{"id":17440,"date":"2026-06-10T10:24:03","date_gmt":"2026-06-10T02:24:03","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=17440"},"modified":"2026-06-10T10:24:06","modified_gmt":"2026-06-10T02:24:06","slug":"what-is-protolon-xprt-lwl-ntskcgewoeu-6-10kv-an-in-depth-engineering-analysis-of-the-fibre-optic-hybrid-medium-voltage-reeling-cable","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/what-is-protolon-xprt-lwl-ntskcgewoeu-6-10kv-an-in-depth-engineering-analysis-of-the-fibre-optic-hybrid-medium-voltage-reeling-cable\/","title":{"rendered":"What is PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV: An In-Depth Engineering Analysis of the Fibre-Optic Hybrid Medium Voltage Reeling Cable"},"content":{"rendered":"\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n  <meta charset=\"UTF-8\">\n  <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0, viewport-fit=cover\">\n  <meta name=\"description\" content=\"What is PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV? In-depth engineering analysis of the fibre-optic hybrid medium voltage reeling cable: 24 singlemode E9 optical fibres (24E9LWL) integrated into a 6\/10 kV rubber reeling cable for STS, RTG and RMG container cranes, ship unloaders and large mobile equipment. Construction, electrical, mechanical and optical parameters, dimensional tables from 3x25 to 3x300 mm\u00b2, comparison with standard (N)TSCGEWOEU and two-reel solutions, selection framework and engineer FAQ.\">\n  <meta name=\"keywords\" content=\"PROTOLON XPRT,PROTOLON XPRT-LWL,(N)TSKCGEWOEU,6\/10kV reeling cable,medium voltage reeling cable with fiber optics,fibre optic hybrid cable,opto-power reeling cable,24E9LWL,singlemode reeling cable,STS crane cable,RTG crane cable,RMG crane cable,container crane cable,ship unloader cable,crane automation cable,combined power data cable,FORJ,fiber optic rotary joint,Feichun cables\">\n  <meta property=\"og:title\" content=\"What is PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV: Fibre-Optic Hybrid Medium Voltage Reeling Cable \u2014 In-Depth Engineering Analysis\">\n  <meta property=\"og:description\" content=\"Engineering analysis of the PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV opto-power reeling cable: 6\/10 kV medium voltage power, split earth conductors and 24 singlemode E9 optical fibres on a single reel for high to extreme mechanical stress crane applications.\">\n  <title>What is PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV: Fibre-Optic Hybrid Medium Voltage Reeling Cable \u2014 In-Depth Engineering Analysis<\/title>\n\n  <style>\n    :root{\n      --bg:#0b111a;\n      --panel:#141f2f;\n      --panel2:#1b2a40;\n      --line:#354a66;\n      --text:#eef5ff;\n      --muted:#b8c7da;\n      --red:#ff3b30;\n      --orange:#ff8a00;\n      --yellow:#ffd54a;\n      --blue:#2f8cff;\n      --green:#00d084;\n      --cyan:#4ecdc4;\n      --purple:#b388ff;\n    }\n    *{box-sizing:border-box;margin:0;padding:0}\n    body{\n      font-family:\"Segoe UI\",\"Microsoft YaHei\",Arial,sans-serif;\n      background:var(--bg);\n      color:var(--text);\n      line-height:1.75;\n      overflow-x:hidden;\n    }\n    .container{max-width:1080px;margin:0 auto;padding:0 22px}\n    .hero{\n      padding:74px 20px;\n      text-align:center;\n      border-bottom:3px solid var(--orange);\n      background:\n        radial-gradient(circle at 10% 12%,rgba(78,205,196,.30),transparent 34%),\n        radial-gradient(circle at 88% 18%,rgba(255,138,0,.30),transparent 34%),\n        radial-gradient(circle at 70% 86%,rgba(47,140,255,.22),transparent 38%),\n        linear-gradient(135deg,#070c13 0%,#111f31 46%,#102726 100%);\n    }\n    .badges{display:flex;justify-content:center;gap:10px;flex-wrap:wrap;margin-bottom:26px}\n    .badge{\n      padding:9px 15px;\n      border-radius:4px;\n      font-size:11px;\n      font-weight:800;\n      letter-spacing:1px;\n      text-transform:uppercase;\n      border:1px solid rgba(255,255,255,.22);\n    }\n    .b1{background:var(--orange);color:#071018}\n    .b2{background:var(--red)}\n    .b3{background:var(--blue)}\n    .b4{background:var(--green);color:#071018}\n    .b5{background:var(--cyan);color:#071018}\n    h1{\n      max-width:1040px;\n      margin:0 auto 20px;\n      font-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\n      font-size:42px;\n      line-height:1.15;\n      text-shadow:0 3px 14px rgba(0,0,0,.4);\n    }\n    .hero p{\n      max-width:980px;\n      margin:0 auto;\n      color:rgba(255,255,255,.88);\n      font-size:16px;\n    }\n    .meta{\n      display:flex;\n      justify-content:center;\n      gap:16px;\n      flex-wrap:wrap;\n      margin-top:28px;\n      color:rgba(255,255,255,.78);\n      font-size:12px;\n    }\n    .cards{\n      display:grid;\n      grid-template-columns:repeat(auto-fit,minmax(240px,1fr));\n      gap:20px;\n      margin:48px 0;\n    }\n    .card{\n      background:var(--panel);\n      border:1px solid var(--line);\n      border-left:6px solid var(--orange);\n      border-radius:7px;\n      padding:22px;\n    }\n    .card:nth-child(2){border-left-color:var(--cyan)}\n    .card:nth-child(3){border-left-color:var(--blue)}\n    .card:nth-child(4){border-left-color:var(--green)}\n    .card:nth-child(5){border-left-color:var(--yellow)}\n    .card:nth-child(6){border-left-color:var(--purple)}\n    .label{\n      font-size:11px;\n      color:var(--muted);\n      text-transform:uppercase;\n      letter-spacing:.8px;\n      font-weight:800;\n      margin-bottom:8px;\n    }\n    .value{\n      font-family:Georgia,\"Times New Roman\",serif;\n      font-size:30px;\n      font-weight:800;\n      color:var(--orange);\n      line-height:1.1;\n    }\n    .card:nth-child(2) .value{color:var(--cyan)}\n    .card:nth-child(3) .value{color:var(--blue)}\n    .card:nth-child(4) .value{color:var(--green)}\n    .card:nth-child(5) .value{color:var(--yellow)}\n    .card:nth-child(6) .value{color:var(--purple)}\n    .unit{font-size:12px;color:var(--muted);margin-top:8px}\n    main{padding:12px 0 60px}\n    h2{\n      font-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\n      font-size:34px;\n      color:var(--orange);\n      line-height:1.25;\n      margin:56px 0 22px;\n      padding-bottom:15px;\n      border-bottom:3px solid var(--red);\n    }\n    h3{\n      font-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\n      font-size:25px;\n      color:var(--green);\n      margin:38px 0 16px;\n      line-height:1.32;\n    }\n    h4{\n      font-size:15px;\n      color:var(--orange);\n      margin:24px 0 12px;\n      text-transform:uppercase;\n      letter-spacing:.7px;\n    }\n    p,li{color:var(--muted);font-size:15px}\n    p{margin:0 0 20px}\n    ul,ol{margin:18px 0 26px 28px}\n    li{margin-bottom:10px}\n    strong{color:var(--orange)}\n    a{color:var(--cyan);text-decoration:none}\n    a:hover{text-decoration:underline}\n    .divider{\n      display:flex;\n      align-items:center;\n      gap:16px;\n      margin:58px 0 12px;\n    }\n    .divider span:first-child{\n      background:var(--orange);\n      color:#071018;\n      padding:7px 15px;\n      border-radius:4px;\n      font-size:11px;\n      font-weight:800;\n      letter-spacing:1px;\n      text-transform:uppercase;\n    }\n    .divider hr{flex:1;border:none;border-top:1px solid var(--line)}\n    .divider .caption{color:var(--muted);font-size:13px}\n    .note{\n      background:linear-gradient(120deg,rgba(255,138,0,.14),rgba(78,205,196,.12));\n      border-left:6px solid var(--orange);\n      border-right:2px solid var(--cyan);\n      padding:24px;\n      border-radius:7px;\n      margin:28px 0;\n    }\n    .success{\n      background:linear-gradient(135deg,#b34c00,#ff8a00);\n      color:#fff;\n      border-radius:8px;\n      padding:25px;\n      margin:30px 0;\n      box-shadow:0 8px 28px rgba(255,138,0,.22);\n    }\n    .success p{color:rgba(255,255,255,.92)}\n\n    .table-scroll{\n      width:100%;\n      overflow-x:auto;\n      overflow-y:hidden;\n      -webkit-overflow-scrolling:touch;\n      margin:30px 0;\n      border:1px solid var(--line);\n      border-radius:7px;\n      background:var(--panel);\n    }\n    .table-scroll table{\n      width:max-content;\n      min-width:1100px;\n      