{"id":3552,"date":"2025-12-25T14:20:44","date_gmt":"2025-12-25T06:20:44","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=3552"},"modified":"2025-12-25T14:21:05","modified_gmt":"2025-12-25T06:21:05","slug":"gexol-331hf-power-cable-3","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/gexol-331hf-power-cable-3\/","title":{"rendered":"GEXOL\u00ae-331HF\u00a0Power Cable"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">5 CONDUCTOR \u4e94\u82af<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Low Smoke Halogen-Free \u2022 Extremely Flexible \u2022 0.6\/1kV \u2022 Rated 90\u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f4e\u7159\u7121\u9e75 \u2022 \u6975\u5ea6\u67d4\u8edf \u2022 0.6\/1kV\u984d\u5b9a\u96fb\u58d3 \u2022 90\u00b0C\u984d\u5b9a\u6eab\u5ea6<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img data-dominant-color=\"e7e3e0\" data-has-transparency=\"false\" loading=\"lazy\" decoding=\"async\" width=\"493\" height=\"628\" sizes=\"auto, (max-width: 493px) 100vw, 493px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-394-493x628.avif\" alt=\"\" class=\"wp-image-3553 not-transparent\" style=\"--dominant-color: #e7e3e0; width:640px;height:auto\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-394-493x628.avif 493w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-394-236x300.avif 236w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-394-400x509.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-394.avif 605w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"zh-Hant\">\n<head>\n    <meta charset=\"UTF-8\">\n    <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n    <meta name=\"description\" content=\"GEXOL\u00ae-331HF Fire Resistant Five Conductor Power Cable - Low Smoke Halogen-Free, 0.6\/1kV, 90\u00b0C Rated. Complete technical specifications by Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98db\u7d14\u7279\u7a2e\u96fb\u7e9c\u6709\u9650\u516c\u53f8\">\n    <meta name=\"keywords\" content=\"GEXOL-331HF, five conductor cable, 5 conductor power cable, fire resistant cable, low smoke halogen-free, LSZH cable, 0.6\/1kV power cable, marine cable, offshore cable, IEEE 1580, IEC 60331\">\n    <title>GEXOL\u00ae-331HF \u8010\u706b\u4e94\u82af\u96fb\u529b\u96fb\u7e9c | Fire Resistant Five Conductor Power Cable &#8211; \u5b89\u5fbd\u98db\u7d14\u7279\u7a2e\u96fb\u7e9c\u6709\u9650\u516c\u53f8<\/title>\n    <link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n    <link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n    <link href=\"https:\/\/fonts.googleapis.com\/css2?family=Noto+Sans+TC:wght@400;500;700&#038;family=Inter:wght@400;500;600;700&#038;family=Source+Code+Pro:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n    <style>\n        :root {\n            --bg-primary: #0a0d12;\n            --bg-secondary: #10151c;\n            --bg-tertiary: #181f2a;\n            --bg-card: #141a24;\n            --bg-highlight: #1c2534;\n            --text-primary: #eceff4;\n            --text-secondary: #a0aab8;\n            --text-muted: #6c7688;\n            --accent-blue: #5dadec;\n            --accent-green: #50c878;\n            --accent-yellow: #f5c842;\n            --accent-red: #f07178;\n            --accent-purple: #bb86fc;\n            --accent-cyan: #56c8d8;\n            --accent-orange: #ff9f43;\n            --accent-teal: #26a69a;\n            --border-color: #262f3d;\n            --border-subtle: #1c2430;\n            --font-sans: 'Inter', 'Noto Sans TC', -apple-system, BlinkMacSystemFont, sans-serif;\n            --font-mono: 'Source Code Pro', 'Consolas', monospace;\n        }\n\n        *, *::before, *::after {\n            box-sizing: border-box;\n            margin: 0;\n            padding: 0;\n        }\n\n        html {\n            font-size: 16px;\n            scroll-behavior: smooth;\n        }\n\n        body {\n            font-family: var(--font-sans);\n            background-color: var(--bg-primary);\n            color: var(--text-primary);\n            line-height: 1.75;\n            min-height: 100vh;\n        }\n\n        .container {\n            width: 100%;\n            max-width: 1380px;\n            margin: 0 auto;\n            padding: 0 26px;\n        }\n\n        \/* Header *\/\n        header {\n            background: var(--bg-secondary);\n            border-bottom: 1px solid var(--border-color);\n            padding: 15px 0;\n            position: sticky;\n            top: 0;\n            z-index: 100;\n        }\n\n        .header-content {\n            display: flex;\n            justify-content: space-between;\n            align-items: center;\n            flex-wrap: wrap;\n            gap: 14px;\n        }\n\n        .company-brand {\n            display: flex;\n            flex-direction: column;\n        }\n\n        .company-name {\n            font-size: 1.1rem;\n            font-weight: 700;\n            color: var(--accent-blue);\n            letter-spacing: 0.2px;\n        }\n\n        .company-name-cn {\n            font-size: 0.8rem;\n            color: var(--text-secondary);\n            margin-top: 2px;\n        }\n\n        .contact-bar {\n            display: flex;\n            gap: 10px;\n            flex-wrap: wrap;\n            align-items: center;\n        }\n\n        .contact-item {\n            display: flex;\n            align-items: center;\n            gap: 6px;\n            color: var(--text-secondary);\n            text-decoration: none;\n            font-size: 0.78rem;\n            padding: 6px 12px;\n            background: var(--bg-tertiary);\n            border-radius: 6px;\n            border: 1px solid var(--border-color);\n        }\n\n        .contact-item:hover {\n            color: var(--accent-green);\n            border-color: var(--accent-green);\n            background: rgba(80, 200, 120, 0.08);\n        }\n\n        .contact-icon {\n            width: 14px;\n            height: 14px;\n        }\n\n        \/* Hero Section *\/\n        .hero {\n            background: linear-gradient(155deg, var(--bg-secondary) 0%, var(--bg-tertiary) 100%);\n            border-bottom: 1px solid var(--border-color);\n            padding: 48px 0;\n        }\n\n        .hero-badge {\n            display: inline-flex;\n            align-items: center;\n            gap: 8px;\n            background: linear-gradient(135deg, var(--accent-orange), var(--accent-red));\n            color: #1a1a1a;\n            font-size: 0.64rem;\n            font-weight: 700;\n            padding: 5px 13px;\n            border-radius: 20px;\n            text-transform: uppercase;\n            letter-spacing: 1.2px;\n            margin-bottom: 15px;\n        }\n\n        .hero h1 {\n            font-size: 2.1rem;\n            font-weight: 700;\n            line-height: 1.25;\n            margin-bottom: 8px;\n            color: var(--text-primary);\n        }\n\n        .hero h1 .highlight {\n            color: var(--accent-blue);\n        }\n\n        .hero h1 .conductor-badge {\n            display: inline-block;\n            background: linear-gradient(135deg, var(--accent-orange), var(--accent-yellow));\n            color: #0a0d12;\n            font-size: 0.5em;\n            padding: 5px 13px;\n            border-radius: 6px;\n            vertical-align: middle;\n            margin-left: 11px;\n            font-weight: 700;\n        }\n\n        .hero-subtitle {\n            font-size: 1.25rem;\n            color: var(--text-secondary);\n            margin-bottom: 6px;\n        }\n\n        .hero-subtitle-cn {\n            font-size: 1.1rem;\n            color: var(--text-muted);\n            margin-bottom: 22px;\n        }\n\n        .hero-specs {\n            display: flex;\n            flex-wrap: wrap;\n            gap: 10px;\n            margin-top: 22px;\n        }\n\n        .spec-badge {\n            display: flex;\n            align-items: center;\n            gap: 7px;\n            background: var(--bg-card);\n            border: 1px solid var(--border-color);\n            padding: 9px 14px;\n            border-radius: 8px;\n            font-size: 0.84rem;\n        }\n\n        .spec-badge .value {\n            color: var(--accent-green);\n            font-weight: 600;\n            font-family: var(--font-mono);\n        }\n\n        .spec-badge .unit {\n            color: var(--text-secondary);\n        }\n\n        \/* Main Content *\/\n        main {\n            padding: 52px 0;\n        }\n\n        section {\n            margin-bottom: 56px;\n        }\n\n        .section-header {\n            margin-bottom: 22px;\n            padding-bottom: 14px;\n            border-bottom: 2px solid var(--border-color);\n            position: relative;\n        }\n\n        .section-header::after {\n            content: '';\n            position: absolute;\n            bottom: -2px;\n            left: 0;\n            width: 60px;\n            height: 2px;\n            background: linear-gradient(90deg, var(--accent-orange), var(--accent-yellow));\n        }\n\n        .section-header h2 {\n            font-size: 1.45rem;\n            font-weight: 700;\n            color: var(--text-primary);\n            margin-bottom: 5px;\n            display: flex;\n            align-items: center;\n            gap: 9px;\n        }\n\n        .section-header h2 .icon {\n            font-size: 1.05rem;\n        }\n\n        .section-header .subtitle {\n            color: var(--text-secondary);\n            font-size: 0.88rem;\n        }\n\n        \/* Bilingual Content *\/\n        .bilingual-block {\n            display: grid;\n            grid-template-columns: 1fr 1fr;\n            gap: 15px;\n            margin-bottom: 28px;\n        }\n\n        @media (max-width: 920px) {\n            .bilingual-block {\n                grid-template-columns: 1fr;\n            }\n        }\n\n        .lang-en, .lang-zh {\n            padding: 19px;\n            border-radius: 10px;\n        }\n\n        .lang-en {\n            background: var(--bg-secondary);\n            border-left: 4px solid var(--accent-blue);\n        }\n\n        .lang-zh {\n            background: var(--bg-card);\n            border-left: 4px solid var(--accent-orange);\n        }\n\n        .lang-label {\n            display: inline-flex;\n            align-items: center;\n            gap: 5px;\n            font-size: 0.58rem;\n            font-weight: 700;\n            text-transform: uppercase;\n            letter-spacing: 1.5px;\n            padding: 3px 8px;\n            border-radius: 4px;\n            margin-bottom: 10px;\n        }\n\n        .lang-en .lang-label {\n            background: rgba(93, 173, 236, 0.15);\n            color: var(--accent-blue);\n        }\n\n        .lang-zh .lang-label {\n            background: rgba(255, 159, 67, 0.15);\n            color: var(--accent-orange);\n        }\n\n        .bilingual-block p, .lang-en p, .lang-zh p {\n            font-size: 0.94rem;\n            line-height: 1.85;\n            color: var(--text-primary);\n        }\n\n        \/* Info Cards *\/\n        .info-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n            gap: 15px;\n            margin-top: 22px;\n        }\n\n        .info-card {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            border-radius: 11px;\n            padding: 20px;\n            position: relative;\n            overflow: hidden;\n        }\n\n        .info-card::before {\n            content: '';\n            position: absolute;\n            top: 0;\n            left: 0;\n            right: 0;\n            height: 3px;\n            background: linear-gradient(90deg, var(--accent-orange), var(--accent-green));\n        }\n\n        .info-card h3 {\n            font-size: 0.95rem;\n            font-weight: 600;\n            color: var(--accent-orange);\n            margin-bottom: 13px;\n            display: flex;\n            align-items: center;\n            gap: 8px;\n        }\n\n        .info-card ul {\n            list-style: none;\n        }\n\n        .info-card li {\n            padding: 7px 0;\n            border-bottom: 1px solid var(--border-subtle);\n            color: var(--text-secondary);\n            font-size: 0.86rem;\n            display: flex;\n            align-items: flex-start;\n            gap: 8px;\n        }\n\n        .info-card li::before {\n            content: '\u25b8';\n            color: var(--accent-green);\n            font-size: 0.7rem;\n            margin-top: 3px;\n        }\n\n        .info-card li:last-child {\n            border-bottom: none;\n        }\n\n        .info-card li strong {\n            color: var(--text-primary);\n        }\n\n        \/* Data Tables *\/\n        .table-wrapper {\n            width: 100%;\n            overflow-x: auto;\n            margin: 22px 0;\n            border: 1px solid var(--border-color);\n            border-radius: 11px;\n            background: var(--bg-secondary);\n        }\n\n        .table-title {\n            padding: 14px 17px;\n            background: var(--bg-tertiary);\n            border-bottom: 1px solid var(--border-color);\n            font-weight: 600;\n            color: var(--text-primary);\n            font-size: 0.92rem;\n            display: flex;\n            align-items: center;\n            gap: 9px;\n        }\n\n        .table-title .icon {\n            font-size: 0.98rem;\n        }\n\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            font-size: 0.74rem;\n            font-family: var(--font-mono);\n        }\n\n        thead {\n            background: var(--bg-tertiary);\n        }\n\n        th {\n            padding: 10px 12px;\n            text-align: left;\n            font-weight: 600;\n            color: var(--text-primary);\n            border-bottom: 2px solid var(--border-color);\n            white-space: nowrap;\n            font-size: 0.7rem;\n        }\n\n        th .unit {\n            display: block;\n            font-weight: 400;\n            color: var(--text-muted);\n            font-size: 0.62rem;\n            margin-top: 2px;\n        }\n\n        td {\n            padding: 8px 12px;\n            border-bottom: 1px solid var(--border-subtle);\n            color: var(--text-secondary);\n        }\n\n        tr:hover td {\n            background: rgba(93, 173, 236, 0.04);\n        }\n\n        .highlight-cell {\n            color: var(--accent-green);\n            font-weight: 600;\n        }\n\n        .size-cell {\n            color: var(--accent-blue);\n            font-weight: 500;\n        }\n\n        \/* Certifications *\/\n        .cert-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(155px, 1fr));\n            gap: 12px;\n            margin: 22px 0;\n        }\n\n        .cert-item {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            border-radius: 10px;\n            padding: 17px 13px;\n            text-align: center;\n        }\n\n        .cert-item:hover {\n            border-color: var(--accent-orange);\n        }\n\n        .cert-item .cert-icon {\n            font-size: 1.8rem;\n            margin-bottom: 8px;\n        }\n\n        .cert-item .cert-name {\n            font-weight: 600;\n            color: var(--text-primary);\n            font-size: 0.83rem;\n            margin-bottom: 3px;\n        }\n\n        .cert-item .cert-desc {\n            font-size: 0.68rem;\n            color: var(--text-muted);\n        }\n\n        \/* References *\/\n        .references {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            border-radius: 11px;\n            padding: 22px;\n            margin-top: 28px;\n        }\n\n        .references h3 {\n            font-size: 1rem;\n            font-weight: 600;\n            color: var(--text-primary);\n            margin-bottom: 16px;\n            display: flex;\n            align-items: center;\n            gap: 8px;\n        }\n\n        .ref-list {\n            list-style: none;\n        }\n\n        .ref-list li {\n            padding: 10px 0;\n            border-bottom: 1px solid var(--border-subtle);\n            display: flex;\n            flex-wrap: wrap;\n            gap: 8px;\n            align-items: baseline;\n        }\n\n        .ref-list li:last-child {\n            border-bottom: none;\n        }\n\n        .ref-number {\n            display: inline-flex;\n            align-items: center;\n            justify-content: center;\n            min-width: 22px;\n            height: 22px;\n            background: var(--accent-orange);\n            color: #0a0d12;\n            font-size: 0.66rem;\n            font-weight: 700;\n            border-radius: 50%;\n            flex-shrink: 0;\n        }\n\n        .ref-text {\n            color: var(--text-secondary);\n            font-size: 0.82rem;\n            flex: 1;\n            min-width: 180px;\n        }\n\n        .ref-text strong {\n            color: var(--text-primary);\n        }\n\n        .ref-link {\n            color: var(--accent-blue);\n            text-decoration: none;\n            font-size: 0.76rem;\n            word-break: break-all;\n        }\n\n        .ref-link:hover {\n            color: var(--accent-cyan);\n            text-decoration: underline;\n        }\n\n        \/* Comparison Note *\/\n        .comparison-note {\n            background: rgba(255, 159, 67, 0.08);\n            border: 1px solid rgba(255, 159, 67, 0.25);\n            border-radius: 8px;\n            padding: 14px 17px;\n            margin: 18px 0;\n            font-size: 0.84rem;\n            color: var(--text-secondary);\n            line-height: 1.7;\n        }\n\n        .comparison-note strong {\n            color: var(--accent-orange);\n        }\n\n        \/* Construction Section *\/\n        .construction-section {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            border-radius: 11px;\n            padding: 22px;\n            margin: 22px 0;\n        }\n\n        .construction-layers {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(160px, 1fr));\n            gap: 12px;\n            margin-top: 15px;\n        }\n\n        .layer-item {\n            background: var(--bg-tertiary);\n            border-radius: 8px;\n            padding: 14px;\n            text-align: center;\n            border: 1px solid var(--border-subtle);\n        }\n\n        .layer-number {\n            display: inline-flex;\n            align-items: center;\n            justify-content: center;\n            width: 26px;\n            height: 26px;\n            background: var(--accent-purple);\n            color: #fff;\n            font-size: 0.75rem;\n            font-weight: 700;\n            border-radius: 50%;\n            margin-bottom: 8px;\n        }\n\n        .layer-name {\n            font-weight: 600;\n            color: var(--text-primary);\n            font-size: 0.82rem;\n            margin-bottom: 4px;\n        }\n\n        .layer-name-cn {\n            color: var(--text-muted);\n            font-size: 0.72rem;\n            margin-bottom: 6px;\n        }\n\n        .layer-desc {\n            font-size: 0.7rem;\n            color: var(--text-secondary);\n            line-height: 1.5;\n        }\n\n        \/* Color Code Section *\/\n        .color-code-box {\n            background: var(--bg-tertiary);\n            border: 1px solid var(--border-color);\n            border-radius: 10px;\n            padding: 17px;\n            margin: 20px 0;\n            display: flex;\n            align-items: center;\n            gap: 15px;\n            flex-wrap: wrap;\n        }\n\n        .color-sample {\n            display: flex;\n            gap: 6px;\n            align-items: center;\n        }\n\n        .color-dot {\n            width: 24px;\n            height: 24px;\n            border-radius: 50%;\n            border: 2px solid var(--border-color);\n        }\n\n        .color-dot.black { background: #1a1a1a; }\n        .color-dot.white { background: #f5f5f5; }\n        .color-dot.red { background: #ef4444; }\n        .color-dot.green { background: #22c55e; }\n        .color-dot.orange { background: #f97316; }\n\n        .color-label {\n            font-size: 0.78rem;\n            color: var(--text-secondary);\n        }\n\n        \/* Applications *\/\n        .applications-grid {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(250px, 1fr));\n            gap: 14px;\n            margin: 22px 0;\n        }\n\n        .app-card {\n            background: var(--bg-secondary);\n            border: 1px solid var(--border-color);\n            border-radius: 10px;\n            padding: 17px;\n            display: flex;\n            gap: 12px;\n        }\n\n        .app-card:hover {\n            border-color: var(--accent-green);\n        }\n\n        .app-icon {\n            font-size: 1.6rem;\n            flex-shrink: 0;\n        }\n\n        .app-content h4 {\n            font-size: 0.9rem;\n            font-weight: 600;\n            color: var(--text-primary);\n            margin-bottom: 4px;\n        }\n\n        .app-content p {\n            font-size: 0.8rem;\n            color: var(--text-secondary);\n            line-height: 1.5;\n        }\n\n        \/* Ordering *\/\n        .ordering-example {\n            background: var(--bg-tertiary);\n            border-radius: 10px;\n            padding: 18px;\n            margin-top: 15px;\n            font-family: var(--font-mono);\n        }\n\n        .ordering-example .prefix { color: var(--accent-green); font-weight: 600; }\n        .ordering-example .part-no { color: var(--accent-blue); font-weight: 600; }\n        .ordering-example .armor { color: var(--accent-orange); font-weight: 600; }\n\n        \/* Footer *\/\n        footer {\n            background: var(--bg-secondary);\n            border-top: 1px solid var(--border-color);\n            padding: 40px 0 22px;\n        }\n\n        .footer-content {\n            display: grid;\n            grid-template-columns: repeat(auto-fit, minmax(230px, 1fr));\n            gap: 28px;\n            margin-bottom: 28px;\n        }\n\n        .footer-section h4 {\n            font-size: 0.92rem;\n            font-weight: 600;\n            color: var(--text-primary);\n            margin-bottom: 13px;\n        }\n\n        .footer-section p {\n            color: var(--text-secondary);\n            font-size: 0.82rem;\n            