{"id":17108,"date":"2026-06-08T14:42:33","date_gmt":"2026-06-08T06:42:33","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=17108"},"modified":"2026-06-08T14:42:36","modified_gmt":"2026-06-08T06:42:36","slug":"mining-grade-composite-fo-cable-type-409-s-as-nzs-standard-iecex-secure-mine-site-data-power","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/mining-grade-composite-fo-cable-type-409-s-as-nzs-standard-iecex-secure-mine-site-data-power\/","title":{"rendered":"Mining Grade Composite FO Cable | Type 409-S | AS\/NZS Standard | IECEx | Secure Mine Site Data\/Power"},"content":{"rendered":"\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n  <meta charset=\"UTF-8\">\n  <meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0, viewport-fit=cover\">\n  <meta name=\"description\" content=\"Technical article for Anhui Feichun Special Cable Co., Ltd. Mining Grade Composite FO Cable Type 409-S for secure mine site data and power, AS\/NZS standard project documentation, Type 409 flexible feeder cable architecture, IECEx hazardous-area termination interface, EPR insulation, screened power cores, pilot monitoring, earth continuity, fibre optic module, optical attenuation, EMI immunity, SCADA, automation, CCTV, PLC and mine communication networks.\">\n  <meta name=\"keywords\" content=\"Mining Grade Composite FO Cable, Type 409-S, Type 409 fibre optic mining cable, AS\/NZS mining cable, AS\/NZS 2802 composite mining cable, IECEx mining cable, composite power fibre optic cable, secure mine site data power, mining SCADA cable, underground mining communication cable, fibre optic power composite cable, Feichun Type 409-S\">\n  <meta property=\"og:title\" content=\"Mining Grade Composite FO Cable | Type 409-S | AS\/NZS Standard | IECEx | Secure Mine Site Data\/Power\">\n  <meta property=\"og:description\" content=\"Feichun Type 409-S mining grade composite power and fibre optic cable technical article for secure mine site data, screened power, pilot monitoring, earth continuity, automation networks and IECEx termination interface review.\">\n  <title>Mining Grade Composite FO Cable | Type 409-S | AS\/NZS Standard | IECEx | Secure Mine Site Data\/Power<\/title>\n\n  <style>\n    :root{\n      --bg:#0d1520;--panel:#162338;--panel2:#1d2e49;--line:#38506f;\n      --text:#eaf1f8;--muted:#b9c7d8;--orange:#ff6b35;--blue:#1e88e5;\n      --green:#00d084;--yellow:#ffd700;--cyan:#4ecdc4;--red:#ff1744;\n    }\n    *{box-sizing:border-box;margin:0;padding:0}\n    body{font-family:\"Segoe UI\",Arial,sans-serif;background:var(--bg);color:var(--text);line-height:1.75;overflow-x:hidden}\n    .container{max-width:1040px;margin:0 auto;padding:0 22px}\n    .hero{padding:70px 20px;background:\n      radial-gradient(circle at 12% 20%,rgba(255,107,53,.34),transparent 34%),\n      radial-gradient(circle at 84% 18%,rgba(30,136,229,.28),transparent 32%),\n      radial-gradient(circle at 70% 88%,rgba(0,208,132,.18),transparent 34%),\n      linear-gradient(135deg,#07111d 0%,#122943 42%,#241a08 100%);\n      text-align:center;border-bottom:3px solid var(--orange)}\n    .badges{display:flex;justify-content:center;gap:10px;flex-wrap:wrap;margin-bottom:26px}\n    .badge{padding:9px 16px;border-radius:4px;font-size:11px;text-transform:uppercase;letter-spacing:1px;font-weight:800;border:1px solid rgba(255,255,255,.22)}\n    .b1{background:var(--orange)}.b2{background:var(--blue)}.b3{background:var(--green);color:#061018}.b4{background:var(--yellow);color:#061018}\n    h1{font-size:44px;line-height:1.15;margin:0 auto 20px;max-width:980px;font-family:Georgia,serif;text-shadow:0 3px 12px rgba(0,0,0,.35)}\n    .hero p{max-width:940px;margin:0 auto;color:rgba(255,255,255,.88);font-size:16px}\n    .meta{display:flex;justify-content:center;gap:18px;flex-wrap:wrap;margin-top:28px;color:rgba(255,255,255,.78);font-size:12px}\n    .cards{display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:20px;margin:48px 0}\n    .card{background:var(--panel);border:1px solid var(--line);border-left:6px solid var(--orange);border-radius:7px;padding:22px}\n    .card:nth-child(2){border-left-color:var(--blue)}.card:nth-child(3){border-left-color:var(--green)}.card:nth-child(4){border-left-color:var(--yellow)}.card:nth-child(5){border-left-color:var(--cyan)}.card:nth-child(6){border-left-color:var(--red)}\n    .label{font-size:11px;color:var(--muted);text-transform:uppercase;letter-spacing:.8px;font-weight:800;margin-bottom:8px}\n    .value{font-family:Georgia,serif;font-size:30px;font-weight:800;color:var(--orange);line-height:1.1}\n    .card:nth-child(2) .value{color:var(--blue)}.card:nth-child(3) .value{color:var(--green)}.card:nth-child(4) .value{color:var(--yellow)}.card:nth-child(5) .value{color:var(--cyan)}.card:nth-child(6) .value{color:var(--red)}\n    .unit{font-size:12px;color:var(--muted);margin-top:8px}\n    main{padding:12px 0 60px}\n    h2{font-family:Georgia,serif;font-size:34px;color:var(--orange);line-height:1.25;margin:56px 0 22px;padding-bottom:15px;border-bottom:3px solid var(--yellow)}\n    h3{font-family:Georgia,serif;font-size:25px;color:var(--green);margin:38px 0 16px;line-height:1.32}\n    h4{font-size:15px;color:var(--orange);margin:24px 0 12px;text-transform:uppercase;letter-spacing:.7px}\n    p,li{color:var(--muted);font-size:15px}\n    p{margin:0 0 20px}\n    ul,ol{margin:18px 0 26px 28px}\n    li{margin-bottom:10px}\n    strong{color:var(--orange)}\n    a{color:var(--cyan);text-decoration:none}\n    a:hover{text-decoration:underline}\n    .divider{display:flex;align-items:center;gap:16px;margin:58px 0 12px}\n    .divider span:first-child{background:var(--orange);padding:7px 15px;border-radius:4px;font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase}\n    .divider hr{flex:1;border:none;border-top:1px solid var(--line)}\n    .divider .caption{color:var(--muted);font-size:13px}\n    .note{background:linear-gradient(120deg,rgba(255,107,53,.14),rgba(30,136,229,.12));border-left:6px solid var(--orange);border-right:2px solid var(--blue);padding:24px;border-radius:7px;margin:28px 0}\n    .success{background:linear-gradient(135deg,#00a965,#00d084);color:#fff;border-radius:8px;padding:25px;margin:30px 