{"id":11739,"date":"2026-05-11T10:09:40","date_gmt":"2026-05-11T02:09:40","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=11739"},"modified":"2026-05-11T10:09:42","modified_gmt":"2026-05-11T02:09:42","slug":"gaalflex-vfd-1000-p","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/gaalflex-vfd-1000-p\/","title":{"rendered":"GAALFLEX\u00ae VFD 1000 P"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Inverter, connection to frequency converters, UV Resistant, 0,6\/1 kV<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"efeeed\" data-has-transparency=\"false\" style=\"--dominant-color: #efeeed;\" loading=\"lazy\" decoding=\"async\" width=\"710\" height=\"628\" sizes=\"auto, (max-width: 710px) 100vw, 710px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400-710x628.avif\" alt=\"\" class=\"wp-image-11740 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400-710x628.avif 710w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400-300x265.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400-768x679.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400-400x354.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400-800x707.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400-832x736.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1400.avif 854w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>GAALFLEX\u00ae VFD 1000 P: 600V\/1000V European Standard Variable Frequency Drive Cable with GAALTHERM\u00ae 530 Proprietary Insulation, Extreme +250\u00b0C Short-Circuit Tolerance, UV-Resistant PUR Jacket, Aluminum Tape + Red Copper Braid Shielding, 3-Phase Industrial Motor, 2.5\u2013300 mm\u00b2 Flexible Class 5, 8\u00d7D Bending Radius, Industrial Frequency Converter Integration | European Extreme-Performance VFD Cable<\/title>\n<meta name=\"description\" content=\"GAALFLEX\u00ae VFD 1000 P: European standard 600V\/1000V (0.6\/1 kV) variable frequency drive cable engineered for extreme-performance frequency converter systems, industrial motor power distribution, and hazardous high-temperature environments featuring proprietary GAALTHERM\u00ae 530 thermoplastic insulation with exceptional electrical stability and flame-retardant characteristics, 600V\/1000V dual nominal voltage enabling European DIN VDE and international IEC specification, 3-phase + shield conductor configuration supporting comprehensive industrial motor VFD systems, mm\u00b2 conductor range (2.5\u2013300 mm\u00b2) with flexible Class 5 red copper per IEC 60228 \/ DIN VDE 0295 enabling complete industrial motor specification from control circuits (2.5 mm\u00b2) through maximum industrial motor systems (300 mm\u00b2), aluminum tape 100% covering + red copper braid shielding (same section as phase \u226416 mm\u00b2 or \u226550% phase section minimum 16 mm\u00b2 for >25 mm\u00b2) providing comprehensive EMI suppression and exceptional grounding continuity, black RAL 9005 special PUR (polyurethane) compound outer sheath with UV resistance enabling outdoor industrial installation, extreme temperature capability with \u221250\u00b0C fixed\/\u221240\u00b0C flexible minimum through +90\u00b0C maximum conductor operating temperature and exceptional +250\u00b0C maximum short-circuit temperature enabling extreme-fault-condition tolerance critical for industrial motor VFD systems, 8\u00d7D minimum bending radius supporting flexible installation with minimal cable damage during routing and handling, 4 kV test voltage per DIN VDE standard, comprehensive flame testing per DIN VDE 0482-265-2-1, EN 50265-2-1, IEC 60332-1-2 ensuring fire safety, UV resistance per IEC 60502-1 \/ CEI 20-13 \/ CEI-UNEL 35375 enabling outdoor sun-exposed installations, EMC compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, optional GAALFLEX\u00ae VFD 1000 PH halogen-free version with proprietary GAALTHERM\u00ae 630 thermoplastic insulation upgrade available on request, RoHS and CE approved, and complete European extreme-performance industrial VFD infrastructure compliance enabling OEM frequency converter integration, industrial motor power distribution, extreme-temperature fault conditions, and professional high-performance variable-frequency motor drive system acceptance with exceptional short-circuit tolerance and extreme-condition capability.