line-height: 1.7;\n        }\n\n        .footer-contact {\n            list-style: none;\n        }\n\n        .footer-contact li {\n            margin-bottom: 8px;\n        }\n\n        .footer-contact a {\n            color: var(--text-secondary);\n            text-decoration: none;\n            font-size: 0.82rem;\n            display: flex;\n            align-items: center;\n            gap: 7px;\n        }\n\n        .footer-contact a:hover {\n            color: var(--accent-blue);\n        }\n\n        .whatsapp-btn {\n            display: inline-flex;\n            align-items: center;\n            gap: 7px;\n            background: #25D366;\n            color: #fff;\n            padding: 9px 16px;\n            border-radius: 7px;\n            text-decoration: none;\n            font-weight: 600;\n            font-size: 0.85rem;\n            margin-top: 11px;\n        }\n\n        .whatsapp-btn:hover {\n            background: #128C7E;\n        }\n\n        .footer-bottom {\n            text-align: center;\n            padding-top: 22px;\n            border-top: 1px solid var(--border-color);\n            color: var(--text-muted);\n            font-size: 0.76rem;\n        }\n\n        \/* Responsive *\/\n        @media (max-width: 768px) {\n            .hero h1 {\n                font-size: 1.5rem;\n            }\n\n            .hero h1 .conductor-badge {\n                display: block;\n                margin-left: 0;\n                margin-top: 9px;\n                width: fit-content;\n            }\n\n            .hero-subtitle {\n                font-size: 1rem;\n            }\n\n            .section-header h2 {\n                font-size: 1.2rem;\n            }\n\n            table {\n                font-size: 0.64rem;\n            }\n\n            th, td {\n                padding: 6px 8px;\n            }\n\n            .container {\n                padding: 0 12px;\n            }\n\n            .info-grid {\n                grid-template-columns: 1fr;\n            }\n        }\n\n        @media print {\n            body { background: #fff; color: #000; }\n            header, footer { display: none; }\n        }\n    <\/style>\n<\/head>\n<body>\n    <!-- Header -->\n    <header>\n        <div class=\"container\">\n            <div class=\"header-content\">\n                <div class=\"company-brand\">\n                    <span class=\"company-name\">Anhui Feichun Special Cable Co., Ltd.<\/span>\n                    <span class=\"company-name-cn\">\u5b89\u5fbd\u98db\u7d14\u7279\u7a2e\u96fb\u7e9c\u6709\u9650\u516c\u53f8<\/span>\n                <\/div>\n                <div class=\"contact-bar\">\n                    <a href=\"https:\/\/wa.me\/8613855123218\" class=\"contact-item\" rel=\"nofollow noopener\" target=\"_blank\">\n                        <svg class=\"contact-icon\" viewBox=\"0 0 24 24\" fill=\"currentColor\"><path d=\"M17.472 14.382c-.297-.149-1.758-.867-2.03-.967-.273-.099-.471-.148-.67.15-.197.297-.767.966-.94 1.164-.173.199-.347.223-.644.075-.297-.15-1.255-.463-2.39-1.475-.883-.788-1.48-1.761-1.653-2.059-.173-.297-.018-.458.13-.606.134-.133.298-.347.446-.52.149-.174.198-.298.298-.497.099-.198.05-.371-.025-.52-.075-.149-.669-1.612-.916-2.207-.242-.579-.487-.5-.669-.51-.173-.008-.371-.01-.57-.01-.198 0-.52.074-.792.372-.272.297-1.04 1.016-1.04 2.479 0 1.462 1.065 2.875 1.213 3.074.149.198 2.096 3.2 5.077 4.487.709.306 1.262.489 1.694.625.712.227 1.36.195 1.871.118.571-.085 1.758-.719 2.006-1.413.248-.694.248-1.289.173-1.413-.074-.124-.272-.198-.57-.347m-5.421 7.403h-.004a9.87 9.87 0 01-5.031-1.378l-.361-.214-3.741.982.998-3.648-.235-.374a9.86 9.86 0 01-1.51-5.26c.001-5.45 4.436-9.884 9.888-9.884 2.64 0 5.122 1.03 6.988 2.898a9.825 9.825 0 012.893 6.994c-.003 5.45-4.437 9.884-9.885 9.884m8.413-18.297A11.815 11.815 0 0012.05 0C5.495 0 .16 5.335.157 11.892c0 2.096.547 4.142 1.588 5.945L.057 24l6.305-1.654a11.882 11.882 0 005.683 1.448h.005c6.554 0 11.89-5.335 11.893-11.893a11.821 11.821 0 00-3.48-8.413z\"\/><\/svg>\n                        WhatsApp\n                    <\/a>\n                    <a href=\"mailto:tech@feichuncables.com\" class=\"contact-item\" rel=\"nofollow\">\n                        <svg class=\"contact-icon\" viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"><path d=\"M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z\"\/><polyline points=\"22,6 12,13 2,6\"\/><\/svg>\n                        Tech Support\n                    <\/a>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/header>\n\n    <!-- Hero Section -->\n    <section class=\"hero\">\n        <div class=\"container\">\n            <span class=\"hero-badge\">\ud83d\udd25 Fire Resistant Cable \u8010\u706b\u96fb\u7e9c<\/span>\n            <h1>GEXOL\u00ae-331HF <span class=\"highlight\">Power Cable<\/span><span class=\"conductor-badge\">5 CONDUCTOR \u4e94\u82af<\/span><\/h1>\n            <p class=\"hero-subtitle\">Low Smoke Halogen-Free \u2022 Extremely Flexible \u2022 0.6\/1kV \u2022 Rated 90\u00b0C<\/p>\n            <p class=\"hero-subtitle-cn\">\u4f4e\u7159\u7121\u9e75 \u2022 \u6975\u5ea6\u67d4\u8edf \u2022 0.6\/1kV\u984d\u5b9a\u96fb\u58d3 \u2022 90\u00b0C\u984d\u5b9a\u6eab\u5ea6<\/p>\n            \n            <div class=\"hero-specs\">\n                <div class=\"spec-badge\">\n                    <span class=\"value\">0.6\/1kV<\/span>\n                    <span class=\"unit\">Voltage<\/span>\n                <\/div>\n                <div class=\"spec-badge\">\n                    <span class=\"value\">90\u00b0C<\/span>\n                    <span class=\"unit\">Temp. Rating<\/span>\n                <\/div>\n                <div class=\"spec-badge\">\n                    <span class=\"value\">-40\u00b0C<\/span>\n                    <span class=\"unit\">Cold Bend<\/span>\n                <\/div>\n                <div class=\"spec-badge\">\n                    <span class=\"value\">IEC 60331<\/span>\n                    <span class=\"unit\">Fire Resistant<\/span>\n                <\/div>\n                <div class=\"spec-badge\">\n                    <span class=\"value\">IEEE 1580<\/span>\n                    <span class=\"unit\">Compliant<\/span>\n                <\/div>\n                <div class=\"spec-badge\">\n                    <span class=\"value\">5-Core<\/span>\n                    <span class=\"unit\">Configuration<\/span>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/section>\n\n    <!-- Main Content -->\n    <main>\n        <div class=\"container\">\n            \n            <!-- Product Overview -->\n            <section id=\"overview\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\ud83d\udccb<\/span> Product Overview \u7522\u54c1\u6982\u8ff0<\/h2>\n                    <p class=\"subtitle\">Complete introduction to GEXOL\u00ae-331HF Five Conductor cable specifications<\/p>\n                <\/div>\n\n                <div class=\"bilingual-block\">\n                    <div class=\"lang-en\">\n                        <span class=\"lang-label\">\ud83c\uddec\ud83c\udde7 English<\/span>\n                        <p>The <strong>GEXOL\u00ae-331HF Five Conductor Power Cable<\/strong> represents the most comprehensive multi-conductor solution in the GEXOL fire-resistant cable family, engineered specifically for complex five-phase power applications and advanced electrical systems in demanding offshore and marine environments worldwide. This five-conductor design maintains circuit integrity during fire conditions while providing maximum flexibility for sophisticated power distribution requirements. The cable features a Black-White-Red-Green-Orange color coding system for easy phase identification, with sizes 1\/0 AWG and larger utilizing printed phase identification on the insulation. Available in 13 conductor sizes from 18 AWG to 4\/0 AWG, this cable delivers complete five-conductor power solutions for emergency lighting, fire detection\/suppression systems, alarm networks, and critical process control applications.<\/p>\n                    <\/div>\n                    <div class=\"lang-zh\">\n                        <span class=\"lang-label\">\ud83c\uddf9\ud83c\uddfc \u7e41\u9ad4\u4e2d\u6587<\/span>\n                        <p><strong>GEXOL\u00ae-331HF \u4e94\u82af\u96fb\u529b\u96fb\u7e9c<\/strong>\u662f GEXOL \u8010\u706b\u96fb\u7e9c\u7cfb\u5217\u4e2d\u6700\u5168\u9762\u7684\u591a\u5c0e\u9ad4\u89e3\u6c7a\u65b9\u6848\uff0c\u5c08\u70ba\u5168\u7403\u56b4\u82db\u7684\u6d77\u6d0b\u548c\u96e2\u5cb8\u74b0\u5883\u4e2d\u7684\u8907\u96dc\u4e94\u76f8\u96fb\u529b\u61c9\u7528\u548c\u5148\u9032\u96fb\u6c23\u7cfb\u7d71\u800c\u8a2d\u8a08\u3002\u9019\u7a2e\u4e94\u5c0e\u9ad4\u8a2d\u8a08\u53ef\u5728\u706b\u707d\u689d\u4ef6\u4e0b\u4fdd\u6301\u96fb\u8def\u5b8c\u6574\u6027\uff0c\u540c\u6642\u70ba\u8907\u96dc\u7684\u96fb\u529b\u914d\u96fb\u9700\u6c42\u63d0\u4f9b\u6700\u5927\u7684\u9748\u6d3b\u6027\u3002\u8a72\u96fb\u7e9c\u63a1\u7528\u9ed1\u767d\u7d05\u7da0\u6a59\u8272\u78bc\u7cfb\u7d71\u4fbf\u65bc\u76f8\u4f4d\u8b58\u5225\uff0c1\/0 AWG \u53ca\u4ee5\u4e0a\u898f\u683c\u5728\u7d55\u7de3\u5c64\u4e0a\u63a1\u7528\u5370\u5237\u76f8\u4f4d\u6a19\u8b58\u3002\u63d0\u4f9b\u5f9e 18 AWG \u5230 4\/0 AWG \u7684 13 \u7a2e\u5c0e\u9ad4\u898f\u683c\uff0c\u8a72\u96fb\u7e9c\u53ef\u70ba\u7dca\u6025\u7167\u660e\u3001\u706b\u707d\u5075\u6e2c\/\u6ec5\u706b\u7cfb\u7d71\u3001\u8b66\u5831\u7db2\u8def\u548c\u95dc\u9375\u904e\u7a0b\u63a7\u5236\u61c9\u7528\u63d0\u4f9b\u5b8c\u6574\u7684\u4e94\u82af\u96fb\u529b\u89e3\u6c7a\u65b9\u6848\u3002<\/p>\n                    <\/div>\n                <\/div>\n\n                <!-- Color Code Display -->\n                <div class=\"color-code-box\">\n                    <div style=\"font-weight: 600; color: var(--text-primary); margin-right: 6px;\">Phase Color Code \u76f8\u4f4d\u8272\u78bc\uff1a<\/div>\n                    <div class=\"color-sample\">\n                        <div class=\"color-dot black\"><\/div>\n                        <span class=\"color-label\">Phase 1 (Black \u9ed1)<\/span>\n                    <\/div>\n                    <div class=\"color-sample\">\n                        <div class=\"color-dot white\"><\/div>\n                        <span class=\"color-label\">Phase 2 (White \u767d)<\/span>\n                    <\/div>\n                    <div class=\"color-sample\">\n                        <div class=\"color-dot red\"><\/div>\n                        <span class=\"color-label\">Phase 3 (Red \u7d05)<\/span>\n                    <\/div>\n                    <div class=\"color-sample\">\n                        <div class=\"color-dot green\"><\/div>\n                        <span class=\"color-label\">Phase 4 (Green \u7da0)<\/span>\n                    <\/div>\n                    <div class=\"color-sample\">\n                        <div class=\"color-dot orange\"><\/div>\n                        <span class=\"color-label\">Phase 5 (Orange \u6a59)<\/span>\n                    <\/div>\n                <\/div>\n            <\/section>\n\n            <!