{"id":20832,"date":"2026-06-23T15:27:24","date_gmt":"2026-06-23T07:27:24","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=20832"},"modified":"2026-06-23T17:21:45","modified_gmt":"2026-06-23T09:21:45","slug":"o-que-e-o-tunnelflex-ttx-analise-de-engenharia-aprofundada-do-cabo-de-media-tensao-36-6-a-12-20-kv-com-protecao-anti-torcao","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/o-que-e-o-tunnelflex-ttx-analise-de-engenharia-aprofundada-do-cabo-de-media-tensao-36-6-a-12-20-kv-com-protecao-anti-torcao\/","title":{"rendered":"O que \u00e9 o TUNNELFLEX-TTX: An\u00e1lise de Engenharia Aprofundada do Cabo de M\u00e9dia Tens\u00e3o 3,6\/6 a 12\/20 kV COM Prote\u00e7\u00e3o Anti-Tor\u00e7\u00e3o"},"content":{"rendered":"\n<!DOCTYPE html>\n<html lang=\"pt-BR\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0, viewport-fit=cover\">\n<meta name=\"description\" content=\"O que \u00e9 o cabo TUNNELFLEX-TTX RS-(N)TSCGEWOEU de m\u00e9dia tens\u00e3o 3,6\/6 a 12\/20kV COM prote\u00e7\u00e3o anti-tor\u00e7\u00e3o? An\u00e1lise t\u00e9cnica aprofundada da vers\u00e3o de m\u00e9dia tens\u00e3o com tran\u00e7a de malha aberta de fios sint\u00e9ticos: condutor de cobre nu classe 5 de constru\u00e7\u00e3o m\u00f3vel, blindagem semicondutora do condutor, isola\u00e7\u00e3o HEPR-MV micro-filtrada melhor que 3GI3, blindagem semicondutora da isola\u00e7\u00e3o, mantas e bainhas de PCP, tran\u00e7a anti-tor\u00e7\u00e3o. Como o TTX completa a fam\u00edlia TUNNELFLEX, o custo dimensional da tran\u00e7a frente ao TX, faixa de temperatura estendida at\u00e9 55\u00b0C, capacidade de corrente com derating em camadas de tambor, corrente de curto-circuito, for\u00e7as de tra\u00e7\u00e3o e tabelas completas por classe de tens\u00e3o.\">\n<meta name=\"keywords\" content=\"TUNNELFLEX-TTX,TUNNELFLEX-TX,RS-(N)TSCGEWOEU,cabo de tunelamento m\u00e9dia tens\u00e3o,prote\u00e7\u00e3o anti-tor\u00e7\u00e3o,tran\u00e7a de malha aberta,fios sint\u00e9ticos,bainha PCP,isola\u00e7\u00e3o HEPR-MV,blindagem semicondutora,cabo de m\u00e9dia tens\u00e3o flex\u00edvel,derating de tambor,corrente de curto-circuito,fator de corre\u00e7\u00e3o de temperatura,cabos Feichun\">\n<meta property=\"og:title\" content=\"O que \u00e9 o TUNNELFLEX-TTX: Cabo de M\u00e9dia Tens\u00e3o 3,6\/6 a 12\/20kV COM Prote\u00e7\u00e3o Anti-Tor\u00e7\u00e3o \u2014 An\u00e1lise de Engenharia Aprofundada\">\n<meta property=\"og:description\" content=\"An\u00e1lise de engenharia do TUNNELFLEX-TTX RS-(N)TSCGEWOEU, a vers\u00e3o de m\u00e9dia tens\u00e3o da fam\u00edlia TUNNELFLEX com tran\u00e7a anti-tor\u00e7\u00e3o de malha aberta de fios sint\u00e9ticos, isola\u00e7\u00e3o HEPR-MV e blindagens semicondutoras, para alimenta\u00e7\u00e3o de equipamentos m\u00f3veis com alto risco de dano mec\u00e2nico em tunelamento.\">\n<title>O que \u00e9 o TUNNELFLEX-TTX: Cabo de M\u00e9dia Tens\u00e3o 3,6\/6 a 12\/20 kV COM Prote\u00e7\u00e3o Anti-Tor\u00e7\u00e3o \u2014 An\u00e1lise de Engenharia Aprofundada<\/title>\n<style>\n:root{\n--bg:#0b111a; --panel:#141f2f; --panel2:#1b2a40; --line:#354a66;\n--text:#eef5ff; --muted:#b8c7da;\n--red:#ff3b30; --orange:#ff8a00; --yellow:#ffd54a; --blue:#2f8cff;\n--green:#00d084; --cyan:#4ecdc4; --purple:#b388ff;\n}\n*{box-sizing:border-box;margin:0;padding:0}\nbody{\nfont-family:\"Segoe UI\",\"Microsoft YaHei\",Arial,sans-serif;\nbackground:var(--bg); color:var(--text); line-height:1.75; overflow-x:hidden;\n}\n.container{max-width:1080px;margin:0 auto;padding:0 22px}\n.hero{\npadding:74px 20px; text-align:center; border-bottom:3px solid var(--red);\nbackground:\nradial-gradient(circle at 10% 12%,rgba(255,59,48,.30),transparent 34%),\nradial-gradient(circle at 88% 18%,rgba(179,136,255,.28),transparent 34%),\nradial-gradient(circle at 70% 86%,rgba(47,140,255,.22),transparent 38%),\nlinear-gradient(135deg,#0a0709 0%,#1b1320 46%,#101a31 100%);\n}\n.badges{display:flex;justify-content:center;gap:10px;flex-wrap:wrap;margin-bottom:26px}\n.badge{\npadding:9px 15px; border-radius:4px; font-size:11px; font-weight:800;\nletter-spacing:1px; text-transform:uppercase; border:1px solid rgba(255,255,255,.22);\n}\n.b1{background:var(--red)}\n.b2{background:var(--purple)}\n.b3{background:var(--blue)}\n.b4{background:var(--green);color:#071018}\n.b5{background:var(--cyan);color:#071018}\nh1{\nmax-width:1040px; margin:0 auto 20px;\nfont-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\nfont-size:42px; line-height:1.15; text-shadow:0 3px 14px rgba(0,0,0,.4);\n}\n.hero p{max-width:980px; margin:0 auto; color:rgba(255,255,255,.88); font-size:16px}\n.meta{\ndisplay:flex; justify-content:center; gap:16px; flex-wrap:wrap;\nmargin-top:28px; color:rgba(255,255,255,.78); font-size:12px;\n}\n.cards{\ndisplay:grid; grid-template-columns:repeat(auto-fit,minmax(240px,1fr));\ngap:20px; margin:48px 0;\n}\n.card{\nbackground:var(--panel); border:1px solid var(--line);\nborder-left:6px solid var(--red); border-radius:7px; padding:22px;\n}\n.card:nth-child(2){border-left-color:var(--purple)}\n.card:nth-child(3){border-left-color:var(--blue)}\n.card:nth-child(4){border-left-color:var(--green)}\n.card:nth-child(5){border-left-color:var(--yellow)}\n.card:nth-child(6){border-left-color:var(--cyan)}\n.label{\nfont-size:11px; color:var(--muted); text-transform:uppercase;\nletter-spacing:.8px; font-weight:800; margin-bottom:8px;\n}\n.value{\nfont-family:Georgia,\"Times New Roman\",serif; font-size:30px;\nfont-weight:800; color:var(--red); line-height:1.1;\n}\n.card:nth-child(2) .value{color:var(--purple)}\n.card:nth-child(3) .value{color:var(--blue)}\n.card:nth-child(4) .value{color:var(--green)}\n.card:nth-child(5) .value{color:var(--yellow)}\n.card:nth-child(6) .value{color:var(--cyan)}\n.unit{font-size:12px;color:var(--muted);margin-top:8px}\nmain{padding:12px 0 60px}\nh2{\nfont-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\nfont-size:34px; color:var(--red); line-height:1.25;\nmargin:56px 0 22px; padding-bottom:15px; border-bottom:3px solid var(--orange);\n}\nh3{\nfont-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\nfont-size:25px; color:var(--green); margin:38px 0 16px; line-height:1.32;\n}\nh4{\nfont-size:15px; color:var(--red); margin:24px 0 12px;\ntext-transform:uppercase; letter-spacing:.7px;\n}\np,li{color:var(--muted);font-size:15px}\np{margin:0 0 20px}\nul,ol{margin:18px 0 26px 28px}\nli{margin-bottom:10px}\nstrong{color:var(--orange)}\na{color:var(--cyan);text-decoration:none}\na:hover{text-decoration:underline}\n.divider{display:flex; align-items:center; gap:16px; margin:58px 0 12px}\n.divider span:first-child{\nbackground:var(--red); color:#fff; padding:7px 15px; border-radius:4px;\nfont-size:11px; font-weight:800; letter-spacing:1px; text-transform:uppercase;\n}\n.divider hr{flex:1;border:none;border-top:1px solid var(--line)}\n.divider .caption{color:var(--muted);font-size:13px}\n.note{\nbackground:linear-gradient(120deg,rgba(255,59,48,.14),rgba(179,136,255,.12));\nborder-left:6px solid var(--red); border-right:2px solid var(--purple);\npadding:24px; border-radius:7px; margin:28px 0;\n}\n.success{\nbackground:linear-gradient(135deg,#7a1410,#ff3b30); color:#fff;\nborder-radius:8px; padding:25px; margin:30px 0; box-shadow:0 8px 28px rgba(255,59,48,.22);\n}\n.success p{color:rgba(255,255,255,.92)}\n.table-scroll{\nwidth:100%; overflow-x:auto; overflow-y:hidden; -webkit-overflow-scrolling:touch;\nmargin:30px 0; border:1px solid var(--line); border-radius:7px; background:var(--panel);\n}\n.table-scroll table{\nwidth:max-content; min-width:1100px; border-collapse:collapse; margin:0;\nborder:none; display:table; font-size:13px;\n}\n.table-scroll.wide table{min-width:1500px}\n.table-scroll.medium