0;box-shadow:0 8px 28px rgba(0,208,132,.18)}\n    .success p,.warning p{color:rgba(255,255,255,.92)}\n    .warning{background:linear-gradient(135deg,#ad1735,#ff1744);color:#fff;border-radius:8px;padding:25px;margin:30px 0;box-shadow:0 8px 28px rgba(255,23,68,.18)}\n    table{width:100%;border-collapse:collapse;background:var(--panel);margin:30px 0;border:1px solid var(--line);display:block;overflow-x:auto;font-size:13px}\n    th{background:#0a1520;color:var(--orange);font-size:12px;text-align:left;padding:12px;border-bottom:2px solid var(--line);white-space:nowrap}\n    td{padding:12px;border-bottom:1px solid var(--line);color:var(--muted);vertical-align:top}\n    tr:hover td{background:rgba(255,107,53,.06)}\n    .layer{background:var(--panel);border:1px solid var(--line);border-left:5px solid var(--orange);padding:18px 20px;border-radius:6px;margin:16px 0}\n    .layer:nth-of-type(2n){border-left-color:var(--blue)}\n    .layer-title{font-weight:800;color:var(--text);font-size:16px;margin-bottom:7px}\n    .layer-text{color:var(--muted);font-size:13px}\n    .formula{background:#0a1520;border:1px solid var(--line);border-left:5px solid var(--cyan);border-radius:7px;padding:18px 20px;margin:22px 0;color:var(--muted);font-family:Consolas,Monaco,monospace;font-size:13px;overflow-x:auto}\n    .qa{background:var(--panel2);border:1px solid var(--line);border-left:5px solid var(--green);border-radius:7px;padding:22px;margin:24px 0}\n    .qa h4{margin-top:0;color:var(--green)}\n    .rfq{background:rgba(30,136,229,.09);border:1px solid var(--line);border-left:5px solid var(--blue);border-radius:7px;padding:22px;margin:28px 0;color:var(--muted);font-style:italic}\n    footer{background:#07111d;border-top:3px solid var(--orange);padding:48px 20px;margin-top:40px}\n    footer h4{font-family:Georgia,serif;font-size:24px;text-transform:none;letter-spacing:0;color:var(--orange)}\n    .contact{background:var(--panel);border:1px solid var(--line);border-left:5px solid var(--orange);border-radius:7px;padding:20px;margin:22px 0;color:var(--muted)}\n    .docid{text-align:center;color:#70839b;font-size:11px;margin-top:28px;padding-top:22px;border-top:1px solid var(--line)}\n    @media(max-width:640px){h1{font-size:31px}h2{font-size:27px}h3{font-size:22px}.hero{padding:48px 16px}.value{font-size:27px}}\n  <\/style>\n<\/head>\n\n<body>\n  <section class=\"hero\">\n    <div class=\"container\">\n      <div class=\"badges\">\n        <span class=\"badge b1\">Type 409-S<\/span>\n        <span class=\"badge b2\">Composite FO + Power<\/span>\n        <span class=\"badge b3\">Secure Mine Data<\/span>\n        <span class=\"badge b4\">IECEx Interface<\/span>\n      <\/div>\n      <h1>Mining Grade Composite FO Cable | Type 409-S | AS\/NZS Standard | IECEx | Secure Mine Site Data\/Power<\/h1>\n      <p>Feichun Type 409-S Mining Grade Composite FO Cable is a project-engineered power and fibre optic composite cable for mine sites that require power transmission, pilot \/ earth monitoring and secure high-bandwidth data communication in one rugged mining-grade cable. It is developed for mobile mining machinery, pump stations, conveyor transfer points, remote substations, autonomous equipment, telemetry systems, cameras, PLC \/ SCADA networks and harsh mine-site data \/ power routes where electromagnetic noise, mechanical damage and downtime must be controlled together.<\/p>\n      <div class=\"meta\">\n        <span>\u2713 Type 409 power architecture with integrated FO module<\/span>\n        <span>\u2713 AS\/NZS standard project documentation support<\/span>\n        <span>\u2713 Screened power cores + pilot \/ earth monitoring<\/span>\n        <span>\u2713 Single-mode or multimode optical fibre options<\/span>\n        <span>\u2713 IECEx cable gland \/ coupler \/ junction interface review<\/span>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <div class=\"container\">\n    <div class=\"cards\">\n      <div class=\"card\"><div class=\"label\">Composite Type<\/div><div class=\"value\">409-S<\/div><div class=\"unit\">Project designation for power + fibre optic mining cable<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Power Function<\/div><div class=\"value\">MV\/LV<\/div><div class=\"unit\">Voltage class selected by mine equipment requirement<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Data Function<\/div><div class=\"value\">FO<\/div><div class=\"unit\">Optical fibre for secure high-bandwidth mine communication<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Monitoring<\/div><div class=\"value\">Pilot<\/div><div class=\"unit\">Earth continuity, permissive and interlock circuits<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Environment<\/div><div class=\"value\">Mine<\/div><div class=\"unit\">Abrasion, oil, water, dust, vibration and mechanical abuse<\/div><\/div>\n      <div class=\"card\"><div class=\"label\">Hazardous Area<\/div><div class=\"value\">IECEx<\/div><div class=\"unit\">Termination and enclosure interface verification<\/div><\/div>\n    <\/div>\n\n    <main>\n      <div class=\"divider\"><span>I<\/span><hr><span class=\"caption\">Engineering positioning<\/span><\/div>\n      <h2>1. Why Mine Sites Need Composite Fibre Optic + Power Cable<\/h2>\n      <p>Modern mine sites are no longer powered only by electricity. They also depend on data: machine status, remote operation, vibration monitoring, pump telemetry, conveyor protection, CCTV, access control, gas monitoring, PLC communication, SCADA supervision and autonomous equipment control. In this environment, separating power and communication into two independent cable routes can increase installation time, route congestion, failure points and maintenance exposure.<\/p>\n\n      <p>Feichun Type 409-S is designed as a <strong>mining-grade composite cable platform<\/strong>: the power section supplies equipment, the pilot \/ earth system supports protection logic, and the fibre optic module provides a high-speed, EMI-resistant communication path. The result is not simply \u201ca power cable with fibre added\u201d; it is a combined electromechanical and optical transmission system for harsh mine environments.