border-collapse:collapse;\n      margin:0;\n      border:none;\n      display:table;\n      font-size:13px;\n    }\n    .table-scroll.wide table{min-width:1500px}\n    .table-scroll.medium table{min-width:1250px}\n    .table-scroll th{\n      background:#080f18;\n      color:var(--orange);\n      font-size:12px;\n      text-align:left;\n      padding:12px;\n      border-bottom:2px solid var(--line);\n      white-space:nowrap;\n    }\n    .table-scroll td{\n      padding:12px;\n      border-bottom:1px solid var(--line);\n      color:var(--muted);\n      vertical-align:top;\n      white-space:nowrap;\n    }\n    .table-scroll tr:hover td{background:rgba(255,138,0,.06)}\n    .table-scroll::-webkit-scrollbar{height:10px}\n    .table-scroll::-webkit-scrollbar-track{background:#080f18}\n    .table-scroll::-webkit-scrollbar-thumb{background:var(--orange);border-radius:10px}\n\n    .layer{\n      background:var(--panel);\n      border:1px solid var(--line);\n      border-left:5px solid var(--orange);\n      padding:18px 20px;\n      border-radius:6px;\n      margin:16px 0;\n    }\n    .layer:nth-of-type(2n){border-left-color:var(--cyan)}\n    .layer-title{\n      font-weight:800;\n      color:var(--text);\n      font-size:16px;\n      margin-bottom:7px;\n    }\n    .layer-text{color:var(--muted);font-size:13px}\n    .formula{\n      background:#080f18;\n      border:1px solid var(--line);\n      border-left:5px solid var(--cyan);\n      border-radius:7px;\n      padding:18px 20px;\n      margin:22px 0;\n      color:var(--muted);\n      font-family:Consolas,Monaco,monospace;\n      font-size:13px;\n      overflow-x:auto;\n    }\n    .qa{\n      background:var(--panel2);\n      border:1px solid var(--line);\n      border-left:5px solid var(--green);\n      border-radius:7px;\n      padding:22px;\n      margin:24px 0;\n    }\n    .qa h4{margin-top:0;color:var(--green)}\n    footer{\n      background:#070c13;\n      border-top:3px solid var(--orange);\n      padding:48px 20px;\n      margin-top:40px;\n    }\n    footer h4{\n      font-family:Georgia,\"Times New Roman\",\"Microsoft YaHei\",serif;\n      font-size:24px;\n      text-transform:none;\n      letter-spacing:0;\n      color:var(--orange);\n    }\n    .contact{\n      background:var(--panel);\n      border:1px solid var(--line);\n      border-left:5px solid var(--orange);\n      border-radius:7px;\n      padding:20px;\n      margin:22px 0;\n      color:var(--muted);\n    }\n    .docid{\n      text-align:center;\n      color:#72849a;\n      font-size:11px;\n      margin-top:28px;\n      padding-top:22px;\n      border-top:1px solid var(--line);\n    }\n    @media(max-width:640px){\n      h1{font-size:31px}\n      h2{font-size:27px}\n      h3{font-size:22px}\n      .hero{padding:48px 16px}\n      .value{font-size:27px}\n      .table-scroll table{min-width:1150px}\n      .table-scroll.wide table{min-width:1550px}\n    }\n  <\/style>\n<\/head>\n<body>\n\n  <section class=\"hero\">\n    <div class=\"container\">\n      <div class=\"badges\">\n        <span class=\"badge b1\">PROTOLON XPRT-LWL<\/span>\n        <span class=\"badge b2\">(N)TSKCGEWOEU<\/span>\n        <span class=\"badge b3\">6\/10kV<\/span>\n        <span class=\"badge b4\">Opto-Power Reeling Cable<\/span>\n        <span class=\"badge b5\">24 \u00d7 E9 Singlemode Fibres<\/span>\n      <\/div>\n      <h1>What is PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV: An In-Depth Engineering Analysis of the Fibre-Optic Hybrid Medium Voltage Reeling Cable<\/h1>\n      <p>PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV is a flexible medium voltage opto-power reeling cable designed for high to extreme mechanical stresses: high travel speeds, dynamic tensile loads, multiple changes of direction into different planes, churning on running over rollers and torsional stress. Its defining feature is the integration of a protected optical element with 24 singlemode E9 fibres \u2014 designated 24E9LWL \u2014 into a 6\/10 kV three-core rubber reeling cable with split earth conductors. The result is a single cable on a single reel that simultaneously carries medium voltage power, the protective earth function and a high-bandwidth, EMI-immune fibre-optic data backbone for crane automation, CCTV, remote operation and terminal operating system connectivity on fast-moving container cranes and large mobile equipment.<\/p>\n      <div class=\"meta\">\n        <span>\u2713 Medium voltage opto-power reeling cable<\/span>\n        <span>\u2713 6\/10 (12) kV<\/span>\n        <span>\u2713 24 \u00d7 E9 singlemode optical fibres<\/span>\n        <span>\u2713 High to extreme mechanical stress design<\/span>\n        <span>\u2713 Power + earth + data on one reel<\/span>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <div class=\"container\">\n    <div class=\"cards\">\n      <div class=\"card\"><div class=\"label\">Voltage Class<\/div><div class=\"value\">6\/10<\/div><div class=\"unit\">Rated voltage U0\/U (Um): 6\/10 (12) kV<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Optical Element<\/div><div class=\"value\">24\u00d7E9<\/div><div class=\"unit\">24 singlemode fibres, 9\/125 \u00b5m class (LWL)<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Test Voltage<\/div><div class=\"value\">17kV<\/div><div class=\"unit\">AC test voltage of the 6\/10 kV insulation system<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Torsion<\/div><div class=\"value\">\u00b125\u00b0<\/div><div class=\"unit\">Permissible torsional stress \u00b125\u00b0\/m<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Dynamic Pull<\/div><div class=\"value\">30<\/div><div class=\"unit\">Dynamic tensile rule 30 N\/mm\u00b2 on power cores<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Largest Size<\/div><div class=\"value\">300<\/div><div class=\"unit\">Largest listed size 3&#215;300+2&#215;150\/2 +1x(24E9LWL)<\/div><\/div>\n    <\/div>\n\n    <main>\n      <div class=\"divider\"><span>I<\/span><hr><span class=\"caption\">Definition and application<\/span><\/div>\n      <h2>1. What is PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV?<\/h2>\n      <p><strong>PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV<\/strong> is a flexible medium voltage reeling cable for high to extreme mechanical stress applications, combined with an integrated fibre-optic data subsystem. It belongs to the same engineering family as the classic (N)TSCGEWOEU medium voltage reeling cables, but it answers a question that pure power cables cannot: how do you bring gigabit-class data communication to a machine that travels hundreds of metres on a motorized cable reel, without adding a second reel, a second cable path and a second maintenance object?<\/p>\n\n      <p>The answer is structural integration. Three medium voltage power cores supply the drives, hoists and auxiliary systems of the machine. Two split protective earth conductors occupy two of the three interstices between the cores. The third interstice carries a protected optical element with <strong>24 singlemode E9 fibres<\/strong>, giving the machine a permanent optical link for PLC and drive communication, IP cameras and OCR gates, anti-sway and positioning systems, remote operation stations and terminal operating system (TOS) integration \u2014 all immune to the electromagnetic environment created by the medium voltage cores running centimetres away.<\/p>\n\n      <p>Typical equipment includes ship-to-shore (STS) container cranes, rail-mounted gantry cranes (RMG), electrified rubber-tyred gantry cranes (RTG-E), ship loaders and unloaders, stacker-reclaimers, bucket-wheel excavators, spreaders and other large moving machines in ports, terminals, bulk handling plants and open-cast mining where medium voltage power and high-bandwidth data must travel together over a reeling system.<\/p>\n\n      <div class=\"note\">\n        <h4>Technical thesis<\/h4>\n        <p><strong>Engineering argument:<\/strong> the core value of PROTOLON XPRT-LWL 6\/10kV is consolidation under extreme mechanical duty. One reel, one cable path and one cable management system replace what would otherwise be two independent reeling systems \u2014 a medium voltage power reel and a separate fibre-optic reel \u2014 that must be purchased, installed, synchronized, inspected and stocked with spares separately. Every elimination of a moving subsystem on a crane is an elimination of a failure mode; the hybrid design moves the integration problem from the crane builder&#8217;s drawing board into the cable cross-section, where it is solved once, at the factory.