&#8221; \/>\n<meta name=\"keywords\" content=\"VFD cable,600V,1000V,GAALTHERM,short-circuit,extreme temperature,PUR,European standard,IEC 60502,frequency converter,industrial motor\" \/>\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<meta name=\"robots\" content=\"index,follow,max-image-preview:large,max-snippet:-1\" \/>\n<meta property=\"og:title\" content=\"GAALFLEX\u00ae VFD 1000 P: GAALTHERM\u00ae 530 Extreme-Performance VFD Cable\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta name=\"article:published_time\" content=\"2026-05-09T00:00:00Z\" \/>\n<meta name=\"article:author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.feichuncables.com\/industrial-motors\/gaalflex-vfd-1000-p-gaaltherm530-extreme-performance\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin \/>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\" \/>\n<style>\n:root{\n  --bg-body:#F7F5F1; --bg-surface:#FFFFFF; --bg-recessed:#F0E8E0; --bg-th:#5A4A4A; --bg-tr-alt:#F9F8F5;\n  --bg-callout-gaal:#E8D0D8; --bg-callout-sc:#D8D8F5; --bg-callout-pur:#D0E8F5; --bg-callout-perf:#E8E0D0;\n  --bg-callout-fire:#E8F0E0;\n  --c-body:#1B1F1D; --c-secondary:#454D4A; --c-tertiary:#727A76; --c-inverse:#FFFFFF;\n  --c-link:#2A5A8A; --c-gaal:#8A2A4A; --c-sc:#4A2A8A; --c-pur:#2A5A8A;\n  --c-perf:#8A6A2A; --c-fire:#6A8A2A;\n  --b-rule:#D4D0C8; --b-light:#E8E5DE; --b-accent:#2A5A8A; --b-table:#C4C0BA;\n  --sh-sm:0 1px 2px rgba(0,0,0,0.06); --sh-md:0 3px 12px rgba(0,0,0,0.08);\n  --badge-bg:#5A4A4A; --badge-c:#FFFFFF; --badge-gaal:#8A2A4A; --badge-sc:#4A2A8A;\n}\n@media(prefers-color-scheme:dark){\n  :root{\n    --bg-body:#0B0F0D; --bg-surface:#161A18; --bg-recessed:#0F1A10; --bg-th:#5A4A4A; --bg-tr-alt:#0F1211;\n    --bg-callout-gaal:#2A0A0A; --bg-callout-sc:#0A0A50; --bg-callout-pur:#0A1A40; --bg-callout-perf:#2A1A0A;\n    --bg-callout-fire:#0A2A10;\n    --c-body:#E2E5E2; --c-secondary:#B3BAB6; --c-tertiary:#858D8A; --c-inverse:#0B0F0D;\n    --c-link:#6A98C8; --c-gaal:#E88080; --c-sc:#A880E8; --c-pur:#6A88E8;\n    --c-perf:#E8B880; --c-fire:#B8D880;\n    --b-rule:#252D2A; --b-light:#1D2421; --b-accent:#6A98C8; --b-table:#232B28;\n  }\n}\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nhtml{font-size:16px;scroll-behavior:smooth}\nbody{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden;}\n.page-wrap{max-width:920px;margin:0 auto;padding:2.5rem 1.25rem 4rem}\n.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--c-link);position:relative;}\n.hdr::after{content:\"\";position:absolute;left:0;bottom:-2px;width:400px;height:2px;background:linear-gradient(90deg,#8A2A4A 0%,#4A2A8A 50%,#8A6A2A 100%);}\n.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem;}\n.hdr .badge.gaal{background:var(--badge-gaal)} .hdr .badge.sc{background:var(--badge-sc)}\n.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.4rem,3.3vw,2.05rem);line-height:1.24;margin-bottom:.7rem;letter-spacing:-.005em;color:var(--c-link);}\n.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.65;margin-bottom:.4rem;}\n.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary);}\n.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm);}\n.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-link);margin-bottom:.55rem;}\n.toc ol{list-style:none;counter-reset:tc;padding:0;columns:2;column-gap:1.5rem}\n.toc li{counter-increment:tc;margin-bottom:.28rem;break-inside:avoid}\n.toc li::before{content:counter(tc,decimal-leading-zero) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-perf);}\n.toc a{font-size:.82rem;color:var(--c-secondary);text-decoration:none;line-height:1.4;}\n.toc a:hover{color:var(--c-link);text-decoration:underline}\n@media(max-width:640px){.toc ol{columns:1}}\n.body h2{font-family:'Source Serif 4',Georgia,serif;font-weight:700;font-size:1.38rem;margin:3rem 0 .9rem;padding-bottom:.4rem;border-bottom:1px solid var(--b-light);color:var(--c-link);line-height:1.3;}\n.body h3{font-weight:600;font-size:1.06rem;margin:1.9rem 0 .55rem;color:var(--c-body);}\n.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify;hyphens:auto;}\n.body strong{font-weight:600;color:var(--c-body)}\n.gaal-em{color:var(--c-gaal);font-weight:600} .sc-em{color:var(--c-sc);font-weight:600} .pur-em{color:var(--c-pur);font-weight:600}\n.perf-em{color:var(--c-perf);font-weight:600} .fire-em{color:var(--c-fire);font-weight:600}\n.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-sm);}\n.tw table{width:100%;border-collapse:collapse;font-size:.83rem;line-height:1.45;min-width:720px;}\n.tw caption{text-align:left;font-weight:600;font-size:.76rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light);}\n.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.72rem;padding:.55rem .7rem;text-align:left;border-bottom:2px solid var(--c-link);}\n.tw tbody td{padding:.5rem .7rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top;}\n.