table{min-width:1250px}\n.table-scroll th{\nbackground:#080f18; color:var(--red); font-size:12px; text-align:left;\npadding:12px; border-bottom:2px solid var(--line); white-space:nowrap;\n}\n.table-scroll td{\npadding:12px; border-bottom:1px solid var(--line); color:var(--muted);\nvertical-align:top; white-space:nowrap;\n}\n.table-scroll tr:hover td{background:rgba(255,59,48,.06)}\n.table-scroll::-webkit-scrollbar{height:10px}\n.table-scroll::-webkit-scrollbar-track{background:#080f18}\n.table-scroll::-webkit-scrollbar-thumb{background:var(--red);border-radius:10px}\n.layer{\nbackground:var(--panel); border:1px solid var(--line);\nborder-left:5px solid var(--red); padding:18px 20px; border-radius:6px; margin:16px 0;\n}\n.layer:nth-of-type(2n){border-left-color:var(--purple)}\n.layer-title{font-weight:800; color:var(--text); font-size:16px; margin-bottom:7px}\n.layer-text{color:var(--muted);font-size:13px}\n.formula{\nbackground:#080f18; border:1px solid var(--line); border-left:5px solid var(--purple);\nborder-radius:7px; padding:18px 20px; margin:22px 0; color:var(--muted);\nfont-family:Consolas,Monaco,monospace; font-size:13px; overflow-x:auto;\n}\n.qa{\nbackground:var(--panel2); border:1px solid var(--line); border-left:5px solid var(--green);\nborder-radius:7px; padding:22px; margin:24px 0;\n}\n.qa h4{margin-top:0;color:var(--green)}\nfooter{\nbackground:#070c13; border-top:3px solid var(--red); padding:48px 20px; margin-top:40px;\n}\nfooter h4{\nfont-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\nfont-size:24px; text-transform:none; letter-spacing:0; color:var(--red);\n}\n.contact{\nbackground:var(--panel); border:1px solid var(--line); border-left:5px solid var(--red);\nborder-radius:7px; padding:20px; margin:22px 0; color:var(--muted);\n}\n.docid{\ntext-align:center; color:#72849a; font-size:11px; margin-top:28px;\npadding-top:22px; border-top:1px solid var(--line);\n}\n@media(max-width:640px){\nh1{font-size:31px} h2{font-size:27px} h3{font-size:22px}\n.hero{padding:48px 16px} .value{font-size:27px}\n.table-scroll table{min-width:1150px}\n.table-scroll.wide table{min-width:1550px}\n}\n<\/style>\n<\/head>\n<body>\n<section class=\"hero\">\n<div class=\"container\">\n<div class=\"badges\">\n<span class=\"badge b1\">TUNNELFLEX-TTX<\/span>\n<span class=\"badge b2\">COM ANTI-TOR\u00c7\u00c3O<\/span>\n<span class=\"badge b3\">RS-(N)TSCGEWOEU<\/span>\n<span class=\"badge b4\">3,6\/6 \u2192 12\/20 kV<\/span>\n<span class=\"badge b5\">Tran\u00e7a de Malha Aberta<\/span>\n<\/div>\n<h1>O que \u00e9 o TUNNELFLEX-TTX: An\u00e1lise de Engenharia Aprofundada do Cabo de M\u00e9dia Tens\u00e3o 3,6\/6 a 12\/20 kV COM Prote\u00e7\u00e3o Anti-Tor\u00e7\u00e3o<\/h1>\n<p>O TUNNELFLEX-TTX RS-(N)TSCGEWOEU \u00e9 a vers\u00e3o de m\u00e9dia tens\u00e3o da fam\u00edlia TUNNELFLEX equipada com prote\u00e7\u00e3o anti-tor\u00e7\u00e3o \u2014 uma tran\u00e7a de malha aberta de fios sint\u00e9ticos aplicada entre a manta interna e a bainha externa de PCP. Ele alimenta equipamentos m\u00f3veis com alto risco de dano mec\u00e2nico em tunelamento, nas mesmas quatro classes de tens\u00e3o do TUNNELFLEX-TX (3,6\/6 a 12\/20 kV), mas para sistemas em que o cabo n\u00e3o \u00e9 apenas defletido em um plano, e sim torcido em torno do pr\u00f3prio eixo durante o servi\u00e7o. O TTX completa a fam\u00edlia: ele est\u00e1 para o TX assim como o R\/PUR est\u00e1 para o PUR na baixa tens\u00e3o \u2014 a mesma constru\u00e7\u00e3o el\u00e9trica, acrescida do elemento que absorve o esfor\u00e7o torcional.<\/p>\n<div class=\"meta\">\n<span>\u2713 M\u00e9dia tens\u00e3o: 3,6\/6 a 12\/20 kV<\/span>\n<span>\u2713 Tran\u00e7a anti-tor\u00e7\u00e3o de fios sint\u00e9ticos<\/span>\n<span>\u2713 HEPR-MV + duas blindagens semicondutoras<\/span>\n<span>\u2713 Bainhas de PCP, externa vermelha<\/span>\n<span>\u2713 Faixa de temperatura estendida at\u00e9 55\u00b0C<\/span>\n<\/div>\n<\/div>\n<\/section>\n\n<div class=\"container\">\n<div class=\"cards\">\n<div class=\"card\"><div class=\"label\">Faixa de Tens\u00e3o<\/div><div class=\"value\">3,6\/6\u219212\/20<\/div><div class=\"unit\">Quatro classes de m\u00e9dia tens\u00e3o (24 kV Um m\u00e1x.)<\/div><\/div>\n<div class=\"card\"><div class=\"label\">Prote\u00e7\u00e3o Anti-Tor\u00e7\u00e3o<\/div><div class=\"value\">Tran\u00e7a<\/div><div class=\"unit\">Malha aberta de fios sint\u00e9ticos<\/div><\/div>\n<div class=\"card\"><div class=\"label\">Tens\u00e3o de Ensaio M\u00e1x.<\/div><div class=\"value\">29kV<\/div><div class=\"unit\">Classe 12\/20 kV<\/div><\/div>\n<div class=\"card\"><div class=\"label\">Curto-Circuito M\u00e1x.<\/div><div class=\"value\">34,3kA<\/div><div class=\"unit\">Condutor 3&#215;240 (90\u2192250\u00b0C)<\/div><\/div>\n<div class=\"card\"><div class=\"label\">Corre\u00e7\u00e3o de Temp.<\/div><div class=\"value\">at\u00e9 55\u00b0C<\/div><div class=\"unit\">K = 0,71 \u2014 uma classe al\u00e9m do TX<\/div><\/div>\n<div class=\"card\"><div class=\"label\">Temp. do Condutor<\/div><div class=\"value\">90\u00b0C<\/div><div class=\"unit\">Regime cont\u00ednuo<\/div><\/div>\n<\/div>\n\n<main>\n\n<div class=\"divider\"><span>I<\/span><hr><span class=\"caption\">O quadrante que faltava<\/span><\/div>\n<h2>1. O que \u00e9 o TUNNELFLEX-TTX e Como Ele Completa a Fam\u00edlia<\/h2>\n<p>A fam\u00edlia TUNNELFLEX organiza-se em torno de duas perguntas independentes: qual \u00e9 a tens\u00e3o do sistema, e o cabo ser\u00e1 torcido em servi\u00e7o. Cruzando essas duas perguntas, surge uma matriz de quatro quadrantes \u2014 e o <strong>TUNNELFLEX-TTX<\/strong> \u00e9 precisamente o quarto: m\u00e9dia tens\u00e3o, com prote\u00e7\u00e3o anti-tor\u00e7\u00e3o. Ele combina o sistema el\u00e9trico de m\u00e9dia tens\u00e3o do TX (isola\u00e7\u00e3o HEPR-MV e blindagens semicondutoras) com a filosofia anti-tor\u00e7\u00e3o do R\/PUR (uma malha sint\u00e9tica que absorve a rota\u00e7\u00e3o).<\/p>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Quadrante<\/th><th>Baixa tens\u00e3o (0,6\/1 kV)<\/th><th>M\u00e9dia tens\u00e3o (3,6\/6 a 12\/20 kV)<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>SEM anti-tor\u00e7\u00e3o (deflex\u00e3o em um plano)<\/td><td>TUNNELFLEX-PUR<\/td><td>TUNNELFLEX-TX<\/td><\/tr>\n<tr><td>COM anti-tor\u00e7\u00e3o (tolera tor\u00e7\u00e3o)<\/td><td>TUNNELFLEX-R\/PUR<\/td><td><strong>TUNNELFLEX-TTX<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"note\">\n<h4>Tese t\u00e9cnica<\/h4>\n<p><strong>Argumento de engenharia:<\/strong> o TTX prova que a fam\u00edlia TUNNELFLEX \u00e9 uma plataforma de dois eixos ortogonais, n\u00e3o uma simples lista de produtos. A tens\u00e3o e o modo de movimento s\u00e3o vari\u00e1veis independentes: pode-se ter m\u00e9dia tens\u00e3o com deflex\u00e3o em um plano (TX) ou m\u00e9dia tens\u00e3o com tor\u00e7\u00e3o (TTX), exatamente como na baixa tens\u00e3o. Reconhecer isso muda a l\u00f3gica de sele\u00e7\u00e3o \u2014 n\u00e3o se escolhe &#8220;o cabo de m\u00e9dia tens\u00e3o&#8221; e depois se torce por que n\u00e3o, escolhe-se o cruzamento correto das duas perguntas. Usar um TX onde o sistema imp\u00f5e tor\u00e7\u00e3o leva \u00e0 falha prematura; usar um TTX onde s\u00f3 h\u00e1 deflex\u00e3o em um plano \u00e9 pagar peso, di\u00e2metro e custo por uma prote\u00e7\u00e3o que n\u00e3o trabalha.