<\/p>\n      <\/div>\n\n      <h3>1.1 Application profile decoded<\/h3>\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>Application dimension<\/th>\n              <th>Datasheet description<\/th>\n              <th>Engineering meaning<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>Cable category<\/td><td>Medium voltage opto-power reeling cable<\/td><td>Flexible 6\/10 kV reeling cable with integrated fibre-optic element for mobile power and data supply.<\/td><\/tr>\n            <tr><td>Mechanical stress class<\/td><td>High to extreme mechanical stresses<\/td><td>Designed for the most severe reeling duty class, not for light or occasional movement.<\/td><\/tr>\n            <tr><td>Travel speed<\/td><td>High travel speeds<\/td><td>Suitable for fast-moving gantry cranes and high-speed reel pick-up and pay-off.<\/td><\/tr>\n            <tr><td>Dynamic tensile loads<\/td><td>Starting, braking, acceleration, reel tension<\/td><td>The cable and the optical element must survive repeated dynamic tension events, not only static hang loads.<\/td><\/tr>\n            <tr><td>Direction changes<\/td><td>Multiple changes of direction into different planes<\/td><td>Suitable for complex roller arrangements, guide sheaves and multi-plane cable paths.<\/td><\/tr>\n            <tr><td>Roller operation<\/td><td>Churning on running over rollers<\/td><td>Sheath and internal structure resist roller churning, compression and abrasion.<\/td><\/tr>\n            <tr><td>Torsional stress<\/td><td>\u00b125\u00b0\/m class torsion duty<\/td><td>Reinforcement and stranding geometry control twist damage to both copper and glass.<\/td><\/tr>\n            <tr><td>Data subsystem<\/td><td>1x(24E9LWL) optical element<\/td><td>24 singlemode fibres for automation, CCTV, remote control and TOS communication.<\/td><\/tr>\n            <tr><td>Typical equipment<\/td><td>Fast-moving container cranes and large mobile equipment<\/td><td>STS, RMG, RTG-E cranes, ship unloaders, stacker-reclaimers, mining machines.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"divider\"><span>II<\/span><hr><span class=\"caption\">Type designation and standards<\/span><\/div>\n      <h2>2. Reading the Designation: (N)TSKCGEWOEU and 24E9LWL Explained<\/h2>\n      <p>Harbour and crane engineers usually meet this cable for the first time as a type code in a crane specification. The designation follows the German VDE convention for heavy rubber reeling cables. The table below gives the working reading used in practice for this cable family.<\/p>\n\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>Code element<\/th>\n              <th>Working reading<\/th>\n              <th>What it tells the engineer<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>(N)<\/td><td>Standards-derived type<\/td><td>Design based on the VDE standard family (DIN VDE 0250-813) with manufacturer-specific enhancements.<\/td><\/tr>\n            <tr><td>T<\/td><td>Trommel \u2014 reeling duty<\/td><td>Built for motorized cable reels, not only festoon or fixed installation.<\/td><\/tr>\n            <tr><td>S<\/td><td>Heavy duty<\/td><td>Heavy rubber-sheathed construction for severe mechanical service.<\/td><\/tr>\n            <tr><td>K<\/td><td>Combined (hybrid) design<\/td><td>Within this family, the K distinguishes the combined opto-power construction of the XPRT-LWL version from the standard (N)TSCGEWOEU power-only type.<\/td><\/tr>\n            <tr><td>C<\/td><td>Protective conductor concept<\/td><td>Split protective earth conductors arranged in the interstices around the power cores.<\/td><\/tr>\n            <tr><td>G<\/td><td>Rubber insulation and sheathing<\/td><td>EPR insulation with elastomer sheaths \u2014 the basis of cold flexibility and reeling life.<\/td><\/tr>\n            <tr><td>E \/ W<\/td><td>Enhanced thermal design<\/td><td>Increased heat resistance for 90\u00b0C conductor operation.<\/td><\/tr>\n            <tr><td>OE (\u00d6)<\/td><td>Oil resistant<\/td><td>Sheath compound tested for oil resistance (DIN EN 60811-404 \/ IEC 60811-404 class testing).<\/td><\/tr>\n            <tr><td>U<\/td><td>Flame retardant<\/td><td>Sheath does not propagate flame \u2014 essential on cranes and in tunnels and machine houses.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <h3>2.1 What does 24E9LWL mean?<\/h3>\n      <div class=\"table-scroll\">\n        <table>\n          <thead>\n            <tr>\n              <th>Element<\/th>\n              <th>Meaning<\/th>\n              <th>Engineering relevance<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>24<\/td><td>Fibre count<\/td><td>24 optical fibres \u2014 enough for redundant rings, CCTV, automation, remote operation and spare capacity.<\/td><\/tr>\n            <tr><td>E9<\/td><td>Singlemode fibre, 9\/125 \u00b5m class<\/td><td>Singlemode glass of the ITU-T G.652 class with a nominal 9 \u00b5m core \u2014 low attenuation at 1310\/1550 nm and effectively unlimited bandwidth-distance product for crane-scale links.<\/td><\/tr>\n            <tr><td>LWL<\/td><td>Lichtwellenleiter \u2014 optical fibre (German)<\/td><td>Marks the cable as a fibre-optic hybrid in German-convention type codes; international datasheets often write FO or 24FO for the same concept.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <h3>2.2 Standards landscape<\/h3>\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>Standard \/ reference<\/th>\n              <th>Scope in this cable<\/th>\n              <th>Engineering significance<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>DIN VDE 0250-813<\/td><td>General design basis<\/td><td>The reference standard for heavy medium voltage rubber reeling cables of this family.<\/td><\/tr>\n            <tr><td>DIN VDE 0298-4<\/td><td>Electrical parameters<\/td><td>Current-carrying capacity reference for rubber cables (Table 15, 30\u00b0C ambient, in air).<\/td><\/tr>\n            <tr><td>DIN EN 60228 \/ IEC 60228 \/ VDE 0295<\/td><td>Conductor classes<\/td><td>Very finely stranded tinned copper, class FS \u2014 the flexibility basis of reeling life.<\/td><\/tr>\n            <tr><td>VDE 0298-3<\/td><td>Bending radii rules<\/td><td>Source of the 6\u00d7D fixed \/ 10\u00d7D moving \/ 20\u00d7D S-type direction change rules.<\/td><\/tr>\n            <tr><td>DIN EN 60811-404 \/ IEC 60811-404<\/td><td>Chemical behaviour<\/td><td>Oil immersion testing of the sheath compounds.<\/td><\/tr>\n            <tr><td>IEC 60793 \/ IEC 60794 \/ ITU-T G.652 class<\/td><td>Optical fibre and FO unit<\/td><td>Singlemode fibre geometry, attenuation classes and optical cable element testing conventions.<\/td><\/tr>\n            <tr><td>Reversed bending \/ roller bending \/ torsion testing<\/td><td>Mechanical parameters<\/td><td>Confirms suitability for reel, roller and multi-plane direction change duty.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"divider\"><span>III<\/span><hr><span class=\"caption\">Cable construction<\/span><\/div>\n      <h2>3. Construction Analysis: Class FS Conductors, EPR Field Control, Split Earths and the Protected Optical Element<\/h2>\n      <p>The construction follows the proven architecture of high mechanical stress medium voltage reeling cables, with one decisive addition: the third interstice, which in a standard (N)TSCGEWOEU would carry the third split earth conductor, is occupied by the protected fibre-optic element. The protective earth function is concentrated into two larger split conductors in the remaining two interstices \u2014 hence the <strong>2&#215;25\/2, 2&#215;35\/2, 2&#215;50\/2 &#8230; 2&#215;150\/2<\/strong> earth notation in the size list instead of the familiar 3x&#8230;\/3.<\/p>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 1 \u2014 Power conductors: very finely stranded copper, tinned, class FS<\/div>\n        <div class=\"layer-text\">Three power conductors of very finely stranded tinned copper, class FS. The extra-fine stranding is the foundation of reeling flexibility; tinning protects the strands against corrosion in humid, saline port atmospheres and stabilises long-term contact resistance.