<\/p>\n\n      <div class=\"note\">\n        <h4>Professional naming clarification<\/h4>\n        <p><strong>Type 409-S<\/strong> should be presented as a Feichun project designation for a Type 409-style mining power cable architecture with an integrated fibre optic module. Because \u201cType 409-S\u201d is not always listed as an independent public AS\/NZS cable type, the strongest wording is: <strong>\u201cType 409-S composite FO mining cable based on Type 409 power-cable engineering, supplied with AS\/NZS standard construction mapping and project-specific fibre optic integration documentation.\u201d<\/strong><\/p>\n      <\/div>\n\n      <h3>1.1 Mine-Site Problems Solved by Type 409-S<\/h3>\n      <table>\n        <thead>\n          <tr>\n            <th>Mine-Site Problem<\/th>\n            <th>Operational Risk<\/th>\n            <th>Type 409-S Engineering Response<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Power and communication routes are installed separately<\/td>\n            <td>More cable trays, more clamps, more route congestion and higher installation labor<\/td>\n            <td>Composite power + fibre construction reduces routing complexity and supports one coordinated cable path<\/td>\n          <\/tr>\n          <tr>\n            <td>High electromagnetic noise near VFDs, motors and MV equipment<\/td>\n            <td>Copper communication links can suffer noise, ground loops and unstable data transmission<\/td>\n            <td>Optical fibre provides EMI-immune data transmission inside the same mining-grade cable envelope<\/td>\n          <\/tr>\n          <tr>\n            <td>Remote equipment requires power, monitoring and data<\/td>\n            <td>Multiple cable systems increase failure points and commissioning time<\/td>\n            <td>Screened power cores, pilot \/ earth monitoring and FO module support integrated machine infrastructure<\/td>\n          <\/tr>\n          <tr>\n            <td>Harsh floor, wet areas and moving equipment damage data cables<\/td>\n            <td>Network dropouts, camera loss, SCADA alarms and unplanned inspection work<\/td>\n            <td>Mining-grade sheath, reinforcement and protected FO tube improve mechanical survivability<\/td>\n          <\/tr>\n          <tr>\n            <td>Cyber-secure mine networks need stable physical media<\/td>\n            <td>Wireless interference, poor coverage or unsecured local access points can reduce reliability<\/td>\n            <td>Fibre optic backbone supports physically routed, high-bandwidth and low-latency mine communication<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"divider\"><span>II<\/span><hr><span class=\"caption\">AS\/NZS and project compliance<\/span><\/div>\n      <h2>2. AS\/NZS Standard Context: Use Construction Mapping, Not Over-Claiming<\/h2>\n      <p>Type 409 power-cable architecture is commonly used for flexible feeder supply to machinery and is more suitable for trailing duty than high-speed reeling. In Australian mining projects, AS\/NZS 2802 is a key reference for flexible reeling and trailing cables for surface mining, non-coal underground mining and general movable plant power supply. The selected standard must match the actual mine type, voltage class, route, movement profile and authority requirement.<\/p>\n\n      <p>For a composite FO cable, the AS\/NZS review should cover both the power-cable construction and the added fibre optic module. The fibre optic addition must not compromise power-core screening, pilot continuity, earth-fault performance, cable geometry, bending radius, sheath integrity or termination compatibility.<\/p>\n\n      <div class=\"warning\">\n        <h4>Compliance Notice<\/h4>\n        <p>Do not state that every Type 409-S composite FO cable is automatically certified to every AS\/NZS or IECEx application. Recommended wording: <strong>\u201cType 409-S supplied with AS\/NZS standard construction mapping, Type 409 power-cable design basis, fibre optic integration drawing and IECEx hazardous-area termination interface documentation subject to project certificate scope and mine authority approval.\u201d<\/strong><\/p>\n      <\/div>\n\n      <h3>2.1 Documentation Matrix for Mine Approval<\/h3>\n      <table>\n        <thead>\n          <tr>\n            <th>Document<\/th>\n            <th>What It Proves<\/th>\n            <th>Why Mine Engineers Need It<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Power cable construction drawing<\/td>\n            <td>Shows conductor, insulation, screen, earth, pilot and sheath structure<\/td>\n            <td>Required for AS\/NZS construction mapping and technical approval<\/td>\n          <\/tr>\n          <tr>\n            <td>FO module integration drawing<\/td>\n            <td>Shows fibre count, fibre type, tube design, strength member and placement<\/td>\n            <td>Confirms that the optical module will not damage cable geometry or bending performance<\/td>\n          <\/tr>\n          <tr>\n            <td>Electrical routine test report<\/td>\n            <td>Confirms conductor resistance, voltage withstand, insulation resistance and screen continuity<\/td>\n            <td>Supports incoming inspection and batch traceability<\/td>\n          <\/tr>\n          <tr>\n            <td>Optical test report<\/td>\n            <td>Confirms attenuation, continuity, OTDR trace and fibre identification<\/td>\n            <td>Required for SCADA, CCTV, PLC and mine network commissioning<\/td>\n          <\/tr>\n          <tr>\n            <td>IECEx termination interface file<\/td>\n            <td>Checks gland, coupler, junction box, FO breakout and enclosure compatibility<\/td>\n            <td>Important for hazardous-area installations and mine authority review<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"divider\"><span>III<\/span><hr><span class=\"caption\">Composite construction<\/span><\/div>\n      <h2>3. Type 409-S Construction: Power Core, Pilot\/Earth System and FO Module in One Cable<\/h2>\n      <p>A composite mine cable must be designed so that the electrical and optical systems can coexist without damaging each other. The power cores create heat, electromagnetic field and mechanical mass. The fibre optic module requires controlled bending, crush protection and moisture blocking. The sheath and reinforcement must protect both systems at the same time.