{"id":11606,"date":"2026-05-08T15:51:10","date_gmt":"2026-05-08T07:51:10","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=11606"},"modified":"2026-05-08T15:51:39","modified_gmt":"2026-05-08T07:51:39","slug":"type-2yslcyk-j-gaalflex-vfd","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/type-2yslcyk-j-gaalflex-vfd\/","title":{"rendered":"Type 2YSLCYK-J GAALFLEX\u00ae VFD"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">acc. to CPR UE 305\/11, EN 50575:2014 + A1:2016, Eca<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"d9d8d8\" data-has-transparency=\"false\" style=\"--dominant-color: #d9d8d8;\" loading=\"lazy\" decoding=\"async\" width=\"984\" height=\"626\" sizes=\"auto, (max-width: 984px) 100vw, 984px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1383.avif\" alt=\"\" class=\"wp-image-11607 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1383.avif 984w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1383-300x191.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1383-768x489.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1383-400x254.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1383-800x509.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1383-832x529.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>GAALFLEX\u00ae VFD 2YSLCYK-J: CPR-Compliant Variable Frequency Drive Inverter Connection Cable, 0.6\/1 kV, Eca Classification (EN 50575:2014), Mining &#038; Outdoor UV-Resistant, Shielded PE Insulation, Aluminum Tape + PETP + Tinned Copper Braid, Dual Configuration (4-Core &#038; 3+3G\/Y), 1.5\u2013300 mm\u00b2 (16\u2013550 MCM), Low Mutual Capacitance, Black PVC Sheath, EMC Compatible | CPR-Compliant Mining VFD Cable<\/title>\n<meta name=\"description\" content=\"GAALFLEX\u00ae VFD 2YSLCYK-J: CPR-compliant (EU 305\/2011 + EN 50575:2014+A1:2016, Eca classification) variable frequency drive inverter connection cable engineered for North American industrial motor power supply, mining applications, and outdoor frequency converter systems featuring 0.6\/1 kV nominal voltage, 4 kV test voltage, comprehensive dual-configuration portfolio (4-core and 3+3 earth conductor versions), 1.5\u2013300 mm\u00b2 conductor range enabling complete VFD specification from servo drives through industrial motors, flexible Class 5 red copper per IEC 60228, PE special insulation compound providing electrical stability, aluminum tape + PETP foil + tinned copper braid triple-layer shielding, low mutual capacitance (70\u2013410 nF\/km) minimizing cross-talk, low coupling resistance (max 250 \u03a9\/km), black RAL 9005 PVC outer sheath with UV resistance enabling outdoor mining and industrial installation without degradation, temperature range \u221240 to +70\u00b0C (fixed) or \u22125 to +70\u00b0C (flexible application) with +90\u00b0C conductor and +250\u00b0C short-circuit capability, hazardous-area installation per DIN VDE 0250, electromagnetic compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, self-extinguishing and flame-retardant per DIN VDE 0482-265-2-1 \/ EN 50265-2-1 \/ IEC 60332-1-2, insulation resistance 200+ M\u03a9\u00b7km, radiation resistance to 80\u00d710\u2076 cJ\/kg, CPR fire classification Eca (EN 13501-1) enabling European regulatory compliance, optional XLPE halogen-free version (2XSLCHK-J) per IEC 60502-4 with Eca-rated black SHF1 sheath, suitable for mining machinery, outdoor industrial systems, automotive and food automation with environmental exposure, and complete international VFD infrastructure compliance with regulatory mandates.\" \/>\n<meta name=\"keywords\" content=\"CPR cable,mining cable,VFD cable,EN 50575,Eca classification,UV resistant,outdoor\" \/>\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<meta name=\"robots\" content=\"index,follow,max-image-preview:large,max-snippet:-1\" \/>\n<meta property=\"og:title\" content=\"GAALFLEX\u00ae VFD 2YSLCYK-J: CPR-Compliant Mining &#038; Outdoor VFD Cable\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta name=\"article:published_time\" content=\"2026-05-08T00:00:00Z\" \/>\n<meta name=\"article:author\" content=\"Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.feichuncables.com\/industrial-motors\/gaalflex-vfd-2yslcyk-j-cpr-mining-outdoor-inverter\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\" \/>\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin \/>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\" \/>\n<style>\n:root{\n  --bg-body:#F7F5F1; --bg-surface:#FFFFFF; --bg-recessed:#F0E8E0; --bg-th:#5A4A4A; --bg-tr-alt:#F9F8F5;\n  --bg-callout-cpr:#E0E0F5; --bg-callout-mining:#E8F0E0; --bg-callout-uv:#F5E8E0; --bg-callout-emi:#E0F5E8;\n  --bg-callout-shield:#E8E0F5; --bg-callout-outdoor:#E8F0E0;\n  --c-body:#1B1F1D; --c-secondary:#454D4A; --c-tertiary:#727A76; --c-inverse:#FFFFFF;\n  --c-link:#2A5A8A; --c-cpr:#1A2A8A; --c-mining:#4A6A2A; --c-uv:#8A5A2A;\n  --c-emi:#2A8A6A; --c-shield:#5A3A8A; --c-outdoor:#6A8A2A;\n  --b-rule:#D4D0C8; --b-light:#E8E5DE; --b-accent:#2A5A8A; --b-table:#C4C0BA;\n  --sh-sm:0 1px 2px rgba(0,0,0,0.06); --sh-md:0 3px 12px rgba(0,0,0,0.08);\n  --badge-bg:#5A4A4A; --badge-c:#FFFFFF; --badge-cpr:#1A2A8A; --badge-mining:#4A6A2A;\n}\n@media(prefers-color-scheme:dark){\n  :root{\n    --bg-body:#0B0F0D; --bg-surface:#161A18; --bg-recessed:#0F1A10; --bg-th:#5A4A4A; --bg-tr-alt:#0F1211;\n    --bg-callout-cpr:#0A0A40; --bg-callout-mining:#0A2A10; --bg-callout-uv:#2A1A10; --bg-callout-emi:#0A2A20;\n    --bg-callout-shield:#1A0A40; --bg-callout-outdoor:#0A2A10;\n    --c-body:#E2E5E2; --c-secondary:#B3BAB6; --c-tertiary:#858D8A; --c-inverse:#0B0F0D;\n    --c-link:#6A98C8; --c-cpr:#6A88E8; --c-mining:#88B860; --c-uv:#E8A880;\n    --c-emi:#6AC898; --c-shield:#D880E8; --c-outdoor:#B8D880;\n    --b-rule:#252D2A; --b-light:#1D2421; --b-accent:#6A98C8; --b-table:#232B28;\n  }\n}\n*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}\nhtml{font-size:16px;scroll-behavior:smooth}\nbody{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden;}\n.page-wrap{max-width:920px;margin:0 auto;padding:2.5rem 1.25rem 4rem}\n.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--c-link);position:relative;}\n.hdr::after{content:\"\";position:absolute;left:0;bottom:-2px;width:400px;height:2px;background:linear-gradient(90deg,#1A2A8A 0%,#4A6A2A 50%,#8A5A2A 100%);}\n.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem;}\n.hdr .badge.cpr{background:var(--badge-cpr)} .hdr .badge.mining{background:var(--badge-mining)}\n.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.4rem,3.3vw,2.05rem);line-height:1.24;margin-bottom:.7rem;letter-spacing:-.005em;color:var(--c-link);}\n.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.65;margin-bottom:.4rem;}\n.hdr .sub-en{font-size:.82rem;color:var(--c-tertiary);line-height:1.55;font-style:italic;margin-top:.5rem;padding-top:.5rem;border-top:1px solid var(--b-light);}\n.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary);}\n.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm);}\n.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-link);margin-bottom:.55rem;}\n.toc ol{list-style:none;counter-reset:tc;padding:0;columns:2;column-gap:1.5rem}\n.toc li{counter-increment:tc;margin-bottom:.28rem;break-inside:avoid}\n.toc li::before{content:counter(tc,decimal-leading-zero) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-mining);}\n.toc a{font-size:.82rem;color:var(--c-secondary);text-decoration:none;line-height:1.4;}\n.toc a:hover{color:var(--c-link);text-decoration:underline}\n@media(max-width:640px){.toc ol{columns:1}}\n.body h2{font-family:'Source Serif 4',Georgia,serif;font-weight:700;font-size:1.38rem;margin:3rem 0 .9rem;padding-bottom:.4rem;border-bottom:1px solid var(--b-light);color:var(--c-link);line-height:1.3;}\n.body h3{font-weight:600;font-size:1.06rem;margin:1.9rem 0 .55rem;color:var(--c-body);}\n.body h4{font-weight:600;font-size:.94rem;margin:1.3rem 0 .45rem;color:var(--c-link);letter-spacing:.01em;}\n.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify;hyphens:auto;}\n.body strong{font-weight:600;color:var(--c-body)}\n.cpr-em{color:var(--c-cpr);font-weight:600} .mining-em{color:var(--c-mining);font-weight:600} .uv-em{color:var(--c-uv);font-weight:600}\n.emi-em{color:var(--c-emi);font-weight:600} .shield-em{color:var(--c-shield);font-weight:600} .outdoor-em{color:var(--c-outdoor);font-weight:600}\n.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-sm);}\n.tw table{width:100%;border-collapse:collapse;font-size:.83rem;line-height:1.45;min-width:720px;}\n.tw caption{text-align:left;font-weight:600;font-size:.76rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light);}\n.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.72rem;padding:.55rem .7rem;text-align:left;border-bottom:2px solid var(--c-link);}\n.tw tbody td{padding:.5rem .7rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top;}\n.