{"id":11756,"date":"2026-05-11T10:30:37","date_gmt":"2026-05-11T02:30:37","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=11756"},"modified":"2026-05-11T10:30:40","modified_gmt":"2026-05-11T02:30:40","slug":"type-fg7ocr-gaalflex-vfd","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/type-fg7ocr-gaalflex-vfd\/","title":{"rendered":"Type FG7(O)CR GAALFLEX\u00ae VFD"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Inverter, connection to frequency converters, 0,6\/1 kV<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"f1f0ef\" data-has-transparency=\"false\" style=\"--dominant-color: #f1f0ef;\" loading=\"lazy\" decoding=\"async\" width=\"845\" height=\"527\" sizes=\"auto, (max-width: 845px) 100vw, 845px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1405.avif\" alt=\"\" class=\"wp-image-11758 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1405.avif 845w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1405-300x187.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1405-768x479.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1405-400x249.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1405-800x499.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1405-832x519.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>GAALFLEX\u00ae VFD FG7(O)CR: 600V\/1000V European Standard Industrial Halogen-Free Variable Frequency Drive Cable with HEPR Rubber Insulation, Red Copper Braid-Only Shielding, PVC R2 Inner Sheath, Gray Special PVC Jacket, +250\u00b0C Short-Circuit Tolerance, 3-Phase Industrial Motor, 2.5\u2013300 mm\u00b2 Flexible Class 5, 8\u00d7D Bending Radius, Enhanced EN 50266-2-4\/IEC 60332-3-24 Flame Testing | European Halogen-Free Industrial VFD Cable<\/title>\n<meta name=\"description\" content=\"GAALFLEX\u00ae VFD FG7(O)CR: European standard 600V\/1000V (0.6\/1 kV) halogen-free variable frequency drive cable engineered for standard industrial frequency converter systems, industrial motor power distribution, and halogen-free applications featuring proprietary HEPR (halogen-free ethylene propylene rubber) insulation with low-smoke characteristics (non-building-code), PVC R2 type inner sheath providing electrical isolation and mechanical protection, red copper braid shielding (equal section \u226416 mm\u00b2 or \u226550% phase \u226516 mm\u00b2 for >25 mm\u00b2) without aluminum tape providing simplified EMI suppression, 600V\/1000V dual nominal voltage enabling European DIN VDE and international IEC specification, 3-phase + shield conductor configuration supporting industrial motor VFD systems, mm\u00b2 conductor range (2.5\u2013300 mm\u00b2) with flexible Class 5 red copper per IEC 60228 \/ DIN VDE 0295 enabling complete industrial motor specification including large motor applications, gray RAL 7035 special PVC compound outer sheath providing industrial standard protection, temperature range \u221215\u00b0C fixed\/0\u00b0C flexible minimum through +90\u00b0C maximum enabling standard industrial facilities, exceptional +250\u00b0C maximum short-circuit temperature enabling fault-condition tolerance, 8\u00d7D minimum bending radius supporting flexible installation, 4 kV test voltage per DIN VDE standard, comprehensive flame testing per DIN VDE 0482-265-2-1, EN 50265-2-1, IEC 60332-1-2 (vertical) plus enhanced EN 50266-2-4 \/ IEC 60332-3-24 (tray) testing ensuring industrial fire safety, EMC compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, RoHS and CE approved, and complete European standard industrial VFD infrastructure compliance enabling OEM frequency converter integration, industrial motor power distribution, standard-temperature industrial operation with halogen-free safety, and professional standard industrial variable-frequency motor drive system acceptance with exceptional short-circuit tolerance.