<\/p>\n<\/div>\n\n<div class=\"divider\"><span>II<\/span><hr><span class=\"caption\">A tran\u00e7a anti-tor\u00e7\u00e3o<\/span><\/div>\n<h2>2. A Tran\u00e7a de Malha Aberta de Fios Sint\u00e9ticos: o Elemento que Define o TTX<\/h2>\n<p>A \u00fanica diferen\u00e7a construtiva entre o TUNNELFLEX-TX e o TUNNELFLEX-TTX \u00e9 a inclus\u00e3o, neste \u00faltimo, de uma <strong>tran\u00e7a de malha aberta de fios sint\u00e9ticos<\/strong> (anti-twisting braid, open mesh of synthetic yarns), aplicada sobre a manta interna de PCP e sob a bainha externa de PCP. \u00c9 o equivalente, em m\u00e9dia tens\u00e3o, da malha sint\u00e9tica do R\/PUR \u2014 mas aqui ela protege um n\u00facleo muito mais sofisticado, com blindagens semicondutoras e isola\u00e7\u00e3o HEPR-MV que n\u00e3o toleram a desorganiza\u00e7\u00e3o que a tor\u00e7\u00e3o descontrolada provocaria.<\/p>\n<p>Em um cabo de m\u00e9dia tens\u00e3o, a tor\u00e7\u00e3o acumulada n\u00e3o \u00e9 apenas um problema mec\u00e2nico: ela tensiona as interfaces entre a isola\u00e7\u00e3o e as camadas semicondutoras extrudadas, podendo criar microvazios onde o campo el\u00e9trico iniciaria descargas parciais. Proteger o n\u00facleo de MT contra tor\u00e7\u00e3o \u00e9, portanto, proteger tamb\u00e9m o sistema de controle de campo do qual depende a vida do cabo. A tran\u00e7a de malha aberta restringe a rota\u00e7\u00e3o do conjunto sem enrijec\u00ea-lo, mantendo a flexibilidade que o servi\u00e7o m\u00f3vel exige.<\/p>\n<div class=\"formula\">\nEscolha TX vs TTX (m\u00e9dia tens\u00e3o) =\nDeflex\u00e3o em UM plano, sem rota\u00e7\u00e3o \u2192 TUNNELFLEX-TX\nTor\u00e7\u00e3o \/ rota\u00e7\u00e3o do cabo em servi\u00e7o \u2192 TUNNELFLEX-TTX (tran\u00e7a de malha aberta)\n<\/div>\n<div class=\"note\">\n<h4>Por que &#8220;malha aberta&#8221;, e por que fios sint\u00e9ticos<\/h4>\n<p><strong>Argumento de engenharia:<\/strong> dois adjetivos da folha de dados carregam decis\u00f5es de projeto. &#8220;Malha aberta&#8221; significa que a tran\u00e7a n\u00e3o envolve o cabo como uma capa fechada, mas como uma rede que deixa v\u00e3os \u2014 isso preserva a flexibilidade na flex\u00e3o e evita aprisionar calor, mantendo o caminho de dissipa\u00e7\u00e3o t\u00e9rmica do n\u00facleo. &#8220;Fios sint\u00e9ticos&#8221; indica refor\u00e7o t\u00eaxtil de alta resist\u00eancia \u00e0 tra\u00e7\u00e3o, e n\u00e3o armadura met\u00e1lica: o t\u00eaxtil resiste ao cisalhamento torcional sem o peso, a rigidez e os problemas de continuidade el\u00e9trica que uma tran\u00e7a met\u00e1lica traria a um cabo m\u00f3vel de m\u00e9dia tens\u00e3o. A tran\u00e7a trabalha como um exoesqueleto t\u00eaxtil que deixa o cabo dobrar mas n\u00e3o o deixa girar livremente \u2014 protegendo as interfaces semicondutoras sem comprometer flex\u00e3o nem dissipa\u00e7\u00e3o.<\/p>\n<\/div>\n\n<div class=\"divider\"><span>III<\/span><hr><span class=\"caption\">Constru\u00e7\u00e3o camada a camada<\/span><\/div>\n<h2>3. Constru\u00e7\u00e3o do TUNNELFLEX-TTX, da Alma \u00e0 Bainha<\/h2>\n<p>O TTX herda integralmente a arquitetura el\u00e9trica de m\u00e9dia tens\u00e3o do TX, acrescentando a tran\u00e7a anti-tor\u00e7\u00e3o entre as duas camadas de PCP. A sequ\u00eancia completa \u00e9 a seguinte.<\/p>\n\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 1 \u2014 Condutores de fase: cobre nu flex\u00edvel classe 5, constru\u00e7\u00e3o especial m\u00f3vel<\/div>\n<div class=\"layer-text\">Cobre nu, classe 5 conforme a DIN VDE 0295, com constru\u00e7\u00e3o especial para servi\u00e7o m\u00f3vel. O tran\u00e7amento fino \u00e9 a base da flexibilidade e da vida em flex\u00e3o repetida sob m\u00e9dia tens\u00e3o.<\/div>\n<\/div>\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 2 \u2014 Blindagem do condutor: camada semicondutora extrudada<\/div>\n<div class=\"layer-text\">Camada semicondutora extrudada de composto especial sobre cada condutor, que alisa a superf\u00edcie el\u00e9trica do feixe tran\u00e7ado e elimina os picos de campo entre os fios \u2014 origem das descargas parciais em m\u00e9dia tens\u00e3o.<\/div>\n<\/div>\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 3 \u2014 Isola\u00e7\u00e3o das fases: HEPR-MV micro-filtrado, melhor que 3GI3<\/div>\n<div class=\"layer-text\">Borracha de etileno-propileno de dureza m\u00e9dia para m\u00e9dia tens\u00e3o (HEPR-MV), composto especial micro-filtrado declarado superior ao grau 3GI3. Combina a elasticidade do servi\u00e7o m\u00f3vel com o desempenho diel\u00e9trico de MT.<\/div>\n<\/div>\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 4 \u2014 Blindagem da isola\u00e7\u00e3o (core screen): camada semicondutora extrudada<\/div>\n<div class=\"layer-text\">Segunda camada semicondutora extrudada sobre a isola\u00e7\u00e3o, que confina o campo el\u00e9trico dentro de cada n\u00facleo e cria o campo radial uniforme \u2014 o cora\u00e7\u00e3o do controle de campo em cabos de m\u00e9dia tens\u00e3o.<\/div>\n<\/div>\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 5 \u2014 Condutores de terra com cobertura semicondutora<\/div>\n<div class=\"layer-text\">Terras em cobre nu flex\u00edvel classe 5 (DIN VDE 0295), com cobertura semicondutora extrudada, dispostos nos interst\u00edcios entre as fases, participando do sistema de campo e do retorno de terra.<\/div>\n<\/div>\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 6 \u2014 Forma\u00e7\u00e3o e manta interna: fases cabeadas + PCP especial<\/div>\n<div class=\"layer-text\">As fases blindadas s\u00e3o reunidas com os terras nos interst\u00edcios; uma manta interna (inner sheath) de PCP especial trava a geometria do conjunto sob flex\u00e3o repetida.<\/div>\n<\/div>\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 7 \u2014 Tran\u00e7a anti-tor\u00e7\u00e3o: malha aberta de fios sint\u00e9ticos (exclusiva do TTX)<\/div>\n<div class=\"layer-text\">O elemento que define o TTX: uma tran\u00e7a em malha aberta de fios sint\u00e9ticos, aplicada sobre a manta interna. Absorve o esfor\u00e7o torcional e protege as interfaces semicondutoras da desorganiza\u00e7\u00e3o provocada pela rota\u00e7\u00e3o, sem enrijecer o cabo nem bloquear a dissipa\u00e7\u00e3o de calor.<\/div>\n<\/div>\n<div class=\"layer\">\n<div class=\"layer-title\">Camada 8 \u2014 Bainha externa: PCP de composto especial, vermelho<\/div>\n<div class=\"layer-text\">Bainha externa de policloropreno especial, na cor vermelha de advert\u00eancia de m\u00e9dia tens\u00e3o, resistente a \u00f3leo, oz\u00f4nio e abras\u00e3o \u2014 o elast\u00f4mero tradicional para cabos m\u00f3veis de MT.<\/div>\n<\/div>\n\n<div class=\"divider\"><span>IV<\/span><hr><span class=\"caption\">O custo da tran\u00e7a<\/span><\/div>\n<h2>4. O Custo Dimensional da Tran\u00e7a: TTX frente ao TX<\/h2>\n<p>A tran\u00e7a de malha aberta n\u00e3o \u00e9 gratuita: ela acrescenta di\u00e2metro e peso ao cabo. Comparando bitola a bitola, na mesma classe de tens\u00e3o, o TTX \u00e9 sistematicamente um pouco mais grosso e mais pesado que o TX. A tabela a seguir ilustra a penalidade na classe 3,6\/6 (7,2) kV.