-- Ratings & Approvals -->\n            <section id=\"certifications\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\u2705<\/span> Ratings &amp; Approvals \u8a8d\u8b49\u8207\u6279\u51c6<\/h2>\n                    <p class=\"subtitle\">International certifications ensuring global compliance and reliability<\/p>\n                <\/div>\n\n                <div class=\"cert-grid\">\n                    <div class=\"cert-item\">\n                        <div class=\"cert-icon\">\ud83c\udf21\ufe0f<\/div>\n                        <div class=\"cert-name\">90\u00b0C Rating<\/div>\n                        <div class=\"cert-desc\">\u984d\u5b9a\u6eab\u5ea6\u7b49\u7d1a<\/div>\n                    <\/div>\n                    <div class=\"cert-item\">\n                        <div class=\"cert-icon\">\u2693<\/div>\n                        <div class=\"cert-name\">ABS<\/div>\n                        <div class=\"cert-desc\">\u7f8e\u570b\u8239\u7d1a\u793e<\/div>\n                    <\/div>\n                    <div class=\"cert-item\">\n                        <div class=\"cert-icon\">\ud83d\udccb<\/div>\n                        <div class=\"cert-name\">NRTL IEEE 1580<\/div>\n                        <div class=\"cert-desc\">\u570b\u5bb6\u8a8d\u53ef\u6e2c\u8a66\u5be6\u9a57\u5ba4<\/div>\n                    <\/div>\n                    <div class=\"cert-item\">\n                        <div class=\"cert-icon\">\ud83c\udf41<\/div>\n                        <div class=\"cert-name\">Transport Canada<\/div>\n                        <div class=\"cert-desc\">\u52a0\u62ff\u5927\u904b\u8f38\u90e8<\/div>\n                    <\/div>\n                    <div class=\"cert-item\">\n                        <div class=\"cert-icon\">\ud83d\udd12<\/div>\n                        <div class=\"cert-name\">DNV-GL<\/div>\n                        <div class=\"cert-desc\">\u632a\u5a01\u8239\u7d1a\u793e<\/div>\n                    <\/div>\n                    <div class=\"cert-item\">\n                        <div class=\"cert-icon\">\ud83d\udea2<\/div>\n                        <div class=\"cert-name\">Lloyd&#8217;s Register<\/div>\n                        <div class=\"cert-desc\">\u52de\u6c0f\u8239\u7d1a\u793e (LRS)<\/div>\n                    <\/div>\n                <\/div>\n\n                <div class=\"comparison-note\">\n                    <strong>Standards Compliance \u6a19\u6e96\u5408\u898f\u6027\uff1a<\/strong> All GEXOL\u00ae-331HF Five Conductor cables are manufactured in accordance with IEEE 1580 &#8220;Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Offshore Facilities&#8221; and meet IEC 60092-350 series requirements. The five-conductor configuration provides maximum flexibility for complex marine and offshore electrical systems requiring multiple power and control conductors in a single cable assembly.<br><br>\n                    \u6240\u6709 GEXOL\u00ae-331HF \u4e94\u82af\u96fb\u7e9c\u5747\u6309\u7167 IEEE 1580\u300a\u8239\u8236\u53ca\u56fa\u5b9a\u6216\u6d6e\u52d5\u96e2\u5cb8\u8a2d\u65bd\u7528\u8239\u7528\u96fb\u7e9c\u63a8\u85a6\u898f\u7bc4\u300b\u88fd\u9020\uff0c\u4e26\u7b26\u5408 IEC 60092-350 \u7cfb\u5217\u8981\u6c42\u3002\u4e94\u5c0e\u9ad4\u914d\u7f6e\u70ba\u9700\u8981\u5728\u55ae\u4e00\u96fb\u7e9c\u7d44\u4ef6\u4e2d\u4f7f\u7528\u591a\u500b\u96fb\u529b\u548c\u63a7\u5236\u5c0e\u9ad4\u7684\u8907\u96dc\u6d77\u6d0b\u548c\u96e2\u5cb8\u96fb\u6c23\u7cfb\u7d71\u63d0\u4f9b\u6700\u5927\u7684\u9748\u6d3b\u6027\u3002\n                <\/div>\n            <\/section>\n\n            <!-- Cable Construction -->\n            <section id=\"construction\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\ud83d\udd27<\/span> Cable Construction \u96fb\u7e9c\u7d50\u69cb<\/h2>\n                    <p class=\"subtitle\">Layer-by-layer breakdown of cable materials and specifications<\/p>\n                <\/div>\n\n                <div class=\"construction-section\">\n                    <h3 style=\"color: var(--text-primary); margin-bottom: 5px;\">Component Layers \u7d44\u4ef6\u5c64\u6b21<\/h3>\n                    <p style=\"color: var(--text-secondary); font-size: 0.84rem; margin-bottom: 14px;\">Each layer engineered to meet IEEE 1580 and IEC standards. \u6bcf\u5c64\u5747\u6309\u7167 IEEE 1580 \u548c IEC \u6a19\u6e96\u8a2d\u8a08\u3002<\/p>\n                    \n                    <div class=\"construction-layers\">\n                        <div class=\"layer-item\">\n                            <div class=\"layer-number\">1<\/div>\n                            <div class=\"layer-name\">Conductors<\/div>\n                            <div class=\"layer-name-cn\">\u5c0e\u9ad4<\/div>\n                            <div class=\"layer-desc\">Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11<br>\u8edf\u9000\u706b\u67d4\u6027\u7d5e\u5408\u934d\u932b\u9285<\/div>\n                        <\/div>\n                        <div class=\"layer-item\">\n                            <div class=\"layer-number\">2<\/div>\n                            <div class=\"layer-name\">Insulation<\/div>\n                            <div class=\"layer-name-cn\">\u7d55\u7de3\u5c64<\/div>\n                            <div class=\"layer-desc\">Fire resistant tape + GEXOL\u00ae-HF XLPO (LSE\/LSX) Black-White-Red-Green-Orange<br>\u8010\u706b\u5e36 + \u4ea4\u806f\u805a\u70ef\u70f4<\/div>\n                        <\/div>\n                        <div class=\"layer-item\">\n                            <div class=\"layer-number\">3<\/div>\n                            <div class=\"layer-name\">Jacket<\/div>\n                            <div class=\"layer-name-cn\">\u8b77\u5957<\/div>\n                            <div class=\"layer-desc\">Black LSZH flame retardant polyolefin per IEEE 1580<br>\u9ed1\u8272\u4f4e\u7159\u7121\u9e75\u963b\u71c3\u805a\u70ef\u70f4<\/div>\n                        <\/div>\n                        <div class=\"layer-item\">\n                            <div class=\"layer-number\">4<\/div>\n                            <div class=\"layer-name\">Armor (Optional)<\/div>\n                            <div class=\"layer-name-cn\">\u93a7\u88dd\uff08\u53ef\u9078\uff09<\/div>\n                            <div class=\"layer-desc\">Basket weave wire armor per IEEE 1580 &amp; UL 1309\/CSA 245<br>\u7de8\u7e54\u7d72\u93a7\u88dd<\/div>\n                        <\/div>\n                        <div class=\"layer-item\">\n                            <div class=\"layer-number\">5<\/div>\n                            <div class=\"layer-name\">Sheath (Optional)<\/div>\n                            <div class=\"layer-name-cn\">\u5916\u8b77\u5957\uff08\u53ef\u9078\uff09<\/div>\n                            <div class=\"layer-desc\">Black LSZH flame retardant polyolefin per IEEE 1580<br>\u9ed1\u8272\u4f4e\u7159\u7121\u9e75\u963b\u71c3\u805a\u70ef\u70f4<\/div>\n                        <\/div>\n                    <\/div>\n                <\/div>\n            <\/section>\n\n            <!-- Technical Features -->\n            <section id=\"features\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\u26a1<\/span> Technical Features \u6280\u8853\u7279\u9ede<\/h2>\n                    <p class=\"subtitle\">Key performance characteristics and material specifications<\/p>\n                <\/div>\n\n                <div class=\"info-grid\">\n                    <div class=\"info-card\">\n                        <h3>\ud83d\udd25 Fire Performance \u8010\u706b\u6027\u80fd<\/h3>\n                        <ul>\n                            <li><strong>Fire Resistant:<\/strong> IEC 60331 circuit integrity \u96fb\u8def\u5b8c\u6574\u6027<\/li>\n                            <li><strong>Flame Retardant:<\/strong> IEC 332-3 Category A \u963b\u71c3\u7b49\u7d1a<\/li>\n                            <li><strong>IEEE 1202:<\/strong> Vertical tray flame test \u5782\u76f4\u6258\u76e4\u71c3\u71d2\u6e2c\u8a66<\/li>\n                            <li><strong>Low Smoke:<\/strong> Minimal smoke generation \u6700\u5c0f\u7159\u9727\u7522\u751f<\/li>\n                            <li><strong>Halogen-Free:<\/strong> Zero halogen content \u96f6\u9e75\u7d20\u542b\u91cf<\/li>\n                        <\/ul>\n                    <\/div>\n                    <div class=\"info-card\">\n                        <h3>\u2744\ufe0f Mechanical Properties \u6a5f\u68b0\u6027\u80fd<\/h3>\n                        <ul>\n                            <li><strong>Flexibility:<\/strong> High strand count conductors \u9ad8\u80a1\u6578\u5c0e\u9ad4<\/li>\n                            <li><strong>Cold Bend:<\/strong> -40\u00b0C rating (CSA) \u4f4e\u6eab\u5f4e\u66f2\u6027\u80fd<\/li>\n                            <li><strong>Cold Impact:<\/strong> -35\u00b0C rating (CSA) \u4f4e\u6eab\u885d\u64ca\u6027\u80fd<\/li>\n                            <li><strong>Installation:<\/strong> Easier than IEC 60092-350 series \u5b89\u88dd\u66f4\u4fbf\u6377<\/li>\n                            <li><strong>Durability:<\/strong> Exceeds CSA cold requirements \u8d85\u8d8aCSA\u4f4e\u6eab\u8981\u6c42<\/li>\n                        <\/ul>\n                    <\/div>\n                    <div class=\"info-card\">\n                        <h3>\ud83d\udee1\ufe0f Armor Options \u93a7\u88dd\u9078\u9805<\/h3>\n                        <ul>\n                            <li><strong>Type:<\/strong> Basket weave wire armor \u7de8\u7e54\u7d72\u93a7\u88dd<\/li>\n                            <li><strong>Standard:<\/strong> IEEE 1580 &amp; UL 1309\/CSA 245 \u6a19\u6e96<\/li>\n                            <li><strong>Bronze:<\/strong> Standard configuration \u9752\u9285\uff08\u6a19\u6e96\u914d\u7f6e\uff09<\/li>\n                            <li><strong>Aluminum:<\/strong> Available by request \u92c1\uff08\u53ef\u9078\uff09<\/li>\n                            <li><strong>Tinned Copper:<\/strong> Available by request \u934d\u932b\u9285\uff08\u53ef\u9078\uff09<\/li>\n                        <\/ul>\n                    <\/div>\n                    <div class=\"info-card\">\n                        <h3>\u26a0\ufe0f Hazardous Locations \u5371\u96aa\u5340\u57df<\/h3>\n                        <ul>\n                            <li><strong>Class I, Division 1:<\/strong> Armored &amp; sheathed config. \u93a7\u88dd\u8b77\u5957\u914d\u7f6e<\/li>\n                            <li><strong>Class I, Zone 1:<\/strong> With armor and sheath \u914d\u5408\u93a7\u88dd\u548c\u8b77\u5957<\/li>\n                            <li><strong>Class I, Division 2:<\/strong> Suitable applications \u9069\u7528\u5834\u5408<\/li>\n                            <li><strong>Class I, Zone 2:<\/strong> Suitable applications \u9069\u7528\u5834\u5408<\/li>\n                            <li><strong>Explosion Proof:<\/strong> EExd rated configurations EExd\u7b49\u7d1a\u914d\u7f6e<\/li>\n                        <\/ul>\n                    <\/div>\n                    <div class=\"info-card\">\n                        <h3>\ud83d\udcd0 Five-Conductor Design \u4e94\u82af\u8a2d\u8a08<\/h3>\n                        <ul>\n                            <li><strong>Configuration:<\/strong> Five insulated conductors \u4e94\u6839\u7d55\u7de3\u5c0e\u9ad4<\/li>\n                            <li><strong>Color Code:<\/strong> Black-White-Red-Green-Orange \u9ed1\u767d\u7d05\u7da0\u6a59<\/li>\n                            <li><strong>Phase I.D.:<\/strong> Printed for 1\/0 AWG+ 1\/0 AWG\u4ee5\u4e0a\u5370\u5237\u6a19\u8b58<\/li>\n                            <li><strong>Voltage:<\/strong> 0.6\/1kV rated \u984d\u5b9a\u96fb\u58d3<\/li>\n                            <li><strong>Size Range:<\/strong> 18 AWG to 4\/0 AWG \u5c3a\u5bf8\u7bc4\u570d<\/li>\n                        <\/ul>\n                    <\/div>\n                    <div class=\"info-card\">\n                        <h3>\ud83d\udd0c Applications \u61c9\u7528\u5834\u666f<\/h3>\n                        <ul>\n                            <li><strong>3-Phase + N + PE:<\/strong> Complete power distribution \u5b8c\u6574\u96fb\u529b\u914d\u96fb<\/li>\n                            <li><strong>Control Circuits:<\/strong> Multi-conductor control \u591a\u5c0e\u9ad4\u63a7\u5236<\/li>\n                            <li><strong>VFD Systems:<\/strong> Variable frequency drives \u8b8a\u983b\u9a45\u52d5\u5668<\/li>\n                            <li><strong>Motor Feeds:<\/strong> Complex motor circuits \u8907\u96dc\u96fb\u6a5f\u96fb\u8def<\/li>\n                            <li><strong>Instrumentation:<\/strong> Multi-channel systems \u591a\u901a\u9053\u7cfb\u7d71<\/li>\n                        <\/ul>\n                    <\/div>\n                <\/div>\n            <\/section>\n\n            <!