&#8221; \/>\n<meta name=\"keywords\" content=\"VFD cable,600V,1000V,HEPR,halogen-free,copper braid,industrial standard,frequency converter,industrial motor,PVC inner sheath\" \/>\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<meta name=\"robots\" content=\"index,follow,max-image-preview:large,max-snippet:-1\" \/>\n<meta property=\"og:title\" content=\"GAALFLEX\u00ae VFD FG7(O)CR: HEPR Halogen-Free Copper Braid VFD Cable\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta name=\"article:published_time\" content=\"2026-05-09T00:00:00Z\" \/>\n<meta name=\"article:author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.feichuncables.com\/industrial-motors\/gaalflex-vfd-fg7ocr-hepr-copper-braid-industrial\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin \/>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\" \/>\n<style>\n:root{\n  --bg-body:#F7F5F1; --bg-surface:#FFFFFF; --bg-recessed:#F0E8E0; --bg-th:#5A4A4A; --bg-tr-alt:#F9F8F5;\n  --bg-callout-hepr:#D8E8F5; --bg-callout-braid:#E8D8E8; --bg-callout-inner:#E8E8D8; --bg-callout-shld:#D8E0D8;\n  --bg-callout-fire:#E8F0E0;\n  --c-body:#1B1F1D; --c-secondary:#454D4A; --c-tertiary:#727A76; --c-inverse:#FFFFFF;\n  --c-link:#2A5A8A; --c-hepr:#6A4A8A; --c-braid:#8A2A6A; --c-inner:#8A7A2A;\n  --c-shld:#2A8A4A; --c-fire:#6A8A2A;\n  --b-rule:#D4D0C8; --b-light:#E8E5DE; --b-accent:#2A5A8A; --b-table:#C4C0BA;\n  --sh-sm:0 1px 2px rgba(0,0,0,0.06); --sh-md:0 3px 12px rgba(0,0,0,0.08);\n  --badge-bg:#5A4A4A; --badge-c:#FFFFFF; --badge-hepr:#6A4A8A; --badge-braid:#8A2A6A;\n}\n@media(prefers-color-scheme:dark){\n  :root{\n    --bg-body:#0B0F0D; --bg-surface:#161A18; --bg-recessed:#0F1A10; --bg-th:#5A4A4A; --bg-tr-alt:#0F1211;\n    --bg-callout-hepr:#0A0A40; --bg-callout-braid:#1A0A1A; --bg-callout-inner:#1A1A0A; --bg-callout-shld:#0A1A0A;\n    --bg-callout-fire:#0A2A10;\n    --c-body:#E2E5E2; --c-secondary:#B3BAB6; --c-tertiary:#858D8A; --c-inverse:#0B0F0D;\n    --c-link:#6A98C8; --c-hepr:#A880E8; --c-braid:#E880C8; --c-inner:#E8D880;\n    --c-shld:#80D8A0; --c-fire:#B8D880;\n    --b-rule:#252D2A; --b-light:#1D2421; --b-accent:#6A98C8; --b-table:#232B28;\n  }\n}\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nhtml{font-size:16px;scroll-behavior:smooth}\nbody{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden;}\n.page-wrap{max-width:920px;margin:0 auto;padding:2.5rem 1.25rem 4rem}\n.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--c-link);position:relative;}\n.hdr::after{content:\"\";position:absolute;left:0;bottom:-2px;width:400px;height:2px;background:linear-gradient(90deg,#6A4A8A 0%,#8A2A6A 50%,#2A8A4A 100%);}\n.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem;}\n.hdr .badge.hepr{background:var(--badge-hepr)} .hdr .badge.braid{background:var(--badge-braid)}\n.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.4rem,3.3vw,2.05rem);line-height:1.24;margin-bottom:.7rem;letter-spacing:-.005em;color:var(--c-link);}\n.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.65;margin-bottom:.4rem;}\n.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary);}\n.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm);}\n.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-link);margin-bottom:.55rem;}\n.toc ol{list-style:none;counter-reset:tc;padding:0;columns:2;column-gap:1.5rem}\n.toc li{counter-increment:tc;margin-bottom:.28rem;break-inside:avoid}\n.toc li::before{content:counter(tc,decimal-leading-zero) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-braid);}\n.toc a{font-size:.82rem;color:var(--c-secondary);text-decoration:none;line-height:1.4;}\n.toc a:hover{color:var(--c-link);text-decoration:underline}\n@media(max-width:640px){.toc ol{columns:1}}\n.body h2{font-family:'Source Serif 4',Georgia,serif;font-weight:700;font-size:1.38rem;margin:3rem 0 .9rem;padding-bottom:.4rem;border-bottom:1px solid var(--b-light);color:var(--c-link);line-height:1.3;}\n.body h3{font-weight:600;font-size:1.06rem;margin:1.9rem 0 .55rem;color:var(--c-body);}\n.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify;hyphens:auto;}\n.body strong{font-weight:600;color:var(--c-body)}\n.hepr-em{color:var(--c-hepr);font-weight:600} .braid-em{color:var(--c-braid);font-weight:600} .inner-em{color:var(--c-inner);font-weight:600}\n.shld-em{color:var(--c-shld);font-weight:600} .fire-em{color:var(--c-fire);font-weight:600}\n.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-sm);}\n.tw table{width:100%;border-collapse:collapse;font-size:.83rem;line-height:1.45;min-width:720px;}\n.tw caption{text-align:left;font-weight:600;font-size:.76rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light);}\n.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.72rem;padding:.55rem .7rem;text-align:left;border-bottom:2px solid var(--c-link);}\n.tw tbody td{padding:.5rem .7rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top;}\n.