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)} .tw tbody tr:hover{background:var(--bg-callout-sc)}\n.tw tbody td:first-child{font-weight:500;color:var(--c-body)}\n.tw tbody td code{font-family:'IBM Plex Mono',monospace;font-size:.78rem;background:var(--bg-recessed);padding:.08em .35em;border-radius:3px;}\n.tw tbody td.num{font-family:'IBM Plex Mono',monospace;font-size:.79rem;text-align:right;}\n.tw tbody td.winner{background:var(--bg-callout-fire);color:var(--c-body);font-weight:600;}\n.note{padding:1rem 1.25rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent);}\n.note.gaal{background:var(--bg-callout-gaal);border-left-color:var(--c-gaal)}\n.note.sc{background:var(--bg-callout-sc);border-left-color:var(--c-sc)}\n.note.pur{background:var(--bg-callout-pur);border-left-color:var(--c-pur)}\n.note.perf{background:var(--bg-callout-perf);border-left-color:var(--c-perf)}\n.note.fire{background:var(--bg-callout-fire);border-left-color:var(--c-fire)}\n.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.35rem;}\n.note p{margin-bottom:.35rem}\n.spec-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(190px,1fr));gap:1rem;margin:1.5rem 0;}\n.spec-card{background:var(--bg-surface);border:1px solid var(--b-rule);border-top:3px solid var(--c-link);border-radius:4px;padding:1rem 1.1rem;}\n.spec-card.gaal{border-top-color:var(--c-gaal)}\n.spec-card.sc{border-top-color:var(--c-sc)}\n.spec-card.pur{border-top-color:var(--c-pur)}\n.spec-card.perf{border-top-color:var(--c-perf)}\n.spec-card.fire{border-top-color:var(--c-fire)}\n.spec-card .lab{font-size:.68rem;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.4rem;}\n.spec-card .val{font-family:'IBM Plex Mono',monospace;font-size:1.08rem;font-weight:600;color:var(--c-body);line-height:1.3;margin-bottom:.3rem;}\n.spec-card .des{font-size:.78rem;color:var(--c-secondary);line-height:1.45;}\n.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--c-link);}\n.refs h2{font-size:1.08rem;margin-bottom:.9rem}\n.rl{list-style:none;counter-reset:rf;padding:0}\n.rl li{counter-increment:rf;font-size:.79rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5;}\n.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.74rem;}\n.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.5rem;margin-top:2.5rem;}\n.contact h3{font-size:.98rem;margin-bottom:.7rem}\n.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem;}\n.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}\n.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem;}\n.ci a{color:var(--c-link);text-decoration:none} .ci a:hover{text-decoration:underline}\n.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55;}\n@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.28rem}.tw{font-size:.76rem}.cg{grid-template-columns:1fr}}\n<\/style>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n<header class=\"hdr\">\n<span class=\"badge gaal\">GAALTHERM\u00ae 530 Insulation \u00b7 600V\/1000V \u00b7 Extreme Performance<\/span>\n<span class=\"badge sc\">GAALFLEX\u00ae VFD 1000 P \u00b7 +250\u00b0C Short-Circuit \u00b7 PUR UV-Resistant<\/span>\n<span class=\"badge gaal\">3-Phase \u00b7 2.5\u2013300 mm\u00b2 \u00b7 8\u00d7D Bend \u00b7 Optional PH Halogen-Free<\/span>\n\n<h1>GAALFLEX\u00ae VFD 1000 P: 600V\/1000V European Standard Variable Frequency Drive Cable with Proprietary GAALTHERM\u00ae 530 Insulation, Extreme +250\u00b0C Short-Circuit Tolerance, UV-Resistant PUR Jacket, Aluminum Tape + Red Copper Braid Shielding, 3-Phase Industrial Motor, 2.5\u2013300 mm\u00b2 Flexible Class 5, 8\u00d7D Minimum Bending Radius, \u221250\/\u221240 to +90\u00b0C Temperature Range, Industrial Frequency Converter Integration, Optional GAALFLEX\u00ae VFD 1000 PH Halogen-Free (GAALTHERM\u00ae 630 Upgrade) | European Extreme-Performance Industrial VFD Cable<\/h1>\n\n<p class=\"hdr .sub\"><span class=\"gaal-em\">UL-certified European standard 600V\/1000V extreme-performance VFD cable combining proprietary GAALTHERM\u00ae 530 insulation with exceptional electrical stability and exceptional +250\u00b0C short-circuit tolerance, flexible Class 5 red copper, aluminum tape + red copper braid shielding, UV-resistant PUR outer jacket, and professional extreme-condition industrial motor integration<\/span>\u2014addressing extreme-performance frequency converter specification (600V\/1000V), industrial motor control, exceptional short-circuit fault conditions (+250\u00b0C maximum), outdoor UV-resistant installation, flexible motor routing (8\u00d7D bend radius), hazardous-environment capability, and comprehensive European extreme-performance industrial automation infrastructure simultaneously.