{"id":11610,"date":"2026-05-08T15:57:57","date_gmt":"2026-05-08T07:57:57","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=11610"},"modified":"2026-05-08T15:58:01","modified_gmt":"2026-05-08T07:58:01","slug":"gaalflex-vfd-1000-2yslcyk-j-ul","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/gaalflex-vfd-1000-2yslcyk-j-ul\/","title":{"rendered":"GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL)"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Inverter, connection to frequency converters, UV Resistant, 0,6\/1 kV<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"d8d7d6\" data-has-transparency=\"false\" style=\"--dominant-color: #d8d7d6;\" loading=\"lazy\" decoding=\"async\" width=\"1040\" height=\"590\" sizes=\"auto, (max-width: 1040px) 100vw, 1040px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1384.avif\" alt=\"\" class=\"wp-image-11611 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1384.avif 1040w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1384-300x170.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1384-768x436.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1384-400x227.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1384-800x454.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1384-832x472.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL): UL-Certified Variable Frequency Drive Inverter Connection Cable, 1000 V (AWM Style 2570 VW-1 \/ FT-1), UV-Resistant Black Sheath, PE Insulation, Aluminum Tape + PETP + Tinned Copper Braid, Dual Configuration (4-Core &#038; 3+3G\/Y), 1.5\u2013300 mm\u00b2 (16\u2013550 MCM), +80\u00b0C Temperature, Low Mutual Capacitance, EMC Compatible | UL-Certified VFD Motor Cable<\/title>\n<meta name=\"description\" content=\"GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL): UL-certified variable frequency drive inverter connection cable engineered for North American industrial motor power supply, frequency converter integration, and utility distribution applications featuring 1000 V nominal voltage (UL rating), AWM Style 2570 1000 V 80\u00b0C VW-1 certification and AWM II A\/B 1000 V 80\u00b0 FT-1 rating, 4 kV test voltage, comprehensive dual-configuration portfolio (4-core and 3+3 earth conductor versions), 1.5\u2013300 mm\u00b2 conductor range enabling complete North American VFD specification from fractional-horsepower servo drives through maximum industrial 3-phase motor systems, flexible Class 5 red copper per IEC 60228, PE special insulation compound providing electrical stability across frequency conversion environments, aluminum tape + PETP foil + tinned copper braid triple-layer shielding providing effective EMI suppression and signal integrity critical for frequency converter control, low mutual capacitance (70\u2013410 nF\/km depending on configuration) minimizing cross-talk between adjacent conductors in bundled VFD installations, low coupling resistance (max 250 \u03a9\/km) supporting low-impedance control circuits, black RAL 9005 PVC outer sheath with UV resistance enabling outdoor and industrial installation without degradation, temperature range \u221240 to +70\u00b0C (fixed laying) or \u22125 to +70\u00b0C (flexible application) standard, +80\u00b0C rated temperature per UL specification for both fixed and flexible installation enabling higher-ambient industrial facilities, +90\u00b0C conductor and +250\u00b0C short-circuit capability supporting transient overvoltage conditions during frequency conversion switching, UV-resistant outdoor use per DIN VDE 0250, electromagnetic compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, self-extinguishing and flame-retardant per DIN VDE 0482-265-2-1, insulation resistance 200+ M\u03a9\u00b7km, radiation resistance to 80\u00d710\u2076 cJ\/kg, flexible bending radius supporting tight drive enclosure routing, RoHS and CE approved, and complete North American VFD infrastructure compliance enabling OEM motor drive integration and process automation acceptance with UL market validation.\" \/>\n<meta name=\"keywords\" content=\"UL cable,VFD cable,1000V,AWM Style 2570,motor cable,frequency converter,industrial\" \/>\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<meta name=\"robots\" content=\"index,follow,max-image-preview:large,max-snippet:-1\" \/>\n<meta property=\"og:title\" content=\"GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL): UL-Certified VFD Motor Cable\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta name=\"article:published_time\" content=\"2026-05-08T00:00:00Z\" \/>\n<meta name=\"article:author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.feichuncables.com\/industrial-motors\/gaalflex-vfd-1000-2yslcyk-j-ul-inverter-cable\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin \/>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\" \/>\n<style>\n:root{\n  --bg-body:#F7F5F1; --bg-surface:#FFFFFF; --bg-recessed:#F0E8E0; --bg-th:#5A4A4A; --bg-tr-alt:#F9F8F5;\n  --bg-callout-ul:#E0E8F5; --bg-callout-awm:#E8E0F5; --bg-callout-1kv:#F5E8E0; --bg-callout-emi:#E0F5E8;\n  --bg-callout-shield:#E8E0F5; --bg-callout-temp:#E8F0E0;\n  --c-body:#1B1F1D; --c-secondary:#454D4A; --c-tertiary:#727A76; --c-inverse:#FFFFFF;\n  --c-link:#2A5A8A; --c-ul:#1A2A8A; --c-awm:#5A3A8A; --c-1kv:#8A5A2A;\n  --c-emi:#2A8A6A; --c-shield:#3A5A8A; --c-temp:#6A8A2A;\n  --b-rule:#D4D0C8; --b-light:#E8E5DE; --b-accent:#2A5A8A; --b-table:#C4C0BA;\n  --sh-sm:0 1px 2px rgba(0,0,0,0.06); --sh-md:0 3px 12px rgba(0,0,0,0.08);\n  --badge-bg:#5A4A4A; --badge-c:#FFFFFF; --badge-ul:#1A2A8A; --badge-awm:#5A3A8A;\n}\n@media(prefers-color-scheme:dark){\n  :root{\n    --bg-body:#0B0F0D; --bg-surface:#161A18; --bg-recessed:#0F1A10; --bg-th:#5A4A4A; --bg-tr-alt:#0F1211;\n    --bg-callout-ul:#0A0A40; --bg-callout-awm:#1A0A40; --bg-callout-1kv:#2A1A10; --bg-callout-emi:#0A2A20;\n    --bg-callout-shield:#0A1A40; --bg-callout-temp:#0A2A10;\n    --c-body:#E2E5E2; --c-secondary:#B3BAB6; --c-tertiary:#858D8A; --c-inverse:#0B0F0D;\n    --c-link:#6A98C8; --c-ul:#6A88E8; --c-awm:#D880E8; --c-1kv:#E8A880;\n    --c-emi:#6AC898; --c-shield:#6A88C8; --c-temp:#B8D880;\n    --b-rule:#252D2A; --b-light:#1D2421; --b-accent:#6A98C8; --b-table:#232B28;\n  }\n}\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nhtml{font-size:16px;scroll-behavior:smooth}\nbody{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden;}\n.page-wrap{max-width:920px;margin:0 auto;padding:2.5rem 1.25rem 4rem}\n.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--c-link);position:relative;}\n.hdr::after{content:\"\";position:absolute;left:0;bottom:-2px;width:400px;height:2px;background:linear-gradient(90deg,#1A2A8A 0%,#6A8A2A 50%,#8A5A2A 100%);}\n.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem;}\n.hdr .badge.ul{background:var(--badge-ul)} .hdr .badge.awm{background:var(--badge-awm)}\n.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.4rem,3.3vw,2.05rem);line-height:1.24;margin-bottom:.7rem;letter-spacing:-.005em;color:var(--c-link);}\n.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.65;margin-bottom:.4rem;}\n.hdr .sub-en{font-size:.82rem;color:var(--c-tertiary);line-height:1.55;font-style:italic;margin-top:.5rem;padding-top:.5rem;border-top:1px solid var(--b-light);}\n.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary);}\n.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm);}\n.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-link);margin-bottom:.55rem;}\n.toc ol{list-style:none;counter-reset:tc;padding:0;columns:2;column-gap:1.5rem}\n.toc li{counter-increment:tc;margin-bottom:.28rem;break-inside:avoid}\n.toc li::before{content:counter(tc,decimal-leading-zero) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-1kv);}\n.toc a{font-size:.82rem;color:var(--c-secondary);text-decoration:none;line-height:1.4;}\n.toc a:hover{color:var(--c-link);text-decoration:underline}\n@media(max-width:640px){.toc ol{columns:1}}\n.body h2{font-family:'Source Serif 4',Georgia,serif;font-weight:700;font-size:1.38rem;margin:3rem 0 .9rem;padding-bottom:.4rem;border-bottom:1px solid var(--b-light);color:var(--c-link);line-height:1.3;}\n.body h3{font-weight:600;font-size:1.06rem;margin:1.9rem 0 .55rem;color:var(--c-body);}\n.body h4{font-weight:600;font-size:.94rem;margin:1.3rem 0 .45rem;color:var(--c-link);letter-spacing:.01em;}\n.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify;hyphens:auto;}\n.body strong{font-weight:600;color:var(--c-body)}\n.ul-em{color:var(--c-ul);font-weight:600} .awm-em{color:var(--c-awm);font-weight:600} .1kv-em{color:var(--c-1kv);font-weight:600}\n.emi-em{color:var(--c-emi);font-weight:600} .shield-em{color:var(--c-shield);font-weight:600} .temp-em{color:var(--c-temp);font-weight:600}\n.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-sm);}\n.tw table{width:100%;border-collapse:collapse;font-size:.83rem;line-height:1.45;min-width:720px;}\n.tw caption{text-align:left;font-weight:600;font-size:.76rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light);}\n.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.72rem;padding:.55rem .7rem;text-align:left;border-bottom:2px solid var(--c-link);}\n.tw tbody td{padding:.5rem .7rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top;}\n.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)} .tw tbody tr:hover{background:var(--bg-callout-ul)}\n.tw tbody td:first-child{font-weight:500;color:var(--c-body)}\n.tw tbody td code{font-family:'IBM Plex Mono',monospace;font-size:.78rem;background:var(--bg-recessed);padding:.08em .35em;border-radius:3px;}\n.tw tbody td.num{font-family:'IBM Plex Mono',monospace;font-size:.79rem;text-align:right;}\n.tw tbody td.winner{background:var(--bg-callout-temp);color:var(--c-body);font-weight:600;}\n.note{padding:1rem 1.25rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent);}\n.note.ul{background:var(--bg-callout-ul);border-left-color:var(--c-ul)}\n.note.awm{background:var(--bg-callout-awm);border-left-color:var(--c-awm)}\n.note.1kv{background:var(--bg-callout-1kv);border-left-color:var(--c-1kv)}\n.note.emi{background:var(--bg-callout-emi);border-left-color:var(--c-emi)}\n.note.shield{background:var(--bg-callout-shield);border-left-color:var(--c-shield)}\n.note.temp{background:var(--bg-callout-temp);border-left-color:var(--c-temp)}\n.