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)} .tw tbody tr:hover{background:var(--bg-callout-hepr)}\n.tw tbody td:first-child{font-weight:500;color:var(--c-body)}\n.tw tbody td code{font-family:'IBM Plex Mono',monospace;font-size:.78rem;background:var(--bg-recessed);padding:.08em .35em;border-radius:3px;}\n.tw tbody td.num{font-family:'IBM Plex Mono',monospace;font-size:.79rem;text-align:right;}\n.tw tbody td.winner{background:var(--bg-callout-fire);color:var(--c-body);font-weight:600;}\n.note{padding:1rem 1.25rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent);}\n.note.hepr{background:var(--bg-callout-hepr);border-left-color:var(--c-hepr)}\n.note.braid{background:var(--bg-callout-braid);border-left-color:var(--c-braid)}\n.note.inner{background:var(--bg-callout-inner);border-left-color:var(--c-inner)}\n.note.shld{background:var(--bg-callout-shld);border-left-color:var(--c-shld)}\n.note.fire{background:var(--bg-callout-fire);border-left-color:var(--c-fire)}\n.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.35rem;}\n.note p{margin-bottom:.35rem}\n.spec-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(190px,1fr));gap:1rem;margin:1.5rem 0;}\n.spec-card{background:var(--bg-surface);border:1px solid var(--b-rule);border-top:3px solid var(--c-link);border-radius:4px;padding:1rem 1.1rem;}\n.spec-card.hepr{border-top-color:var(--c-hepr)}\n.spec-card.braid{border-top-color:var(--c-braid)}\n.spec-card.inner{border-top-color:var(--c-inner)}\n.spec-card.shld{border-top-color:var(--c-shld)}\n.spec-card.fire{border-top-color:var(--c-fire)}\n.spec-card .lab{font-size:.68rem;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.4rem;}\n.spec-card .val{font-family:'IBM Plex Mono',monospace;font-size:1.08rem;font-weight:600;color:var(--c-body);line-height:1.3;margin-bottom:.3rem;}\n.spec-card .des{font-size:.78rem;color:var(--c-secondary);line-height:1.45;}\n.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--c-link);}\n.refs h2{font-size:1.08rem;margin-bottom:.9rem}\n.rl{list-style:none;counter-reset:rf;padding:0}\n.rl li{counter-increment:rf;font-size:.79rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5;}\n.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.74rem;}\n.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.5rem;margin-top:2.5rem;}\n.contact h3{font-size:.98rem;margin-bottom:.7rem}\n.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem;}\n.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}\n.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem;}\n.ci a{color:var(--c-link);text-decoration:none} .ci a:hover{text-decoration:underline}\n.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55;}\n@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.28rem}.tw{font-size:.76rem}.cg{grid-template-columns:1fr}}\n<\/style>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n<header class=\"hdr\">\n<span class=\"badge hepr\">Halogen-Free \u00b7 600V\/1000V \u00b7 HEPR Rubber Insulation<\/span>\n<span class=\"badge braid\">GAALFLEX\u00ae VFD FG7(O)CR \u00b7 Copper Braid-Only Shield \u00b7 PVC R2 Inner<\/span>\n<span class=\"badge hepr\">3-Phase \u00b7 2.5\u2013300 mm\u00b2 \u00b7 8\u00d7D Bend \u00b7 EN 50265\/50266\/IEC 60332 Enhanced<\/span>\n\n<h1>GAALFLEX\u00ae VFD FG7(O)CR: 600V\/1000V European Standard Industrial Halogen-Free Variable Frequency Drive Cable with HEPR Rubber Insulation, Red Copper Braid-Only Shielding, PVC R2 Inner Sheath, Gray Special PVC Jacket, Exceptional +250\u00b0C Short-Circuit Tolerance, 3-Phase Industrial Motor, 2.5\u2013300 mm\u00b2 Flexible Class 5, 8\u00d7D Bending Radius, Enhanced EN 50266-2-4\/IEC 60332-3-24 Flame Testing | European Halogen-Free Industrial VFD Cable<\/h1>\n\n<p class=\"hdr .sub\"><span class=\"hepr-em\">European standard 600V\/1000V halogen-free VFD cable combining HEPR (halogen-free ethylene propylene rubber) insulation with simplified red copper braid-only shielding, PVC R2 inner sheath, gray special PVC outer jacket, flexible Class 5 red copper, and professional industrial motor integration<\/span>\u2014addressing halogen-free industrial frequency converter specification (non-building-code), standard temperature industrial environments (\u221215\/0 to +90\u00b0C), exceptional short-circuit fault tolerance (+250\u00b0C), simplified copper braid shielding topography, flexible motor routing (8\u00d7D bend radius), enhanced flame testing capability, and comprehensive European standard industrial automation infrastructure simultaneously.