<\/p>\n\n<div class=\"meta\">\n<span>Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division<\/span>\n<span>Published May 9, 2026<\/span>\n<span>Advanced technical analysis ~160 minutes with 85+ specification tables<\/span>\n<span>European Extreme-Performance VFD Cable \u00b7 GAALTHERM\u00ae 530 \u00b7 +250\u00b0C Short-Circuit \u00b7 8\u00d7D Flexible<\/span>\n<\/div>\n<\/header>\n\n<div class=\"spec-grid\">\n  <div class=\"spec-card\"><div class=\"lab\">Voltage Rating<\/div><div class=\"val\">600V\/1000V<\/div><div class=\"des\">European 0.6\/1 kV<\/div><\/div>\n  <div class=\"spec-card gaal\"><div class=\"lab\">Insulation<\/div><div class=\"val\">GAALTHERM\u00ae 530<\/div><div class=\"des\">Proprietary thermoplastic<\/div><\/div>\n  <div class=\"spec-card sc\"><div class=\"lab\">Short-Circuit Temp<\/div><div class=\"val\">+250\u00b0C Max<\/div><div class=\"des\">Extreme fault tolerance<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Conductor Range<\/div><div class=\"val\">2.5\u2013300 mm\u00b2<\/div><div class=\"des\">Comprehensive spectrum<\/div><\/div>\n  <div class=\"spec-card pur\"><div class=\"lab\">Outer Jacket<\/div><div class=\"val\">PUR UV-Resistant<\/div><div class=\"des\">Outdoor capable<\/div><\/div>\n  <div class=\"spec-card perf\"><div class=\"lab\">Bending Radius<\/div><div class=\"val\">8\u00d7D Minimum<\/div><div class=\"des\">Most flexible available<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Configuration<\/div><div class=\"val\">3-Phase + Shield<\/div><div class=\"des\">Industrial motor standard<\/div><\/div>\n  <div class=\"spec-card fire\"><div class=\"lab\">Fire Rating<\/div><div class=\"val\">DIN VDE\/IEC\/EN<\/div><div class=\"des\">Self-extinguishing<\/div><\/div>\n  <div class=\"spec-card gaal\"><div class=\"lab\">Optional Version<\/div><div class=\"val\">VFD 1000 PH<\/div><div class=\"des\">GAALTHERM\u00ae 630 halogen-free<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Temperature Range<\/div><div class=\"val\">\u221250\/\u221240 to +90\u00b0C<\/div><div class=\"des\">Extreme arctic to tropical<\/div><\/div>\n<\/div>\n\n<nav class=\"toc\">\n<div class=\"toc-label\">Contents \u2014 10 Advanced Sections<\/div>\n<ol>\n<li><a href=\"#s1\">GAALTHERM\u00ae 530 Proprietary Insulation: Electrical Stability &#038; Flame-Retardant Design<\/a><\/li>\n<li><a href=\"#s2\">Extreme +250\u00b0C Short-Circuit Tolerance: Fault Condition Survivability<\/a><\/li>\n<li><a href=\"#s3\">PUR UV-Resistant Outer Jacket: Outdoor Industrial Installation<\/a><\/li>\n<li><a href=\"#s4\">Aluminum Tape + Red Copper Braid Shielding: Comprehensive EMI Protection<\/a><\/li>\n<li><a href=\"#s5\">8\u00d7D Minimum Bending Radius: Flexible Industrial Routing<\/a><\/li>\n<li><a href=\"#s6\">3-Phase + Shield Configuration: Industrial Motor Standard<\/a><\/li>\n<li><a href=\"#s7\">2.5\u2013300 mm\u00b2 Comprehensive Range: Control to Maximum Motor Power<\/a><\/li>\n<li><a href=\"#s8\">\u221250\/\u221240 to +90\u00b0C Extreme Temperature: Arctic to Tropical Operation<\/a><\/li>\n<li><a href=\"#s9\">Comparative Analysis: VFD 1000 P (GAALTHERM\u00ae 530) vs. 1100 PH (GAALTHERM\u00ae 630) &#038; Standard VFD Cables<\/a><\/li>\n<li><a href=\"#s10\">Complete GAALFLEX\u00ae VFD 1000 P SKU Catalog (12+ Extreme-Performance Configurations)<\/a><\/li>\n<\/ol>\n<\/nav>\n\n<section class=\"body\">\n\n<section id=\"s1\">\n<h2>1. GAALTHERM\u00ae 530 Proprietary Insulation: Electrical Stability &#038; Flame-Retardant Design<\/h2>\n<p><span class=\"gaal-em\">GAALFLEX\u00ae VFD 1000 P utilizes proprietary GAALTHERM\u00ae 530 thermoplastic insulation providing exceptional electrical stability, flame-retardant performance, and thermal characteristic optimization critical for extreme-performance frequency converter systems<\/span>.<\/p>\n<div class=\"note gaal\">\n<div class=\"nt\">GAALTHERM\u00ae Proprietary Materials: FeiChun Technical Leadership<\/div>\n<p><strong>Material science strategy:<\/strong> GAALTHERM\u00ae represents FeiChun&#8217;s proprietary thermoplastic compound family optimized for specific high-voltage applications. GAALTHERM\u00ae 530 (VFD 1000 P) provides balanced electrical\/thermal\/mechanical performance. GAALTHERM\u00ae 630 (VFD 1000 PH, VFD 1100 PH, VFD 1405 2000V) provides premium halogen-free CPR building compliance. Result: FeiChun independent material innovation, not dependence on standard PE\/XLPE\/PUR formulations.<\/p>\n<\/div>\n<\/section>\n\n<section id=\"s2\">\n<h2>2. Extreme +250\u00b0C Short-Circuit Tolerance: Fault Condition Survivability<\/h2>\n<p><span class=\"sc-em\">GAALFLEX\u00ae VFD 1000 P provides exceptional +250\u00b0C maximum short-circuit temperature enabling survival of extreme fault conditions, motor stall events, and frequency converter protection system testing without insulation degradation or cable failure<\/span>.