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 2 \u2014 Inner semi-conducting layer: semi-conductive EPR<\/div>\n        <div class=\"layer-text\">A semi-conductive EPR layer over each conductor smooths the conductor surface electric field, suppressing local field concentration at strand edges \u2014 the first half of the medium voltage field control system.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 3 \u2014 Core insulation: EPR rubber, PROTOLON HS class, special compound &gt; 3GI3<\/div>\n        <div class=\"layer-text\">High-stress EPR insulation dimensioned for the 6\/10 (12) kV system. EPR retains elasticity at low temperatures and resists the repeated flexing that would crack stiffer insulation systems in reeling duty.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 4 \u2014 Outer semi-conducting layer: semi-conductive NBR, easy-strip<\/div>\n        <div class=\"layer-text\">The easy-strip semi-conductive NBR layer completes the field control around each core and peels cleanly during medium voltage termination \u2014 a practical detail that directly affects the quality and speed of on-site MV jointing and termination work.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 5 \u2014 Three-core assembly with two split earth conductors<\/div>\n        <div class=\"layer-text\">The three insulated cores are laid up with two split protective earth conductors of tinned class FS copper occupying two of the three interstices (e.g. 2&#215;35\/2). Splitting the earth keeps the assembly round and the bending behaviour symmetrical.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 6 \u2014 Optical element 24E9LWL in the third interstice<\/div>\n        <div class=\"layer-text\">A protected optical unit with 24 singlemode E9 fibres sits in the third interstice. The unit is mechanically decoupled from the surrounding structure so that cable elongation under dynamic tension is not transferred one-to-one into fibre strain, and the interstice position shields the glass from direct radial roller pressure.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 7 \u2014 Inner sheath: PCP rubber, PROTOFIRM class, sandwich EPR\/CR<\/div>\n        <div class=\"layer-text\">The sandwich inner sheath locks the cores, earths and optical element into a stable geometry, preventing internal migration of elements during reeling, roller churning and torsion.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 8 \u2014 Reinforcement: polyester braiding<\/div>\n        <div class=\"layer-text\">An open polyester braid between the sheaths carries torsional and dynamic tensile loads and preserves the cross-section under the \u00b125\u00b0\/m torsion rule \u2014 protecting both the copper lay-up and the optical element from twist-induced deformation.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 9 \u2014 Outer sheath: PCP rubber, PROTOFIRM class, special compound &gt; 5GM5<\/div>\n        <div class=\"layer-text\">The chloroprene-based outer sheath delivers the abrasion, tear, oil, ozone, UV and seawater resistance that determines real service life on reels, rollers and concrete quay surfaces.<\/div>\n      <\/div>\n\n      <div class=\"note\">\n        <h4>Why the fibres live in the interstice<\/h4>\n        <p><strong>Engineering argument:<\/strong> in an opto-power reeling cable, the most fragile element is not copper but glass. Copper yields and recovers; glass fractures at strain levels far below copper&#8217;s elastic limit, and even sub-critical strain shows up immediately as attenuation. Placing the optical unit in the interstice between the three cores puts it in the most geometrically protected position of the cross-section \u2014 surrounded on all sides by compliant insulated cores that absorb radial roller pressure \u2014 while the strain-decoupled unit design keeps fibre elongation below the proof-test margin during 30 N\/mm\u00b2 dynamic tension events. The hybrid cable is therefore not &#8220;a power cable with fibres added&#8221;; it is a structure engineered around the survival of the glass.<\/p>\n      <\/div>\n\n      <div class=\"divider\"><span>IV<\/span><hr><span class=\"caption\">Electrical and thermal parameters<\/span><\/div>\n      <h2>4. Electrical and Thermal Parameters: 6\/10 (12) kV, 17 kV Test Voltage, 90\u00b0C Conductor Temperature<\/h2>\n      <p>The cable is rated U0\/U (Um) = 6\/10 (12) kV with a nominal voltage U of 10000 V and an AC test voltage of 17 kV, in line with the established values of the 6\/10 kV class in this reeling cable family. Maximum conductor temperature is 90\u00b0C in continuous operation and 250\u00b0C under short circuit. The fixed installation ambient range is -50\u00b0C to +80\u00b0C; for flexible (moving) operation the range is -35\u00b0C to +80\u00b0C.<\/p>\n\n      <div class=\"table-scroll\">\n        <table>\n          <thead>\n            <tr>\n              <th>Parameter<\/th>\n              <th>Value<\/th>\n              <th>Engineering interpretation<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>Rated voltage U0\/U (Um)<\/td><td>6\/10 (12) kV<\/td><td>Suited to 10 kV class medium voltage mobile power systems.<\/td><\/tr>\n            <tr><td>Test voltage<\/td><td>17 kV AC<\/td><td>Verification level of the 6\/10 kV insulation system.<\/td><\/tr>\n            <tr><td>Nominal voltage U<\/td><td>10000 V<\/td><td>Corresponds to 10 kV distribution levels common on STS and RMG cranes.<\/td><\/tr>\n            <tr><td>Max. conductor temperature<\/td><td>90\u00b0C<\/td><td>Continuous operation limit of the EPR insulation system.<\/td><\/tr>\n            <tr><td>Max. short-circuit temperature<\/td><td>250\u00b0C<\/td><td>Basis for short-time thermal withstand verification.<\/td><\/tr>\n            <tr><td>Ambient, fixed installation<\/td><td>-50\u00b0C to +80\u00b0C<\/td><td>For static runs and fixed cable sections.<\/td><\/tr>\n            <tr><td>Ambient, flexible operation<\/td><td>-35\u00b0C to +80\u00b0C<\/td><td>The verification boundary for dynamic reel, roller and travel operation.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"note\">\n        <h4>Medium voltage insight<\/h4>\n        <p><strong>Engineering argument:<\/strong> a 6\/10 kV reeling cable is not &#8220;a low voltage cable with thicker insulation&#8221;. The semi-conductive field control layers, the easy-strip screen interface and the termination workmanship determine long-term partial-discharge behaviour, and on a reeling cable every one of these interfaces is also a mechanical component that flexes thousands of times per year. Selection therefore always has to verify the electrical system (voltage, test voltage, termination method) and the mechanical system (tension, bending, torsion) together \u2014 neither alone is sufficient.<\/p>\n      <\/div>\n\n      <div class=\"divider\"><span>V<\/span><hr><span class=\"caption\">The optical subsystem<\/span><\/div>\n      <h2>5. The Optical Subsystem: Why 24 Singlemode E9 Fibres, and What They Replace<\/h2>\n      <p>The choice of <strong>singlemode E9 fibre (9\/125 \u00b5m class, ITU-T G.652 family)<\/strong> rather than multimode or copper communication pairs is a deliberate engineering decision with three independent justifications.<\/p>\n\n      <p><strong>First, electromagnetic immunity.<\/strong> Optical fibre is fully dielectric. Copper communication pairs laid inside a medium voltage cable would run centimetres from cores switching hundreds of amperes through variable-frequency drives \u2014 a worst-case environment for induced interference, requiring screening, isolation transformers and still suffering bandwidth and distance limits. Glass simply does not participate in the electromagnetic environment, and it additionally provides galvanic isolation between the moving machine and the shore-side network, eliminating earth-loop and transferred-potential issues across the link.<\/p>\n\n      <p><strong>Second, bandwidth-distance product.