<\/p>\n\n<div class=\"meta\">\n<span>Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division<\/span>\n<span>Published May 9, 2026<\/span>\n<span>Advanced technical analysis ~150 minutes with 75+ specification tables<\/span>\n<span>European Halogen-Free Industrial VFD Cable \u00b7 HEPR Rubber \u00b7 Copper Braid Shield \u00b7 Extended Range to 300 mm\u00b2<\/span>\n<\/div>\n<\/header>\n\n<div class=\"spec-grid\">\n  <div class=\"spec-card\"><div class=\"lab\">Voltage Rating<\/div><div class=\"val\">600V\/1000V<\/div><div class=\"des\">Industrial standard<\/div><\/div>\n  <div class=\"spec-card hepr\"><div class=\"lab\">Insulation<\/div><div class=\"val\">HEPR Rubber<\/div><div class=\"des\">Halogen-free<\/div><\/div>\n  <div class=\"spec-card inner\"><div class=\"lab\">Inner Sheath<\/div><div class=\"val\">PVC R2<\/div><div class=\"des\">Electrical isolation<\/div><\/div>\n  <div class=\"spec-card braid\"><div class=\"lab\">Shielding<\/div><div class=\"val\">Cu Braid Only<\/div><div class=\"des\">No Al tape<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Conductor Range<\/div><div class=\"val\">2.5\u2013300 mm\u00b2<\/div><div class=\"des\">Extended spectrum<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Temperature<\/div><div class=\"val\">\u221215\/0 to +90\u00b0C<\/div><div class=\"des\">Standard industrial<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Configuration<\/div><div class=\"val\">3-Phase + Shield<\/div><div class=\"des\">Industrial standard<\/div><\/div>\n  <div class=\"spec-card fire\"><div class=\"lab\">Fire Rating<\/div><div class=\"val\">EN 50265\/50266\/IEC 60332<\/div><div class=\"des\">Enhanced testing<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Bending Radius<\/div><div class=\"val\">8\u00d7D Minimum<\/div><div class=\"des\">Standard flexible<\/div><\/div>\n  <div class=\"spec-card shld\"><div class=\"lab\">Short-Circuit<\/div><div class=\"val\">+250\u00b0C Max<\/div><div class=\"des\">Fault tolerance<\/div><\/div>\n<\/div>\n\n<nav class=\"toc\">\n<div class=\"toc-label\">Contents \u2014 8 Advanced Sections<\/div>\n<ol>\n<li><a href=\"#s1\">HEPR Rubber Insulation: Halogen-Free Industrial Safety (Non-Building-Code)<\/a><\/li>\n<li><a href=\"#s2\">PVC R2 Inner Sheath: Electrical Isolation &#038; Mechanical Protection<\/a><\/li>\n<li><a href=\"#s3\">Red Copper Braid-Only Shielding: Simplified EMI Suppression Architecture<\/a><\/li>\n<li><a href=\"#s4\">Extended Conductor Range: 2.5\u2013300 mm\u00b2 Maximum Industrial Spectrum<\/a><\/li>\n<li><a href=\"#s5\">Enhanced Flame Testing: EN 50265\/50266 &#038; IEC 60332-3-24 Compliance<\/a><\/li>\n<li><a href=\"#s6\">Gray Special PVC Jacket: Industrial Standard Protection &#038; Thermal Management<\/a><\/li>\n<li><a href=\"#s7\">Comparative Analysis: FG7(O)CR (Industrial Halogen-Free) vs. FG16OHH2R (Building) &#038; FE4OHH2R (XLPE)<\/a><\/li>\n<li><a href=\"#s8\">Complete GAALFLEX\u00ae VFD FG7(O)CR SKU Catalog (12+ Extended Industrial Configurations)<\/a><\/li>\n<\/ol>\n<\/nav>\n\n<section class=\"body\">\n\n<section id=\"s1\">\n<h2>1. HEPR Rubber Insulation: Halogen-Free Industrial Safety (Non-Building-Code)<\/h2>\n<p><span class=\"hepr-em\">GAALFLEX\u00ae VFD FG7(O)CR utilizes proprietary HEPR (halogen-free ethylene propylene rubber) insulation providing industrial halogen-free safety characteristics without CPR building-code requirements, enabling halogen-free performance in standard industrial frequency converter applications<\/span>.<\/p>\n<div class=\"note hepr\">\n<div class=\"nt\">HEPR Industrial vs. FG16OHH2R Building Code: Distinction<\/div>\n<p><strong>Specification strategy:<\/strong> FG7(O)CR uses HEPR insulation (halogen-free, no corrosive HCl gas) for industrial halogen-free applications without CPR building-code testing\/rating. FG16OHH2R uses identical HEPR but carries full CPR EU 305\/2011 Cca-s3,d0,a3 building certification. Result: FG7(O)CR provides halogen-free safety at industrial cost; FG16OHH2R provides building compliance premium.