<\/p>\n<div class=\"table-scroll wide\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o (3,6\/6 kV)<\/th><th>OD m\u00e1x. TX mm<\/th><th>OD m\u00e1x. TTX mm<\/th><th>\u0394 di\u00e2metro mm<\/th><th>Peso TX kg\/km<\/th><th>Peso TTX kg\/km<\/th><th>\u0394 peso kg\/km<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25+3&#215;25\/3<\/td><td>41,6<\/td><td>42,4<\/td><td>+0,8<\/td><td>2420<\/td><td>2520<\/td><td>+100<\/td><\/tr>\n<tr><td>3&#215;35+3&#215;25\/3<\/td><td>44,2<\/td><td>45,0<\/td><td>+0,8<\/td><td>2940<\/td><td>3040<\/td><td>+100<\/td><\/tr>\n<tr><td>3&#215;50+3&#215;25\/3<\/td><td>47,0<\/td><td>47,8<\/td><td>+0,8<\/td><td>3470<\/td><td>3570<\/td><td>+100<\/td><\/tr>\n<tr><td>3&#215;70+3&#215;25\/3<\/td><td>51,1<\/td><td>52,4<\/td><td>+1,3<\/td><td>4370<\/td><td>4490<\/td><td>+120<\/td><\/tr>\n<tr><td>3&#215;95+3&#215;50\/3<\/td><td>55,5<\/td><td>56,3<\/td><td>+0,8<\/td><td>5370<\/td><td>5490<\/td><td>+120<\/td><\/tr>\n<tr><td>3&#215;120+3&#215;70\/3<\/td><td>59,8<\/td><td>60,6<\/td><td>+0,8<\/td><td>6730<\/td><td>6880<\/td><td>+150<\/td><\/tr>\n<tr><td>3&#215;150+3&#215;70\/3<\/td><td>64,3<\/td><td>65,1<\/td><td>+0,8<\/td><td>7750<\/td><td>7910<\/td><td>+160<\/td><\/tr>\n<tr><td>3&#215;185+3&#215;95\/3<\/td><td>67,3<\/td><td>68,1<\/td><td>+0,8<\/td><td>9180<\/td><td>9340<\/td><td>+160<\/td><\/tr>\n<tr><td>3&#215;240+3&#215;120\/3<\/td><td>75,7<\/td><td>76,5<\/td><td>+0,8<\/td><td>11970<\/td><td>12150<\/td><td>+180<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"note\">\n<h4>O que a penalidade significa na pr\u00e1tica<\/h4>\n<p><strong>Argumento de engenharia:<\/strong> a tran\u00e7a custa tipicamente cerca de 0,8 mm de di\u00e2metro e de 100 a 180 kg\/km de peso, sem alterar nada da capacidade el\u00e9trica \u2014 a corrente, o curto-circuito e a tra\u00e7\u00e3o publicados s\u00e3o id\u00eanticos aos do TX. Essa \u00e9 a tradu\u00e7\u00e3o num\u00e9rica do princ\u00edpio de sele\u00e7\u00e3o: a prote\u00e7\u00e3o anti-tor\u00e7\u00e3o tem um pre\u00e7o dimensional e de peso, justificado apenas quando o sistema realmente torce o cabo. Em projeto, o di\u00e2metro maior do TTX tamb\u00e9m consome um pouco mais de tambor por volta e exige reverificar o raio de curvatura m\u00ednimo (10\u00d7OD em tambor) sobre o novo OD. Onde s\u00f3 h\u00e1 deflex\u00e3o em um plano, o TX entrega a mesma performance el\u00e9trica com menos massa e menor di\u00e2metro.<\/p>\n<\/div>\n\n<div class=\"divider\"><span>V<\/span><hr><span class=\"caption\">Par\u00e2metros el\u00e9tricos<\/span><\/div>\n<h2>5. Par\u00e2metros El\u00e9tricos por Classe de Tens\u00e3o<\/h2>\n<p>O TTX cobre as mesmas quatro classes de m\u00e9dia tens\u00e3o do TX, com tens\u00e3o m\u00e1xima de opera\u00e7\u00e3o e tens\u00e3o de ensaio id\u00eanticas. A temperatura m\u00e1xima do condutor \u00e9 de 90\u00b0C.<\/p>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Tens\u00e3o nominal Uo\/U (Um)<\/th><th>M\u00e1x. opera\u00e7\u00e3o kV<\/th><th>Tens\u00e3o de ensaio kV<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3,6\/6 (7,2) kV<\/td><td>5,4<\/td><td>11<\/td><\/tr>\n<tr><td>6\/10 (12) kV<\/td><td>12<\/td><td>17<\/td><\/tr>\n<tr><td>8,7\/15 (18) kV<\/td><td>18<\/td><td>24<\/td><\/tr>\n<tr><td>12\/20 (24) kV<\/td><td>24<\/td><td>29<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3>5.1 Fatores de corre\u00e7\u00e3o para temperatura ambiente \u2014 agora at\u00e9 55\u00b0C<\/h3>\n<p>Aqui surge uma diferen\u00e7a sutil mas concreta em rela\u00e7\u00e3o ao TX: a tabela de corre\u00e7\u00e3o do TTX estende-se a 55\u00b0C, com fator K de 0,71, uma classe de temperatura al\u00e9m do TX (que parava em 50\u00b0C \/ 0,77).<\/p>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr><th>Temperatura ambiente \u00b0C<\/th><th>20<\/th><th>25<\/th><th>35<\/th><th>40<\/th><th>45<\/th><th>50<\/th><th>55<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Fator K<\/td><td>1,10<\/td><td>1,05<\/td><td>0,95<\/td><td>0,89<\/td><td>0,84<\/td><td>0,77<\/td><td>0,71<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"note\">\n<h4>O significado do degrau extra de 55\u00b0C<\/h4>\n<p><strong>Argumento de engenharia:<\/strong> a faixa de corre\u00e7\u00e3o estendida a 55\u00b0C (K = 0,71) reconhece um fato de campo: galerias profundas e frentes de escava\u00e7\u00e3o de t\u00fanel podem ser ambientes quentes, e o cabo precisa de um fator de derating v\u00e1lido nessa condi\u00e7\u00e3o. A 55\u00b0C, a capacidade de corrente cai para 71% do valor de cat\u00e1logo (referido a 30\u00b0C). Combinada com o derating de enrolamento em tambor \u2014 que por si s\u00f3 corta cerca de 50% \u2014, a corre\u00e7\u00e3o de temperatura mostra por que o cabo estendido nunca deve ser usado como base de dimensionamento: um TTX a 55\u00b0C ambiente e enrolado em tr\u00eas camadas opera a uma fra\u00e7\u00e3o pequena da corrente que o n\u00famero de cat\u00e1logo sugere.<\/p>\n<\/div>\n\n<div class=\"divider\"><span>VI<\/span><hr><span class=\"caption\">Capacidade de corrente e derating de tambor<\/span><\/div>\n<h2>6. Capacidade de Corrente e o Derating Cr\u00edtico em Camadas de Tambor<\/h2>\n<p>A capacidade de corrente do TTX \u00e9 id\u00eantica \u00e0 do TX \u2014 a tran\u00e7a n\u00e3o altera a t\u00e9rmica do n\u00facleo de forma significativa. Os valores s\u00e3o publicados em quatro condi\u00e7\u00f5es: estendido e enrolado em uma, duas e tr\u00eas camadas. As classes 3,6\/6 e 6\/10 kV compartilham um conjunto de valores; as classes 8,7\/15 e 12\/20 kV t\u00eam valores ligeiramente superiores.<\/p>\n\n<h3>6.1 Capacidade de corrente \u2014 classes 3,6\/6 e 6\/10 kV<\/h3>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o<\/th><th>Estendido A<\/th><th>1 camada A<\/th><th>2 camadas A<\/th><th>3 camadas A<\/th><th>Redu\u00e7\u00e3o p\/ 3 camadas<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25<\/td><td>131<\/td><td>105<\/td><td>80<\/td><td>64<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;35<\/td><td>162<\/td><td>130<\/td><td>99<\/td><td>79<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;50<\/td><td>202<\/td><td>162<\/td><td>123<\/td><td>99<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;70<\/td><td>250<\/td><td>200<\/td><td>153<\/td><td>123<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;95<\/td><td>301<\/td><td>241<\/td><td>184<\/td><td>147<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;120<\/td><td>352<\/td><td>282<\/td><td>215<\/td><td>172<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;150<\/td><td>404<\/td><td>323<\/td><td>246<\/td><td>198<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;185<\/td><td>461<\/td><td>369<\/td><td>281<\/td><td>226<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;240<\/td><td>540<\/td><td>432<\/td><td>329<\/td><td>265<\/td><td>\u221251%<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3>6.2 Capacidade de corrente \u2014 classes 8,7\/15 e 12\/20 kV<\/h3>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o<\/th><th>Estendido A<\/th><th>1 camada A<\/th><th>2 camadas A<\/th><th>3 camadas A<\/th><th>Redu\u00e7\u00e3o p\/ 3 camadas<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25<\/td><td>139<\/td><td>111<\/td><td>85<\/td><td>68<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;35<\/td><td>172<\/td><td>138<\/td><td>105<\/td><td>84<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;50<\/td><td>215<\/td><td>172<\/td><td>131<\/td><td>105<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;70<\/td><td>265<\/td><td>212<\/td><td>162<\/td><td>130<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;95<\/td><td>319<\/td><td>255<\/td><td>195<\/td><td>156<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;120<\/td><td>371<\/td><td>297<\/td><td>226<\/td><td>182<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;150<\/td><td>428<\/td><td>342<\/td><td>261<\/td><td>210<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;185<\/td><td>488<\/td><td>390<\/td><td>298<\/td><td>239<\/td><td>\u221251%<\/td><\/tr>\n<tr><td>3&#215;240<\/td><td>574<\/td><td>459<\/td><td>350<\/td><td>281<\/td><td>\u221251%<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"formula\">\nCorrente Admiss\u00edvel Real = Corrente da Condi\u00e7\u00e3o de Enrolamento Real\n\u00d7 Fator K de Temperatura (1,10 a 20\u00b0C &#8230; 0,77 a 50\u00b0C &#8230; 0,71 a 55\u00b0C)\n<\/div>\n\n<div class=\"divider\"><span>VII<\/span><hr><span class=\"caption\">Curto-circuito<\/span><\/div>\n<h2>7. Suportabilidade a Curto-Circuito (90\u00b0C \u2192 250\u00b0C)<\/h2>\n<p>Por depender apenas da se\u00e7\u00e3o e do material do condutor, a corrente de curto-circuito admiss\u00edvel \u00e9 id\u00eantica \u00e0 do TX e igual em todas as classes de tens\u00e3o.