<\/p>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 1 \u2014 Flexible Tinned Copper Power Conductors<\/div>\n        <div class=\"layer-text\">Flexible stranded tinned copper conductors provide current carrying and corrosion resistance for wet or contaminated mine environments. Conductor size is selected by voltage class, load current, starting current, voltage drop, short-circuit duty and route length.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 2 \u2014 EPR Insulation and Screened Power-Core System<\/div>\n        <div class=\"layer-text\">EPR insulation provides dielectric strength and flexibility. For medium-voltage versions, semiconductive conductor and insulation screens control electric stress and support stable screened-core operation.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 3 \u2014 Earth Conductors and Pilot Monitoring Core<\/div>\n        <div class=\"layer-text\">Earth conductors and pilot core support protective earthing, earth continuity monitoring, machine permissive circuits and trip logic. The pilot circuit should remain stable even when the cable is bent, dragged or relocated.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 4 \u2014 Fibre Optic Module<\/div>\n        <div class=\"layer-text\">The FO module can be designed with single-mode OS2 fibre for long-distance backbone links or multimode OM3 \/ OM4 fibre for shorter high-bandwidth machine and plant networks. The module should include water-blocking, crush protection, strain relief and controlled fibre excess length to prevent micro-bending loss.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 5 \u2014 Separation, Cushioning and Strength Members<\/div>\n        <div class=\"layer-text\">Cushioning layers and non-metallic strength members help isolate the optical module from power-core movement, compression and tensile load. This is critical because fibre loss can increase after repeated bending or localized crushing.<\/div>\n      <\/div>\n\n      <div class=\"layer\">\n        <div class=\"layer-title\">Layer 6 \u2014 Heavy-Duty Mining Sheath<\/div>\n        <div class=\"layer-text\">The outer sheath is selected for abrasion resistance, oil resistance, water resistance, flame retardancy, tear resistance and mine-floor durability. Sheath diameter must also match glands, clamps, couplers, reels and cable handlers.<\/div>\n      <\/div>\n\n      <h3>3.1 Construction-to-Function Matrix<\/h3>\n      <table>\n        <thead>\n          <tr>\n            <th>Cable Element<\/th>\n            <th>Recommended Specification Language<\/th>\n            <th>Engineering Function<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Power conductors<\/td>\n            <td>Flexible stranded tinned annealed copper conductors<\/td>\n            <td>Current transmission, bending endurance and corrosion resistance<\/td>\n          <\/tr>\n          <tr>\n            <td>Insulation<\/td>\n            <td>EPR elastomeric insulation with screened-core system according to voltage class<\/td>\n            <td>Dielectric strength, thermal stability and flexibility<\/td>\n          <\/tr>\n          <tr>\n            <td>Screen system<\/td>\n            <td>Semiconductive screens and metallic \/ composite screen as required<\/td>\n            <td>Electric field control, fault response and protective coordination<\/td>\n          <\/tr>\n          <tr>\n            <td>Pilot \/ earth system<\/td>\n            <td>Central pilot and earth conductors for monitoring and interlock circuits<\/td>\n            <td>Machine permissive, earth continuity and protective trip functions<\/td>\n          <\/tr>\n          <tr>\n            <td>FO module<\/td>\n            <td>Water-blocked optical fibre module with OS2 \/ OM3 \/ OM4 fibre options<\/td>\n            <td>High-bandwidth, low-latency and EMI-immune data transmission<\/td>\n          <\/tr>\n          <tr>\n            <td>Outer sheath<\/td>\n            <td>Heavy-duty flame-retardant PCP \/ CSP \/ project-specific mining sheath<\/td>\n            <td>Abrasion, oil, water, tear, UV and mechanical protection<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"divider\"><span>IV<\/span><hr><span class=\"caption\">Electrical and optical parameters<\/span><\/div>\n      <h2>4. Electrical and Optical Parameters That Must Be Specified Together<\/h2>\n      <p>For Type 409-S, electrical and optical parameters should be reviewed in one engineering package. A cable can pass electrical tests but fail optical attenuation after bending. It can also pass optical tests but be unsuitable for voltage drop, short-circuit duty or pilot relay performance. Both systems must be engineered together.<\/p>\n\n      <h3>4.1 Electrical Parameter Checklist<\/h3>\n      <table>\n        <thead>\n          <tr>\n            <th>Electrical Parameter<\/th>\n            <th>Engineering Meaning<\/th>\n            <th>Type 409-S Selection Impact<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Rated voltage Uo\/U<\/td>\n            <td>Defines phase-to-earth and phase-to-phase insulation stress<\/td>\n            <td>Controls insulation thickness, screen design, test voltage and termination type<\/td>\n          <\/tr>\n          <tr>\n            <td>Conductor cross-section<\/td>\n            <td>Determines ampacity and resistance<\/td>\n            <td>Affects heating, voltage drop, diameter, weight and bend radius<\/td>\n          <\/tr>\n          <tr>\n            <td>Voltage drop<\/td>\n            <td>Loss of voltage along the cable route<\/td>\n            <td>Important for pump starting, VFD operation and remote equipment stability<\/td>\n          <\/tr>\n          <tr>\n            <td>Short-circuit withstand<\/td>\n            <td>Ability to survive fault current before protection