<\/p>\n<div class=\"note sc\">\n<div class=\"nt\">Short-Circuit Survivability: Fault Tolerance Engineering<\/div>\n<p><strong>Industrial motor protection scenario:<\/strong> Industrial frequency converter systems experience transient short-circuit events during motor stall (locked rotor), phase-to-ground faults, and protection system testing. Standard cables (typically +180\u2013200\u00b0C) can experience insulation softening or charring. GAALFLEX VFD 1000 P +250\u00b0C rating ensures complete short-circuit event survival with zero insulation damage. Result: improved motor protection system reliability, reduced nuisance cable failures, extended cable life in fault-prone industrial environments.<\/p>\n<\/div>\n<\/section>\n\n<section id=\"s3\">\n<h2>3. PUR UV-Resistant Outer Jacket: Outdoor Industrial Installation<\/h2>\n<p><span class=\"pur-em\">GAALFLEX\u00ae VFD 1000 P features UV-resistant PUR (polyurethane) compound outer sheath enabling outdoor industrial installation without sunlight-induced degradation, per IEC 60502-1 \/ CEI 20-13 \/ CEI-UNEL 35375 standards<\/span>.<\/p>\n<\/section>\n\n<section id=\"s4\">\n<h2>4. Aluminum Tape + Red Copper Braid Shielding: Comprehensive EMI Protection<\/h2>\n<p><span class=\"perf-em\">GAALFLEX\u00ae VFD 1000 P features aluminum tape 100% covering with red copper braid (equal section \u226416 mm\u00b2 or \u226550% phase \u226516 mm\u00b2 for >25 mm\u00b2) providing comprehensive frequency converter EMI suppression and grounding continuity<\/span>.<\/p>\n<\/section>\n\n<section id=\"s5\">\n<h2>5. 8\u00d7D Minimum Bending Radius: Flexible Industrial Routing<\/h2>\n<p><span class=\"perf-em\">GAALFLEX\u00ae VFD 1000 P provides 8\u00d7D minimum bending radius enabling flexible installation through motor junction boxes, equipment cabinets, and conduit systems without insulation cracking or copper fatigue<\/span>.<\/p>\n<\/section>\n\n<section id=\"s6\">\n<h2>6. 3-Phase + Shield Configuration: Industrial Motor Standard<\/h2>\n<p><span class=\"gaal-em\">GAALFLEX\u00ae VFD 1000 P features 3-phase + shield conductor configuration (brown\/black\/gray per DIN VDE 0293-308) enabling standardized industrial motor VFD power distribution across all industrial equipment categories<\/span>.<\/p>\n<\/section>\n\n<section id=\"s7\">\n<h2>7. 2.5\u2013300 mm\u00b2 Comprehensive Range: Control to Maximum Motor Power<\/h2>\n<p><span class=\"perf-em\">GAALFLEX\u00ae VFD 1000 P spans comprehensive 2.5\u2013300 mm\u00b2 conductor range with flexible Class 5 red copper enabling complete specification from low-power control circuits through maximum industrial motor systems (300+ kW)<\/span>.<\/p>\n<\/section>\n\n<section id=\"s8\">\n<h2>8. \u221250\/\u221240 to +90\u00b0C Extreme Temperature: Arctic to Tropical Operation<\/h2>\n<p><span class=\"perf-em\">GAALFLEX\u00ae VFD 1000 P provides \u221250\u00b0C fixed\/\u221240\u00b0C flexible minimum through +90\u00b0C maximum enabling arctic mining, extreme-cold industrial facilities, and tropical high-ambient-temperature industrial installations without thermal degradation<\/span>.<\/p>\n<\/section>\n\n<section id=\"s9\">\n<h2>9. Comparative Analysis: VFD 1000 P (GAALTHERM\u00ae 530) vs. 1100 PH (GAALTHERM\u00ae 630) &#038; Standard VFD Cables<\/h2>\n\n<div class=\"tw\">\n<table>\n<caption>Table 9.1-A \u2014 Performance comparison: GAALFLEX VFD 1000 P (GAALTHERM\u00ae 530 standard), VFD 1100 PH (GAALTHERM\u00ae 630 premium), and standard VFD cables<\/caption>\n<thead><tr><th>Metric<\/th><th>Standard VFD PE\/XLPE<\/th><th>VFD 1000 P GAALTHERM\u00ae 530<\/th><th>VFD 1100 PH GAALTHERM\u00ae 630<\/th><th>Winner<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">INSULATION &amp; PERFORMANCE<\/td><\/tr>\n<tr><td>Short-circuit tolerance<\/td><td class=\"num\">180\u2013200\u00b0C typical<\/td><td class=\"winner\">+250\u00b0C GAALTHERM\u00ae 530<\/td><td class=\"num\">280\u00b0C (GAALTHERM\u00ae 630)<\/td><td>1000 P<\/td><\/tr>\n<tr><td>Proprietary insulation<\/td><td class=\"num\">No (standard)<\/td><td class=\"winner\">Yes (GAALTHERM\u00ae 530)<\/td><td class=\"num\">Yes (GAALTHERM\u00ae 630)<\/td><td>1000 P\/1100 PH<\/td><\/tr>\n<tr><td>Cost performance<\/td><td class=\"winner\">Lowest<\/td><td class=\"num\">Moderate<\/td><td class=\"num\">Premium<\/td><td>Standard<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">HALOGEN-FREE &amp; REGULATORY<\/td><\/tr>\n<tr><td>Halogen-free CPR<\/td><td class=\"num\">No<\/td><td class=\"num\">No<\/td><td class=\"winner\">Yes (GAALTHERM\u00ae 630)<\/td><td>1100 PH<\/td><\/tr>\n<tr><td>Building code compliance<\/td><td class=\"num\">Limited<\/td><td class=\"num\">Limited<\/td><td class=\"winner\">Full CPR Cca<\/td><td>1100 PH<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">INSTALLATION &amp; APPLICATION<\/td><\/tr>\n<tr><td>Bending radius flexibility<\/td><td class=\"num\">12\u00d7D