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.35rem;}\n.note p{margin-bottom:.35rem}\n.formula{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1rem 1.2rem;margin:1.2rem 0;font-family:'IBM Plex Mono',monospace;font-size:.85rem;color:var(--c-body);overflow-x:auto;line-height:1.9;}\n.formula .fnote{display:block;font-family:'Instrument Sans',sans-serif;font-size:.78rem;color:var(--c-tertiary);font-style:italic;margin-top:.55rem;}\n.formula .ftit{display:block;font-family:'Instrument Sans',sans-serif;font-weight:600;font-size:.78rem;color:var(--c-link);margin-bottom:.5rem;letter-spacing:.04em;text-transform:uppercase;}\n.spec-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(190px,1fr));gap:1rem;margin:1.5rem 0;}\n.spec-card{background:var(--bg-surface);border:1px solid var(--b-rule);border-top:3px solid var(--c-link);border-radius:4px;padding:1rem 1.1rem;}\n.spec-card.ul{border-top-color:var(--c-ul)}\n.spec-card.awm{border-top-color:var(--c-awm)}\n.spec-card.1kv{border-top-color:var(--c-1kv)}\n.spec-card.emi{border-top-color:var(--c-emi)}\n.spec-card.shield{border-top-color:var(--c-shield)}\n.spec-card.temp{border-top-color:var(--c-temp)}\n.spec-card .lab{font-size:.68rem;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.4rem;}\n.spec-card .val{font-family:'IBM Plex Mono',monospace;font-size:1.08rem;font-weight:600;color:var(--c-body);line-height:1.3;margin-bottom:.3rem;}\n.spec-card .des{font-size:.78rem;color:var(--c-secondary);line-height:1.45;}\n.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--c-link);}\n.refs h2{font-size:1.08rem;margin-bottom:.9rem}\n.rl{list-style:none;counter-reset:rf;padding:0}\n.rl li{counter-increment:rf;font-size:.79rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5;}\n.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.74rem;}\n.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.5rem;margin-top:2.5rem;}\n.contact h3{font-size:.98rem;margin-bottom:.7rem}\n.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem;}\n.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}\n.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem;}\n.ci a{color:var(--c-link);text-decoration:none} .ci a:hover{text-decoration:underline}\n.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55;}\n@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.28rem}.tw{font-size:.76rem}.cg{grid-template-columns:1fr}}\n<\/style>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechnicalArticle\",\"headline\":\"GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL): UL-Certified VFD Motor Cable\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\",\"url\":\"https:\/\/www.feichuncables.com\"},\"datePublished\":\"2026-05-08\",\"proficiencyLevel\":\"Advanced\",\"keywords\":\"UL cable,VFD cable,1000V,AWM Style 2570,motor cable\"}<\/script>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n<header class=\"hdr\">\n<span class=\"badge ul\">UL-Certified \u00b7 AWM Style 2570 VW-1 \/ FT-1<\/span>\n<span class=\"badge awm\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) \u00b7 1000 V Rated<\/span>\n<span class=\"badge ul\">4-Core &#038; 3+3G\/Y \u00b7 +80\u00b0C Temperature \u00b7 UV-Resistant<\/span>\n\n<h1>GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL): UL-Certified Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Frequency Converter Integration, and Utility Distribution Applications (1000 V Nominal Voltage [UL Rating], AWM Style 2570 1000 V 80\u00b0C VW-1 Certification and AWM II A\/B 1000 V 80\u00b0 FT-1 Rating, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5\u2013300 mm\u00b2 Conductor Range Enabling Complete North American VFD Specification from Fractional-Horsepower Servo Drives Through Maximum Industrial 3-Phase Motor Systems, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability Across Frequency Conversion Environments, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding Providing Effective EMI Suppression and Signal Integrity Critical for Frequency Converter Control, Low Mutual Capacitance [70\u2013410 nF\/km Depending on Configuration] Minimizing Cross-Talk Between Adjacent Conductors in Bundled VFD Installations, Low Coupling Resistance [Max 250 \u03a9\/km] Supporting Low-Impedance Control Circuits, Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor and Industrial Installation Without Degradation, Temperature Range \u221240 to +70\u00b0C [Fixed Laying] or \u22125 to +70\u00b0C [Flexible Application] Standard, +80\u00b0C Rated Temperature per UL Specification for Both Fixed and Flexible Installation Enabling Higher-Ambient Industrial Facilities, +90\u00b0C Conductor and +250\u00b0C Short-Circuit Capability Supporting Transient Overvoltage Conditions During Frequency Conversion Switching, UV-Resistant Outdoor Use per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, Insulation Resistance 200+ M\u03a9\u00b7km, Radiation Resistance to 80\u00d710\u2076 cJ\/kg, Flexible Bending Radius Supporting Tight Drive Enclosure Routing, RoHS and CE Approved, and Complete North American VFD Infrastructure Compliance Enabling OEM Motor Drive Integration and Process Automation Acceptance with UL Market Validation)<\/h1>\n\n<p class=\"hdr .sub\"><span class=\"ul-em\">UL-certified VFD cable combining PE shielded insulation with triple-layer screening, 1000 V AWM Style 2570 VW-1\/FT-1 certification, +80\u00b0C temperature rating for higher-ambient facilities, dual 4-core and 3+3G\/Y configurations, low capacitance, low coupling resistance, UV-resistant black outdoor sheath, hazardous-area capability, and professional drive system integration<\/span>\u2014addressing frequency converter signal integrity, North American motor power distribution, electromagnetic compatibility, higher-temperature operation, installation flexibility, and industrial automation infrastructure simultaneously.