clears<\/td>\n            <td>Must be checked for conductors, screens and earth path<\/td>\n          <\/tr>\n          <tr>\n            <td>Pilot resistance<\/td>\n            <td>Resistance of monitoring circuit over full cable length<\/td>\n            <td>Affects machine permissive logic and earth-monitoring relay behavior<\/td>\n          <\/tr>\n          <tr>\n            <td>Capacitance and screen bonding<\/td>\n            <td>Important for long screened cables and relay settings<\/td>\n            <td>Can influence earth-leakage relay stability and nuisance tripping<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <h3>4.2 Optical Parameter Checklist<\/h3>\n      <table>\n        <thead>\n          <tr>\n            <th>Optical Parameter<\/th>\n            <th>Engineering Meaning<\/th>\n            <th>Mine Network Impact<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Fibre type<\/td>\n            <td>OS2 single-mode or OM3 \/ OM4 multimode<\/td>\n            <td>Determines link distance, bandwidth, transceiver type and network topology<\/td>\n          <\/tr>\n          <tr>\n            <td>Fibre count<\/td>\n            <td>Number of available optical cores<\/td>\n            <td>Supports redundancy, SCADA, CCTV, PLC, sensors and future expansion<\/td>\n          <\/tr>\n          <tr>\n            <td>Attenuation<\/td>\n            <td>Optical signal loss per cable length<\/td>\n            <td>Controls link budget and acceptable splice \/ connector count<\/td>\n          <\/tr>\n          <tr>\n            <td>Minimum bend radius<\/td>\n            <td>Mechanical limit to prevent fibre micro-bending<\/td>\n            <td>Must match reel, tray, cable handler and machine entry geometry<\/td>\n          <\/tr>\n          <tr>\n            <td>Crush resistance<\/td>\n            <td>Ability to preserve optical performance under mechanical load<\/td>\n            <td>Critical where the composite cable may be dragged, pressed or clamped<\/td>\n          <\/tr>\n          <tr>\n            <td>OTDR trace<\/td>\n            <td>Optical time-domain reflection test record<\/td>\n            <td>Provides baseline for commissioning and future fault location<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"formula\">\n        Composite cable design rule:<br>\n        Electrical rating + optical link budget + bending radius + crush resistance + termination interface must all pass together.<br><br>\n        A power cable that damages the FO module during bending is not a successful composite cable.\n      <\/div>\n\n      <div class=\"divider\"><span>V<\/span><hr><span class=\"caption\">Secure mine data \/ power architecture<\/span><\/div>\n      <h2>5. Secure Mine Site Data\/Power: What the Cable Can and Cannot Do<\/h2>\n      <p>Fibre optic communication improves physical network reliability because it is immune to electromagnetic interference and does not create ground-loop current between devices. This is valuable near VFDs, motors, switchgear, long cable routes and electrically noisy mine equipment. It also supports high-bandwidth data such as video, machine diagnostics, remote I\/O, automation traffic and SCADA communication.<\/p>\n\n      <p>However, cable design alone is not cybersecurity. A composite FO cable provides the physical data channel. Secure mine-site communication also requires network segmentation, managed switches, authentication, firewall policy, access control, OT cybersecurity procedures and maintenance discipline. The strongest technical wording is: <strong>\u201cType 409-S supports secure physical-layer data transmission; cybersecurity must be implemented at the network and control-system level.\u201d<\/strong><\/p>\n\n      <table>\n        <thead>\n          <tr>\n            <th>Mine Data Application<\/th>\n            <th>Why Fibre Helps<\/th>\n            <th>Design Check<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>SCADA and PLC communication<\/td>\n            <td>Stable low-latency backbone for control and monitoring<\/td>\n            <td>Confirm fibre type, protocol, switch location and redundancy<\/td>\n          <\/tr>\n          <tr>\n            <td>CCTV and machine vision<\/td>\n            <td>High bandwidth for remote video streams<\/td>\n            <td>Confirm link budget, camera count and connector loss<\/td>\n          <\/tr>\n          <tr>\n            <td>Pump and conveyor monitoring<\/td>\n            <td>Long-distance telemetry without copper noise issues<\/td>\n            <td>Confirm distance, fibre count and splice enclosure protection<\/td>\n          <\/tr>\n          <tr>\n            <td>Autonomous mining equipment<\/td>\n            <td>Reliable physical media for high-volume machine status data<\/td>\n            <td>Confirm movement profile, FO bend radius and cable handler design<\/td>\n          <\/tr>\n          <tr>\n            <td>Remote substations<\/td>\n            <td>Combines power route with optical communication route<\/td>\n            <td>Confirm electrical separation, bonding, cabinet entry and OTDR baseline<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"divider\"><span>VI<\/span><hr><span class=\"caption\">Comparison analysis<\/span><\/div>\n      <h2>6. Type 409-S Compared with Separate Power + Separate Fibre Routes<\/h2>\n      <p>The decision to use a composite power and fibre optic cable should be based on route risk, installation cost, network reliability, maintenance access and failure consequence. Composite cable is not always the best solution, but it becomes valuable when the mine wants a unified rugged route for power and data.