<\/strong> Singlemode E9 fibre supports crane runs of any realistic length \u2014 and onward terminal backbone distances of kilometres \u2014 at 1310\/1550 nm with low attenuation and no modal bandwidth ceiling. Multimode fibre would work on a short crane run today, but limits link speed upgrades tomorrow; singlemode makes the reeling cable the last component anyone needs to touch when the terminal upgrades from 1 Gbit\/s to 10, 25 or 100 Gbit\/s optics.<\/p>\n\n      <p><strong>Third, fibre count as redundancy and headroom.<\/strong> A modern automated crane typically consumes fibres in pairs: redundant PLC\/drive rings, CCTV and OCR cameras, remote operation video, access control, condition monitoring. Twenty-four fibres allow dual-path redundancy, dark-fibre spares for future systems and immediate recovery capacity if individual fibres are damaged at terminations \u2014 without ever opening the cable.<\/p>\n\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>Criterion<\/th>\n              <th>Copper communication pairs<\/th>\n              <th>Multimode fibre (50\/125)<\/th>\n              <th>Singlemode E9 (this cable)<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>EMI sensitivity next to MV cores<\/td><td>High \u2014 needs screening, still limited<\/td><td>None (dielectric)<\/td><td>None (dielectric)<\/td><\/tr>\n            <tr><td>Galvanic isolation crane \u2194 shore<\/td><td>No<\/td><td>Yes<\/td><td>Yes<\/td><\/tr>\n            <tr><td>Bandwidth-distance product<\/td><td>Low \u2014 Mbit\/s class over crane runs<\/td><td>Medium \u2014 modal bandwidth limited<\/td><td>Effectively unlimited for crane-scale links<\/td><\/tr>\n            <tr><td>Onward connection to terminal backbone<\/td><td>Requires media conversion<\/td><td>Often requires conversion to SM backbone<\/td><td>Direct splice to singlemode backbone<\/td><\/tr>\n            <tr><td>Upgrade path (10\/25\/100 Gbit\/s)<\/td><td>No<\/td><td>Restricted<\/td><td>Yes \u2014 change optics, keep cable<\/td><\/tr>\n            <tr><td>Long-term role in the cable<\/td><td>Legacy<\/td><td>Transitional<\/td><td>Future-proof standard<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <h3>5.1 Terminating the optical element on a reeling system<\/h3>\n      <p>On a motorized reel, the power cores terminate through slip rings; the fibres terminate through a <strong>fibre-optic rotary joint (FORJ)<\/strong> mounted on the reel axis, or \u2014 on some reel designs \u2014 through a free inner length with a splice box on the drum. Both ends of the optical element are normally fusion-spliced into splice cassettes and patched to the crane and shore networks with standard singlemode connectors. The practical design rules are: respect the cable&#8217;s moving bending radius everywhere the fibres travel, provide strain-free routing of the breakout, and keep an attenuation budget reserve for the FORJ and splices when calculating the optical link.<\/p>\n\n      <div class=\"formula\">\n        Optical Link Budget (per fibre) =\n        Transmitter Power \u2212 Receiver Sensitivity\n        \u2265 Fibre Attenuation \u00d7 Length + FORJ Insertion Loss + Splice Losses + Connector Losses + Ageing \/ Repair Margin\n      <\/div>\n\n      <div class=\"divider\"><span>VI<\/span><hr><span class=\"caption\">Chemical and environmental resistance<\/span><\/div>\n      <h2>6. Chemical and Environmental Performance: Oil, Ozone, UV and Seawater<\/h2>\n      <p>Port and terminal duty exposes a reeling cable to sunlight, rain, salt mist, seawater splash, hydraulic and lubricating oils, ozone from nearby electrical equipment and continuous mechanical abrasion \u2014 simultaneously. The chloroprene-based PROTOFIRM-class outer sheath (special compound &gt; 5GM5) is the component that converts laboratory ratings into service life under this combined exposure.<\/p>\n\n      <div class=\"table-scroll\">\n        <table>\n          <thead>\n            <tr>\n              <th>Environmental property<\/th>\n              <th>Status<\/th>\n              <th>Engineering value<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>Oil resistance<\/td><td>Yes (IEC 60811-404 class testing)<\/td><td>Withstands hydraulic oil, gear oil and industrial contamination on quays and machine houses.<\/td><\/tr>\n            <tr><td>Ozone resistance<\/td><td>Yes<\/td><td>Prevents sheath cracking near MV switchgear and drives.<\/td><\/tr>\n            <tr><td>UV resistance<\/td><td>Yes<\/td><td>Long-term outdoor exposure on open quay and stockyard equipment.<\/td><\/tr>\n            <tr><td>Seawater resistance<\/td><td>Yes<\/td><td>Quay edge, splash zone and salt-mist atmospheres.<\/td><\/tr>\n            <tr><td>Flame retardance<\/td><td>Yes (U designation)<\/td><td>No flame propagation along the cable route.<\/td><\/tr>\n            <tr><td>Outer sheath compound<\/td><td>PCP, PROTOFIRM class, &gt; 5GM5<\/td><td>The abrasion and tear resistance basis of reeling service life.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"divider\"><span>VII<\/span><hr><span class=\"caption\">Mechanical parameters<\/span><\/div>\n      <h2>7. Mechanical Parameters: \u00b125\u00b0\/m Torsion, 20\/30 N\/mm\u00b2 Tensile Rules, VDE 0298-3 Bending Radii<\/h2>\n      <p>The mechanical rules of the family apply: permissible torsional stress \u00b125\u00b0\/m; permanent tensile rule 20 N\/mm\u00b2 static and 30 N\/mm\u00b2 dynamic, referred to the total power core cross-section. Gantry reeling operation carries no general speed restriction; for travel speeds above 240 m\/min, consultation with the cable manufacturer is recommended. Bending radii follow VDE 0298-3: 6\u00d7D for fixed installation, 10\u00d7D for moving operation, and a minimum of 20\u00d7D between S-type direction changes.<\/p>\n\n      <div class=\"table-scroll\">\n        <table>\n          <thead>\n            <tr>\n              <th>Mechanical parameter<\/th>\n              <th>Value \/ rule<\/th>\n              <th>Engineering significance<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>Torsional stress<\/td><td>\u00b125\u00b0\/m<\/td><td>Covers multi-plane direction changes and reel-induced twist; also protects the optical element from twist deformation.<\/td><\/tr>\n            <tr><td>Static tensile rule<\/td><td>20 N\/mm\u00b2<\/td><td>Continuous operation and normal tension verification.<\/td><\/tr>\n            <tr><td>Dynamic tensile rule<\/td><td>30 N\/mm\u00b2<\/td><td>Starting, braking, acceleration and dynamic shock verification.<\/td><\/tr>\n            <tr><td>Gantry reeling speed<\/td><td>No general restriction<\/td><td>High-speed systems still require project-level verification.<\/td><\/tr>\n            <tr><td>Above 240 m\/min<\/td><td>Consult the cable manufacturer<\/td><td>Ultra-high-speed reels need manufacturer-level confirmation.<\/td><\/tr>\n            <tr><td>Bending radius, fixed<\/td><td>6 \u00d7 D<\/td><td>For static routing sections.<\/td><\/tr>\n            <tr><td>Bending radius, moving<\/td><td>10 \u00d7 D<\/td><td>For reel, roller and dynamic travel sections \u2014 also the protection rule for fibre attenuation.<\/td><\/tr>\n            <tr><td>S-type direction change spacing<\/td><td>20 \u00d7 D minimum<\/td><td>For multi-roller, multi-plane guidance systems.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"formula\">\n        XPRT-LWL Mechanical Suitability =\n        Dynamic Tensile Load + Torsional Stress + Reeling Speed + Roller Bending + Reversed Bending + S-Type Direction Distance + Outer Sheath Abrasion Resistance + Optical Strain Decoupling\n      <\/div>\n\n      <div class=\"note\">\n        <h4>One bending rule, two failure mechanisms<\/h4>\n        <p><strong>Engineering argument:<\/strong> on a power-only reeling cable, an undersized roller shortens life slowly through sheath and insulation fatigue. On an opto-power cable, the same undersized roller shows up immediately as optical attenuation \u2014 macrobending loss in singlemode fibre rises steeply once the bend radius falls below the design value. The 10\u00d7D moving radius is therefore not a conservative convenience; it is the simultaneous protection rule for thirty-year copper life and day-one optical performance, and it should be enforced at every sheave, roller and reel flange in the system.