-- Applications -->\n            <section id=\"applications\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\ud83c\udfaf<\/span> Applications \u61c9\u7528\u9818\u57df<\/h2>\n                    <p class=\"subtitle\">Critical five-conductor power circuits in demanding environments<\/p>\n                <\/div>\n\n                <div class=\"bilingual-block\">\n                    <div class=\"lang-en\">\n                        <span class=\"lang-label\">\ud83c\uddec\ud83c\udde7 English<\/span>\n                        <p>GEXOL\u00ae-331HF Five Conductor cables are specifically designed for the demanding environments of offshore facilities located throughout the world. These cables are primarily used on critical five-conductor circuits that must continue to function even during fire conditions. The five-conductor configuration provides complete power solutions for complex electrical systems including three-phase with neutral and protective earth (3P+N+PE), specialized motor controls with feedback circuits, variable frequency drive systems, and sophisticated process control applications. This product should be deployed on any circuit dedicated to emergency lighting, fire detection and suppression systems, alarm networks, personnel egress pathways, and critical instrumentation requiring multiple conductors in a single cable assembly.<\/p>\n                    <\/div>\n                    <div class=\"lang-zh\">\n                        <span class=\"lang-label\">\ud83c\uddf9\ud83c\uddfc \u7e41\u9ad4\u4e2d\u6587<\/span>\n                        <p>GEXOL\u00ae-331HF \u4e94\u82af\u96fb\u7e9c\u5c08\u70ba\u5168\u7403\u96e2\u5cb8\u8a2d\u65bd\u7684\u56b4\u82db\u74b0\u5883\u8a2d\u8a08\u3002\u9019\u4e9b\u96fb\u7e9c\u4e3b\u8981\u7528\u65bc\u5fc5\u9808\u5728\u706b\u707d\u689d\u4ef6\u4e0b\u7e7c\u7e8c\u904b\u4f5c\u7684\u95dc\u9375\u4e94\u5c0e\u9ad4\u96fb\u8def\u3002\u4e94\u5c0e\u9ad4\u914d\u7f6e\u70ba\u8907\u96dc\u96fb\u6c23\u7cfb\u7d71\u63d0\u4f9b\u5b8c\u6574\u7684\u96fb\u529b\u89e3\u6c7a\u65b9\u6848\uff0c\u5305\u62ec\u5e36\u4e2d\u6027\u7dda\u548c\u4fdd\u8b77\u63a5\u5730\u7684\u4e09\u76f8\u7cfb\u7d71\uff083P+N+PE\uff09\u3001\u5e36\u53cd\u994b\u96fb\u8def\u7684\u5c08\u7528\u96fb\u6a5f\u63a7\u5236\u3001\u8b8a\u983b\u9a45\u52d5\u5668\u7cfb\u7d71\u548c\u7cbe\u5bc6\u904e\u7a0b\u63a7\u5236\u61c9\u7528\u3002\u8a72\u7522\u54c1\u61c9\u90e8\u7f72\u5728\u4efb\u4f55\u5c08\u7528\u65bc\u7dca\u6025\u7167\u660e\u3001\u706b\u707d\u5075\u6e2c\u548c\u6ec5\u706b\u7cfb\u7d71\u3001\u8b66\u5831\u7db2\u8def\u3001\u4eba\u54e1\u758f\u6563\u901a\u9053\u4ee5\u53ca\u9700\u8981\u5728\u55ae\u4e00\u96fb\u7e9c\u7d44\u4ef6\u4e2d\u4f7f\u7528\u591a\u500b\u5c0e\u9ad4\u7684\u95dc\u9375\u5100\u8868\u7684\u96fb\u8def\u4e0a\u3002<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"applications-grid\">\n                    <div class=\"app-card\">\n                        <div class=\"app-icon\">\ud83d\udca1<\/div>\n                        <div class=\"app-content\">\n                            <h4>Emergency Systems \u7dca\u6025\u7cfb\u7d71<\/h4>\n                            <p>Five-wire emergency lighting with control feedback.<br>\u5e36\u63a7\u5236\u53cd\u994b\u7684\u4e94\u7dda\u7dca\u6025\u7167\u660e\u3002<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"app-card\">\n                        <div class=\"app-icon\">\ud83d\udd25<\/div>\n                        <div class=\"app-content\">\n                            <h4>Fire Systems \u6d88\u9632\u7cfb\u7d71<\/h4>\n                            <p>Fire pumps with 3P+N+PE power configuration.<br>3P+N+PE\u96fb\u529b\u914d\u7f6e\u7684\u6d88\u9632\u6cf5\u3002<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"app-card\">\n                        <div class=\"app-icon\">\u2699\ufe0f<\/div>\n                        <div class=\"app-content\">\n                            <h4>VFD Motor Systems \u8b8a\u983b\u96fb\u6a5f\u7cfb\u7d71<\/h4>\n                            <p>Variable frequency drive motor circuits.<br>\u8b8a\u983b\u9a45\u52d5\u5668\u96fb\u6a5f\u96fb\u8def\u3002<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"app-card\">\n                        <div class=\"app-icon\">\ud83d\udcca<\/div>\n                        <div class=\"app-content\">\n                            <h4>Process Control \u904e\u7a0b\u63a7\u5236<\/h4>\n                            <p>Multi-channel instrumentation systems.<br>\u591a\u901a\u9053\u5100\u8868\u7cfb\u7d71\u3002<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"app-card\">\n                        <div class=\"app-icon\">\ud83d\udee2\ufe0f<\/div>\n                        <div class=\"app-content\">\n                            <h4>Offshore Platforms \u96e2\u5cb8\u5e73\u53f0<\/h4>\n                            <p>Oil &amp; gas complex power distribution.<br>\u77f3\u6cb9\u548c\u5929\u7136\u6c23\u8907\u96dc\u96fb\u529b\u914d\u96fb\u3002<\/p>\n                        <\/div>\n                    <\/div>\n                    <div class=\"app-card\">\n                        <div class=\"app-icon\">\ud83d\udea2<\/div>\n                        <div class=\"app-content\">\n                            <h4>Marine Vessels \u8239\u8236<\/h4>\n                            <p>Shipboard five-conductor systems meeting classification requirements.<br>\u7b26\u5408\u8239\u7d1a\u793e\u8981\u6c42\u7684\u8239\u8236\u4e94\u82af\u7cfb\u7d71\u3002<\/p>\n                        <\/div>\n                    <\/div>\n                <\/div>\n            <\/section>\n\n            <!-- Technical Specifications Table -->\n            <section id=\"specifications\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\ud83d\udcca<\/span> Technical Specifications \u6280\u8853\u898f\u683c<\/h2>\n                    <p class=\"subtitle\">Complete electrical and physical parameters for all 13 cable sizes<\/p>\n                <\/div>\n\n                <div class=\"table-wrapper\">\n                    <div class=\"table-title\"><span class=\"icon\">\ud83d\udcd0<\/span> GEXOL\u00ae-331HF Five Conductor Cable &#8211; Physical Dimensions \u7269\u7406\u5c3a\u5bf8<\/div>\n                    <table>\n                        <thead>\n                            <tr>\n                                <th>Size<span class=\"unit\">\u5c3a\u5bf8<\/span><\/th>\n                                <th>mm\u00b2<\/th>\n                                <th>Part No.<span class=\"unit\">\u96f6\u4ef6\u7de8\u865f<\/span><\/th>\n                                <th>Unarmored Dia.<span class=\"unit\">\u7121\u93a7\u88dd (in)<\/span><\/th>\n                                <th>Unarmored Wt.<span class=\"unit\">(lbs\/MFt)<\/span><\/th>\n                                <th>Armored (B) Dia.<span class=\"unit\">\u93a7\u88dd (in)<\/span><\/th>\n                                <th>Armored (B) Wt.<span class=\"unit\">(lbs\/MFt)<\/span><\/th>\n                                <th>Sheathed (BS) Dia.<span class=\"unit\">\u8b77\u5957 (in)<\/span><\/th>\n                                <th>Sheathed (BS) Wt.<span class=\"unit\">(lbs\/MFt)<\/span><\/th>\n                            <\/tr>\n                        <\/thead>\n                        <tbody>\n                            <tr><td class=\"size-cell\">18 AWG<\/td><td>1.0<\/td><td>37-104-558<\/td><td>0.523<\/td><td>139<\/td><td>0.573<\/td><td>223<\/td><td>0.731<\/td><td>319<\/td><\/tr>\n                            <tr><td class=\"size-cell\">16 AWG<\/td><td>1.3<\/td><td>37-104-559<\/td><td>0.536<\/td><td>152<\/td><td>0.587<\/td><td>236<\/td><td>0.760<\/td><td>335<\/td><\/tr>\n                            <tr><td class=\"size-cell\">14 AWG<\/td><td>2.1<\/td><td>37-104-510<\/td><td>0.593<\/td><td>200<\/td><td>0.643<\/td><td>294<\/td><td>0.774<\/td><td>398<\/td><\/tr>\n                            <tr><td class=\"size-cell\">12 AWG<\/td><td>3.3<\/td><td>37-104-560<\/td><td>0.650<\/td><td>253<\/td><td>0.700<\/td><td>354<\/td><td>0.887<\/td><td>498<\/td><\/tr>\n                            <tr><td class=\"size-cell\">10 AWG<\/td><td>5.2<\/td><td>37-104-561<\/td><td>0.704<\/td><td>336<\/td><td>0.754<\/td><td>448<\/td><td>0.954<\/td><td>610<\/td><\/tr>\n                            <tr><td class=\"size-cell\">8 AWG<\/td><td>7.6<\/td><td>37-104-562<\/td><td>0.891<\/td><td>523<\/td><td>0.941<\/td><td>666<\/td><td>1.141<\/td><td>863<\/td><\/tr>\n                            <tr><td class=\"size-cell\">6 AWG<\/td><td>12.5<\/td><td>37-104-563<\/td><td>0.990<\/td><td>730<\/td><td>1.040<\/td><td>889<\/td><td>1.240<\/td><td>1104<\/td><\/tr>\n                            <tr><td class=\"size-cell\">4 AWG<\/td><td>21<\/td><td>37-104-565<\/td><td>1.214<\/td><td>1142<\/td><td>1.264<\/td><td>1340<\/td><td>1.464<\/td><td>1597<\/td><\/tr>\n                            <tr><td class=\"size-cell\">2 AWG<\/td><td>34<\/td><td>37-104-566<\/td><td>1.395<\/td><td>1655<\/td><td>1.445<\/td><td>1884<\/td><td>1.645<\/td><td>2175<\/td><\/tr>\n                            <tr><td class=\"size-cell\">1 AWG<\/td><td>43<\/td><td>37-104-567<\/td><td>1.565<\/td><td>2051<\/td><td>1.616<\/td><td>2307<\/td><td>1.874<\/td><td>2737<\/td><\/tr>\n                            <tr><td class=\"size-cell\">1\/0 AWG<\/td><td>54<\/td><td>37-104-568<\/td><td>1.763<\/td><td>2651<\/td><td>1.813<\/td><td>2932<\/td><td>2.072<\/td><td>3411<\/td><\/tr>\n                            <tr><td class=\"size-cell\">2\/0 AWG<\/td><td>70<\/td><td>37-104-569<\/td><td>1.911<\/td><td>3244<\/td><td>1.962<\/td><td>3551<\/td><td>2.220<\/td><td>4066<\/td><\/tr>\n                            <tr><td class=\"size-cell\">4\/0 AWG<\/td><td>109<\/td><td>37-104-746<\/td><td>2.212<\/td><td>4722<\/td><td>2.262<\/td><td>5076<\/td><td>2.521<\/td><td>5666<\/td><\/tr>\n                        <\/tbody>\n                    <\/table>\n                <\/div>\n\n                <!