<\/p>\n\n      <table>\n        <thead>\n          <tr>\n            <th>Solution<\/th>\n            <th>Main Strength<\/th>\n            <th>Main Limitation<\/th>\n            <th>Best-Fit Scenario<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Type 409-S composite FO cable<\/td>\n            <td>Power, monitoring and fibre data in one rugged mining cable<\/td>\n            <td>Requires careful termination, breakout and optical testing<\/td>\n            <td>Remote equipment, substations, pumps, conveyors and automated machinery<\/td>\n          <\/tr>\n          <tr>\n            <td>Separate power cable + separate fibre cable<\/td>\n            <td>Easier independent replacement and separation of systems<\/td>\n            <td>More routes, more supports, more installation work and more exposed cables<\/td>\n            <td>Large fixed plants with available tray space and separate maintenance teams<\/td>\n          <\/tr>\n          <tr>\n            <td>Power cable + copper data cable<\/td>\n            <td>Simple for short low-noise routes<\/td>\n            <td>More vulnerable to EMI, ground loops and distance limitations<\/td>\n            <td>Short local control circuits away from large motors and MV equipment<\/td>\n          <\/tr>\n          <tr>\n            <td>Wireless communication<\/td>\n            <td>No cable path for data route<\/td>\n            <td>Coverage, interference, obstruction and security must be managed<\/td>\n            <td>Mobile zones where physical cable is not practical<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <h3>6.1 When Composite FO Cable Is the Better Engineering Choice<\/h3>\n      <ul>\n        <li><strong>Long-distance data route:<\/strong> the mine needs stable high-bandwidth communication over a route already requiring power.<\/li>\n        <li><strong>High EMI environment:<\/strong> motors, VFDs, switchgear or MV feeders make copper data links unreliable.<\/li>\n        <li><strong>Route congestion:<\/strong> tray, tunnel, cable hooks or cable ladder space is limited.<\/li>\n        <li><strong>Remote maintenance:<\/strong> fewer separate cables reduce inspection complexity.<\/li>\n        <li><strong>Automation and monitoring:<\/strong> equipment requires power, pilot monitoring and real-time data together.<\/li>\n      <\/ul>\n\n      <div class=\"divider\"><span>VII<\/span><hr><span class=\"caption\">Field problems and engineering answers<\/span><\/div>\n      <h2>7. Field Problems and Engineering Answers for Composite FO Mining Cable<\/h2>\n      <p>Composite FO cables fail differently from ordinary power cables. A site may have perfect power continuity but poor optical performance; or excellent optical transmission but wrong gland sealing; or stable data but nuisance trips from pilot or earth-monitoring issues. The following table translates field symptoms into engineering causes and practical answers.<\/p>\n\n      <table>\n        <thead>\n          <tr>\n            <th>Field Problem<\/th>\n            <th>Likely Technical Cause<\/th>\n            <th>Engineering Answer<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Power is normal, but the network link drops during machine movement.<\/td>\n            <td>FO module is experiencing micro-bending, crush stress or excessive tensile load during cable movement.<\/td>\n            <td>Check OTDR trace while cable is bent, verify minimum bending radius, improve cable support and review FO module placement \/ cushioning.<\/td>\n          <\/tr>\n          <tr>\n            <td>Optical attenuation increases after installation.<\/td>\n            <td>Over-bending, tight clamps, poor splice handling, damaged connector or fibre compression inside the termination box.<\/td>\n            <td>Perform OTDR baseline comparison, inspect splice tray, loosen over-tight clamps and keep FO breakout inside controlled bend-radius limits.<\/td>\n          <\/tr>\n          <tr>\n            <td>IECEx inspection questions the composite cable entry.<\/td>\n            <td>Gland or enclosure certificate does not clearly address composite power + FO breakout, sheath OD or sealing method.<\/td>\n            <td>Provide cable OD, sheath material, gland range, barrier sealing method, FO breakout drawing and Ex interface statement for mine authority review.<\/td>\n          <\/tr>\n          <tr>\n            <td>Earth leakage trips occur after wet operation.<\/td>\n            <td>Sheath damage, poor gland sealing, water ingress or contamination at power termination.<\/td>\n            <td>Test insulation resistance, inspect gland sealing, check sheath cuts and keep FO breakout separate from wet power termination stress zones.<\/td>\n          <\/tr>\n          <tr>\n            <td>Pilot circuit trips but fibre communication remains active.<\/td>\n            <td>Pilot conductor or earth continuity path is damaged while optical fibre is still intact.<\/td>\n            <td>Measure pilot resistance, inspect pilot termination, check strain relief and verify pilot relay settings against total cable length.<\/td>\n          <\/tr>\n          <tr>\n            <td>Fibre link is stable in the workshop but unstable in the mine.<\/td>\n            <td>Mine installation adds bending, vibration, crush, moisture or connector contamination not present during factory testing.<\/td>\n            <td>Test after installation, clean connectors, inspect bend points and create an OTDR commissioning record for future comparison.<\/td>\n          <\/tr>\n          <tr>\n            <td>The cable is difficult to terminate because power and fibre exit at the same point.<\/td>\n            <td>Breakout length, gland position, cabinet space or splice box layout was not defined before manufacturing.<\/td>\n            <td>Specify FO breakout length, power termination length, gland type, splice enclosure location and cabinet entry geometry before production.<\/td>\n          <\/tr>\n          <tr>\n            <td>Data network is called \u201csecure\u201d but still fails cybersecurity audit.<\/td>\n            <td>The physical fibre route is secure, but network segmentation, access control and OT security policy were not implemented.<\/td>\n            <td>Use Type 409-S as the physical layer, then implement VLANs, firewalls, authentication, managed switches and mine OT cybersecurity procedures.<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"qa\">\n        <h4>Problem 1 \u2014 Can fibre optic cores be placed anywhere inside a mining power cable?