<\/p>\n<\/div>\n<\/section>\n\n<section id=\"s2\">\n<h2>2. PVC R2 Inner Sheath: Electrical Isolation &#038; Mechanical Protection<\/h2>\n<p><span class=\"inner-em\">GAALFLEX\u00ae VFD FG7(O)CR includes PVC R2 inner sheath providing additional electrical isolation between insulation and copper braid shield, improving mechanical durability and preventing conductor-to-shield contact<\/span>.<\/p>\n<\/section>\n\n<section id=\"s3\">\n<h2>3. Red Copper Braid-Only Shielding: Simplified EMI Suppression Architecture<\/h2>\n<p><span class=\"braid-em\">GAALFLEX\u00ae VFD FG7(O)CR features red copper braid shielding (equal section \u226416 mm\u00b2 or \u226550% phase \u226516 mm\u00b2 for >25 mm\u00b2) without aluminum tape, providing simplified shield architecture, complete conductor coverage, and cost-optimized EMI suppression<\/span>.<\/p>\n<\/section>\n\n<section id=\"s4\">\n<h2>4. Extended Conductor Range: 2.5\u2013300 mm\u00b2 Maximum Industrial Spectrum<\/h2>\n<p><span class=\"shld-em\">GAALFLEX\u00ae VFD FG7(O)CR extends to 300 mm\u00b2 maximum conductor size\u2014the largest single VFD product in the industrial series\u2014enabling complete motor spectrum from small control (2.5 mm\u00b2) through megawatt-class industrial motors (300 mm\u00b2)<\/span>.<\/p>\n<\/section>\n\n<section id=\"s5\">\n<h2>5. Enhanced Flame Testing: EN 50265\/50266 &#038; IEC 60332-3-24 Compliance<\/h2>\n<p><span class=\"fire-em\">GAALFLEX\u00ae VFD FG7(O)CR meets comprehensive flame testing per DIN VDE 0482-265-2-1, EN 50265-2-1, IEC 60332-1-2 (vertical), plus additional EN 50266-2-4 \/ IEC 60332-3-24 (tray) testing ensuring industrial fire safety<\/span>.<\/p>\n<\/section>\n\n<section id=\"s6\">\n<h2>6. Gray Special PVC Jacket: Industrial Standard Protection &#038; Thermal Management<\/h2>\n<p><span class=\"inner-em\">GAALFLEX\u00ae VFD FG7(O)CR features gray RAL 7035 special PVC compound outer sheath providing industrial standard protection and thermal dissipation characteristics matching VFD 1100 gray jacket specification<\/span>.<\/p>\n<\/section>\n\n<section id=\"s7\">\n<h2>7. Comparative Analysis: FG7(O)CR (Industrial Halogen-Free) vs. FG16OHH2R (Building) &#038; FE4OHH2R (XLPE)<\/h2>\n\n<div class=\"tw\">\n<table>\n<caption>Table 7.1-A \u2014 Performance comparison: GAALFLEX FG7(O)CR (industrial halogen-free), FG16OHH2R (building code), and FE4OHH2R (XLPE)<\/caption>\n<thead><tr><th>Metric<\/th><th>FG7(O)CR Industrial HF<\/th><th>FG16OHH2R Building Code<\/th><th>FE4OHH2R XLPE Standard<\/th><th>Winner<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">INSULATION &amp; SAFETY<\/td><\/tr>\n<tr><td>Insulation<\/td><td class=\"winner\">HEPR (halogen-free)<\/td><td class=\"winner\">HEPR (halogen-free)<\/td><td class=\"num\">XLPE (standard)<\/td><td>FG7(O)CR\/FG16<\/td><\/tr>\n<tr><td>Regulatory rating<\/td><td class=\"num\">Industrial only<\/td><td class=\"winner\">CPR Cca-s3,d0,a3<\/td><td class=\"num\">Industrial only<\/td><td>FG16OHH2R<\/td><\/tr>\n<tr><td>Halogen-free cost<\/td><td class=\"winner\">Industrial tier<\/td><td class=\"num\">Building premium<\/td><td class=\"num\">Not applicable<\/td><td>FG7(O)CR<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">SHIELDING &amp; ARCHITECTURE<\/td><\/tr>\n<tr><td>Shield type<\/td><td class=\"winner\">Cu braid only<\/td><td class=\"num\">Al tape + Cu braid<\/td><td class=\"num\">Al tape + Cu braid<\/td><td>FG7(O)CR<\/td><\/tr>\n<tr><td>Inner sheath<\/td><td class=\"winner\">PVC R2 (yes)<\/td><td class=\"num\">No inner sheath<\/td><td class=\"num\">No inner sheath<\/td><td>FG7(O)CR<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">CONDUCTOR &amp; PERFORMANCE<\/td><\/tr>\n<tr><td>Max conductor<\/td><td class=\"winner\">300 mm\u00b2 (largest)<\/td><td class=\"num\">240 mm\u00b2<\/td><td class=\"num\">240 mm\u00b2<\/td><td>FG7(O)CR<\/td><\/tr>\n<tr><td>Temperature range<\/td><td class=\"num\">\u221215\/0 to +90\u00b0C<\/td><td class=\"num\">\u221215 to +90\u00b0C<\/td><td class=\"num\">\u221220 to +90\u00b0C<\/td><td>FE4OHH2R<\/td><\/tr>\n<tr><td>Short-circuit<\/td><td class=\"winner\">+250\u00b0C<\/td><td class=\"winner\">+250\u00b0C<\/td><td class=\"winner\">+250\u00b0C<\/td><td>All equal<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"note braid\">\n<div class=\"nt\">FG7(O)CR Positioning: Industrial Halogen-Free Extended Range<\/div>\n<p><strong>Choice strategy:<\/strong> FG7(O)CR (HEPR, Cu braid, PVC R2 inner, 2.5\u2013300 mm\u00b2) = halogen-free industrial cable with largest conductor spectrum and simplified braid-only shielding. FG16OHH2R (HEPR, building code) = CPR mandatory building installations. FE4OHH2R (XLPE, 2\/3\/4-core) = cost-optimized. Choose FG7(O)CR for halogen-free industrial with extended motor spectrum; choose FG16OHH2R for building compliance.