<\/p>\n<div class=\"table-scroll\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o de fase<\/th><th>Corrente de curto-circuito kA (90\u2192250\u00b0C)<\/th><th>Densidade aproximada<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25<\/td><td>3,6<\/td><td>\u2248 144 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;35<\/td><td>5,0<\/td><td>\u2248 143 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;50<\/td><td>7,2<\/td><td>\u2248 144 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;70<\/td><td>10,0<\/td><td>\u2248 143 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;95<\/td><td>13,6<\/td><td>\u2248 143 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;120<\/td><td>17,2<\/td><td>\u2248 143 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;150<\/td><td>21,5<\/td><td>\u2248 143 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;185<\/td><td>26,5<\/td><td>\u2248 143 A\/mm\u00b2<\/td><\/tr>\n<tr><td>3&#215;240<\/td><td>34,3<\/td><td>\u2248 143 A\/mm\u00b2<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"note\">\n<h4>Como ler o valor de curto-circuito<\/h4>\n<p><strong>Argumento de engenharia:<\/strong> os valores correspondem \u00e0 energia que o condutor suporta de 90\u00b0C (temperatura m\u00e1xima em regime) at\u00e9 250\u00b0C (limite t\u00e9rmico de curta dura\u00e7\u00e3o), tipicamente referidos a 1 segundo. A densidade praticamente constante de cerca de 143 A\/mm\u00b2 \u00e9 a assinatura do c\u00e1lculo adiab\u00e1tico para condutor de cobre nesse intervalo. Em projeto, a corrente admiss\u00edvel para o tempo de atua\u00e7\u00e3o real da prote\u00e7\u00e3o escala com o inverso da raiz do tempo: maior para uma falta eliminada em 0,5 s, menor para 2 s. Converta o valor publicado para o tempo real da prote\u00e7\u00e3o antes de compar\u00e1-lo \u00e0 corrente de curto-circuito presumida no ponto de instala\u00e7\u00e3o.<\/p>\n<\/div>\n\n<div class=\"divider\"><span>VIII<\/span><hr><span class=\"caption\">Par\u00e2metros mec\u00e2nicos<\/span><\/div>\n<h2>8. Par\u00e2metros Mec\u00e2nicos: Raio de Curvatura, Tra\u00e7\u00e3o e Temperatura<\/h2>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Par\u00e2metro<\/th><th>Valor (TTX)<\/th><th>Significado de engenharia<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Raio de curvatura, fixo<\/td><td>5 \u00d7 OD<\/td><td>Raio compacto para trechos est\u00e1ticos do lan\u00e7amento.<\/td><\/tr>\n<tr><td>Raio de curvatura, em tambor<\/td><td>10 \u00d7 OD<\/td><td>Verificar sobre o OD maior do TTX (tran\u00e7a inclusa).<\/td><\/tr>\n<tr><td>Tra\u00e7\u00e3o (publicada)<\/td><td>1500 N na 3&#215;25 = 20 N\/mm\u00b2<\/td><td>Referida \u00e0 se\u00e7\u00e3o total dos condutores de fase.<\/td><\/tr>\n<tr><td>Temperatura ambiente fixa (m\u00edn.)<\/td><td>\u221230\u00b0C<\/td><td>Para trechos est\u00e1ticos do lan\u00e7amento.<\/td><\/tr>\n<tr><td>Temperatura opera\u00e7\u00e3o flex\u00edvel (m\u00edn.)<\/td><td>\u221220\u00b0C<\/td><td>Limite de verifica\u00e7\u00e3o para movimento din\u00e2mico.<\/td><\/tr>\n<tr><td>Temperatura do condutor (m\u00e1x.)<\/td><td>+90\u00b0C<\/td><td>Regime cont\u00ednuo.<\/td><\/tr>\n<tr><td>Corre\u00e7\u00e3o de temperatura ambiente<\/td><td>at\u00e9 55\u00b0C (K = 0,71)<\/td><td>Faixa estendida em rela\u00e7\u00e3o ao TX.<\/td><\/tr>\n<tr><td>Modo de deflex\u00e3o<\/td><td>Flex\u00e3o + tor\u00e7\u00e3o<\/td><td>Habilitado pela tran\u00e7a de malha aberta.<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"note\">\n<h4>A regra de tra\u00e7\u00e3o lida nos n\u00fameros<\/h4>\n<p><strong>Argumento de engenharia:<\/strong> a tabela do TTX publica 1500 N de tra\u00e7\u00e3o para a bitola 3&#215;25 (75 mm\u00b2 de se\u00e7\u00e3o total de fase), o que corresponde a 20 N\/mm\u00b2 \u2014 a mesma regra do TX. Multiplicar a se\u00e7\u00e3o total de fase por 20 N\/mm\u00b2 fornece a tra\u00e7\u00e3o admiss\u00edvel de qualquer bitola, valor a ser confirmado na folha de dados emitida. Vale notar que a tran\u00e7a anti-tor\u00e7\u00e3o \u00e9 um elemento de resist\u00eancia \u00e0 tor\u00e7\u00e3o, n\u00e3o necessariamente de refor\u00e7o \u00e0 tra\u00e7\u00e3o axial: a for\u00e7a de puxamento deve continuar sendo aplicada pelos condutores (ou por uma malha\/olhal de tra\u00e7\u00e3o apropriado), respeitando o limite de 20 N\/mm\u00b2 sobre a se\u00e7\u00e3o de cobre de fase.<\/p>\n<\/div>\n\n<div class=\"divider\"><span>IX<\/span><hr><span class=\"caption\">Tabelas dimensionais completas<\/span><\/div>\n<h2>9. Faixa Dimensional do TUNNELFLEX-TTX por Classe de Tens\u00e3o<\/h2>\n<p>As quatro tabelas a seguir re\u00fanem, fielmente conforme a folha de dados, os dados dimensionais, de peso, de tra\u00e7\u00e3o e de curto-circuito do TTX para cada classe de m\u00e9dia tens\u00e3o.<\/p>\n\n<h3>9.1 Classe 3,6\/6 (7,2) kV<\/h3>\n<div class=\"table-scroll wide\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o<\/th><th>Di\u00e2m. fase mm<\/th><th>Di\u00e2m. terra mm<\/th><th>OD m\u00edn. mm<\/th><th>OD m\u00e1x. mm<\/th><th>Peso kg\/km<\/th><th>Tra\u00e7\u00e3o N<\/th><th>Curto kA<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25+3&#215;25\/3<\/td><td>6,6<\/td><td>4,0<\/td><td>39,4<\/td><td>42,4<\/td><td>2520<\/td><td>1500<\/td><td>3,6<\/td><\/tr>\n<tr><td>3&#215;35+3&#215;25\/3<\/td><td>8,0<\/td><td>4,0<\/td><td>42,0<\/td><td>45,0<\/td><td>3040<\/td><td>2100<\/td><td>5,0<\/td><\/tr>\n<tr><td>3&#215;50+3&#215;25\/3<\/td><td>9,3<\/td><td>4,0<\/td><td>44,8<\/td><td>47,8<\/td><td>3570<\/td><td>3000<\/td><td>7,2<\/td><\/tr>\n<tr><td>3&#215;70+3&#215;25\/3<\/td><td>11,2<\/td><td>4,9<\/td><td>48,4<\/td><td>52,4<\/td><td>4490<\/td><td>4200<\/td><td>10,0<\/td><\/tr>\n<tr><td>3&#215;95+3&#215;50\/3<\/td><td>13,0<\/td><td>5,4<\/td><td>52,3<\/td><td>56,3<\/td><td>5490<\/td><td>5700<\/td><td>13,6<\/td><\/tr>\n<tr><td>3&#215;120+3&#215;70\/3<\/td><td>15,0<\/td><td>6,6<\/td><td>56,6<\/td><td>60,6<\/td><td>6880<\/td><td>7200<\/td><td>17,2<\/td><\/tr>\n<tr><td>3&#215;150+3&#215;70\/3<\/td><td>16,9<\/td><td>6,6<\/td><td>61,1<\/td><td>65,1<\/td><td>7910<\/td><td>9000<\/td><td>21,5<\/td><\/tr>\n<tr><td>3&#215;185+3&#215;95\/3<\/td><td>18,3<\/td><td>8,0<\/td><td>64,1<\/td><td>68,1<\/td><td>9340<\/td><td>11100<\/td><td>26,5<\/td><\/tr>\n<tr><td>3&#215;240+3&#215;120\/3<\/td><td>20,5<\/td><td>9,3<\/td><td>72,5<\/td><td>76,5<\/td><td>12150<\/td><td>14400<\/td><td>34,3<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3>9.2 Classe 6\/10 (12) kV<\/h3>\n<div class=\"table-scroll wide\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o<\/th><th>Di\u00e2m. fase mm<\/th><th>Di\u00e2m. terra mm<\/th><th>OD m\u00edn. mm<\/th><th>OD m\u00e1x. mm<\/th><th>Peso kg\/km<\/th><th>Tra\u00e7\u00e3o N<\/th><th>Curto kA<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25+3&#215;25\/3<\/td><td>6,6<\/td><td>4,0<\/td><td>41,1<\/td><td>44,1<\/td><td>2670<\/td><td>1500<\/td><td>3,6<\/td><\/tr>\n<tr><td>3&#215;35+3&#215;25\/3<\/td><td>8,0<\/td><td>4,0<\/td><td>43,8<\/td><td>46,8<\/td><td>3200<\/td><td>2100<\/td><td>5,0<\/td><\/tr>\n<tr><td>3&#215;50+3&#215;25\/3<\/td><td>9,3<\/td><td>4,0<\/td><td>46,6<\/td><td>49,6<\/td><td>3740<\/td><td>3000<\/td><td>7,2<\/td><\/tr>\n<tr><td>3&#215;70+3&#215;25\/3<\/td><td>11,2<\/td><td>4,9<\/td><td>50,2<\/td><td>54,2<\/td><td>4670<\/td><td>4200<\/td><td>10,0<\/td><\/tr>\n<tr><td>3&#215;95+3&#215;50\/3<\/td><td>13,0<\/td><td>5,4<\/td><td>54,0<\/td><td>58,0<\/td><td>5690<\/td><td>5700<\/td><td>13,6<\/td><\/tr>\n<tr><td>3&#215;120+3&#215;70\/3<\/td><td>15,0<\/td><td>6,6<\/td><td>58,3<\/td><td>62,3<\/td><td>7090<\/td><td>7200<\/td><td>17,2<\/td><\/tr>\n<tr><td>3&#215;150+3&#215;70\/3<\/td><td>16,9<\/td><td>6,6<\/td><td>62,8<\/td><td>66,8<\/td><td>8140<\/td><td>9000<\/td><td>21,5<\/td><\/tr>\n<tr><td>3&#215;185+3&#215;95\/3<\/td><td>18,3<\/td><td>8,0<\/td><td>65,9<\/td><td>69,9<\/td><td>9590<\/td><td>11100<\/td><td>26,5<\/td><\/tr>\n<tr><td>3&#215;240+3&#215;120\/3<\/td><td>20,5<\/td><td>9,3<\/td><td>73,7<\/td><td>77,7<\/td><td>12350<\/td><td>14400<\/td><td>34,3<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3>9.3 