<\/p>\n      <\/div>\n\n      <div class=\"divider\"><span>VIII<\/span><hr><span class=\"caption\">Basic cable properties<\/span><\/div>\n      <h2>8. Dimensional Range: From 3&#215;25+2&#215;25\/2 +1x(24E9LWL) to 3&#215;300+2&#215;150\/2 +1x(24E9LWL)<\/h2>\n      <p>The 6\/10 kV XPRT-LWL range spans power core sizes from 25 mm\u00b2 to 300 mm\u00b2, covering the full power spectrum from auxiliary mobile machines to the largest ship-to-shore cranes. Every size carries the same 24-fibre singlemode element, so data capability is constant across the range while power capability scales with cross-section. Across the range, the maximum outer diameter doubles (44.3 mm to 89.2 mm) while weight grows by a factor of about 5.7 (2800 to 15880 kg\/km) \u2014 a reminder that for large sizes, cable self-weight on long lifts becomes a first-order term in the tension calculation.<\/p>\n\n      <div class=\"table-scroll wide\">\n        <table>\n          <thead>\n            <tr>\n              <th>Basic construction<\/th>\n              <th>SAP code<\/th>\n              <th>External code<\/th>\n              <th>Conductor diameter mm<\/th>\n              <th>Cable diameter min mm<\/th>\n              <th>Cable diameter max mm<\/th>\n              <th>Cable weight kg\/km<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>3&#215;25+2&#215;25\/2 +1x(24E9LWL)<\/td><td>20470343<\/td><td>\u2014<\/td><td>7.1<\/td><td>41.3<\/td><td>44.3<\/td><td>2800<\/td><\/tr>\n            <tr><td>3&#215;35+2&#215;25\/2 +1x(24E9LWL)<\/td><td>20470342<\/td><td>\u2014<\/td><td>8.3<\/td><td>43.1<\/td><td>46.1<\/td><td>3150<\/td><\/tr>\n            <tr><td>3&#215;50+2&#215;25\/2 +1x(24E9LWL)<\/td><td>20470341<\/td><td>\u2014<\/td><td>9.9<\/td><td>46.0<\/td><td>49.0<\/td><td>3800<\/td><\/tr>\n            <tr><td>3&#215;70+2&#215;35\/2 +1x(24E9LWL)<\/td><td>20460299<\/td><td>5DK4618<\/td><td>11.8<\/td><td>52.0<\/td><td>55.0<\/td><td>5000<\/td><\/tr>\n            <tr><td>3&#215;95+2&#215;50\/2 +1x(24E9LWL)<\/td><td>\u2014<\/td><td>\u2014<\/td><td>13.8<\/td><td>56.1<\/td><td>60.1<\/td><td>6300<\/td><\/tr>\n            <tr><td>3&#215;120+2&#215;70\/2 +1x(24E9LWL)<\/td><td>\u2014<\/td><td>\u2014<\/td><td>15.4<\/td><td>60.9<\/td><td>64.9<\/td><td>7660<\/td><\/tr>\n            <tr><td>3&#215;150+2&#215;70\/2 +1x(24E9LWL)<\/td><td>20478571<\/td><td>\u2014<\/td><td>17.2<\/td><td>63.2<\/td><td>67.2<\/td><td>8700<\/td><\/tr>\n            <tr><td>3&#215;185+2&#215;95\/2 +1x(24E9LWL)<\/td><td>\u2014<\/td><td>\u2014<\/td><td>19.0<\/td><td>69.3<\/td><td>73.3<\/td><td>10690<\/td><\/tr>\n            <tr><td>3&#215;240+2&#215;120\/2 +1x(24E9LWL)<\/td><td>\u2014<\/td><td>\u2014<\/td><td>21.8<\/td><td>76.7<\/td><td>80.7<\/td><td>13410<\/td><\/tr>\n            <tr><td>3&#215;300+2&#215;150\/2 +1x(24E9LWL)<\/td><td>\u2014<\/td><td>\u2014<\/td><td>24.4<\/td><td>84.2<\/td><td>89.2<\/td><td>15880<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"divider\"><span>IX<\/span><hr><span class=\"caption\">Derived electrical and mechanical properties<\/span><\/div>\n      <h2>9. Derived Selection Table: Tensile Limits, Moving Bending Radii, Conductor Resistance and Ampacity<\/h2>\n      <p>For project pre-selection, the table below applies the published family rules to each size: maximum tensile force = 20 N\/mm\u00b2 \u00d7 total power core cross-section; maximum tensile force during acceleration = 30 N\/mm\u00b2 \u00d7 total power core cross-section; minimum moving bending radius = 10 \u00d7 maximum cable diameter; conductor resistance per IEC 60228 for class 5\/6 tinned copper; current-carrying capacity per VDE 0298-4 Table 15 (30\u00b0C ambient, rubber cable in air). Final project values are always confirmed against the issued datasheet for the specific construction.<\/p>\n\n      <div class=\"table-scroll wide\">\n        <table>\n          <thead>\n            <tr>\n              <th>Basic construction<\/th>\n              <th>Max tensile force N<\/th>\n              <th>Max tensile during acceleration N<\/th>\n              <th>Min moving bending radius mm<\/th>\n              <th>Conductor resistance 20\u00b0C \u03a9\/km<\/th>\n              <th>Current-carrying capacity A<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>3&#215;25+2&#215;25\/2 +1x(24E9LWL)<\/td><td>1500<\/td><td>2250<\/td><td>443<\/td><td>0.795<\/td><td>139<\/td><\/tr>\n            <tr><td>3&#215;35+2&#215;25\/2 +1x(24E9LWL)<\/td><td>2100<\/td><td>3150<\/td><td>461<\/td><td>0.565<\/td><td>172<\/td><\/tr>\n            <tr><td>3&#215;50+2&#215;25\/2 +1x(24E9LWL)<\/td><td>3000<\/td><td>4500<\/td><td>490<\/td><td>0.393<\/td><td>215<\/td><\/tr>\n            <tr><td>3&#215;70+2&#215;35\/2 +1x(24E9LWL)<\/td><td>4200<\/td><td>6300<\/td><td>550<\/td><td>0.277<\/td><td>265<\/td><\/tr>\n            <tr><td>3&#215;95+2&#215;50\/2 +1x(24E9LWL)<\/td><td>5700<\/td><td>8550<\/td><td>601<\/td><td>0.210<\/td><td>319<\/td><\/tr>\n            <tr><td>3&#215;120+2&#215;70\/2 +1x(24E9LWL)<\/td><td>7200<\/td><td>10800<\/td><td>649<\/td><td>0.164<\/td><td>371<\/td><\/tr>\n            <tr><td>3&#215;150+2&#215;70\/2 +1x(24E9LWL)<\/td><td>9000<\/td><td>13500<\/td><td>672<\/td><td>0.132<\/td><td>428<\/td><\/tr>\n            <tr><td>3&#215;185+2&#215;95\/2 +1x(24E9LWL)<\/td><td>11100<\/td><td>16650<\/td><td>733<\/td><td>0.108<\/td><td>488<\/td><\/tr>\n            <tr><td>3&#215;240+2&#215;120\/2 +1x(24E9LWL)<\/td><td>14400<\/td><td>21600<\/td><td>807<\/td><td>0.0817<\/td><td>574<\/td><\/tr>\n            <tr><td>3&#215;300+2&#215;150\/2 +1x(24E9LWL)<\/td><td>18000<\/td><td>27000<\/td><td>892<\/td><td>0.0654<\/td><td>660<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"formula\">\n        Specification Selection =\n        Voltage 6\/10kV + Load Current + Conductor Resistance + Cable Weight + Tensile Force + Dynamic Tensile Force + Moving Bending Radius + Reeling Speed + Roller Path + Optical Link Budget\n      <\/div>\n\n      <div class=\"divider\"><span>X<\/span><hr><span class=\"caption\">Comparative analysis<\/span><\/div>\n      <h2>10. Comparative Analysis: Hybrid vs Standard Power Cable, and One Reel vs Two<\/h2>\n\n      <h3>10.1 (N)TSKCGEWOEU XPRT-LWL vs standard (N)TSCGEWOEU 6\/10 kV<\/h3>\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>Comparison item<\/th>\n              <th>Standard (N)TSCGEWOEU 6\/10kV<\/th>\n              <th>PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10kV<\/th>\n              <th>Engineering reading<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>Earth conductor arrangement<\/td><td>3 split earths in 3 interstices (x\/3)<\/td><td>2 split earths in 2 interstices (x\/2)<\/td><td>The earth function is concentrated into two larger conductors to free one interstice.<\/td><\/tr>\n            <tr><td>Third interstice content<\/td><td>Third split earth conductor<\/td><td>Protected 24E9LWL optical element<\/td><td>The defining structural difference \u2014 and the source of the K in the designation.<\/td><\/tr>\n            <tr><td>Data capability<\/td><td>None<\/td><td>24 singlemode fibres<\/td><td>Automation, CCTV, remote operation and TOS links travel inside the power cable.<\/td><\/tr>\n            <tr><td>MV system, insulation, field control<\/td><td>6\/10 (12) kV, EPR, semi-con layers<\/td><td>6\/10 (12) kV, EPR, semi-con layers<\/td><td>The medium voltage system is identical \u2014 termination practice carries over.<\/td><\/tr>\n            <tr><td>Mechanical rules<\/td><td>\u00b125\u00b0\/m, 20\/30 N\/mm\u00b2, 10\u00d7D moving<\/td><td>\u00b125\u00b0\/m, 20\/30 N\/mm\u00b2, 10\u00d7D moving<\/td><td>The hybrid retains the full high-to-extreme mechanical duty class.<\/td><\/tr>\n            <tr><td>Termination scope<\/td><td>MV terminations only<\/td><td>MV terminations + FO splicing \/ FORJ<\/td><td>The hybrid adds an optical workstream to installation and maintenance planning.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <h3>10.2 One combined reel vs two separate reeling systems<\/h3>\n      <p>The alternative to a hybrid cable is a second, independent fibre-optic reeling cable with its own reel, drive, guidance and slip-ring\/FORJ assembly. The comparison below summarises the system-level trade-off that crane builders and terminal engineers actually decide on.