<\/p>\n<\/div>\n\n<\/section>\n\n<section id=\"s8\">\n<h2>8. Complete GAALFLEX\u00ae VFD FG7(O)CR SKU Catalog (12+ Extended Industrial Configurations)<\/h2>\n\n<p>GAALFLEX\u00ae VFD FG7(O)CR halogen-free industrial VFD cables span comprehensive 2.5\u2013300 mm\u00b2 conductor range with 3-phase + shield configuration optimized for halogen-free industrial frequency converter systems including extended motor range.<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 8.1-B \u2014 GAALFLEX\u00ae VFD FG7(O)CR 600V\/1000V (HEPR halogen-free, PVC R2 inner, Cu braid shield, gray PVC jacket): Selected SKU portfolio (12+ total configurations) \u2014 3-Phase + Shield Extended Industrial Version<\/caption>\n<thead><tr><th>Configuration<\/th><th>Size (mm\u00b2)<\/th><th>O.\u00d8 (mm)<\/th><th>Cu Weight (kg\/km)<\/th><th>Cable Weight (kg\/km)<\/th><th>Industrial Application<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">SMALL POWER (2.5\u201310 mm\u00b2) \u2014 Halogen-Free Control &#038; Small Motor<\/td><\/tr>\n<tr><td>3 x 2.5 + SH<\/td><td class=\"num\">2.5 mm\u00b2<\/td><td class=\"num\">14.6<\/td><td class=\"num\">96<\/td><td class=\"num\">340<\/td><td>Halogen-free 5 kW<\/td><\/tr>\n<tr><td>3 x 6 + SH<\/td><td class=\"num\">6 mm\u00b2<\/td><td class=\"num\">18.7<\/td><td class=\"num\">231<\/td><td class=\"num\">490<\/td><td>Halogen-free 15 kW<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">MEDIUM POWER (16\u201350 mm\u00b2) \u2014 Halogen-Free Industrial Standard<\/td><\/tr>\n<tr><td>3 x 25 + SH<\/td><td class=\"num\">25 mm\u00b2<\/td><td class=\"num\">28.8<\/td><td class=\"num\">873<\/td><td class=\"num\">1410<\/td><td>Halogen-free 60 kW<\/td><\/tr>\n<tr><td>3 x 50 + SH<\/td><td class=\"num\">50 mm\u00b2<\/td><td class=\"num\">36<\/td><td class=\"num\">1680<\/td><td class=\"num\">2400<\/td><td>Halogen-free 100 kW<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">HIGH POWER (70\u2013150 mm\u00b2) \u2014 Extended Halogen-Free Industrial<\/td><\/tr>\n<tr><td>3 x 95 + SH<\/td><td class=\"num\">95 mm\u00b2<\/td><td class=\"num\">47.6<\/td><td class=\"num\">3192<\/td><td class=\"num\">4350<\/td><td>Halogen-free 150 kW<\/td><\/tr>\n<tr><td>3 x 150 + SH<\/td><td class=\"num\">150 mm\u00b2<\/td><td class=\"num\">56.4<\/td><td class=\"num\">5040<\/td><td class=\"num\">6880<\/td><td>Halogen-free 200+ kW<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">MAXIMUM POWER (185\u2013300 mm\u00b2) \u2014 Extended Spectrum Only<\/td><\/tr>\n<tr><td>3 x 185 + SH<\/td><td class=\"num\">185 mm\u00b2<\/td><td class=\"num\">64.8<\/td><td class=\"num\">6216<\/td><td class=\"num\">8350<\/td><td>Halogen-free 250 kW<\/td><\/tr>\n<tr><td>3 x 240 + SH<\/td><td class=\"num\">240 mm\u00b2<\/td><td class=\"num\">74.5<\/td><td class=\"num\">8604<\/td><td class=\"num\">11540<\/td><td>Halogen-free 400 kW<\/td><\/tr>\n<tr><td>3 x 300 + SH<\/td><td class=\"num\">300 mm\u00b2<\/td><td class=\"num\">85.5<\/td><td class=\"num\">10080<\/td><td class=\"num\">13480<\/td><td>Halogen-free 500+ kW<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">All GAALFLEX\u00ae VFD FG7(O)CR SKUs (3-phase + shield halogen-free extended): 600V\/1000V (0.6\/1 kV), proprietary HEPR halogen-free rubber insulation, flexible Class 5 red copper (IEC 60228, DIN VDE 0295), PVC R2 inner sheath, red copper braid (equal to phase \u226416 mm\u00b2 or \u226550% phase \u226516 mm\u00b2 for >25 mm\u00b2 \u2014 NO aluminum tape), gray RAL 7035 special PVC compound outer sheath, 3-phase brown\/black\/gray + shield per DIN VDE 0293-308, 2.5\u2013300 mm\u00b2 extended maximum spectrum, 8\u00d7D minimum bending radius, temperature \u221215\/0 to +90\u00b0C standard industrial, +250\u00b0C maximum short-circuit, 4 kV test voltage per DIN VDE, DIN VDE 0482-265-2-1 \/ EN 50265-2-1 \/ IEC 60332-1-2 (vertical) + EN 50266-2-4 \/ IEC 60332-3-24 (tray) enhanced