Classe 8,7\/15 (18) kV<\/h3>\n<div class=\"table-scroll wide\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o<\/th><th>Di\u00e2m. fase mm<\/th><th>Di\u00e2m. terra mm<\/th><th>OD m\u00edn. mm<\/th><th>OD m\u00e1x. mm<\/th><th>Peso kg\/km<\/th><th>Tra\u00e7\u00e3o N<\/th><th>Curto kA<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25+3&#215;25\/3<\/td><td>6,6<\/td><td>4,0<\/td><td>44,5<\/td><td>47,5<\/td><td>2990<\/td><td>1500<\/td><td>3,6<\/td><\/tr>\n<tr><td>3&#215;35+3&#215;25\/3<\/td><td>8,0<\/td><td>4,0<\/td><td>47,2<\/td><td>50,2<\/td><td>3540<\/td><td>2100<\/td><td>5,0<\/td><\/tr>\n<tr><td>3&#215;50+3&#215;25\/3<\/td><td>9,3<\/td><td>4,0<\/td><td>49,5<\/td><td>53,5<\/td><td>4110<\/td><td>3000<\/td><td>7,2<\/td><\/tr>\n<tr><td>3&#215;70+3&#215;25\/3<\/td><td>11,2<\/td><td>4,9<\/td><td>53,6<\/td><td>57,6<\/td><td>5070<\/td><td>4200<\/td><td>10,0<\/td><\/tr>\n<tr><td>3&#215;95+3&#215;50\/3<\/td><td>13,0<\/td><td>5,4<\/td><td>57,5<\/td><td>61,5<\/td><td>6130<\/td><td>5700<\/td><td>13,6<\/td><\/tr>\n<tr><td>3&#215;120+3&#215;70\/3<\/td><td>15,0<\/td><td>6,6<\/td><td>62,2<\/td><td>66,2<\/td><td>7600<\/td><td>7200<\/td><td>17,2<\/td><\/tr>\n<tr><td>3&#215;150+3&#215;70\/3<\/td><td>16,9<\/td><td>6,6<\/td><td>66,3<\/td><td>70,3<\/td><td>8620<\/td><td>9000<\/td><td>21,5<\/td><\/tr>\n<tr><td>3&#215;185+3&#215;95\/3<\/td><td>18,3<\/td><td>8,0<\/td><td>70,7<\/td><td>74,7<\/td><td>10320<\/td><td>11100<\/td><td>26,5<\/td><\/tr>\n<tr><td>3&#215;240+3&#215;120\/3<\/td><td>20,5<\/td><td>9,3<\/td><td>76,3<\/td><td>80,3<\/td><td>12770<\/td><td>14400<\/td><td>34,3<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3>9.4 Classe 12\/20 (24) kV<\/h3>\n<div class=\"table-scroll wide\">\n<table>\n<thead>\n<tr><th>Se\u00e7\u00e3o<\/th><th>Di\u00e2m. fase mm<\/th><th>Di\u00e2m. terra mm<\/th><th>OD m\u00edn. mm<\/th><th>OD m\u00e1x. mm<\/th><th>Peso kg\/km<\/th><th>Tra\u00e7\u00e3o N<\/th><th>Curto kA<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>3&#215;25+3&#215;25\/3<\/td><td>6,6<\/td><td>4,0<\/td><td>48,8<\/td><td>52,8<\/td><td>3480<\/td><td>1500<\/td><td>3,6<\/td><\/tr>\n<tr><td>3&#215;35+3&#215;25\/3<\/td><td>8,0<\/td><td>4,0<\/td><td>51,5<\/td><td>55,5<\/td><td>4060<\/td><td>2100<\/td><td>5,0<\/td><\/tr>\n<tr><td>3&#215;50+3&#215;25\/3<\/td><td>9,3<\/td><td>4,0<\/td><td>54,3<\/td><td>58,3<\/td><td>4650<\/td><td>3000<\/td><td>7,2<\/td><\/tr>\n<tr><td>3&#215;70+3&#215;25\/3<\/td><td>11,2<\/td><td>4,9<\/td><td>58,3<\/td><td>62,3<\/td><td>5670<\/td><td>4200<\/td><td>10,0<\/td><\/tr>\n<tr><td>3&#215;95+3&#215;50\/3<\/td><td>13,0<\/td><td>5,4<\/td><td>62,6<\/td><td>66,6<\/td><td>6810<\/td><td>5700<\/td><td>13,6<\/td><\/tr>\n<tr><td>3&#215;120+3&#215;70\/3<\/td><td>15,0<\/td><td>6,6<\/td><td>66,9<\/td><td>70,9<\/td><td>8260<\/td><td>7200<\/td><td>17,2<\/td><\/tr>\n<tr><td>3&#215;150+3&#215;70\/3<\/td><td>16,9<\/td><td>6,6<\/td><td>72,4<\/td><td>76,4<\/td><td>9560<\/td><td>9000<\/td><td>21,5<\/td><\/tr>\n<tr><td>3&#215;185+3&#215;95\/3<\/td><td>18,3<\/td><td>8,0<\/td><td>75,4<\/td><td>79,4<\/td><td>11050<\/td><td>11100<\/td><td>26,5<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Assim como no TX, a classe 12\/20 kV \u00e9 listada at\u00e9 a bitola 3&#215;185; para a 3&#215;240 nesta classe, a disponibilidade deve ser confirmada na folha de dados emitida.<\/p>\n\n<div class=\"divider\"><span>X<\/span><hr><span class=\"caption\">An\u00e1lise comparativa<\/span><\/div>\n<h2>10. An\u00e1lise Comparativa: TTX frente a TX e ao Resto da Fam\u00edlia<\/h2>\n\n<h3>10.1 TUNNELFLEX-TX vs. TUNNELFLEX-TTX<\/h3>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Crit\u00e9rio<\/th><th>TUNNELFLEX-TX<\/th><th>TUNNELFLEX-TTX<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Prote\u00e7\u00e3o anti-tor\u00e7\u00e3o<\/td><td>Ausente<\/td><td>Tran\u00e7a de malha aberta de fios sint\u00e9ticos<\/td><\/tr>\n<tr><td>Esfor\u00e7o admiss\u00edvel<\/td><td>Deflex\u00e3o em um plano<\/td><td>Flex\u00e3o + tor\u00e7\u00e3o<\/td><\/tr>\n<tr><td>Di\u00e2metro externo<\/td><td>Menor<\/td><td>\u2248 +0,8 mm<\/td><\/tr>\n<tr><td>Peso<\/td><td>Menor<\/td><td>\u2248 +100 a 180 kg\/km<\/td><\/tr>\n<tr><td>Faixa de corre\u00e7\u00e3o de temperatura<\/td><td>At\u00e9 50\u00b0C (K = 0,77)<\/td><td>At\u00e9 55\u00b0C (K = 0,71)<\/td><\/tr>\n<tr><td>Sistema el\u00e9trico (HEPR-MV, blindagens, PCP)<\/td><td>Id\u00eantico<\/td><td>Id\u00eantico<\/td><\/tr>\n<tr><td>Corrente \/ curto-circuito \/ tra\u00e7\u00e3o<\/td><td>Id\u00eanticos ao TTX<\/td><td>Id\u00eanticos ao TX<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<h3>10.2 A matriz completa da fam\u00edlia TUNNELFLEX<\/h3>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Variante<\/th><th>Tens\u00e3o<\/th><th>Anti-tor\u00e7\u00e3o<\/th><th>Isola\u00e7\u00e3o \/ bainha<\/th><th>Modo de movimento<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>TUNNELFLEX-PUR<\/td><td>0,6\/1 kV<\/td><td>N\u00e3o<\/td><td>XLPE \/ PUR amarelo<\/td><td>Um plano<\/td><\/tr>\n<tr><td>TUNNELFLEX-R\/PUR<\/td><td>0,6\/1 kV<\/td><td>Malha sint\u00e9tica<\/td><td>XLPE \/ PUR amarelo<\/td><td>Flex\u00e3o + tor\u00e7\u00e3o<\/td><\/tr>\n<tr><td>TUNNELFLEX-TX<\/td><td>3,6\/6 a 12\/20 kV<\/td><td>N\u00e3o<\/td><td>HEPR-MV \/ PCP vermelho<\/td><td>Um plano<\/td><\/tr>\n<tr><td>TUNNELFLEX-TTX<\/td><td>3,6\/6 a 12\/20 kV<\/td><td>Tran\u00e7a de malha aberta<\/td><td>HEPR-MV \/ PCP vermelho<\/td><td>Flex\u00e3o + tor\u00e7\u00e3o<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"note\">\n<h4>Contra-argumento honesto<\/h4>\n<p><strong>Argumento de engenharia:<\/strong> o TTX n\u00e3o deve ser a escolha padr\u00e3o de m\u00e9dia tens\u00e3o &#8220;por garantia&#8221;. A tran\u00e7a adiciona di\u00e2metro, peso e custo sem qualquer ganho el\u00e9trico, e em um sistema de pura deflex\u00e3o em um plano ela \u00e9 peso morto \u2014 o TX entrega a mesma performance com menos massa, ocupa menos tambor por volta e tem raio de curvatura mais favor\u00e1vel. A regra de sele\u00e7\u00e3o \u00e9, portanto, dupla e independente: a tens\u00e3o decide BT ou MT, e o modo de movimento decide com ou sem anti-tor\u00e7\u00e3o. O TTX \u00e9 a resposta certa apenas quando h\u00e1, comprovadamente, tor\u00e7\u00e3o do cabo em servi\u00e7o. Vale ainda lembrar que toda a fam\u00edlia compartilha o limite de \u221220\u00b0C em opera\u00e7\u00e3o flex\u00edvel, que pode ser insuficiente em clima extremo, e que a termina\u00e7\u00e3o de qualquer vers\u00e3o de MT (TX ou TTX) exige o preparo especializado dos semicondutores e do al\u00edvio de campo.<\/p>\n<\/div>\n\n<div class=\"divider\"><span>XI<\/span><hr><span class=\"caption\">Estrutura de sele\u00e7\u00e3o<\/span><\/div>\n<h2>11. Como Selecionar o TUNNELFLEX-TTX<\/h2>\n<div class=\"table-scroll medium\">\n<table>\n<thead>\n<tr><th>Dimens\u00e3o de sele\u00e7\u00e3o<\/th><th>Dado a confirmar<\/th><th>Decis\u00e3o que orienta<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Tens\u00e3o do sistema<\/td><td>3,6\/6, 6\/10, 8,7\/15 ou 12\/20 kV?<\/td><td>Define a classe de m\u00e9dia tens\u00e3o do TTX.<\/td><\/tr>\n<tr><td>Modo de movimento<\/td><td>O cabo \u00e9 torcido em servi\u00e7o, ou apenas defletido em um plano?<\/td><td>Tor\u00e7\u00e3o \u2192 TTX; um plano \u2192 TX.