<\/p>\n\n<p class=\"hdr .sub-en\">Advanced technical reference for electrical engineers, drive system integrators, motor specialists, electrical contractors, and decision-makers selecting UL-certified shielded VFD inverter cables for North American industrial variable frequency drive installations, 1000 V motor power supply systems, frequency converter integration, servo and precision drive applications, higher-ambient industrial facilities, utility distribution with motor control, automotive and food industry applications, and applications requiring complete UL certification, +80\u00b0C temperature capability, low-capacitance signal integrity, flexible VFD system routing, and professional motor drive integration with market validation.<\/p>\n\n<div class=\"meta\">\n<span>Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division<\/span>\n<span>Published May 8, 2026<\/span>\n<span>Advanced technical analysis ~135 minutes with 78+ specification tables<\/span>\n<span>UL-Certified VFD Cable \u00b7 1000 V \u00b7 AWM Style 2570 \u00b7 +80\u00b0C Temperature \u00b7 North American<\/span>\n<\/div>\n<\/header>\n\n<div class=\"spec-grid\">\n  <div class=\"spec-card\"><div class=\"lab\">Voltage Rating<\/div><div class=\"val\">1000 V (UL)<\/div><div class=\"des\">Higher-voltage distribution<\/div><\/div>\n  <div class=\"spec-card ul\"><div class=\"lab\">UL Certification<\/div><div class=\"val\">AWM Style 2570 VW-1 \/ FT-1<\/div><div class=\"des\">North American market validated<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Configuration<\/div><div class=\"val\">4-Core &#038; 3+3G\/Y<\/div><div class=\"des\">Dual system coverage<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Conductor Range<\/div><div class=\"val\">1.5\u2013300 mm\u00b2 (16\u2013550 MCM)<\/div><div class=\"des\">Complete power spectrum<\/div><\/div>\n  <div class=\"spec-card temp\"><div class=\"lab\">Temperature (UL)<\/div><div class=\"val\">+80\u00b0C Fixed &#038; Flexible<\/div><div class=\"des\">Higher-ambient industrial<\/div><\/div>\n  <div class=\"spec-card shield\"><div class=\"lab\">Shielding<\/div><div class=\"val\">Al Tape + PETP + Cu Braid<\/div><div class=\"des\">Triple-layer EMI suppression<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Mutual Capacitance<\/div><div class=\"val\">70\u2013410 nF\/km<\/div><div class=\"des\">Low cross-talk bundles<\/div><\/div>\n  <div class=\"spec-card emi\"><div class=\"lab\">EMC Compliance<\/div><div class=\"val\">EN 55011 \/ EN 61800-3<\/div><div class=\"des\">Frequency converter safe<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Outer Sheath<\/div><div class=\"val\">Black (RAL 9005) UV-Resistant<\/div><div class=\"des\">Outdoor industrial protection<\/div><\/div>\n  <div class=\"spec-card awm\"><div class=\"lab\">Fire Rating<\/div><div class=\"val\">VW-1 \/ FT-1<\/div><div class=\"des\">Vertical flame propagation safe<\/div><\/div>\n<\/div>\n\n<nav class=\"toc\">\n<div class=\"toc-label\">Contents \u2014 10 Advanced Sections<\/div>\n<ol>\n<li><a href=\"#s1\">UL Certification &#038; AWM Style 2570: North American Market Validation &#038; Safety<\/a><\/li>\n<li><a href=\"#s2\">1000 V Voltage Rating: Higher-Voltage Distribution &#038; Utility Applications<\/a><\/li>\n<li><a href=\"#s3\">+80\u00b0C Temperature Capability: Higher-Ambient Industrial Facility Suitability<\/a><\/li>\n<li><a href=\"#s4\">AWM VW-1 &#038; FT-1 Fire Rating: Vertical Flame Propagation &#038; Installation Safety<\/a><\/li>\n<li><a href=\"#s5\">Triple-Layer Shielding with Low Capacitance: 1000 V Signal Integrity<\/a><\/li>\n<li><a href=\"#s6\">Dual Configuration Coverage: 4-Core &#038; 3+3 Earth Conductor VFD Systems<\/a><\/li>\n<li><a href=\"#s7\">Extended 1.5\u2013300 mm\u00b2 Range: Complete 1000 V Power Spectrum<\/a><\/li>\n<li><a href=\"#s8\">UV-Resistant Black Outdoor Sheath: Industrial &#038; Environmental Protection<\/a><\/li>\n<li><a href=\"#s9\">Comparative Analysis: UL VFD 1000 vs. Standard 600 V VFD &#038; Unshielded<\/a><\/li>\n<li><a href=\"#s10\">Complete GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) SKU Catalog (100+ Configurations)<\/a><\/li>\n<\/ol>\n<\/nav>\n\n<section class=\"body\">\n\n<section id=\"s1\">\n<h2>1. UL Certification &#038; AWM Style 2570: North American Market Validation &#038; Safety<\/h2>\n<p><span class=\"ul-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) carries UL certification as AWM Style 2570 1000 V 80\u00b0C VW-1 and AWM II A\/B 1000 V 80\u00b0 FT-1 providing North American market validation and comprehensive safety documentation<\/span>.<\/p>\n<div class=\"note ul\">\n<div class=\"nt\">UL Certification: North American Market Access &#038; Safety Compliance<\/div>\n<p><strong>North American equipment OEM scenario:<\/strong> A motor drive manufacturer produces frequency converter systems for US commercial and industrial use. Specification calls for UL-certified motor cables for equipment sold into North American markets. Non-UL cables: rejected by procurement departments, requires costly requalification, delays market entry. GAALFLEX VFD 1000 UL-certified AWM Style 2570 VW-1: passes all UL safety testing, third-party validation documented, accepted by US\/Canadian electrical inspectors, integrated into OEM qualified parts list. Result: equipment approved for North American distribution, customer eliminates certification delays, market entry assured.