flame testing, halogen-free industrial application (not building-code rated), suitable per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, RoHS &#038; CE certified. Optimized for halogen-free industrial frequency converter systems (2.5\u2013300 mm\u00b2 complete motor spectrum including megawatt-class), HEPR halogen-free insulation eliminating HCl gas, simplified copper braid-only shielding architecture, PVC R2 inner sheath protection, gray RAL 7035 thermal dissipation, exceptional short-circuit survivability (+250\u00b0C), flexible 8\u00d7D installation, European standard industrial specification, and comprehensive halogen-free industrial VFD automation infrastructure with proprietary HEPR insulation, PVC R2 electrical isolation, simplified Cu braid architecture, extended 2.5\u2013300 mm\u00b2 motor range, and professional standard industrial frequency converter system integration for halogen-free industrial motor applications from small control to megawatt-class motors.<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/section>\n\n<\/section>\n\n<section class=\"refs\">\n<h2>Technical References<\/h2>\n<ol class=\"rl\">\n<li>IEC. (2023). <em>IEC 60228: Conductors of Insulated Cables\u2014Flexible Class 5 Copper<\/em>.<\/li>\n<li>DIN VDE. (2023). <em>DIN VDE 0482-265-2-1: Vertical Flame Propagation Test<\/em>.<\/li>\n<li>European Committee. (2023). <em>EN 50265-2-1: Fire Test for Non-Metallic Materials<\/em>.<\/li>\n<li>DIN VDE. (2023). <em>DIN VDE 0482-266-2-4: Horizontal Tray Flame Test<\/em>.<\/li>\n<li>European Committee. (2023). <em>EN 50266-2-4: Tray Flame Test for Power Cables<\/em>.<\/li>\n<li>IEC. (2023). <em>IEC 60332-3-24: Vertical Tray Flame Test Category C<\/em>.<\/li>\n<li>Feichun Cable Engineering. (2023). <em>HEPR Rubber: Halogen-Free Insulation for Industrial VFD<\/em>.<\/li>\n<li>Industrial Standard. (2023). <em>PVC R2 Inner Sheath: Electrical Isolation &#038; Mechanical Protection<\/em>.<\/li>\n<\/ol>\n<\/section>\n\n<section class=\"contact\">\n<h3>European Halogen-Free Industrial VFD Cable Solutions<\/h3>\n<p style=\"margin-bottom:1rem;color:var(--c-secondary);font-size:.88rem\">For 600V\/1000V European halogen-free industrial frequency converter cable solutions with HEPR insulation, copper braid-only shielding, PVC R2 inner sheath, and extended 2.5\u2013300 mm\u00b2 spectrum: <a href=\"mailto:Tech@feichuncables.com\" style=\"color:var(--c-link);text-decoration:none\">Tech@feichuncables.com<\/a> | Industrial Drive Solutions Division | Anhui Feichun Special Cable Co., Ltd.<\/p>\n<div class=\"cg\">\n<div class=\"ci\"><span class=\"lb\">Halogen-Free HEPR Insulation<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Extended 2.5\u2013300 mm\u00b2 Range<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Copper Braid-Only Shield<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Industrial Drive Solutions Division<\/span>Anhui Feichun Special Cable Co., Ltd.<\/div>\n<\/div>\n<\/section>\n\n<footer class=\"ft\">\n<p><strong>GAALFLEX\u00ae VFD FG7(O)CR: 600V\/1000V European Standard Halogen-Free Industrial VFD Cable with HEPR Rubber &#038; Copper Braid-Only Shield<\/strong> \u2014 600V\/1000V halogen-free industrial VFD cable, HEPR rubber halogen-free insulation, gray RAL 7035 special PVC jacket, PVC R2 inner sheath, red copper braid-only shielding (no aluminum tape), exceptional +250\u00b0C short-circuit, flexible Class 5 red copper per IEC 60228, 3-phase brown\/black\/gray + shield per DIN VDE 0293-308, 2.5\u2013300 mm\u00b2 extended maximum spectrum, 8\u00d7D minimum bending radius, temperature \u221215\/0 to +90\u00b0C standard industrial, 4 kV test voltage, DIN VDE 0482-265-2-1 \/ EN 50265-2-1 \/ IEC 60332-1-2 (vertical) + EN 50266-2-4 \/ IEC 60332-3-24 (tray) enhanced flame testing, halogen-free industrial (non-building-code), suitable per EN 55011\/DIN VDE 0875\/EN 61800-3, RoHS &#038; CE certified. Comprehensive portfolio (12+ extended SKUs) for halogen-free industrial motor VFD systems.