-- Electrical Parameters Table -->\n                <div class=\"table-wrapper\" style=\"margin-top: 24px;\">\n                    <div class=\"table-title\"><span class=\"icon\">\u26a1<\/span> Electrical Parameters \u96fb\u6c23\u53c3\u6578<\/div>\n                    <table>\n                        <thead>\n                            <tr>\n                                <th>Size<span class=\"unit\">\u5c3a\u5bf8<\/span><\/th>\n                                <th>DC Res. @25\u00b0C<span class=\"unit\">\u76f4\u6d41\u96fb\u963b (\u03a9\/kft)<\/span><\/th>\n                                <th>AC Res. @90\u00b0C<span class=\"unit\">\u4ea4\u6d41\u96fb\u963b (\u03a9\/kft)<\/span><\/th>\n                                <th>Reactance<span class=\"unit\">\u611f\u6297 (\u03a9\/kft)<\/span><\/th>\n                                <th>Voltage Drop<span class=\"unit\">\u96fb\u58d3\u964d (V\/A\/kft)<\/span><\/th>\n                                <th>Ampacity 90\u00b0C<span class=\"unit\">\u8f09\u6d41\u91cf (A)<\/span><\/th>\n                                <th>Ampacity 75\u00b0C<span class=\"unit\">\u8f09\u6d41\u91cf (A)<\/span><\/th>\n                                <th>Ampacity 60\u00b0C<span class=\"unit\">\u8f09\u6d41\u91cf (A)<\/span><\/th>\n                            <\/tr>\n                        <\/thead>\n                        <tbody>\n                            <tr><td class=\"size-cell\">18 AWG<\/td><td>7.354<\/td><td>9.196<\/td><td>0.048<\/td><td>12.777<\/td><td class=\"highlight-cell\">9<\/td><td>7<\/td><td>5<\/td><\/tr>\n                            <tr><td class=\"size-cell\">16 AWG<\/td><td>4.610<\/td><td>5.765<\/td><td>0.045<\/td><td>8.025<\/td><td class=\"highlight-cell\">12<\/td><td>10<\/td><td>7<\/td><\/tr>\n                            <tr><td class=\"size-cell\">14 AWG<\/td><td>2.907<\/td><td>3.635<\/td><td>0.042<\/td><td>5.075<\/td><td class=\"highlight-cell\">19<\/td><td>16<\/td><td>12<\/td><\/tr>\n                            <tr><td class=\"size-cell\">12 AWG<\/td><td>1.826<\/td><td>2.283<\/td><td>0.039<\/td><td>3.201<\/td><td class=\"highlight-cell\">23<\/td><td>19<\/td><td>14<\/td><\/tr>\n                            <tr><td class=\"size-cell\">10 AWG<\/td><td>1.153<\/td><td>1.441<\/td><td>0.037<\/td><td>2.034<\/td><td class=\"highlight-cell\">30<\/td><td>26<\/td><td>18<\/td><\/tr>\n                            <tr><td class=\"size-cell\">8 AWG<\/td><td>0.708<\/td><td>0.885<\/td><td>0.039<\/td><td>1.265<\/td><td class=\"highlight-cell\">38<\/td><td>33<\/td><td>23<\/td><\/tr>\n                            <tr><td class=\"size-cell\">6 AWG<\/td><td>0.445<\/td><td>0.556<\/td><td>0.036<\/td><td>0.807<\/td><td class=\"highlight-cell\">52<\/td><td>43<\/td><td>32<\/td><\/tr>\n                            <tr><td class=\"size-cell\">4 AWG<\/td><td>0.300<\/td><td>0.376<\/td><td>0.033<\/td><td>0.554<\/td><td class=\"highlight-cell\">66<\/td><td>56<\/td><td>40<\/td><\/tr>\n                            <tr><td class=\"size-cell\">2 AWG<\/td><td>0.184<\/td><td>0.230<\/td><td>0.032<\/td><td>0.351<\/td><td class=\"highlight-cell\">89<\/td><td>74<\/td><td>54<\/td><\/tr>\n                            <tr><td class=\"size-cell\">1 AWG<\/td><td>0.147<\/td><td>0.184<\/td><td>0.032<\/td><td>0.287<\/td><td class=\"highlight-cell\">105<\/td><td>88<\/td><td>64<\/td><\/tr>\n                            <tr><td class=\"size-cell\">1\/0 AWG<\/td><td>0.117<\/td><td>0.147<\/td><td>0.031<\/td><td>0.237<\/td><td class=\"highlight-cell\">120<\/td><td>101<\/td><td>73<\/td><\/tr>\n                            <tr><td class=\"size-cell\">2\/0 AWG<\/td><td>0.093<\/td><td>0.117<\/td><td>0.030<\/td><td>0.195<\/td><td class=\"highlight-cell\">138<\/td><td>116<\/td><td>84<\/td><\/tr>\n                            <tr><td class=\"size-cell\">4\/0 AWG<\/td><td>0.058<\/td><td>0.075<\/td><td>0.029<\/td><td>0.135<\/td><td class=\"highlight-cell\">186<\/td><td>155<\/td><td>112<\/td><\/tr>\n                        <\/tbody>\n                    <\/table>\n                <\/div>\n\n                <div class=\"comparison-note\">\n                    <strong>Manufacturing Tolerance \u88fd\u9020\u516c\u5dee\uff1a<\/strong> Cable diameters shown as nominal are subject to a \u00b15% manufacturing tolerance. All resistance values measured per IEEE 1580 and ICEA test methods. Ampacity ratings are for free air installation at 40\u00b0C ambient temperature. Five-conductor ampacity is derated from single conductor values due to mutual heating effects.<br><br>\n                    \u96fb\u7e9c\u76f4\u5f91\u70ba\u6a19\u7a31\u503c\uff0c\u53d7 \u00b15% \u88fd\u9020\u516c\u5dee\u9650\u5236\u3002\u6240\u6709\u96fb\u963b\u503c\u5747\u6309 IEEE 1580 \u548c ICEA \u6e2c\u8a66\u65b9\u6cd5\u6e2c\u91cf\u3002\u8f09\u6d41\u91cf\u984d\u5b9a\u503c\u9069\u7528\u65bc40\u00b0C\u74b0\u5883\u6eab\u5ea6\u4e0b\u7684\u81ea\u7531\u7a7a\u6c23\u5b89\u88dd\u3002\u7531\u65bc\u4e92\u71b1\u6548\u61c9\uff0c\u4e94\u82af\u96fb\u7e9c\u8f09\u6d41\u91cf\u76f8\u5c0d\u55ae\u82af\u96fb\u7e9c\u9032\u884c\u4e86\u964d\u984d\u8655\u7406\u3002\n                <\/div>\n            <\/section>\n\n            <!-- Hawke Gland Compatibility -->\n            <section id=\"glands\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\ud83d\udd29<\/span> Hawke Gland Compatibility \u96fb\u7e9c\u63a5\u982d\u517c\u5bb9\u6027<\/h2>\n                    <p class=\"subtitle\">Recommended cable gland types for hazardous area installations<\/p>\n                <\/div>\n\n                <div class=\"table-wrapper\">\n                    <div class=\"table-title\"><span class=\"icon\">\u2699\ufe0f<\/span> Hawke Gland Selection Guide \u63a5\u982d\u9078\u64c7\u6307\u5357<\/div>\n                    <table>\n                        <thead>\n                            <tr>\n                                <th>Application \u61c9\u7528<\/th>\n                                <th>Area Classification \u5340\u57df\u5206\u985e<\/th>\n                                <th>Unarmored \u7121\u93a7\u88dd<\/th>\n                                <th>Armored &amp; Sheathed \u93a7\u88dd\u8b77\u5957<\/th>\n                            <\/tr>\n                        <\/thead>\n                        <tbody>\n                            <tr>\n                                <td>Industrial &amp; Safe Area (IP68)<\/td>\n                                <td>General \u4e00\u822c\u5340\u57df<\/td>\n                                <td>121<\/td>\n                                <td>153-X<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>Increased Safety &#8220;EExe&#8221;<\/td>\n                                <td>\u2014<\/td>\n                                <td>501\/421<\/td>\n                                <td>501\/453\/U<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>Explosion Proof &#8220;EExd&#8221;<\/td>\n                                <td>Class I, Div. 1 \/ Zone 1 &amp; 2<\/td>\n                                <td>710<\/td>\n                                <td>753<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>Flameproof<\/td>\n                                <td>Zone 1 &amp; 2 (\u22642L enclosures)<\/td>\n                                <td>501\/421<\/td>\n                                <td>501\/453\/U<\/td>\n                            <\/tr>\n                            <tr>\n                                <td>Flameproof<\/td>\n                                <td>Zone 1 &amp; 2 (&gt;2L enclosures)<\/td>\n                                <td>\u2014<\/td>\n                                <td>ICG 653\/U<\/td>\n                            <\/tr>\n                        <\/tbody>\n                    <\/table>\n                <\/div>\n            <\/section>\n\n            <!-- Ordering Information -->\n            <section id=\"ordering\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\ud83d\uded2<\/span> Ordering Information \u8a02\u8cfc\u4fe1\u606f<\/h2>\n                    <p class=\"subtitle\">How to specify GEXOL\u00ae-331HF Five Conductor cables<\/p>\n                <\/div>\n\n                <div class=\"bilingual-block\">\n                    <div class=\"lang-en\">\n                        <span class=\"lang-label\">\ud83c\uddec\ud83c\udde7 English<\/span>\n                        <p><strong>Ordering Example:<\/strong> For a five conductor power cable, 0.6\/1kV rated, #2 AWG size with bronze armor and outer sheath, specify the cable using the format shown below. The five-conductor configuration is ideal for 3-phase plus neutral plus ground (3P+N+PE) systems or multi-circuit control applications. Contact our technical team for custom configurations including special lengths or alternative armor materials.<\/p>\n                    <\/div>\n                    <div class=\"lang-zh\">\n                        <span class=\"lang-label\">\ud83c\uddf9\ud83c\uddfc \u7e41\u9ad4\u4e2d\u6587<\/span>\n                        <p><strong>\u8a02\u8cfc\u793a\u4f8b\uff1a<\/strong>\u5982\u9700\u8a02\u8cfc 0.6\/1kV \u984d\u5b9a\u3001#2 AWG \u898f\u683c\u3001\u5e36\u9752\u9285\u93a7\u88dd\u548c\u5916\u8b77\u5957\u7684\u4e94\u82af\u96fb\u529b\u96fb\u7e9c\uff0c\u8acb\u4f7f\u7528\u4ee5\u4e0b\u683c\u5f0f\u6307\u5b9a\u96fb\u7e9c\u3002\u4e94\u5c0e\u9ad4\u914d\u7f6e\u975e\u5e38\u9069\u5408\u4e09\u76f8\u52a0\u4e2d\u6027\u7dda\u52a0\u63a5\u5730\uff083P+N+PE\uff09\u7cfb\u7d71\u6216\u591a\u96fb\u8def\u63a7\u5236\u61c9\u7528\u3002\u5982\u9700\u7279\u6b8a\u9577\u5ea6\u6216\u66ff\u4ee3\u93a7\u88dd\u6750\u6599\u7b49\u5b9a\u5236\u914d\u7f6e\uff0c\u8acb\u806f\u7e6b\u6211\u5011\u7684\u6280\u8853\u5718\u968a\u3002<\/p>\n                    <\/div>\n                <\/div>\n\n                <div class=\"ordering-example\">\n                    <p style=\"margin-bottom: 11px; color: var(--text-secondary); font-family: var(--font-sans);\">Format \u683c\u5f0f\uff1a<\/p>\n                    <p style=\"font-size: 1rem; letter-spacing: 0.5px;\">\n                        <span class=\"prefix\">AmerCable GEXOL-331HF<\/span> \n                        <span style=\"color: var(--text-muted);\">+<\/span> \n                        <span class=\"part-no\">37-104-566<\/span> \n                        <span style=\"color: var(--text-muted);\">+<\/span> \n                        <span class=\"armor\">BS<\/span>\n                    <\/p>\n                    <p style=\"margin-top: 14px; font-size: 0.78rem; color: var(--text-secondary); font-family: var(--font-sans);\">\n                        <strong style=\"color: var(--accent-green);\">Prefix:<\/strong> AmerCable GEXOL-331HF &nbsp;|&nbsp; \n                        <strong style=\"color: var(--accent-blue);\">Part No.:<\/strong> From table \u5f9e\u8868\u683c\u9078\u64c7 &nbsp;|&nbsp; \n                        <strong style=\"color: var(--accent-orange);\">Armor:<\/strong> BS = armored &amp; sheathed \u93a7\u88dd\u8b77\u5957, B = armored only \u50c5\u93a7\u88dd, Blank = unarmored \u7121\u93a7\u88dd\n                    <\/p>\n                <\/div>\n\n                <div class=\"info-grid\" style=\"margin-top: 20px;\">\n                    <div class=\"info-card\">\n                        <h3>\ud83d\udce6 Configuration Options \u914d\u7f6e\u9078\u9805<\/h3>\n                        <ul>\n                            <li><strong>BS:<\/strong> Bronze armor with outer sheath \u9752\u9285\u93a7\u88dd\u5e36\u5916\u8b77\u5957<\/li>\n                            <li><strong>B:<\/strong> Bronze basket weave armor only \u50c5\u9752\u9285\u7de8\u7e54\u93a7\u88dd<\/li>\n                            <li><strong>Blank:<\/strong> Unarmored configuration \u7121\u93a7\u88dd\u914d\u7f6e<\/li>\n                            <li><strong>Tinned Cu:<\/strong> Armor available by request \u934d\u932b\u9285\u93a7\u88dd\u6309\u9700\u63d0\u4f9b<\/li>\n                            <li><strong>Aluminum:<\/strong> Armor available by request \u92c1\u93a7\u88dd\u6309\u9700\u63d0\u4f9b<\/li>\n                        <\/ul>\n                    <\/div>\n                    <div class=\"info-card\">\n                        <h3>\ud83d\udd0c Common Applications \u5e38\u898b\u61c9\u7528<\/h3>\n                        <ul>\n                            <li><strong>3P+N+PE:<\/strong> Three phase + neutral + ground \u4e09\u76f8+\u4e2d\u6027+\u63a5\u5730<\/li>\n                            <li><strong>VFD Systems:<\/strong> Variable frequency drives \u8b8a\u983b\u9a45\u52d5\u5668<\/li>\n                            <li><strong>Motor Control:<\/strong> With feedback circuits \u5e36\u53cd\u994b\u96fb\u8def<\/li>\n                            <li><strong>Instrumentation:<\/strong> Multi-channel signals \u591a\u901a\u9053\u4fe1\u865f<\/li>\n                            <li><strong>Control:<\/strong> Five-wire control circuits \u4e94\u7dda\u63a7\u5236\u96fb\u8def<\/li>\n                        <\/ul>\n                    <\/div>\n                <\/div>\n            <\/section>\n\n            <!