<\/td><\/tr>\n<tr><td>Condi\u00e7\u00e3o de corrente<\/td><td>Estendido ou enrolado? Quantas camadas?<\/td><td>Usar o valor da pior condi\u00e7\u00e3o de enrolamento.<\/td><\/tr>\n<tr><td>Temperatura ambiente<\/td><td>Temperatura real do t\u00fanel (at\u00e9 55\u00b0C).<\/td><td>Aplicar o fator K (1,10 a 20\u00b0C &#8230; 0,71 a 55\u00b0C).<\/td><\/tr>\n<tr><td>Curto-circuito<\/td><td>Corrente presumida e tempo de atua\u00e7\u00e3o da prote\u00e7\u00e3o.<\/td><td>Converter o valor de kA publicado para o tempo real.<\/td><\/tr>\n<tr><td>Tra\u00e7\u00e3o<\/td><td>Tra\u00e7\u00e3o do sistema de puxamento.<\/td><td>Verificar contra 20 N\/mm\u00b2 sobre a se\u00e7\u00e3o de fase.<\/td><\/tr>\n<tr><td>Raio de curvatura<\/td><td>Di\u00e2metro do tambor e raios fixos, sobre o OD do TTX.<\/td><td>5\u00d7OD fixo; 10\u00d7OD em tambor.<\/td><\/tr>\n<tr><td>Tambor<\/td><td>Capacidade do tambor para o OD maior do TTX.<\/td><td>Reverificar voltas\/camadas com o di\u00e2metro acrescido da tran\u00e7a.<\/td><\/tr>\n<tr><td>Termina\u00e7\u00e3o<\/td><td>Capacidade de preparo dos semicondutores em campo.<\/td><td>Planejar termina\u00e7\u00e3o especializada de m\u00e9dia tens\u00e3o.<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"divider\"><span>XII<\/span><hr><span class=\"caption\">Perguntas frequentes de engenharia<\/span><\/div>\n<h2>12. Perguntas Frequentes de Engenharia<\/h2>\n\n<div class=\"qa\">\n<h4>Pergunta 1 \u2014 Qual a diferen\u00e7a entre TUNNELFLEX-TX e TUNNELFLEX-TTX?<\/h4>\n<p><strong>Resposta:<\/strong> A diferen\u00e7a \u00e9 a tran\u00e7a anti-tor\u00e7\u00e3o de malha aberta de fios sint\u00e9ticos, presente apenas no TTX, aplicada entre a manta interna e a bainha externa de PCP. O sistema el\u00e9trico \u2014 isola\u00e7\u00e3o HEPR-MV, blindagens semicondutoras do condutor e da isola\u00e7\u00e3o, bainhas de PCP \u2014 \u00e9 id\u00eantico nas duas. O TX serve \u00e0 deflex\u00e3o em um plano; o TTX tolera tor\u00e7\u00e3o.<\/p>\n<\/div>\n<div class=\"qa\">\n<h4>Pergunta 2 \u2014 O que \u00e9 a &#8220;tran\u00e7a de malha aberta de fios sint\u00e9ticos&#8221;?<\/h4>\n<p><strong>Resposta:<\/strong> \u00c9 um refor\u00e7o t\u00eaxtil em forma de rede (n\u00e3o uma capa fechada) feito de fios sint\u00e9ticos de alta resist\u00eancia. A malha aberta preserva a flexibilidade e o caminho de dissipa\u00e7\u00e3o de calor; os fios sint\u00e9ticos resistem ao cisalhamento torcional sem o peso e a rigidez de uma armadura met\u00e1lica. Ela restringe a rota\u00e7\u00e3o do cabo, protegendo as interfaces semicondutoras da desorganiza\u00e7\u00e3o que a tor\u00e7\u00e3o provocaria.<\/p>\n<\/div>\n<div class=\"qa\">\n<h4>Pergunta 3 \u2014 O TTX conduz mais corrente que o TX?<\/h4>\n<p><strong>Resposta:<\/strong> N\u00e3o. A capacidade de corrente, a corrente de curto-circuito e a tra\u00e7\u00e3o admiss\u00edvel s\u00e3o id\u00eanticas \u00e0s do TX \u2014 a tran\u00e7a \u00e9 um elemento mec\u00e2nico, n\u00e3o el\u00e9trico. O TTX apenas acrescenta cerca de 0,8 mm de di\u00e2metro e de 100 a 180 kg\/km de peso por causa da tran\u00e7a.<\/p>\n<\/div>\n<div class=\"qa\">\n<h4>Pergunta 4 \u2014 Por que a tabela de temperatura do TTX vai at\u00e9 55\u00b0C?<\/h4>\n<p><strong>Resposta:<\/strong> A folha de dados do TTX inclui o degrau de 55\u00b0C (K = 0,71), uma classe al\u00e9m do TX (que para em 50\u00b0C). Isso reconhece ambientes quentes de galeria profunda. A 55\u00b0C, a capacidade de corrente cai para 71% do valor de cat\u00e1logo, e essa corre\u00e7\u00e3o deve ser combinada com o derating de enrolamento em tambor.<\/p>\n<\/div>\n<div class=\"qa\">\n<h4>Pergunta 5 \u2014 Quando devo escolher TTX em vez de TX?<\/h4>\n<p><strong>Resposta:<\/strong> Quando o sistema mec\u00e2nico imp\u00f5e tor\u00e7\u00e3o ao cabo \u2014 quando ele gira em torno do pr\u00f3prio eixo ao ser enrolado, desenrolado ou guiado por um trajeto que muda de plano. Se h\u00e1 apenas deflex\u00e3o em um plano, o TX \u00e9 a escolha correta: mesma performance el\u00e9trica, menos peso e di\u00e2metro.<\/p>\n<\/div>\n<div class=\"qa\">\n<h4>Pergunta 6 \u2014 A tran\u00e7a aumenta a tra\u00e7\u00e3o admiss\u00edvel do cabo?<\/h4>\n<p><strong>Resposta:<\/strong> A tran\u00e7a \u00e9 um elemento de resist\u00eancia \u00e0 tor\u00e7\u00e3o, n\u00e3o necessariamente de tra\u00e7\u00e3o axial. A tra\u00e7\u00e3o de puxamento deve continuar respeitando o limite de 20 N\/mm\u00b2 sobre a se\u00e7\u00e3o de cobre de fase (1500 N na 3&#215;25, por exemplo), aplicada pelos condutores ou por uma malha\/olhal de tra\u00e7\u00e3o apropriado. Confirme o valor na folha de dados emitida.<\/p>\n<\/div>\n\n<div class=\"success\">\n<h4>Vis\u00e3o de Engenharia Feichun<\/h4>\n<p>O TUNNELFLEX-TTX RS-(N)TSCGEWOEU \u00e9 o quarto e \u00faltimo quadrante da fam\u00edlia TUNNELFLEX: m\u00e9dia tens\u00e3o, de 3,6\/6 a 12\/20 kV, com prote\u00e7\u00e3o anti-tor\u00e7\u00e3o. Ele re\u00fane o sistema el\u00e9trico do TX \u2014 condutor de cobre classe 5 de constru\u00e7\u00e3o m\u00f3vel, blindagem semicondutora do condutor, isola\u00e7\u00e3o HEPR-MV micro-filtrada melhor que 3GI3, blindagem semicondutora da isola\u00e7\u00e3o e bainhas de PCP com a externa vermelha \u2014 e acrescenta uma tran\u00e7a de malha aberta de fios sint\u00e9ticos entre a manta interna e a bainha externa, que absorve o esfor\u00e7o torcional e protege as interfaces semicondutoras da rota\u00e7\u00e3o. Essa tran\u00e7a custa cerca de 0,8 mm de di\u00e2metro e de 100 a 180 kg\/km de peso, sem alterar a corrente, o curto-circuito (at\u00e9 34,3 kA na 3&#215;240) nem a tra\u00e7\u00e3o (20 N\/mm\u00b2) em rela\u00e7\u00e3o ao TX. A folha de dados do TTX estende a corre\u00e7\u00e3o de temperatura at\u00e9 55\u00b0C (K = 0,71), uma classe al\u00e9m do TX, reconhecendo galerias quentes. A sele\u00e7\u00e3o segue dois eixos independentes: a tens\u00e3o decide a classe de MT; o modo de movimento decide TX ou TTX. Escolha o TTX quando o cabo \u00e9 comprovadamente torcido em servi\u00e7o, e o TX quando h\u00e1 apenas deflex\u00e3o em um plano. Em ambos, dimensione pela pior condi\u00e7\u00e3o de enrolamento no tambor corrigida pelo fator K, verifique a tra\u00e7\u00e3o contra 20 N\/mm\u00b2 sobre a se\u00e7\u00e3o de fase e o raio de curvatura (5\u00d7OD fixo, 10\u00d7OD em tambor) sobre o OD real, e converta a corrente de curto-circuito ao tempo de atua\u00e7\u00e3o da prote\u00e7\u00e3o. Assim a fam\u00edlia TUNNELFLEX entrega, em cada quadrante, exatamente o cabo que o t\u00fanel exige.<\/p>\n<\/div>\n\n<\/main>\n<\/div>\n\n<footer>\n<div class=\"container\">\n<h4>Anhui Feichun Special Cable Co., Ltd. \u2014 Engenharia de Cabos Flex\u00edveis de M\u00e9dia Tens\u00e3o para Tunelamento e Minera\u00e7\u00e3o<\/h4>\n<p>A Anhui Feichun Special Cable Co., Ltd. atende fabricantes OEM, empreiteiras de tunelamento, fabricantes de tuneladoras (TBM), fornecedores de equipamentos de minera\u00e7\u00e3o e usu\u00e1rios industriais que necessitam de cabos flex\u00edveis de m\u00e9dia tens\u00e3o de 3,6\/6 a 12\/20kV com isola\u00e7\u00e3o HEPR-MV, blindagens semicondutoras e prote\u00e7\u00e3o anti-tor\u00e7\u00e3o por tran\u00e7a de malha aberta de fios sint\u00e9ticos, al\u00e9m de documenta\u00e7\u00e3o t\u00e9cnica para projetos internacionais de minera\u00e7\u00e3o e tunelamento.<\/p>\n<div class=\"contact\">\n<p><strong>Contato de Engenharia Feichun<\/strong><br>\nTelefone: +86 13855123218<br>\nE-mail: <a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/p>\n<\/div>\n<p>A Feichun apoia clientes que necessitam de solu\u00e7\u00f5es em cabos flex\u00edveis de m\u00e9dia tens\u00e3o para tunelamento e minera\u00e7\u00e3o: escolha entre vers\u00f5es com e sem prote\u00e7\u00e3o anti-tor\u00e7\u00e3o, dimensionamento da capacidade de corrente em condi\u00e7\u00e3o de enrolamento de tambor, aplica\u00e7\u00e3o de fatores de corre\u00e7\u00e3o de temperatura at\u00e9 55\u00b0C, convers\u00e3o de corrente de curto-circuito, verifica\u00e7\u00e3o de tra\u00e7\u00e3o e c\u00e1lculo de raio de curvatura.