<\/p>\n<p style=\"margin-top:.6rem\">European halogen-free industrial VFD cable for frequency converter systems: 600V\/1000V dual-voltage European industrial specification, HEPR halogen-free insulation eliminating toxic HCl gas in halogen-free environments, PVC R2 inner sheath providing electrical isolation and mechanical protection, simplified red copper braid-only shielding architecture (no aluminum tape), gray RAL 7035 thermal dissipation, extended 2.5\u2013300 mm\u00b2 conductor spectrum enabling megawatt-class motor applications, exceptional +250\u00b0C short-circuit survivability, flexible 8\u00d7D installation, standard temperature range (\u221215 to +90\u00b0C), enhanced flame testing (EN 50265\/50266 + IEC 60332-3-24), and comprehensive halogen-free industrial VFD automation infrastructure with proprietary HEPR halogen-free insulation, PVC R2 electrical isolation, simplified Cu braid shielding, extended conductor range, and professional industrial frequency converter system integration for complete halogen-free motor spectrum.<\/p>\n<\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"GAALFLEX\u00ae VFD FG7(O)CR: 600V\/1000V European Standard Industrial Halogen-Free Variable Frequency Drive Cable with HEPR Rubber Insulation, Red Copper Braid-Only Shielding, PVC R2 Inner Sheath, Gray Special PVC Jacket, Exceptional +250\u00b0C Short-Circuit Tolerance, 3-Phase Industrial Motor, 2.5\u2013300 mm\u00b2 Flexible Class 5, 8\u00d7D Bending Radius, Enhanced EN 50266-2-4\/IEC 60332-3-24 Flame Testing | European Halogen-Free Industrial VFD Cable\nEuropean standard 600V\/1000V halogen-free VFD cable combining HEPR (halogen-free ethylene propylene rubber) insulation with simplified red copper braid-only shielding, PVC R2 inner sheath, gray special PVC outer jacket, flexible Class 5 red copper, and professional industrial motor integration\u2014addressing halogen-free industrial frequency converter specification (non-building-code), standard temperature industrial environments (\u221215\/0 to +90\u00b0C), exceptional short-circuit fault tolerance (+250\u00b0C), simplified copper braid shielding topography, flexible motor routing (8\u00d7D bend radius), enhanced flame testing capability, and comprehensive European standard industrial automation infrastructure simultaneously.","protected":false},"author":1,"featured_media":11758,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,165,35],"tags":[57856,57905,57858,57855,505,57707,57512,57871,57860,57862,57595,55139,57594,57859,51947,57603,57865,57540,35521,57626,57242,57868,56776,56994,57867,12254,18392,57611,57872,56278,57863,18233,57604,7034,57864,57816,4491,57654,57851,411,414,57866,57598,57854,57465,4513,57015,57933,57861,56856,7048,18237,57492,2025],"class_list":["post-11756","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-drag-chain-cable","category-festoon-cable","tag-250--km-transfer-impedance-30-mhz","tag-90c-2","tag-5c-flexible","tag-50c-fixed","tag-0-6-1-kv","tag-1-5-240-mm","tag-1000v","tag-1000v-80c-vw-1","tag-20xd-multiple-bending","tag-200-mkm-insulation-resistance","tag-33-earth-conductor","tag-4-kv-test-voltage","tag-4-core-2","tag-4xd-single-bending","tag-600v","tag-70-410-nf-km","tag-acid-resistant","tag-aluminum-tape","tag-arctic-mining","tag-awm-style-2570","tag-black-ral-9005","tag-caustic-resistant","tag-ce-certified","tag-class-5-flexible-red-copper","tag-csa-ft-1","tag-din-vde-0295","tag-din-vde-0482-265-2-1","tag-din-vde-0875","tag-dry-damp-wet-rooms","tag-dual-layer-shielding","tag-emc-optimization","tag-en-50265-2-1","tag-en-55011","tag-en-61800-3","tag-european-standard","tag-extreme-cold","tag-feichun-cable","tag-frequency-converter","tag-gaalflex-vfd-9yslcyk-j","tag-iec-60228","tag-iec-60332-1-2","tag-industrial-motor","tag-low-mutual-capacitance","tag-low-coupling-emc","tag-nfpa-79","tag-oil-resistant","tag-petp-foil","tag-pp-polypropylene","tag-pvc-halogen-free-sheath","tag-rohs","tag-tinned-copper-braid","tag-ul-vw-1","tag-uv-resistant-2","tag-variable-frequency-drive","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11756","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=11756"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11756\/revisions"}],"predecessor-version":[{"id":11759,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11756\/revisions\/11759"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/11758"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=11756"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=11756"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=11756"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}