-- External References -->\n            <section id=\"references\">\n                <div class=\"section-header\">\n                    <h2><span class=\"icon\">\ud83d\udcda<\/span> Authoritative References \u6b0a\u5a01\u53c3\u8003\u8cc7\u6599<\/h2>\n                    <p class=\"subtitle\">International standards and certification bodies for marine cables<\/p>\n                <\/div>\n\n                <div class=\"references\">\n                    <h3>\ud83d\udcd6 International Standards \u570b\u969b\u6a19\u6e96<\/h3>\n                    <ul class=\"ref-list\">\n                        <li>\n                            <span class=\"ref-number\">1<\/span>\n                            <span class=\"ref-text\"><strong>IEEE 1580-2021<\/strong> &#8211; Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Offshore Facilities.<\/span>\n                            <a href=\"https:\/\/standards.ieee.org\/ieee\/1580\/10835\/\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">standards.ieee.org<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">2<\/span>\n                            <span class=\"ref-text\"><strong>IEC 60331<\/strong> &#8211; Tests for electric cables under fire conditions &#8211; Circuit integrity.<\/span>\n                            <a href=\"https:\/\/webstore.iec.ch\/publication\/1473\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">webstore.iec.ch<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">3<\/span>\n                            <span class=\"ref-text\"><strong>IEC 60332-3<\/strong> &#8211; Tests on electric cables under fire conditions &#8211; Vertical flame spread test.<\/span>\n                            <a href=\"https:\/\/webstore.iec.ch\/publication\/1479\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">webstore.iec.ch<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">4<\/span>\n                            <span class=\"ref-text\"><strong>IEC 60092-350<\/strong> &#8211; Electrical installations in ships &#8211; General construction and test methods.<\/span>\n                            <a href=\"https:\/\/webstore.iec.ch\/publication\/683\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">webstore.iec.ch<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">5<\/span>\n                            <span class=\"ref-text\"><strong>UL 1309<\/strong> &#8211; Standard for Marine Shipboard Cable.<\/span>\n                            <a href=\"https:\/\/www.ul.com\/resources\/ul-1309-marine-shipboard-cable\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">ul.com<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">6<\/span>\n                            <span class=\"ref-text\"><strong>CSA C22.2 No. 245<\/strong> &#8211; Thermoplastic-insulated wires and cables.<\/span>\n                            <a href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%20245\/\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">csagroup.org<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">7<\/span>\n                            <span class=\"ref-text\"><strong>IEEE 1202<\/strong> &#8211; Standard for Flame-Propagation Testing of Wire and Cable.<\/span>\n                            <a href=\"https:\/\/standards.ieee.org\/ieee\/1202\/6029\/\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">standards.ieee.org<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">8<\/span>\n                            <span class=\"ref-text\"><strong>IEC 60754-1<\/strong> &#8211; Test on gases evolved during combustion &#8211; Halogen acid gas.<\/span>\n                            <a href=\"https:\/\/webstore.iec.ch\/publication\/3407\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">webstore.iec.ch<\/a>\n                        <\/li>\n                    <\/ul>\n                <\/div>\n\n                <div class=\"references\" style=\"margin-top: 18px;\">\n                    <h3>\ud83c\udfdb\ufe0f Classification Societies \u8239\u7d1a\u793e<\/h3>\n                    <ul class=\"ref-list\">\n                        <li>\n                            <span class=\"ref-number\">A<\/span>\n                            <span class=\"ref-text\"><strong>American Bureau of Shipping (ABS)<\/strong> &#8211; Type approval for marine cables.<\/span>\n                            <a href=\"https:\/\/ww2.eagle.org\/\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">eagle.org<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">B<\/span>\n                            <span class=\"ref-text\"><strong>DNV GL<\/strong> &#8211; Det Norske Veritas Germanischer Lloyd classification.<\/span>\n                            <a href=\"https:\/\/www.dnv.com\/\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">dnv.com<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">C<\/span>\n                            <span class=\"ref-text\"><strong>Lloyd&#8217;s Register<\/strong> &#8211; LRS certification for marine electrical equipment.<\/span>\n                            <a href=\"https:\/\/www.lr.org\/\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">lr.org<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">D<\/span>\n                            <span class=\"ref-text\"><strong>Transport Canada<\/strong> &#8211; Canadian maritime safety regulations.<\/span>\n                            <a href=\"https:\/\/tc.canada.ca\/en\/marine-transportation\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">tc.canada.ca<\/a>\n                        <\/li>\n                    <\/ul>\n                <\/div>\n\n                <div class=\"references\" style=\"margin-top: 18px;\">\n                    <h3>\ud83d\udd2c Technical Resources \u6280\u8853\u8cc7\u6e90<\/h3>\n                    <ul class=\"ref-list\">\n                        <li>\n                            <span class=\"ref-number\">I<\/span>\n                            <span class=\"ref-text\"><strong>NEMA WC 57<\/strong> &#8211; Standard for Control and Instrumentation Cables.<\/span>\n                            <a href=\"https:\/\/www.nema.org\/standards\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">nema.org<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">II<\/span>\n                            <span class=\"ref-text\"><strong>API RP 14F<\/strong> &#8211; Electrical Systems for Offshore Petroleum Facilities.<\/span>\n                            <a href=\"https:\/\/www.api.org\/products-and-services\/standards\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">api.org<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">III<\/span>\n                            <span class=\"ref-text\"><strong>ICEA S-95-658<\/strong> &#8211; Standard for Nonshielded Power Cables.<\/span>\n                            <a href=\"https:\/\/www.icea.net\/\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">icea.net<\/a>\n                        <\/li>\n                        <li>\n                            <span class=\"ref-number\">IV<\/span>\n                            <span class=\"ref-text\"><strong>NEC Article 250<\/strong> &#8211; Grounding and Bonding requirements.<\/span>\n                            <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" class=\"ref-link\" rel=\"nofollow noopener\" target=\"_blank\">nfpa.org<\/a>\n                        <\/li>\n                    <\/ul>\n                <\/div>\n            <\/section>\n\n        <\/div>\n    <\/main>\n\n    <!-- Footer -->\n    <footer>\n        <div class=\"container\">\n            <div class=\"footer-content\">\n                <div class=\"footer-section\">\n                    <h4>Anhui Feichun Special Cable Co., Ltd.<\/h4>\n                    <p>\u5b89\u5fbd\u98db\u7d14\u7279\u7a2e\u96fb\u7e9c\u6709\u9650\u516c\u53f8<\/p>\n                    <p style=\"margin-top: 9px;\">Professional manufacturer of fire-resistant, low smoke halogen-free marine and offshore cables meeting IEEE 1580, IEC 60331, UL 1309, and DNV-GL requirements. Specializing in multi-conductor power cables for complex electrical systems.