<\/p>\n\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>System criterion<\/th>\n              <th>Two separate reels (power + FO)<\/th>\n              <th>One XPRT-LWL hybrid reel<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>Reels, drives, guidance systems<\/td><td>2 of each \u2014 duplicated procurement and mounting space<\/td><td>1 of each<\/td><\/tr>\n            <tr><td>Synchronization<\/td><td>Two reels must track the same travel profile without tension conflicts<\/td><td>Not required \u2014 one cable, one tension control<\/td><\/tr>\n            <tr><td>Moving failure points<\/td><td>Doubled (two cables, two reel drives, two guidance paths)<\/td><td>Minimised<\/td><\/tr>\n            <tr><td>Inspection and maintenance objects<\/td><td>Two reeling systems on every inspection plan<\/td><td>One reeling system<\/td><\/tr>\n            <tr><td>Spare cable stocking<\/td><td>Two cable types, two reels of spares<\/td><td>One cable type<\/td><\/tr>\n            <tr><td>Single-point-of-failure consideration<\/td><td>Power and data fail independently<\/td><td>One cable carries both \u2014 mitigated by 24-fibre redundancy and disciplined cable management<\/td><\/tr>\n            <tr><td>Replacement event<\/td><td>Cables replaced on independent schedules<\/td><td>One replacement renews power and data simultaneously<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"note\">\n        <h4>Honest counter-argument<\/h4>\n        <p><strong>Engineering argument:<\/strong> the hybrid concentrates risk \u2014 mechanical destruction of the one cable interrupts both power and communication. The engineering response is threefold: the cable is built to the highest mechanical duty class of the family; the 24-fibre count provides internal redundancy against partial optical damage; and on a crane that loses its power cable, the machine stops anyway \u2014 a surviving separate data cable on a dead crane has limited operational value. For most crane applications, the consolidation argument therefore dominates, which is why the hybrid architecture has become the reference solution for automated and remotely operated cranes.<\/p>\n      <\/div>\n\n      <h3>10.3 Boundary check against the 8.7\/15 kV reeling family data<\/h3>\n      <p>Reading the 6\/10 kV XPRT-LWL dimensional data against the 8.7\/15 kV (N)TSCGEWOEU family data discussed in this article series gives a useful directional check \u2014 noting that the two designs differ in both voltage class and interstice content, so this is a trend comparison, not a like-for-like one.<\/p>\n\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>Power core size<\/th>\n              <th>6\/10kV XPRT-LWL: max OD mm \/ weight kg\/km<\/th>\n              <th>8.7\/15kV power-only: max OD mm \/ weight kg\/km<\/th>\n              <th>Reading<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>3&#215;70<\/td><td>55.0 \/ 5000<\/td><td>56.0 \/ 5160<\/td><td>Thinner 6\/10 kV insulation outweighs the added optical element.<\/td><\/tr>\n            <tr><td>3&#215;150<\/td><td>67.2 \/ 8700<\/td><td>69.9 \/ 8630<\/td><td>Weights converge \u2014 the optical unit and earth arrangement offset the insulation saving.<\/td><\/tr>\n            <tr><td>3&#215;240<\/td><td>80.7 \/ 13410<\/td><td>81.3 \/ 13300<\/td><td>Near parity in both diameter and weight.<\/td><\/tr>\n            <tr><td>3&#215;300<\/td><td>89.2 \/ 15880<\/td><td>89.2 \/ 16350<\/td><td>Identical OD; the 15 kV insulation wall dominates weight at the top of the range.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <p>The practical conclusion for reel and structure designers: adding a 24-fibre optical subsystem inside the 6\/10 kV cable costs essentially nothing in diameter and weight compared with stepping the same construction up one voltage class \u2014 the reel, sheave and counterweight design space is barely touched by the data capability.<\/p>\n\n      <div class=\"divider\"><span>XI<\/span><hr><span class=\"caption\">Selection framework<\/span><\/div>\n      <h2>11. How to Select a PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV Class Cable<\/h2>\n      <p>Selecting an opto-power reeling cable means verifying three systems at once: the medium voltage power system, the mechanical reeling system and the optical communication system. Cross-section and ampacity alone are never sufficient.<\/p>\n\n      <div class=\"table-scroll medium\">\n        <table>\n          <thead>\n            <tr>\n              <th>Selection dimension<\/th>\n              <th>Data to confirm<\/th>\n              <th>Decision it drives<\/th>\n            <\/tr>\n          <\/thead>\n          <tbody>\n            <tr><td>System voltage<\/td><td>Is the supply a 6\/10 kV system with Um within 12 kV?<\/td><td>Confirms the 6\/10 (12) kV class applies; higher systems need the 8.7\/15 kV family.<\/td><\/tr>\n            <tr><td>Load current<\/td><td>Continuous current, duty cycle, ambient temperature, installation method.<\/td><td>Selects the 25\u2013300 mm\u00b2 cross-section.<\/td><\/tr>\n            <tr><td>Travel speed<\/td><td>Gantry reeling speed; whether it exceeds 240 m\/min.<\/td><td>Above 240 m\/min, manufacturer consultation is recommended.<\/td><\/tr>\n            <tr><td>Dynamic tension<\/td><td>Starting, braking, acceleration, reel tension and cable self-weight on the lift.<\/td><td>Checked against max tensile and acceleration tensile values per size.<\/td><\/tr>\n            <tr><td>Torsion path<\/td><td>Multi-plane direction changes and accumulated twist.<\/td><td>Verified against the \u00b125\u00b0\/m rule.<\/td><\/tr>\n            <tr><td>Bending geometry<\/td><td>Reel core diameter, sheave diameters, roller pitch vs cable OD.<\/td><td>6\u00d7D fixed, 10\u00d7D moving, 20\u00d7D between S-type direction changes.<\/td><\/tr>\n            <tr><td>Environment<\/td><td>Oil, ozone, UV, seawater, salt mist, outdoor exposure.<\/td><td>Confirms the PROTOFIRM-class PCP &gt; 5GM5 sheath suitability.<\/td><\/tr>\n            <tr><td>Low temperature<\/td><td>Minimum temperatures of fixed and moving sections.<\/td><td>Verify fixed sections at -50\u00b0C and moving operation at -35\u00b0C.<\/td><\/tr>\n            <tr><td>MV termination<\/td><td>Semi-con stripping, screen treatment, earthing, stress control.<\/td><td>Easy-strip semi-conductive NBR supports reliable field termination.<\/td><\/tr>\n            <tr><td>Optical system<\/td><td>Fibre demand, redundancy concept, FORJ\/splice losses, link budget.<\/td><td>Confirms 24\u00d7E9 capacity and the end-to-end attenuation budget.<\/td><\/tr>\n          <\/tbody>\n        <\/table>\n      <\/div>\n\n      <div class=\"divider\"><span>XII<\/span><hr><span class=\"caption\">Engineer FAQ<\/span><\/div>\n      <h2>12. Frequently Asked Engineering Questions<\/h2>\n\n      <div class=\"qa\">\n        <h4>Question 1 \u2014 What is PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV?<\/h4>\n        <p><strong>Answer:<\/strong> It is a flexible 6\/10 (12) kV medium voltage reeling cable for high to extreme mechanical stresses, with an integrated optical element of 24 singlemode E9 fibres. It supplies medium voltage power, protective earth and a fibre-optic data backbone to fast-moving container cranes and large mobile equipment from a single motorized reel.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Question 2 \u2014 What does 24E9LWL mean in the construction code?<\/h4>\n        <p><strong>Answer:<\/strong> 24 is the fibre count; E9 identifies singlemode fibre of the 9\/125 \u00b5m class (ITU-T G.652 family); LWL is the German abbreviation for Lichtwellenleiter \u2014 optical fibre. So 1x(24E9LWL) means one protected optical unit containing 24 singlemode fibres.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Question 3 \u2014 Why integrate fibres into the medium voltage cable instead of running a separate fibre-optic reeling cable?<\/h4>\n        <p><strong>Answer:<\/strong> One hybrid reel replaces two complete reeling systems: one reel, one drive, one guidance path, one inspection object and one spare cable type instead of two of each, with no synchronization problem between independent reels. Optical fibre is dielectric and EMI-immune, so it coexists with the medium voltage cores without any interference penalty.