cable","tag-fire-resistant-marine-cable","tag-fixed-electrical-systems-15kv-shipboard-cable","tag-flame-retardant-cable","tag-flame-retardant-marine-cable","tag-general-construction-cable","tag-halogen-free-cable","tag-high-voltage-marine-cable-6-10kv-marine-cable","tag-hofr-cable","tag-iec-60092","tag-iec-60092-cable","tag-iec-60092-350","tag-iec-60092-352","tag-iec-60092-353","tag-iec-60092-354","tag-iec-60092-360","tag-iec-60092-376","tag-instrumentation-cable","tag-insulation-materials","tag-lloyds-register-approved","tag-lloyds-register-cable","tag-lszh-marine-cable","tag-marine-cable","tag-marine-power-cable","tag-medium-voltage-marine-cable","tag-mud-resistant-cable","tag-nek-606","tag-nek-606-cable","tag-nek-6062022","tag-nek-ts-606","tag-nek-ts-606-cable","tag-non-radial-power-cable","tag-o-wire-braid","tag-offshore-cable","tag-offshore-cable-construction","tag-offshore-cable-materials","tag-offshore-platform-cable","tag-offshore-power-cable","tag-oil-rig-cable","tag-r-flame-retardant-epr-f-inner-sheath","tag-rfou-cable","tag-rfou-meaning","tag-rfou-p101-0-6-1kv","tag-rfou-p103-6-10kv-rfou-p104-8-7-15kv","tag-rfou-p112-12-20kv-rfou-p113-18-30kv","tag-rfouc-s102-250v-bfoui-s103-250v","tag-rfoui-s101-250v","tag-screened-cable","tag-sheathing-materials-shipboard-cable-materials","tag-ship-wiring","tag-shipboard-cable","tag-shipboard-test-methods-power-control-instrumentation-cable","tag-sw4-cable","tag-sw4-sheath","tag-tcwb-armoured","tag-tfou-cable-b-fire-resistant","tag-u-outer-sheath-i-individual-screen","tag-unscreened-cable-xii-cable","tag-ux-p108-earth-cable","tag-xai-331-fire-resistant","tag-xai-cable","tag-xaic-cable","tag-xaii-cable","tag-xic-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4016","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=4016"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4016\/revisions"}],"predecessor-version":[{"id":4018,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/4016\/revisions\/4018"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/4017"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=4016"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=4016"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=4016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}