<\/h4>\n        <p><strong>Answer:<\/strong> No. The FO module must be positioned where it avoids excessive compression, bending and thermal stress from the power cores. It requires cushioning, water blocking and controlled excess fibre length to reduce micro-bending loss.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Problem 2 \u2014 Does fibre optic communication make the whole composite cable intrinsically safe?<\/h4>\n        <p><strong>Answer:<\/strong> No. The optical fibre communication path is non-conductive and EMI-immune, but Type 409-S still contains power conductors. Hazardous-area compliance depends on the complete installation: cable, gland, coupler, enclosure, sealing, bonding and certificate scope.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Problem 3 \u2014 Why is OTDR testing important for composite mine cables?<\/h4>\n        <p><strong>Answer:<\/strong> OTDR testing creates a baseline record of optical attenuation and reflection points. If a mine later experiences network instability, the baseline helps locate fibre stress, splice loss, connector damage or crush-related attenuation.<\/p>\n      <\/div>\n\n      <div class=\"qa\">\n        <h4>Problem 4 \u2014 What is the biggest engineering risk when replacing separate fibre and power routes with one composite cable?<\/h4>\n        <p><strong>Answer:<\/strong> The biggest risk is termination planning. The mine must define where the power cores terminate, where the fibre breaks out, how the gland seals, how the screen bonds and how the FO splice box is protected before the cable is manufactured.<\/p>\n      <\/div>\n\n      <div class=\"divider\"><span>VIII<\/span><hr><span class=\"caption\">IECEx \/ ATEX termination interface<\/span><\/div>\n      <h2>8. IECEx \/ ATEX: Composite Cable Requires a Complete Entry-System Review<\/h2>\n      <p>For hazardous-area mine projects, IECEx \/ ATEX language should focus on the certified entry system. The cable gland, coupler, plug, junction box and enclosure entry must be compatible with the composite cable\u2019s outer diameter, sheath material, screen \/ earth bonding and FO breakout method.<\/p>\n\n      <table>\n        <thead>\n          <tr>\n            <th>Interface Item<\/th>\n            <th>Engineering Check<\/th>\n            <th>Risk if Ignored<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Cable outside diameter<\/td>\n            <td>Must fall within certified gland sealing range<\/td>\n            <td>Loss of sealing, mechanical retention or Ex installation integrity<\/td>\n          <\/tr>\n          <tr>\n            <td>Sheath material<\/td>\n            <td>Must be compatible with compression seal or barrier compound<\/td>\n            <td>Seal degradation, leakage path or cable pull-out<\/td>\n          <\/tr>\n          <tr>\n            <td>Screen \/ earth bonding<\/td>\n            <td>Must be continuous through gland, coupler and enclosure<\/td>\n            <td>Unsafe touch voltage or poor earth-fault response<\/td>\n          <\/tr>\n          <tr>\n            <td>FO breakout<\/td>\n            <td>Must maintain bend radius and environmental sealing<\/td>\n            <td>Optical loss, water ingress or failed inspection<\/td>\n          <\/tr>\n          <tr>\n            <td>Barrier seal requirement<\/td>\n            <td>Must match Ex d \/ Ex e \/ project-specific enclosure entry rules<\/td>\n            <td>Incorrect flameproof or increased-safety installation<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <div class=\"warning\">\n        <h4>IECEx \/ ATEX Wording Notice<\/h4>\n        <p>Recommended wording: <strong>\u201cIECEx \/ ATEX hazardous-area documentation available for cable gland, coupler, FO breakout, junction box and equipment-entry compatibility review, subject to the exact cable diameter, sheath material, gland certificate, enclosure protection concept and mine authority approval.\u201d<\/strong><\/p>\n      <\/div>\n\n      <div class=\"divider\"><span>IX<\/span><hr><span class=\"caption\">Ordering data and acceptance tests<\/span><\/div>\n      <h2>9. Data Required Before Feichun Can Confirm Type 409-S Specification<\/h2>\n      <p>A composite FO mining cable quotation should not be based on product name alone. Feichun should confirm the electrical system, optical network design, mine environment, movement profile, termination method and hazardous-area documentation requirement before finalizing the cable drawing.<\/p>\n\n      <table>\n        <thead>\n          <tr>\n            <th>Required Data<\/th>\n            <th>Why It Matters<\/th>\n            <th>Engineering Output<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>Rated voltage and conductor size<\/td>\n            <td>Defines power-core insulation, ampacity and voltage drop<\/td>\n            <td>Electrical construction and routine test plan<\/td>\n          <\/tr>\n          <tr>\n            <td>Load current and starting current<\/td>\n            <td>Controls heating, voltage drop and machine starting stability<\/td>\n            <td>Conductor cross-section and voltage-drop review<\/td>\n          <\/tr>\n          <tr>\n            <td>Pilot \/ earth monitoring requirement<\/td>\n            <td>Defines permissive circuit and earth-continuity logic<\/td>\n            <td>Pilot conductor, earth path and relay compatibility review<\/td>\n          <\/tr>\n          <tr>\n            <td>Fibre type and fibre count<\/td>\n            <td>Defines network distance, bandwidth and redundancy<\/td>\n            <td>OS2 \/ OM3 \/ OM4 selection and FO module design<\/td>\n          <\/tr>\n          <tr>\n            <td>Network equipment and protocol<\/td>\n            <td>Determines transceiver, link budget and connector plan<\/td>\n            <td>Optical attenuation and OTDR acceptance criteria<\/td>\n          <\/tr>\n          <tr>\n            <td>Route movement profile<\/td>\n            <td>Controls bending, dragging, tensile load and crush risk<\/td>\n            <td>Sheath, reinforcement, bend radius and FO protection design<\/td>\n          <\/tr>\n          <tr>\n            <td>Gland, coupler or junction box type<\/td>\n            <td>Controls OD, sealing, screen bonding and FO breakout<\/td>\n            <td>IECEx \/ ATEX termination interface documentation<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n\n      <h3>9.1 Site Acceptance Test Checklist<\/h3>\n      <ul>\n        <li><strong>Electrical tests:<\/strong> conductor resistance, insulation resistance, voltage withstand, screen continuity, earth continuity and pilot continuity.