typical<\/td><td class=\"winner\">8\u00d7D (most flexible)<\/td><td class=\"num\">Rigid (high-temp)<\/td><td>1000 P<\/td><\/tr>\n<tr><td>Outdoor UV capability<\/td><td class=\"num\">Limited (PVC)<\/td><td class=\"winner\">Yes (PUR)<\/td><td class=\"num\">Limited<\/td><td>1000 P<\/td><\/tr>\n<tr><td>Extreme cold (\u221250\u00b0C)<\/td><td class=\"num\">Limited<\/td><td class=\"winner\">Yes (\u221250\u00b0C fixed)<\/td><td class=\"num\">Yes (\u221250\u00b0C)<\/td><td>1000 P\/1100 PH<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"note perf\">\n<div class=\"nt\">GAALTHERM\u00ae Positioning: 530 vs. 630 Strategy<\/div>\n<p><strong>VFD 1000 P (GAALTHERM\u00ae 530):<\/strong> Standard industrial frequency converter systems requiring extreme short-circuit tolerance (+250\u00b0C) and flexible 8\u00d7D installation. <strong>VFD 1100 PH (GAALTHERM\u00ae 630):<\/strong> Premium halogen-free building code compliance, higher cost, more restricted installation flexibility. Choose 1000 P for cost-effective extreme-performance industrial applications; choose 1100 PH for building-code-required halogen-free installations.<\/p>\n<\/div>\n\n<\/section>\n\n<section id=\"s10\">\n<h2>10. Complete GAALFLEX\u00ae VFD 1000 P SKU Catalog (12+ Extreme-Performance Configurations)<\/h2>\n\n<p>GAALFLEX\u00ae VFD 1000 P extreme-performance VFD cables span comprehensive 2.5\u2013300 mm\u00b2 conductor range with 3-phase + shield configuration optimized for industrial frequency converter systems with exceptional short-circuit tolerance.<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 10.1-B \u2014 GAALFLEX\u00ae VFD 1000 P 600V\/1000V (GAALTHERM\u00ae 530, PUR UV-resistant): Selected SKU portfolio (12+ total configurations) \u2014 3-Phase + Shield Extreme-Performance Version<\/caption>\n<thead><tr><th>Configuration<\/th><th>Size (mm\u00b2)<\/th><th>O.\u00d8 (mm)<\/th><th>Cu Weight (kg\/km)<\/th><th>Cable Weight (kg\/km)<\/th><th>Extreme-Performance Application<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">SMALL POWER (2.5\u201310 mm\u00b2) \u2014 Control &#038; Small Motor Systems<\/td><\/tr>\n<tr><td>3 x 2.5 + SH<\/td><td class=\"num\">2.5 mm\u00b2<\/td><td class=\"num\">14.6<\/td><td class=\"num\">96<\/td><td class=\"num\">340<\/td><td>5 kW extreme motor<\/td><\/tr>\n<tr><td>3 x 6 + SH<\/td><td class=\"num\">6 mm\u00b2<\/td><td class=\"num\">18.7<\/td><td class=\"num\">231<\/td><td class=\"num\">490<\/td><td>15 kW industrial<\/td><\/tr>\n<tr><td>3 x 10 + SH<\/td><td class=\"num\">10 mm\u00b2<\/td><td class=\"num\">21.7<\/td><td class=\"num\">336<\/td><td class=\"num\">720<\/td><td>25 kW system<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">MEDIUM POWER (16\u201350 mm\u00b2) \u2014 Industrial Motor VFD<\/td><\/tr>\n<tr><td>3 x 16 + SH<\/td><td class=\"num\">16 mm\u00b2<\/td><td class=\"num\">25.3<\/td><td class=\"num\">615<\/td><td class=\"num\">1040<\/td><td>40 kW +250\u00b0C rated<\/td><\/tr>\n<tr><td>3 x 25 + SH<\/td><td class=\"num\">25 mm\u00b2<\/td><td class=\"num\">28.8<\/td><td class=\"num\">873<\/td><td class=\"num\">1410<\/td><td>60 kW extreme fault<\/td><\/tr>\n<tr><td>3 x 35 + SH<\/td><td class=\"num\">35 mm\u00b2<\/td><td class=\"num\">32.2<\/td><td class=\"num\">1162<\/td><td class=\"num\">1870<\/td><td>75 kW system<\/td><\/tr>\n<tr><td>3 x 50 + SH<\/td><td class=\"num\">50 mm\u00b2<\/td><td class=\"num\">36<\/td><td class=\"num\">1680<\/td><td class=\"num\">2400<\/td><td>100 kW VFD<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">HIGH POWER (70\u2013300 mm\u00b2) \u2014 Maximum Industrial Motor Applications<\/td><\/tr>\n<tr><td>3 x 95 + SH<\/td><td class=\"num\">95 mm\u00b2<\/td><td class=\"num\">47.6<\/td><td class=\"num\">3192<\/td><td class=\"num\">4350<\/td><td>150+ kW motor<\/td><\/tr>\n<tr><td>3 x 185 + SH<\/td><td class=\"num\">185 mm\u00b2<\/td><td class=\"num\">64.8<\/td><td class=\"num\">6216<\/td><td class=\"num\">8350<\/td><td>300+ kW extreme<\/td><\/tr>\n<tr><td>3 x 240 + SH<\/td><td class=\"num\">240 mm\u00b2<\/td><td class=\"num\">74.5<\/td><td class=\"num\">8604<\/td><td class=\"num\">11540<\/td><td>400 kW system<\/td><\/tr>\n<tr><td>3 x 300 + SH<\/td><td class=\"num\">300 mm\u00b2<\/td><td class=\"num\">85.5<\/td><td class=\"num\">10080<\/td><td class=\"num\">13480<\/td><td>Maximum industrial<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">All GAALFLEX\u00ae VFD 1000 P SKUs (3-phase + shield extreme-performance): 600V\/1000V (0.6\/1 kV), proprietary GAALTHERM\u00ae 530 insulation, flexible Class 5 red copper (IEC 60228, DIN VDE 0295), aluminum tape (100% covering) + red copper braid shielding (equal to phase \u226416 mm\u00b2 or \u226550% phase \u226516 mm\u00b2 for >25 mm\u00b2), black RAL 9005 PUR UV-resistant outer sheath, 3-phase brown\/black\/gray + shield per DIN VDE 0293-308, 2.5\u2013300 mm\u00b2 comprehensive range, 8\u00d7D minimum bending radius (most flexible available), temperature \u221250\/\u221240 to +90\u00b0C extreme arctic\/tropical, +90\u00b0C maximum conductor operating, +250\u00b0C maximum short-circuit (exceptional tolerance), 4 kV test voltage per DIN VDE, 3-phase + shield configuration, DIN VDE 0482-265-2-1 \/ EN 50265-2-1 \/ IEC 60332-1-2 flame-retardant &#038; self-extinguishing, UV resistance per IEC 60502-1 \/ CEI 20-13 \/ CEI-UNEL 35375, EMC per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, optional GAALFLEX\u00ae VFD 1000 PH halogen-free version with proprietary GAALTHERM\u00ae 630 insulation on request, RoHS &#038; CE certified. Optimized for industrial extreme-performance frequency converter systems (2.5\u2013300 mm\u00b2 complete motor spectrum), exceptional short-circuit survivability (+250\u00b0C) for fault-condition tolerance, PUR UV-resistant outdoor installation, extreme temperature range (\u221250 to +90\u00b0C arctic\/tropical), flexible 8\u00d7D industrial routing (motor junction boxes, equipment cabinets), European standard (600V\/1000V 0.6\/1 kV) specification, industrial motor protection system compliance, hazardous-area optional capability, and comprehensive European extreme-performance industrial VFD automation infrastructure with proprietary GAALTHERM\u00ae 530 insulation, exceptional +250\u00b0C short-circuit tolerance, UV-resistant PUR jacket, extreme flexibility (8\u00d7D), extreme temperature range, and professional high-performance frequency converter system integration with complete industrial motor power distribution capability.<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/section>\n\n<\/section>\n\n<section class=\"refs\">\n<h2>Technical References<\/h2>\n<ol class=\"rl\">\n<li>Feichun Cable Engineering. (2023). <em>GAALTHERM\u00ae 530: Proprietary Thermoplastic Insulation for Industrial VFD Cables<\/em>.<\/li>\n<li>Feichun Cable Engineering. (2023). <em>GAALTHERM\u00ae 630: Proprietary Halogen-Free Thermoplastic for Building-Code Compliance<\/em>.<\/li>\n<li>IEC. (2023). <em>IEC 60502-1: Power Cables with Extruded Insulation\u2014Part 1: General Requirements<\/em>.<\/li>\n<li>IEC. (2023). <em>IEC 60502: Underground Installation Power Cables<\/em>.<\/li>\n<li>CEI. (2023). <em>CEI 20-13: Electrical Safety Standard for Industrial Cables<\/em>.<\/li>\n<li>UNEL. (2023). <em>CEI-UNEL 35375: UV Resistance Testing for Extruded Insulation<\/em>.<\/li>\n<li>DIN VDE. (2023). <em>DIN VDE 0482-265-2-1: Flame Propagation Test\u2014Thermal Durability<\/em>.<\/li>\n<li>European Committee. (2023). <em>EN 50265-2-1: Fire Safety Test Methods for Cables<\/em>.<\/li>\n<li>Feichun Cable Engineering. (2023). <em>VFD 1000 P: Extreme-Performance GAALTHERM\u00ae 530 Industrial VFD Cable<\/em>.<\/li>\n<li>Industrial Motor Protection Standards. (2023). <em>Short-Circuit Temperature Survivability: +250\u00b0C Design Principles<\/em>.<\/li>\n<\/ol>\n<\/section>\n\n<section class=\"contact\">\n<h3>European Extreme-Performance Industrial VFD Cable Solutions<\/h3>\n<p style=\"margin-bottom:1rem;color:var(--c-secondary);font-size:.88rem\">For 600V\/1000V European standard extreme-performance frequency converter cable solutions with GAALTHERM\u00ae 530 insulation, exceptional +250\u00b0C short-circuit tolerance, UV-resistant PUR jacket, and flexible 8\u00d7D installation: <a href=\"mailto:Tech@feichuncables.com\" style=\"color:var(--c-link);text-decoration:none\">Tech@feichuncables.com<\/a> | Industrial Drive Solutions Division | Anhui Feichun Special Cable Co., Ltd.<\/p>\n<div class=\"cg\">\n<div class=\"ci\"><span class=\"lb\">GAALTHERM\u00ae 530 Extreme Performance<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">+250\u00b0C Short-Circuit Rated<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">8\u00d7D Flexible Installation<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Industrial Drive Solutions Division<\/span>Anhui Feichun Special Cable Co., Ltd.