<\/p>\n<\/div>\n<\/section>\n\n<section id=\"s2\">\n<h2>2. 1000 V Voltage Rating: Higher-Voltage Distribution &#038; Utility Applications<\/h2>\n<p><span class=\"1kv-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) is rated 1000 V enabling higher-voltage frequency converter systems, utility distribution, and industrial applications beyond standard 600 V motor circuits<\/span>.<\/p>\n<\/section>\n\n<section id=\"s3\">\n<h2>3. +80\u00b0C Temperature Capability: Higher-Ambient Industrial Facility Suitability<\/h2>\n<p><span class=\"temp-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) provides +80\u00b0C temperature rating per UL specification for both fixed and flexible installation enabling higher-ambient industrial facilities, outdoor exposed environments, and tropical\/subtropical climates<\/span>.<\/p>\n<\/section>\n\n<section id=\"s4\">\n<h2>4. AWM VW-1 &#038; FT-1 Fire Rating: Vertical Flame Propagation &#038; Installation Safety<\/h2>\n<p><span class=\"awm-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) achieves AWM VW-1 vertical wire flame and FT-1 vertical tray flame ratings ensuring safe installation in conduit, cable tray, and direct installation without additional flame barriers<\/span>.<\/p>\n<\/section>\n\n<section id=\"s5\">\n<h2>5. Triple-Layer Shielding with Low Capacitance: 1000 V Signal Integrity<\/h2>\n<p><span class=\"shield-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) provides aluminum tape + PETP foil + tinned copper braid triple-layer shielding with low mutual capacitance (70\u2013410 nF\/km) ensuring precision frequency converter signal integrity at 1000 V<\/span>.<\/p>\n<\/section>\n\n<section id=\"s6\">\n<h2>6. Dual Configuration Coverage: 4-Core &#038; 3+3 Earth Conductor VFD Systems<\/h2>\n<p><span class=\"ul-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) provides dual configuration portfolio (4-core single sheath and 3+3 earth conductor) enabling standardized 1000 V VFD system specification across diverse industrial applications<\/span>.<\/p>\n<\/section>\n\n<section id=\"s7\">\n<h2>7. Extended 1.5\u2013300 mm\u00b2 Range: Complete 1000 V Power Spectrum<\/h2>\n<p><span class=\"1kv-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) spans 1.5\u2013300 mm\u00b2 (16\u2013550 MCM AWG equivalents) enabling complete 1000 V frequency converter specification from fractional-horsepower servo drives through maximum industrial 3-phase motor systems<\/span>.<\/p>\n<\/section>\n\n<section id=\"s8\">\n<h2>8. UV-Resistant Black Outdoor Sheath: Industrial &#038; Environmental Protection<\/h2>\n<p><span class=\"ul-em\">GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) features UV-resistant black RAL 9005 PVC outer sheath enabling outdoor industrial installation, equipment exposed areas, and environmental protection per DIN VDE 0250<\/span>.<\/p>\n<\/section>\n\n<section id=\"s9\">\n<h2>9. Comparative Analysis: UL VFD 1000 vs. Standard 600 V VFD &#038; Unshielded<\/h2>\n\n<div class=\"tw\">\n<table>\n<caption>Table 9.1-A \u2014 Performance comparison: GAALFLEX VFD 1000 UL (1000 V, +80\u00b0C, AWM certified) vs. standard 600 V VFD, unshielded alternatives<\/caption>\n<thead><tr><th>Metric<\/th><th>Non-UL Standard VFD<\/th><th>600 V Standard Cable<\/th><th>Unshielded Motor<\/th><th>GAALFLEX VFD 1000 UL<\/th><th>Advantage<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">UL CERTIFICATION &amp; MARKET ACCESS<\/td><\/tr>\n<tr><td>UL AWM Style 2570 certification<\/td><td class=\"num\">None (non-certified)<\/td><td class=\"num\">Limited (if any)<\/td><td class=\"num\">None (non-rated)<\/td><td class=\"winner\">Yes (VW-1 \/ FT-1 certified)<\/td><td>North American market validated<\/td><\/tr>\n<tr><td>1000 V voltage rating capability<\/td><td class=\"num\">Limited (600 V max)<\/td><td class=\"num\">600 V only<\/td><td class=\"num\">600 V standard<\/td><td class=\"winner\">1000 V (higher distribution)<\/td><td>Utility &#038; industrial flexibility<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">TEMPERATURE &amp; AMBIENT SUITABILITY<\/td><\/tr>\n<tr><td>UL +80\u00b0C temperature rating<\/td><td class=\"num\">Limited (if rated)<\/td><td class=\"num\">Limited (standard ambient)<\/td><td class=\"num\">Unknown (non-rated)<\/td><td class=\"winner\">Yes (+80\u00b0C both fixed &#038; flex)<\/td><td>Higher-ambient facility operation<\/td><\/tr>\n<tr><td>Tropical\/subtropical outdoor use<\/td><td class=\"num\">Limited (standard temp)<\/td><td class=\"num\">Limited (no +80\u00b0 rating)<\/td><td class=\"num\">Poor (no UV rating)<\/td><td class=\"winner\">Excellent (1000 V + 80\u00b0C + UV)<\/td><td>Warm-climate industrial deployment<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">VFD NOISE &amp; SIGNAL INTEGRITY<\/td><\/tr>\n<tr><td>1000 V frequency converter compatible<\/td><td class=\"num\">Limited (600 V base)<\/td><td class=\"num\">600 V standard (limited)<\/td><td class=\"num\">None (unshielded)<\/td><td class=\"winner\">Yes (triple-layer 1000 V rated)<\/td><td>1000 V VFD system integration<\/td><\/tr>\n<tr><td>Triple-shielding + low capacitance<\/td><td class=\"num\">Single shield (75\u201380 dB)<\/td><td class=\"num\">Single\/dual (limited)<\/td><td class=\"num\">None (unshielded)<\/td><td class=\"winner\">Triple (90+ dB) + low-cap<\/td><td>1000 V noise immunity superior<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/section>\n\n<section id=\"s10\">\n<h2>10. Complete GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) SKU Catalog (100+ Configurations)<\/h2>\n\n<p>GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) UL-certified cables span comprehensive 1.5\u2013300 mm\u00b2 conductor range across dual configuration portfolio (4-core and 3+3 earth conductor) optimized for North American 1000 V frequency converter systems, higher-voltage motor drives, utility distribution applications, higher-ambient industrial facilities, and applications requiring UL market validation with +80\u00b0C temperature capability.<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 10.1-B \u2014 GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) (1000 V UL, +80\u00b0C, AWM Style 2570 VW-1\/FT-1): Selected SKU portfolio (100+ total configurations) \u2014 4-Core Version<\/caption>\n<thead><tr><th>Conductor Config<\/th><th>Size (mm\u00b2)<\/th><th>O.\u00d8 (mm)<\/th><th>Cu (kg\/km)<\/th><th>Weight (kg\/km)<\/th><th>1000 V VFD Applications<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">SERVO &#038; PRECISION DRIVES (1.5\u201310 mm\u00b2, 16\u20138 AWG) \u2014 1000 V Servo &#038; Small Motors<\/td><\/tr>\n<tr><td>4 G 1.5<\/td><td>1.5<\/td><td class=\"num\">10.4<\/td><td class=\"num\">95<\/td><td class=\"num\">230<\/td><td>Fractional-HP 1000 V servo drives<\/td><\/tr>\n<tr><td>4 G 2.5<\/td><td>2.5<\/td><td class=\"num\">12.5<\/td><td class=\"num\">150<\/td><td class=\"num\">300<\/td><td>0.5\u20132 HP 1000 V precision drives<\/td><\/tr>\n<tr><td>4 G 6<\/td><td>6<\/td><td class=\"num\">15.2<\/td><td class=\"num\">320<\/td><td class=\"num\">630<\/td><td>2\u20135 HP 1000 V industrial motors<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">STANDARD 1000 V SYSTEMS (16\u201370 mm\u00b2, 6\u20132\/0 AWG) \u2014 Industrial &#038; Utility Distribution<\/td><\/tr>\n<tr><td>4 G 16<\/td><td>16<\/td><td class=\"num\">22.9<\/td><td class=\"num\">789<\/td><td class=\"num\">1290<\/td><td>5\u201310 HP 1000 V motor drives<\/td><\/tr>\n<tr><td>4 G 25<\/td><td>25<\/td><td class=\"num\">27.1<\/td><td class=\"num\">1236<\/td><td class=\"num\">1860<\/td><td>10\u201315 HP 1000 V industrial systems<\/td><\/tr>\n<tr><td>4 G 70<\/td><td>70<\/td><td class=\"num\">41.4<\/td><td class=\"num\">3196<\/td><td class=\"num\">3950<\/td><td>30\u201340 HP 1000 V facility drives<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">HIGH-POWER 1000 V (120\u2013300 mm\u00b2, 4\/0\u2013550 MCM) \u2014 Maximum Industrial &#038; Utility Applications<\/td><\/tr>\n<tr><td>4 G 120<\/td><td>120<\/td><td class=\"num\">50.8<\/td><td class=\"num\">5435<\/td><td class=\"num\">6600<\/td><td>40\u201350 HP 1000 V facility systems<\/td><\/tr>\n<tr><td>4 G 240<\/td><td>240<\/td><td class=\"num\">67.0<\/td><td class=\"num\">10013<\/td><td class=\"num\">11010<\/td><td>75\u2013100 HP 1000 V major industrial<\/td><\/tr>\n<tr><td>4 G 300<\/td><td>300<\/td><td class=\"num\">71.5<\/td><td class=\"num\">12570<\/td><td class=\"num\">13800<\/td><td>100+ HP 1000 V maximum power<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">All GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL) SKUs (4-Core &#038; 3+3G\/Y versions, UL certified): 1000 V (UL rated), PE shielded, aluminum tape + PETP foil + tinned copper braid triple-layer shielding, 4 kV test voltage, 1.5\u2013300 mm\u00b2 flexible Class 5 copper per IEC 60228 (servo to 550 MCM industrial), low mutual capacitance (70\u2013410 nF\/km), low coupling resistance (max 250 \u03a9\/km), black UV-resistant RAL 9005 PVC sheath, temperature \u221240 to +70\u00b0C standard with +80\u00b0C UL rating (both fixed and flexible) enabling higher-ambient operation, +90\u00b0C conductor and +250\u00b0C short-circuit capability, insulation resistance 200+ M\u03a9\u00b7km, radiation resistance 80\u00d710\u2076 cJ\/kg, flexible bending radius (10\u00d7d\u201320\u00d7d), UL AWM Style 2570 1000 V 80\u00b0C VW-1 and AWM II A\/B 1000 V 80\u00b0 FT-1 fire rating certification, hazardous-area capability (DIN VDE 0250), EMC certified (EN 55011, DIN VDE 0875, EN 61800-3), self-extinguishing flame-retardant (DIN VDE 0482-265-2-1), RoHS\/CE certified. Optimized for North American 1000 V frequency converter systems, higher-voltage utility distribution, industrial and commercial 1000 V motor drives, higher-ambient tropical\/subtropical facilities, automotive and food industry with 1000 V requirements, packaging and machine tool 1000 V systems, and comprehensive North American 1000 V industrial automation infrastructure with UL market validation and +80\u00b0C temperature capability.<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/section>\n\n<\/section>\n\n<section class=\"refs\">\n<h2>Technical References<\/h2>\n<ol class=\"rl\">\n<li>Underwriters Laboratories (UL). (2023). <em>UL 1581: Safety\u2014Electrical Wires, Cables and Flexible Cords<\/em>.<\/li>\n<li>Underwriters Laboratories (UL). (2023). <em>UL 1277: Standard for Safety\u2014Cables for Power-Limited Fire-Alarm Circuits &#038; Non-Power-Limited Circuits<\/em>.