<\/li>\n        <li><strong>Optical tests:<\/strong> fibre identification, insertion loss, OTDR trace, attenuation comparison and connector inspection.<\/li>\n        <li><strong>Mechanical checks:<\/strong> cable OD, sheath condition, minimum bending radius, clamp pressure, cable route and FO breakout protection.<\/li>\n        <li><strong>Termination checks:<\/strong> gland sealing, screen bonding, earth lug, strain relief, splice tray radius and enclosure sealing.<\/li>\n        <li><strong>Documentation checks:<\/strong> AS\/NZS construction mapping, factory routine test report, optical test report, material data and IECEx interface review.<\/li>\n      <\/ul>\n\n      <div class=\"success\">\n        <h4>Feichun Type 409-S Technical Value Proposition<\/h4>\n        <p>Feichun Type 409-S Mining Grade Composite FO Cable is engineered for mine sites that need reliable power, protection monitoring and secure physical-layer data transmission in one rugged cable platform. By combining Type 409-style screened mining power architecture with protected fibre optic communication, Feichun helps mines reduce route complexity, improve EMI immunity, support automation and prepare stronger documentation for AS\/NZS and IECEx project review.<\/p>\n      <\/div>\n\n      <div class=\"divider\"><span>X<\/span><hr><span class=\"caption\">Specification wording<\/span><\/div>\n      <h2>10. Recommended Specification Language for Type 409-S Procurement<\/h2>\n      <div class=\"rfq\">\n        Supply Mining Grade Composite FO Cable Type 409-S for secure mine site data and power transmission. Cable shall be based on Type 409 mining feeder \/ trailing cable engineering and include flexible stranded tinned copper power conductors, EPR insulation, screened power-core construction according to voltage class, pilot and earth monitoring cores as required by the mine protection system, protected fibre optic module with OS2 single-mode or OM3 \/ OM4 multimode fibre options, water-blocking and crush-resistant optical tube design, reinforcement, and heavy-duty flame-retardant mining sheath. Supplier shall provide AS\/NZS standard construction mapping, electrical routine test report, optical attenuation and OTDR test report, cable diameter, bending radius, pulling tension, fibre breakout drawing, gland \/ coupler \/ junction box interface data and IECEx \/ ATEX hazardous-area termination documentation subject to project certificate scope.\n      <\/div>\n    <\/main>\n  <\/div>\n\n  <footer>\n    <div class=\"container\">\n      <h4>Anhui Feichun Special Cable Co., Ltd. \u2014 Type 409-S Mining Grade Composite FO Cable<\/h4>\n      <p>Anhui Feichun Special Cable Co., Ltd. supplies mining-grade composite power and fibre optic cables for secure mine site data \/ power applications, including mobile machinery, pump stations, conveyor systems, remote substations, CCTV, PLC \/ SCADA networks, automation systems and mine projects requiring AS\/NZS standard construction mapping and IECEx hazardous-area termination interface review.<\/p>\n      <div class=\"contact\">\n        <p><strong>Feichun Technical Contact<\/strong><br>\n        Telephone: +86 13855123218<br>\n        Email: <a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/p>\n      <\/div>\n      <p>For technical review, please provide voltage class, conductor cross-section, load current, cable length, movement profile, pilot \/ earth monitoring requirement, fibre type, fibre count, network distance, connector type, gland \/ coupler \/ junction box model, mine environment and IECEx \/ ATEX or mine authority documentation requirements.<\/p>\n      <div class=\"docid\">Document Reference: FEICHUN-MINING-GRADE-COMPOSITE-FO-CABLE-TYPE409S-ASNZS-STANDARD-IECEX-SECURE-MINE-SITE-DATA-POWER-EN-V1 \u00b7 Type 409-S Composite FO Cable \u00b7 Mining Power and Fibre Optic Cable \u00b7 AS\/NZS Standard Construction Mapping \u00b7 IECEx Interface Review \u00b7 Pilot Monitoring \u00b7 Earth Continuity \u00b7 EPR Insulation \u00b7 Secure Mine Data \u00b7 SCADA \u00b7 CCTV \u00b7 Automation<\/div>\n    <\/div>\n  <\/footer>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"Feichun Type 409-S Mining Grade Composite FO Cable is a project-engineered power and fibre optic composite cable for mine sites that require power transmission, pilot \/ earth monitoring and secure high-bandwidth data communication in one rugged mining-grade cable. It is developed for mobile mining machinery, pump stations, conveyor transfer points, remote substations, autonomous equipment, telemetry systems, cameras, PLC \/ SCADA networks and harsh mine-site data \/ power routes where electromagnetic noise, mechanical damage and downtime must be controlled together.","protected":false},"author":1,"featured_media":11980,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[222,46145,66],"tags":[],"class_list":["post-17108","post","type-post","status-publish","format-standard","has-post-thumbnail","category-as-nzs-1802-reeling-cables-for-underground-mining","category-as-nzs-1972-electric-cables-underground-coal-mines","category-common-problems-encountered-in-cable-applications","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/17108","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=17108"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/17108\/revisions"}],"predecessor-version":[{"id":17115,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/17108\/revisions\/17115"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/11980"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=17108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=17108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=17108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}