<\/p>\n<div class=\"docid\">Refer\u00eancia do Documento: FEICHUN-TUNNELFLEX-TTX-RS-NTSCGEWOEU-3-6-6-A-12-20KV-COM-ANTITORCAO-PT-BR-V1 \u00b7 TUNNELFLEX-TTX RS-(N)TSCGEWOEU 3,6\/6 a 12\/20 kV \u00b7 COM Prote\u00e7\u00e3o Anti-Tor\u00e7\u00e3o (Tran\u00e7a de Malha Aberta de Fios Sint\u00e9ticos) \u00b7 Isola\u00e7\u00e3o HEPR-MV melhor que 3GI3 \u00b7 Blindagens Semicondutoras do Condutor e da Isola\u00e7\u00e3o \u00b7 Mantas e Bainhas de PCP \u00b7 Bainha Externa Vermelha \u00b7 Cobre Classe 5 DIN VDE 0295 \u00b7 Corre\u00e7\u00e3o de Temperatura at\u00e9 55\u00b0C (K=0,71) \u00b7 Tra\u00e7\u00e3o 20N\/mm\u00b2 \u00b7 Raio 5\u00d7OD Fixo \/ 10\u00d7OD Tambor \u00b7 Curto-Circuito at\u00e9 34,3kA \u00b7 Condutor 90\u00b0C \u00b7 Engenharia Feichun<\/div>\n<\/div>\n<\/footer>\n<\/body>\n<\/html>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/FeiChun-Special-Cables-\u2014-Cables-para-Mineria-_-EXPOMINA-Peru-2026.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u5d4c\u5165 FeiChun Special Cables \u2014 Cables para Miner\u00eda _ EXPOMINA Per\u00fa 2026\"><\/object><a id=\"wp-block-file--media-26768fa9-7e31-4fe1-9030-0cc987ff6d7b\" href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/FeiChun-Special-Cables-\u2014-Cables-para-Mineria-_-EXPOMINA-Peru-2026.pdf\">FeiChun Special Cables \u2014 Cables para Miner\u00eda _ EXPOMINA Per\u00fa 2026<\/a><a href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/FeiChun-Special-Cables-\u2014-Cables-para-Mineria-_-EXPOMINA-Peru-2026.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-26768fa9-7e31-4fe1-9030-0cc987ff6d7b\">\u4e0b\u8f7d<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"O TUNNELFLEX-TTX RS-(N)TSCGEWOEU \u00e9 a vers\u00e3o de m\u00e9dia tens\u00e3o da fam\u00edlia TUNNELFLEX equipada com prote\u00e7\u00e3o anti-tor\u00e7\u00e3o \u2014 uma tran\u00e7a de malha aberta de fios sint\u00e9ticos aplicada entre a manta interna e a bainha externa de PCP. Ele alimenta equipamentos m\u00f3veis com alto risco de dano mec\u00e2nico em tunelamento, nas mesmas quatro classes de tens\u00e3o do TUNNELFLEX-TX (3,6\/6 a 12\/20 kV), mas para sistemas em que o cabo n\u00e3o \u00e9 apenas defletido em um plano, e sim torcido em torno do pr\u00f3prio eixo durante o servi\u00e7o. O TTX completa a fam\u00edlia: ele est\u00e1 para o TX assim como o R\/PUR est\u00e1 para o PUR na baixa tens\u00e3o \u2014 a mesma constru\u00e7\u00e3o el\u00e9trica, acrescida do elemento que absorve o esfor\u00e7o torcional.","protected":false},"author":1,"featured_media":20506,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[46,66],"tags":[411,66117,60419,150,60427,66114,60432,65851,60436,52250,66122,63,66181,66179,48,65891,59,66218,63082,51,7643,66178,66220,66099,65904,16165,66206,66026,66173,64387,66174,66172,65840,66162,26503,35945,66203,66148,66163,63524,66082,43801,65910,66164,66098,66196,66166,65934,65832,66078,66075,66104,66150,63331,63525,66112,66111,569,66105,66175,66125,66165,12254,64515,43824,65907,66089,66180,66113,66115,60474,62457,66094,66208,64517,66153,66210,66209,16163,66205,66197,19124,66176,66201,15226,66216,66219,66214,66073,66156,66170,65815,9822,21702,66198,66207,31731,16198,66168,66213,66121,66177,63109,65921,66215,66154,64509,66145,3857,44646,55032,66182,66200,60776,66009,33003,63520,63505,66211,66155,8661,66217,66202,63510,66204,66199,66212,66109,66110,21689,63299,63300,63340,63325,63322,66195,66151,66147,22749],"class_list":["post-20832","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cable-for-shore-connection-systems","category-common-problems-encountered-in-cable-applications","tag-iec-60228","tag-1-camada","tag-11kv","tag-12-20kv","tag-17kv","tag-2-camadas","tag-24kv","tag-250c-curto-circuito","tag-29kv","tag-52250","tag-3-camadas","tag-3-6-6kv","tag-34-2","tag-3ka","tag-6-10kv","tag-6-6kv","tag-7-15kv","tag-66218","tag-63082","tag-8-7-15kv","tag-90c-conductor-temperature","tag-90250c","tag-adiabatic-calculation","tag-alto-risco-de-dano-mecanico","tag-anhui-feichun-special-cable-co","tag-anti-twisting-braid","tag-ate-55c","tag-bainha-pcp","tag-bainha-vermelha","tag-bare-copper-conductors","tag-blindagem-da-isolacao","tag-blindagem-do-condutor","tag-blindagem-semicondutora","tag-borracha-de-etileno-propileno","tag-cable-festoon","tag-cable-track","tag-calculo-adiabatico","tag-camada-semicondutora-extrudada","tag-campo-radial-uniforme","tag-capacidade-de-corrente","tag-cei","tag-class-5-conductors","tag-classe-5","tag-cobertura-semicondutora","tag-cobre-nu","tag-com-protecao-anti-torcao","tag-composto-micro-filtrado","tag-condutores-classe-5","tag-condutores-de-cobre-nu","tag-condutores-de-fase","tag-condutores-de-terra","tag-construcao-especial-para-servico-movel","tag-controle-de-campo-eletrico","tag-core-screen-2","tag-corrente-de-curto-circuito","tag-corrente-em-camadas","tag-corrente-estendida","tag-current-rating","tag-deflexao-em-um-unico-plano","tag-densidade-de-corrente","tag-derating-de-tambor","tag-descargas-parciais","tag-din-vde-0295","tag-drum-bending-radius-10xod","tag-drum-derating","tag-equipamentos-moveis","tag-esteira-de-cabo","tag-exoesqueleto-textil","tag-fator-de-correcao-de-temperatura","tag-fator-k","tag-feichun-cables","tag-feichun-engineering","tag-festao","tag-fios-sinteticos","tag-fixed-bending-radius-5xod","tag-flexao-em-um-plano","tag-frontes-de-obra","tag-galerias","tag-hepr-mv-insulation","tag-high-mechanical-damage-risk","tag-inner-sheath-pcp","tag-insulation-screen","tag-isolacao-hepr-mv","tag-k0","tag-ltd-4","tag-malha-aberta","tag-malha-aberta-de-fios-sinteticos","tag-manta-interna-pcp","tag-maquinas-de-escavacao","tag-media-tensao","tag-melhor-que-3gi3","tag-mineracao","tag-mining","tag-mobile-equipment","tag-open-mesh","tag-open-mesh-synthetic-yarns","tag-partial-discharge","tag-pcp-sheath","tag-policloropreno","tag-protecao-contra-torcao","tag-raio-de-curvatura-em-tambor-10xod","tag-raio-de-curvatura-fixo-5xod","tag-red-sheath","tag-resistencia-a-abrasao","tag-restricao-de-rotacao","tag-rotacao-do-cabo","tag-rs-ntscgewoeu","tag-sem-protecao-anti-torcao","tag-semiconductive-screen","tag-short-circuit-current-2","tag-short-circuit-temperature-2","tag-suportabilidade-a-curto-circuito","tag-synthetic-yarns","tag-tbm","tag-temperatura-maxima-do-condutor-90c","tag-temperature-correction-factor","tag-tensao-de-ensaio","tag-tensao-nominal","tag-textile-exoskeleton","tag-torcao","tag-torsion-protection","tag-tracao-20-n-mm","tag-traction-20n-mm","tag-tranca-anti-torcao","tag-tranca-de-malha-aberta","tag-ttx-com-anti-torcao","tag-tuneis","tag-tuneladora","tag-tunelamento","tag-tunnel-boring-machine","tag-tunnelflex-pur-2","tag-tunnelflex-r-pur-2","tag-tunnelflex-ttx","tag-tunnelflex-tx","tag-tunneling","tag-tx-sem-anti-torcao","tag-um","tag-uo-u","tag-vde","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/20832","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=20832"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/20832\/revisions"}],"predecessor-version":[{"id":20852,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/20832\/revisions\/20852"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/20506"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=20832"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=20832"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=20832"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}