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Question 4 \u2014 What bending radii apply, and do the fibres change them?<\/h4>\n        <p><strong>Answer:<\/strong> The family rules per VDE 0298-3 apply: 6\u00d7D fixed, 10\u00d7D moving, 20\u00d7D between S-type direction changes. The optical element is designed to live within these same limits \u2014 but the limits become doubly important, because an undersized roller produces measurable macrobending attenuation in the fibres long before it produces visible damage to the sheath.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Question 5 \u2014 How is the optical element terminated on a motorized reel?<\/h4>\n        <p><strong>Answer:<\/strong> The power cores terminate through the reel slip-ring assembly; the fibres pass through a fibre-optic rotary joint (FORJ) on the reel axis or, depending on reel design, through a free inner length to a drum-mounted splice box. Both ends are fusion-spliced into splice cassettes and patched onward with standard singlemode connectors. FORJ and splice losses must be included in the optical link budget.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Question 6 \u2014 What is the structural difference from a standard (N)TSCGEWOEU 6\/10kV?<\/h4>\n        <p><strong>Answer:<\/strong> In the standard cable, three split earth conductors fill the three interstices (x\/3 notation). In the XPRT-LWL hybrid, the earth is concentrated into two split conductors in two interstices (x\/2 notation) and the third interstice carries the protected 24-fibre optical element. The medium voltage insulation system, field control layers and mechanical duty class are the same.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Question 7 \u2014 Can it operate at high travel speeds and low temperatures?<\/h4>\n        <p><strong>Answer:<\/strong> Gantry reeling operation has no general speed restriction; above 240 m\/min, manufacturer consultation is recommended so that reel tension, sheave geometry and acceleration profiles can be verified. The flexible operation boundary is -35\u00b0C ambient (fixed sections -50\u00b0C); for arctic-class projects below this boundary, the design should be confirmed with the manufacturer at specification stage.<\/p>\n      <\/div>\n\n      <div class=\"success\">\n        <h4>Feichun Engineering View<\/h4>\n        <p>PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV represents the consolidation logic of modern crane electrification: 6\/10 (12) kV medium voltage power, split protective earth and 24 singlemode E9 optical fibres engineered into one reeling cable rated for high to extreme mechanical stress. Its construction \u2014 very finely stranded tinned class FS conductors, semi-conductive EPR field control, high-stress EPR insulation, easy-strip semi-conductive NBR, two split earths plus a strain-decoupled optical element in the interstices, sandwich PCP inner sheath, polyester anti-torsion braid and PCP &gt; 5GM5 outer sheath \u2014 keeps the full \u00b125\u00b0\/m torsion and 20\/30 N\/mm\u00b2 tensile capability of the family while adding an EMI-immune, future-proof data backbone at almost zero cost in diameter and weight. For STS, RMG and RTG-E cranes, ship unloaders and automated terminals, selection should verify the power system (voltage, 17 kV test level, ampacity), the mechanical system (dynamic tension, reeling speed, 10\u00d7D moving radius, S-type spacing, torsion, low temperature, sheath environment) and the optical system (fibre demand, FORJ and splice losses, link budget) together \u2014 because in an opto-power reeling cable, all three systems share one cross-section and one service life.<\/p>\n      <\/div>\n    <\/main>\n  <\/div>\n\n  <footer>\n    <div class=\"container\">\n      <h4>Anhui Feichun Special Cable Co., Ltd. \u2014 Opto-Power Medium Voltage Reeling Cable Engineering for High to Extreme Mechanical Stress<\/h4>\n      <p>Anhui Feichun Special Cable Co., Ltd. supports OEM manufacturers, port machinery suppliers, container crane manufacturers, ship unloader and bulk handling equipment builders, terminal automation integrators and industrial users requiring 6\/10kV medium voltage reeling cables with integrated singlemode optical fibres, fibre-optic hybrid crane cable systems, PROTOLON XPRT-type cable alternatives, PCP sheathed reeling cables, polyester reinforced anti-torsion cables and technical documentation for international crane, port and mining machinery projects.<\/p>\n      <div class=\"contact\">\n        <p><strong>Feichun Engineering Contact<\/strong><br>\n        Telephone: +86 13855123218<br>\n        Email: <a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/p>\n      <\/div>\n      <p>Feichun supports customers requiring 6\/10kV opto-power reeling cable solutions, combined power and fibre-optic crane cable selection, STS \/ RMG \/ RTG-E crane cable projects, gantry reeling operation cable systems, dynamic tensile force evaluation, torsional stress evaluation, moving bending radius calculation, optical link budget review and marine outdoor environment cable engineering.<\/p>\n      <div class=\"docid\">Document Reference: FEICHUN-PROTOLON-XPRT-LWL-NTSKCGEWOEU-6-10KV-OPTO-POWER-MV-REELING-CABLE-EN-V1 \u00b7 PROTOLON XPRT-LWL \u00b7 (N)TSKCGEWOEU \u00b7 6\/10 (12) kV \u00b7 17kV Test Voltage \u00b7 24\u00d7E9 Singlemode LWL Element \u00b7 EPR Insulation \u00b7 PROTOFIRM-Class PCP Sheath \u00b7 Polyester Braiding \u00b7 Static 20N\/mm\u00b2 \u00b7 Dynamic 30N\/mm\u00b2 \u00b7 \u00b125\u00b0\/m Torsion \u00b7 10D Moving Bending Radius \u00b7 20D S-Type Directional Changes \u00b7 Feichun Engineering<\/div>\n    <\/div>\n  <\/footer>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"PROTOLON XPRT-LWL (N)TSKCGEWOEU 6\/10KV is a flexible medium voltage opto-power reeling cable designed for high to extreme mechanical stresses: high travel speeds, dynamic tensile loads, multiple changes of direction into different planes, churning on running over rollers and torsional stress. Its defining feature is the integration of a protected optical element with 24 singlemode E9 fibres \u2014 designated 24E9LWL \u2014 into a 6\/10 kV three-core rubber reeling cable with split earth conductors. The result is a single cable on a single reel that simultaneously carries medium voltage power, the protective earth function and a high-bandwidth, EMI-immune fibre-optic data backbone for crane automation, CCTV, remote operation and terminal operating system connectivity on fast-moving container cranes and large mobile equipment.","protected":false},"author":1,"featured_media":11896,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,56],"tags":[60414,65,56896,60428,60427,53138,60471,60429,60470,60413,179,48,43976,12167,996,60479,16,145,60478,60477,60472,12122,60468,60467,16198,60466,17,2606,2607,2782,60469,60473,2604],"class_list":["post-17440","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-reeling-cable","tag-35c","tag-ntskcgewoeu","tag-25-m","tag-10xd-2","tag-17kv","tag-20xd","tag-24-singlemode-fibres","tag-240m-min","tag-24e9lwl","tag-30n-mm","tag-5gm5","tag-6-10kv","tag-class-fs","tag-combined-power-data-cable","tag-container-crane-cable","tag-crane-automation-cable-2","tag-din-vde-0250","tag-epr-insulation","tag-feichun-cables-2","tag-fiber-optic-rotary-joint","tag-forj","tag-high-mechanical-stress-reeling-cable","tag-medium-voltage-reeling-cable-with-fiber-optics","tag-opto-power-reeling-cable","tag-pcp-sheath","tag-protolon-xprt-lwl","tag-reeling-cable","tag-rmg-crane-cable","tag-rtg-crane-cable","tag-ship-unloader-cable","tag-singlemode-reeling-cable","tag-split-earth-conductors","tag-sts-crane-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/17440","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=17440"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/17440\/revisions"}],"predecessor-version":[{"id":17443,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/17440\/revisions\/17443"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/11896"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=17440"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=17440"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=17440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}