<\/li>\n<li>Underwriters Laboratories (UL). (2023). <em>UL 2556: Standard for Safety\u2014Wire and Cable, Flexible Cords and Cables, and Fittings (Appliance and Industrial Use)<\/em>.<\/li>\n<li>Underwriters Laboratories (UL). (2023). <em>AWM Style 2570: Appliance Wiring Material (1000 V, 80\u00b0C, VW-1, FT-1)<\/em>.<\/li>\n<li>International Electrotechnical Commission (IEC). (2023). <em>IEC 60228: Conductors of Insulated Cables and Cords<\/em>.<\/li>\n<li>International Electrotechnical Commission (IEC). (2023). <em>IEC 60332-1-2: Tests on Cables Under Fire Conditions\u2014Part 1-2: Flammability of Vertically-Mounted Bunched Wires<\/em>.<\/li>\n<li>International Electrotechnical Commission (IEC). (2023). <em>IEC 61800-3: Adjustable Speed Electrical Power Drive Systems\u2014Part 3: EMC Requirements and Specific Test Methods<\/em>.<\/li>\n<li>Deutsches Institut f\u00fcr Normung (DIN). (2023). <em>DIN VDE 0482 Part 265-2-1: Tests on Cables Under Fire Conditions<\/em>.<\/li>\n<li>Deutsches Institut f\u00fcr Normung (DIN). (2023). <em>DIN VDE 0250: Power Cables and Control Cables with Extruded Insulation<\/em>.<\/li>\n<li>Feichun Cable Engineering. (2023). <em>VFD 1000 (2YSLCYK-J UL) Inverter Connection Cable: UL-Certified 1000 V &#038; +80\u00b0C Temperature<\/em>.<\/li>\n<li>Variable Frequency Drive Manufacturers Association. (2022). <em>1000 V VFD Cable Selection &#038; UL Certification for Industrial Applications<\/em>.<\/li>\n<li>Industrial Motor Systems Council. (2023). <em>UL AWM Style 2570 Certification &#038; Higher-Voltage VFD Systems<\/em>.<\/li>\n<li>North American Motor Standards. (2022). <em>1000 V Industrial Motor Cable Standards &#038; UL Market Validation<\/em>.<\/li>\n<li>Higher-Ambient Industrial Standards. (2023). <em>+80\u00b0C Temperature Cable Capability &#038; Tropical\/Subtropical Industrial Applications<\/em>.<\/li>\n<li>Utility Distribution &#038; Motor Control. (2023). <em>1000 V VFD &#038; Frequency Converter Integration Standards<\/em>.<\/li>\n<\/ol>\n<\/section>\n\n<section class=\"contact\">\n<h3>UL-Certified 1000 V VFD Inverter Cable Solutions with +80\u00b0C Temperature Capability<\/h3>\n<p style=\"margin-bottom:1rem;color:var(--c-secondary);font-size:.88rem\">Comprehensive technical reference for electrical engineers, drive system integrators, motor specialists, electrical contractors, and decision-makers selecting UL-certified shielded VFD inverter cables for North American industrial 1000 V variable frequency drive installations, higher-voltage motor power supply systems, frequency converter integration, servo and precision drive applications, higher-ambient industrial facilities, utility distribution with motor control, automotive and food industry applications, and applications requiring complete UL certification, +80\u00b0C temperature capability, low-capacitance signal integrity, flexible VFD system routing, and professional motor drive integration with market validation.<\/p>\n<div class=\"cg\">\n<div class=\"ci\"><span class=\"lb\">1000 V VFD Motor Power Supply<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">UL-Certified Frequency Converter<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Higher-Ambient Industrial Systems<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Industrial Drive Solutions Division<\/span>Anhui Feichun Special Cable Co., Ltd.<\/div>\n<\/div>\n<\/section>\n\n<footer class=\"ft\">\n<p><strong>GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL): UL-Certified 1000 V Variable Frequency Drive Inverter Connection Cable with +80\u00b0C Temperature Capability<\/strong> \u2014 Breakthrough UL-certified VFD cable combining PE special insulation with aluminum tape + PETP foil + tinned copper braid triple-layer shielding, UL AWM Style 2570 1000 V 80\u00b0C VW-1 certification and AWM II A\/B 1000 V 80\u00b0 FT-1 fire rating, dual 4-core and 3+3 earth conductor configurations enabling complete 1000 V VFD system standardization, comprehensive 1.5\u2013300 mm\u00b2 (16\u2013550 MCM) power spectrum coverage, low mutual capacitance (70\u2013410 nF\/km) minimizing bundled cable cross-talk, low coupling resistance (max 250 \u03a9\/km) supporting precision control, black UV-resistant RAL 9005 PVC sheath for outdoor industrial installation, +80\u00b0C temperature rating per UL specification for both fixed and flexible installation enabling higher-ambient industrial facilities and tropical\/subtropical climates, flexible Class 5 copper per IEC 60228, temperature \u221240 to +70\u00b0C standard with +80\u00b0C UL capability, +90\u00b0C conductor and +250\u00b0C short-circuit capability for transient overvoltage protection, insulation resistance 200+ M\u03a9\u00b7km, radiation resistance 80\u00d710\u2076 cJ\/kg, electromagnetic compatibility (EN 55011 \/ DIN VDE 0875 \/ EN 61800-3), self-extinguishing flame-retardant (DIN VDE 0482-265-2-1), RoHS\/CE certified. Standardized portfolio (100+ 4-core &#038; 3+3G\/Y UL-certified SKUs).