<\/div>\n<\/div>\n<\/section>\n\n<footer class=\"ft\">\n<p><strong>GAALFLEX\u00ae VFD 1000 P: 600V\/1000V European Standard Extreme-Performance VFD Cable with GAALTHERM\u00ae 530 Insulation &#038; +250\u00b0C Short-Circuit Tolerance<\/strong> \u2014 600V\/1000V dual-voltage extreme-performance VFD cable, proprietary GAALTHERM\u00ae 530 insulation, exceptional +250\u00b0C maximum short-circuit temperature, PUR UV-resistant outer jacket per IEC 60502-1\/CEI 20-13, aluminum tape (100% covering) + red copper braid shielding, black RAL 9005 outer sheath, flexible Class 5 red copper per IEC 60228, 2.5\u2013300 mm\u00b2 comprehensive range, 3-phase brown\/black\/gray + shield per DIN VDE 0293-308, 8\u00d7D minimum bending radius (most flexible), temperature \u221250\/\u221240 to +90\u00b0C extreme arctic\/tropical, +90\u00b0C conductor \/ +250\u00b0C short-circuit rated, 4 kV test voltage, DIN VDE\/EN\/IEC fire-retardant &#038; self-extinguishing, UV resistant per IEC 60502-1\/CEI 20-13, EMC per EN 55011\/DIN VDE 0875\/EN 61800-3, optional VFD 1000 PH with GAALTHERM\u00ae 630 halogen-free upgrade, RoHS &#038; CE certified. Comprehensive portfolio (12+ extreme-performance SKUs) for European and international extreme-temperature industrial motor VFD systems with exceptional short-circuit tolerance.<\/p>\n<p style=\"margin-top:.6rem\">European extreme-performance industrial VFD cable for frequency converter systems: 600V\/1000V dual-voltage European standard (0.6\/1 kV) specification, exceptional +250\u00b0C short-circuit temperature survivability enabling extreme fault conditions and motor stall events without cable failure, PUR UV-resistant outdoor installation capability, extreme flexibility (8\u00d7D minimum bending radius) for motor junction boxes and equipment cabinets, extreme temperature range (\u221250 to +90\u00b0C arctic to tropical operation), proprietary GAALTHERM\u00ae 530 insulation providing cost-effective extreme-performance characteristics, optional halogen-free GAALTHERM\u00ae 630 upgrade for building code compliance, complete 2.5\u2013300 mm\u00b2 industrial motor spectrum coverage, and comprehensive European extreme-performance industrial VFD automation infrastructure with exceptional short-circuit tolerance, extreme flexibility, UV-resistant outdoor capability, and professional high-performance frequency converter system integration with complete industrial motor power distribution.<\/p>\n<\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"GAALFLEX\u00ae VFD 1000 P: 600V\/1000V European Standard Variable Frequency Drive Cable with Proprietary GAALTHERM\u00ae 530 Insulation, Extreme +250\u00b0C Short-Circuit Tolerance, UV-Resistant PUR Jacket, Aluminum Tape + Red Copper Braid Shielding, 3-Phase Industrial Motor, 2.5\u2013300 mm\u00b2 Flexible Class 5, 8\u00d7D Minimum Bending Radius, \u221250\/\u221240 to +90\u00b0C Temperature Range, Industrial Frequency Converter Integration, Optional GAALFLEX\u00ae VFD 1000 PH Halogen-Free (GAALTHERM\u00ae 630 Upgrade) | European Extreme-Performance Industrial VFD Cable\nUL-certified European standard 600V\/1000V extreme-performance VFD cable combining proprietary GAALTHERM\u00ae 530 insulation with exceptional electrical stability and exceptional +250\u00b0C short-circuit tolerance, flexible Class 5 red copper, aluminum tape + red copper braid shielding, UV-resistant PUR outer jacket, and professional extreme-condition industrial motor integration\u2014addressing extreme-performance frequency converter specification (600V\/1000V), industrial motor control, exceptional short-circuit fault conditions (+250\u00b0C maximum), outdoor UV-resistant installation, flexible motor routing (8\u00d7D bend radius), hazardous-environment capability, and comprehensive European extreme-performance industrial automation infrastructure simultaneously.","protected":false},"author":1,"featured_media":11740,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,165,35],"tags":[57887,57896,57512,57893,57892,51947,56940,57889,57864,57895,57886,57884,57894,57888,57672,44920,57891,57890,57885,1247],"class_list":["post-11739","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-drag-chain-cable","category-festoon-cable","tag-250c-short-circuit-tolerance","tag-50c-to-90c","tag-1000v","tag-2-5-300-mm","tag-3-phase-industrial-motor","tag-600v","tag-8xd-bending-radius-2","tag-aluminum-tape-shielding","tag-european-standard","tag-extreme-performance","tag-flexible-class-5-red-copper","tag-gaalflex-vfd-1000-p","tag-gaalflex-vfd-1000-ph","tag-gaaltherm-530-insulation","tag-gaaltherm-630","tag-halogen-free-2","tag-industrial-frequency-converter","tag-red-copper-braid-shielding","tag-uv-resistant-pur-jacket","tag-variable-frequency-drive-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=11739"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11739\/revisions"}],"predecessor-version":[{"id":11742,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11739\/revisions\/11742"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/11740"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=11739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=11739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=11739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}