<\/p>\n                <\/div>\n                <div class=\"footer-section\">\n                    <h4>Contact Us \u806f\u7e6b\u6211\u5011<\/h4>\n                    <ul class=\"footer-contact\">\n                        <li>\n                            <a href=\"mailto:tech@feichuncables.com\" rel=\"nofollow\">\n                                <svg width=\"13\" height=\"13\" viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"><path d=\"M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z\"\/><polyline points=\"22,6 12,13 2,6\"\/><\/svg>\n                                tech@feichuncables.com\n                            <\/a>\n                        <\/li>\n                        <li>\n                            <a href=\"mailto:zihao.yang@feichuncable.com\" rel=\"nofollow\">\n                                <svg width=\"13\" height=\"13\" viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"><path d=\"M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z\"\/><polyline points=\"22,6 12,13 2,6\"\/><\/svg>\n                                zihao.yang@feichuncable.com\n                            <\/a>\n                        <\/li>\n                        <li>\n                            <a href=\"mailto:ziyu.huang@feichuncables.com\" rel=\"nofollow\">\n                                <svg width=\"13\" height=\"13\" viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\"><path d=\"M4 4h16c1.1 0 2 .9 2 2v12c0 1.1-.9 2-2 2H4c-1.1 0-2-.9-2-2V6c0-1.1.9-2 2-2z\"\/><polyline points=\"22,6 12,13 2,6\"\/><\/svg>\n                                ziyu.huang@feichuncables.com\n                            <\/a>\n                        <\/li>\n                    <\/ul>\n                    <a href=\"https:\/\/wa.me\/8613855123218\" class=\"whatsapp-btn\" rel=\"nofollow noopener\" target=\"_blank\">\n                        <svg width=\"15\" height=\"15\" viewBox=\"0 0 24 24\" fill=\"currentColor\"><path d=\"M17.472 14.382c-.297-.149-1.758-.867-2.03-.967-.273-.099-.471-.148-.67.15-.197.297-.767.966-.94 1.164-.173.199-.347.223-.644.075-.297-.15-1.255-.463-2.39-1.475-.883-.788-1.48-1.761-1.653-2.059-.173-.297-.018-.458.13-.606.134-.133.298-.347.446-.52.149-.174.198-.298.298-.497.099-.198.05-.371-.025-.52-.075-.149-.669-1.612-.916-2.207-.242-.579-.487-.5-.669-.51-.173-.008-.371-.01-.57-.01-.198 0-.52.074-.792.372-.272.297-1.04 1.016-1.04 2.479 0 1.462 1.065 2.875 1.213 3.074.149.198 2.096 3.2 5.077 4.487.709.306 1.262.489 1.694.625.712.227 1.36.195 1.871.118.571-.085 1.758-.719 2.006-1.413.248-.694.248-1.289.173-1.413-.074-.124-.272-.198-.57-.347m-5.421 7.403h-.004a9.87 9.87 0 01-5.031-1.378l-.361-.214-3.741.982.998-3.648-.235-.374a9.86 9.86 0 01-1.51-5.26c.001-5.45 4.436-9.884 9.888-9.884 2.64 0 5.122 1.03 6.988 2.898a9.825 9.825 0 012.893 6.994c-.003 5.45-4.437 9.884-9.885 9.884m8.413-18.297A11.815 11.815 0 0012.05 0C5.495 0 .16 5.335.157 11.892c0 2.096.547 4.142 1.588 5.945L.057 24l6.305-1.654a11.882 11.882 0 005.683 1.448h.005c6.554 0 11.89-5.335 11.893-11.893a11.821 11.821 0 00-3.48-8.413z\"\/><\/svg>\n                        WhatsApp: +86 138 5512 3218\n                    <\/a>\n                <\/div>\n                <div class=\"footer-section\">\n                    <h4>Quick Links \u5feb\u901f\u9023\u7d50<\/h4>\n                    <ul class=\"footer-contact\">\n                        <li><a href=\"#overview\">Product Overview \u7522\u54c1\u6982\u8ff0<\/a><\/li>\n                        <li><a href=\"#certifications\">Certifications \u8a8d\u8b49<\/a><\/li>\n                        <li><a href=\"#construction\">Construction \u7d50\u69cb<\/a><\/li>\n                        <li><a href=\"#specifications\">Specifications \u898f\u683c<\/a><\/li>\n                        <li><a href=\"#applications\">Applications \u61c9\u7528<\/a><\/li>\n                        <li><a href=\"#ordering\">Ordering \u8a02\u8cfc<\/a><\/li>\n                        <li><a href=\"#references\">References \u53c3\u8003\u8cc7\u6599<\/a><\/li>\n                    <\/ul>\n                <\/div>\n            <\/div>\n            <div class=\"footer-bottom\">\n                <p>&copy; 2024 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98db\u7d14\u7279\u7a2e\u96fb\u7e9c\u6709\u9650\u516c\u53f8. All Rights Reserved.<\/p>\n                <p style=\"margin-top: 4px; font-size: 0.72rem;\">GEXOL\u00ae is a registered trademark of AmerCable Incorporated. Manufactured by Nexans AmerCable. Technical specifications subject to change without notice.<\/p>\n            <\/div>\n        <\/div>\n    <\/footer>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"GEXOL-331HF, GEXOL-331HF five conductor, GEXOL 331HF 5 conductor cable, GEXOL-331HF fire resistant cable, GEXOL-331HF 0.6\/1kV cable, GEXOL-331HF five core cable, GEXOL-331HF power cable, AmerCable GEXOL-331HF, Nexans AmerCable GEXOL, GEXOL-HF insulation, \u8010\u706b\u96fb\u7e9c, \u4e94\u82af\u96fb\u7e9c, \u4e94\u82af\u96fb\u529b\u96fb\u7e9c, \u4e94\u76f8\u96fb\u7e9c, \u4f4e\u7159\u7121\u9e75\u96fb\u7e9c, \u4f4e\u7159\u7121\u9e75\u4e94\u82af\u96fb\u7e9c, \u8239\u7528\u96fb\u7e9c, \u8239\u7528\u4e94\u82af\u96fb\u7e9c, \u96e2\u5cb8\u96fb\u7e9c, \u6d77\u6d0b\u96fb\u7e9c, 0.6\/1kV\u96fb\u7e9c, 600V\/1000V\u96fb\u7e9c, 90\u5ea6\u984d\u5b9a\u96fb\u7e9c, \u963b\u71c3\u96fb\u7e9c, \u93a7\u88dd\u96fb\u7e9c, \u9752\u9285\u93a7\u88dd, \u934d\u932b\u9285\u5c0e\u9ad4, \u4ea4\u806f\u805a\u70ef\u70f4, \u7dca\u6025\u7167\u660e\u96fb\u7e9c, \u6d88\u9632\u7cfb\u7d71\u96fb\u7e9c, \u6d88\u9632\u6cf5\u96fb\u7e9c, \u591a\u82af\u96fb\u6a5f\u96fb\u7e9c, \u5371\u96aa\u5340\u57df\u96fb\u7e9c, \u8239\u7d1a\u793e\u8a8d\u8b49, DNV\u8a8d\u8b49\u96fb\u7e9c, ABS\u8a8d\u8b49\u96fb\u7e9c, IEEE 1580\u6a19\u6e96, IEC 60331\u6a19\u6e96, \u9ed1\u767d\u7d05\u7da0\u6a59\u8272\u78bc, \u76f8\u4f4d\u8b58\u5225, \u4e09\u76f8\u52a0\u4e2d\u6027\u7dda\u52a0\u63a5\u5730, \u8b8a\u983b\u9a45\u52d5\u5668\u96fb\u7e9c, \u904e\u7a0b\u63a7\u5236\u96fb\u7e9c, \u5b89\u5fbd\u98db\u7d14\u7279\u7a2e\u96fb\u7e9c","protected":false},"author":1,"featured_media":3553,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[97],"tags":[17894,10929,2256,11855,17961,17956,17947,17955,17948,17952,17890,17821,17984,8483,2750,17685,3165,14621,17688,17721,17797,17697,17724,17726,17980,17950,17725,1945,17782,17722,17783,11466,17718,17708,17791,17977,17978,17793,11444,17693,17785,17755,17784,17753,10203,1214,1170,17756,13538,10211,17941,15428,17728,17716,11492,13598,17946,17986,17951,17949,17954,1253,17754,3366,17976,14410,17945,17764,11521,17787,17696,17944,17943,17699,11455,17715,17827,17830,17826,17825,17829,17828,17751,17831,1141,8805,17706,17709,15582,17703,17694,17979,17792,2272,17707,17705,17704,17790,17747,17763,17692,1029,17758,1135,3166,14393,98,17711,17800,14394,15229,17801,99,17844,385,17842,17761,2010,1072,17987,17846,17701,17710,17983,1028,17843,17757,17720,17762,5374,1259,11464,17796,17760,17727,10448,17973,17719,17731,1016,17759,17959,17957,17958,17730,919,15919,17712,17893,17981,17895,17982,11440,17732,2025,1247,1088,17972,17985,17960,17717,17963,17968,17965,17967,17687,17969,12895,17690,17966,12012,17682,17862,17689,17866,13396,14433,17971,14438,17691,17964,13462,11812,15683,11571,17681,17686,17970],"class_list":["post-3552","post","type-post","status-publish","format-standard","has-post-thumbnail","category-lszh-low-smoke-zero-halogen-flexible-cable","tag-35c-cold-impact","tag-40c-cold-bend-cable","tag-0-6-1kv-power-cable","tag-0-6-1kv","tag-3-phase-plus-neutral-plus-ground","tag-3pnpe-cable","tag-5-conductor-marine-cable","tag-5-wire-three-phase","tag-5-core-cable","tag-5-core-marine-cable","tag-600v-1000v-rated-cable","tag-600v-1000v","tag-60hz-ac-resistance","tag-90c-continuous-rating","tag-90c-rated-cable","tag-17685","tag-abs-approved-cable","tag-abs-type-approval","tag-abs","tag-alarm-system-cable","tag-aluminum-armor-cable","tag-amercable-gexol-331hf","tag-armored-marine-cable","tag-basket-weave-armor","tag-basket-weave-armor-ieee-1580","tag-black-white-red-green-orange-color-code","tag-bronze-armor-cable","tag-class-i-division-1-cable","tag-class-i-division-2","tag-class-i-zone-1-cable","tag-class-i-zone-2","tag-critical-circuit-cable","tag-cross-linked-polyolefin-cable","tag-csa-245-cable","tag-csa-c22-2-no-245","tag-csa-cold-bend-40c","tag-csa-cold-impact-35c","tag-dnv-maritime-cable","tag-dnv-gl-certified-cable","tag-dnv","tag-eexd-cable","tag-eexd-cable-gland","tag-eexe-cable","tag-eexe-cable-gland","tag-emergency-generator-cable","tag-emergency-lighting-cable","tag-explosion-proof-cable","tag-explosion-proof-gland","tag-fire-detection-cable","tag-fire-pump-cable","tag-fire-pump-motor-cable","tag-fire-resistant-cable-comparison","tag-fire-resistant-jacket","tag-fire-resistant-tape-insulation","tag-fire-resistant-vs-flame-retardant-cable","tag-fire-suppression-system-cable","tag-five-conductor-power-cable","tag-five-conductor-voltage-drop-calculation","tag-five-core-cable","tag-five-core-power-cable","tag-five-wire-system","tag-flameproof-cable","tag-flameproof-gland","tag-flexible-stranded-conductor","tag-four-conductor-vs-five-conductor-marine-cable","tag-fpso-cable","tag-gexol-331hf-5-conductor-cable","tag-gexol-vs-iec-60092-350","tag-gexol-331hf","tag-gexol-331hf-0-6-1kv-cable","tag-gexol-331hf-fire-resistant-cable","tag-gexol-331hf-five-conductor","tag-gexol-331hf-five-core-cable","tag-gexol-331hf-power-cable","tag-gexol-hf-insulation","tag-halogen-free-power-cable","tag-hawke-121-gland","tag-hawke-153-x","tag-hawke-501-421","tag-hawke-501-453-u","tag-hawke-710","tag-hawke-753","tag-hawke-cable-gland","tag-hawke-icg-653-u","tag-hazardous-location-cable","tag-high-strand-count-cable","tag-iec-332-3-category-a","tag-iec-60092-350-cable","tag-iec-60331-cable","tag-iec-60331-fire-resistant","tag-iec-60331","tag-iec-60754-1-halogen-content","tag-iec-60754-1-halogen-test","tag-iec-61034-smoke-density","tag-ieee-1202-flame-retardant","tag-ieee-1580-cable","tag-ieee-1580-marine-cable","tag-ieee-1580-table-11","tag-ieee-1580-table-11-conductor","tag-ieee-1580-vs-iec-60092","tag-ieee-1580","tag-instrumentation-cable","tag-ip68-cable-gland","tag-life-safety-cable","tag-lloyds-register-cable","tag-low-smoke-halogen-free-cable","tag-low-smoke-zero-halogen","tag-lrs-approved-marine-cable","tag-lse-type-insulation","tag-lshf-cable","tag-lsoh-cable","tag-lsx-type-insulation","tag-lszh-cable","tag-lszh-vs-pvc-cable-marine","tag-marine-cable","tag-marine-cable-specification-comparison","tag-marine-switchgear-cable","tag-motor-control-cable","tag-multi-conductor-cable","tag-multi-conductor-derating-factors","tag-multi-conductor-marine-cable-selection","tag-nexans-amercable-gexol","tag-nrtl-certified-cable","tag-nrtl-classified-ieee-1580","tag-offshore-cable","tag-offshore-cable-selection-guide","tag-offshore-drilling-equipment-cable","tag-offshore-facility-cable","tag-offshore-generator-cable","tag-offshore-platform-cable","tag-oil-and-gas-cable","tag-personnel-egress-cable","tag-phase-identification-cable","tag-platform-electrical-system","tag-polyolefin-jacket","tag-process-control-cable","tag-process-control-equipment","tag-severe-cold-cable","tag-sheathed-cable","tag-shipboard-cable","tag-shipboard-electrical-installation","tag-star-connected-cable","tag-three-phase-neutral-ground","tag-three-phase-with-neutral-and-earth","tag-tinned-copper-armor","tag-tinned-copper-conductor-cable","tag-tn-s-system-cable","tag-transport-canada-approved-cable","tag-type-lse-cable","tag-type-lse-insulation","tag-type-lsx-cable","tag-type-lsx-insulation","tag-ul-1309-marine-cable","tag-unarmored-cable","tag-variable-frequency-drive","tag-variable-frequency-drive-cable","tag-vfd-cable","tag-vfd-motor-feeder","tag-voltage-drop-per-amp-per-1000ft","tag-wye-system-cable","tag-xlpo-insulation-cable","tag-17963","tag-17968","tag-17965","tag-17967","tag-17687","tag-17969","tag-12895","tag-17690","tag-17966","tag-12012","tag-17682","tag-17862","tag-17689","tag-17866","tag-13396","tag-14433","tag-17971","tag-14438","tag-17691","tag-17964","tag-13462","tag-11812","tag-15683","tag-11571","tag-17681","tag-17686","tag-17970","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/3552","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=3552"}],"version-history":[{"count":3,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/3552\/revisions"}],"predecessor-version":[{"id":3557,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/3552\/revisions\/3557"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/3553"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=3552"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=3552"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=3552"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}