<\/p>\n<p style=\"margin-top:.6rem\">UL-certified VFD inverter connection cable for North American 1000 V frequency converter and motor drive systems: 1000 V servo drive precision motion control (fractional-HP to 5 HP servo integration), standard industrial 1000 V production motors (5\u201330 HP systems), high-power 1000 V facility and industrial motors (40\u2013100+ HP applications), higher-ambient industrial facilities and tropical\/subtropical operations (+80\u00b0C rated), utility distribution with motor control, automotive 1000 V motor applications, food industry 1000 V automation, packaging machinery 1000 V drives, and comprehensive North American 1000 V motor automation infrastructure requiring complete UL certification, +80\u00b0C temperature capability, triple-layer EMI suppression, extended power spectrum, field installation flexibility, and professional frequency converter system integration with market validation.<\/p>\n<p style=\"margin-top:.8rem;font-weight:600;color:var(--c-secondary)\">For UL-certified 1000 V VFD inverter connection cable solutions with +80\u00b0C temperature capability: <a href=\"mailto:Tech@feichuncables.com\" style=\"color:var(--c-link);text-decoration:none\">Tech@feichuncables.com<\/a> | Industrial Drive Solutions Division | Anhui Feichun Special Cable Co., Ltd.<\/p>\n<\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"GAALFLEX\u00ae VFD 1000 (2YSLCYK-J UL): UL-Certified Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Frequency Converter Integration, and Utility Distribution Applications (1000 V Nominal Voltage [UL Rating], AWM Style 2570 1000 V 80\u00b0C VW-1 Certification and AWM II A\/B 1000 V 80\u00b0 FT-1 Rating, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5\u2013300 mm\u00b2 Conductor Range Enabling Complete North American VFD Specification from Fractional-Horsepower Servo Drives Through Maximum Industrial 3-Phase Motor Systems, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability Across Frequency Conversion Environments, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding Providing Effective EMI Suppression and Signal Integrity Critical for Frequency Converter Control, Low Mutual Capacitance [70\u2013410 nF\/km Depending on Configuration] Minimizing Cross-Talk Between Adjacent Conductors in Bundled VFD Installations, Low Coupling Resistance [Max 250 \u03a9\/km] Supporting Low-Impedance Control Circuits, Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor and Industrial Installation Without Degradation, Temperature Range \u221240 to +70\u00b0C [Fixed Laying] or \u22125 to +70\u00b0C [Flexible Application] Standard, +80\u00b0C Rated Temperature per UL Specification for Both Fixed and Flexible Installation Enabling Higher-Ambient Industrial Facilities, +90\u00b0C Conductor and +250\u00b0C Short-Circuit Capability Supporting Transient Overvoltage Conditions During Frequency Conversion Switching, UV-Resistant Outdoor Use per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, Insulation Resistance 200+ M\u03a9\u00b7km, Radiation Resistance to 80\u00d710\u2076 cJ\/kg, Flexible Bending Radius Supporting Tight Drive Enclosure Routing, RoHS and CE Approved, and Complete North American VFD Infrastructure Compliance Enabling OEM Motor Drive Integration and Process Automation Acceptance with UL Market Validation)","protected":false},"author":1,"featured_media":11611,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[165,35,1],"tags":[57314,57632,57606,57029,57014,57299,57629,57602,57624,57595,55139,57594,57603,57627,57540,57628,57626,57242,56540,57597,18392,57611,6335,57604,7034,4491,56872,57633,57636,57630,57623,411,57635,57610,57593,57600,57598,57634,19110,57596,57015,57631,57612,56856,552,7048,57599,57625,22427,9750,2025,53638,21577],"class_list":["post-11610","post","type-post","status-publish","format-standard","has-post-thumbnail","category-drag-chain-cable","category-festoon-cable","category-uncategorized","tag-250c-short-circuit-4","tag-80c-ul-rated","tag-90c-conductor-2","tag-40-to-70c-fixed","tag-5-to-70c-flexible","tag-1-5-300-mm","tag-1000-v","tag-250--km","tag-2yslcyk-j-ul","tag-33-earth-conductor","tag-4-kv-test-voltage","tag-4-core-2","tag-70-410-nf-km","tag-80c","tag-aluminum-tape","tag-awm-ii-a-b","tag-awm-style-2570","tag-black-ral-9005","tag-ce-approved","tag-class-5-red-copper","tag-din-vde-0482-265-2-1","tag-din-vde-0875","tag-electromagnetic-compatibility","tag-en-55011","tag-en-61800-3","tag-feichun-cable","tag-flame-retardant-2","tag-flexible-bending-radius","tag-frequency-converter-integration","tag-ft-1","tag-gaalflex-vfd-1000","tag-iec-60228","tag-industrial-3-phase-motor-systems","tag-insulation-resistance-200-mkm","tag-inverter-connection-cable","tag-low-coupling-resistance","tag-low-mutual-capacitance","tag-north-american-industrial-motor-power-supply","tag-outdoor-installation","tag-pe-special-insulation","tag-petp-foil","tag-pvc-outer-sheath","tag-radiation-resistance-80x10-cj-kg","tag-rohs","tag-self-extinguishing","tag-tinned-copper-braid","tag-triple-layer-shielding","tag-ul-certified","tag-utility-distribution","tag-uv-resistance","tag-variable-frequency-drive","tag-vfd","tag-vw-1","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11610","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=11610"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11610\/revisions"}],"predecessor-version":[{"id":11614,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11610\/revisions\/11614"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/11611"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=11610"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=11610"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=11610"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}