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)} .tw tbody tr:hover{background:var(--bg-callout-cpr)}\n.tw tbody td:first-child{font-weight:500;color:var(--c-body)}\n.tw tbody td code{font-family:'IBM Plex Mono',monospace;font-size:.78rem;background:var(--bg-recessed);padding:.08em .35em;border-radius:3px;}\n.tw tbody td.num{font-family:'IBM Plex Mono',monospace;font-size:.79rem;text-align:right;}\n.tw tbody td.winner{background:var(--bg-callout-mining);color:var(--c-body);font-weight:600;}\n.note{padding:1rem 1.25rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent);}\n.note.cpr{background:var(--bg-callout-cpr);border-left-color:var(--c-cpr)}\n.note.mining{background:var(--bg-callout-mining);border-left-color:var(--c-mining)}\n.note.uv{background:var(--bg-callout-uv);border-left-color:var(--c-uv)}\n.note.emi{background:var(--bg-callout-emi);border-left-color:var(--c-emi)}\n.note.shield{background:var(--bg-callout-shield);border-left-color:var(--c-shield)}\n.note.outdoor{background:var(--bg-callout-outdoor);border-left-color:var(--c-outdoor)}\n.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.35rem;}\n.note p{margin-bottom:.35rem}\n.formula{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1rem 1.2rem;margin:1.2rem 0;font-family:'IBM Plex Mono',monospace;font-size:.85rem;color:var(--c-body);overflow-x:auto;line-height:1.9;}\n.formula .fnote{display:block;font-family:'Instrument Sans',sans-serif;font-size:.78rem;color:var(--c-tertiary);font-style:italic;margin-top:.55rem;}\n.formula .ftit{display:block;font-family:'Instrument Sans',sans-serif;font-weight:600;font-size:.78rem;color:var(--c-link);margin-bottom:.5rem;letter-spacing:.04em;text-transform:uppercase;}\n.spec-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(190px,1fr));gap:1rem;margin:1.5rem 0;}\n.spec-card{background:var(--bg-surface);border:1px solid var(--b-rule);border-top:3px solid var(--c-link);border-radius:4px;padding:1rem 1.1rem;}\n.spec-card.cpr{border-top-color:var(--c-cpr)}\n.spec-card.mining{border-top-color:var(--c-mining)}\n.spec-card.uv{border-top-color:var(--c-uv)}\n.spec-card.emi{border-top-color:var(--c-emi)}\n.spec-card.shield{border-top-color:var(--c-shield)}\n.spec-card.outdoor{border-top-color:var(--c-outdoor)}\n.spec-card .lab{font-size:.68rem;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.4rem;}\n.spec-card .val{font-family:'IBM Plex Mono',monospace;font-size:1.08rem;font-weight:600;color:var(--c-body);line-height:1.3;margin-bottom:.3rem;}\n.spec-card .des{font-size:.78rem;color:var(--c-secondary);line-height:1.45;}\n.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--c-link);}\n.refs h2{font-size:1.08rem;margin-bottom:.9rem}\n.rl{list-style:none;counter-reset:rf;padding:0}\n.rl li{counter-increment:rf;font-size:.79rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5;}\n.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.74rem;}\n.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-left:4px solid var(--c-link);border-radius:4px;padding:1.5rem;margin-top:2.5rem;}\n.contact h3{font-size:.98rem;margin-bottom:.7rem}\n.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem;}\n.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}\n.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem;}\n.ci a{color:var(--c-link);text-decoration:none} .ci a:hover{text-decoration:underline}\n.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55;}\n@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.28rem}.tw{font-size:.76rem}.cg{grid-template-columns:1fr}}\n<\/style>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechnicalArticle\",\"headline\":\"GAALFLEX\u00ae VFD 2YSLCYK-J: CPR-Compliant Mining & Outdoor VFD Inverter Cable\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\",\"url\":\"https:\/\/www.feichuncables.com\"},\"datePublished\":\"2026-05-08\",\"proficiencyLevel\":\"Advanced\",\"keywords\":\"CPR cable,mining cable,VFD cable,EN 50575,Eca,UV resistant\"}<\/script>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n<header class=\"hdr\">\n<span class=\"badge cpr\">CPR &#038; Eca Compliant \u00b7 EU 305\/2011 + EN 50575<\/span>\n<span class=\"badge mining\">GAALFLEX\u00ae VFD 2YSLCYK-J \u00b7 Mining &#038; Outdoor UV-Resistant<\/span>\n<span class=\"badge cpr\">4-Core &#038; 3+3G\/Y \u00b7 0.6\/1 kV \u00b7 Black Sheath \u00b7 Hazardous Area<\/span>\n\n<h1>GAALFLEX\u00ae VFD 2YSLCYK-J: CPR-Compliant (EU 305\/2011 + EN 50575:2014+A1:2016, Eca Classification) Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Mining Applications, and Outdoor Frequency Converter Systems (0.6\/1 kV Nominal Voltage, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5\u2013300 mm\u00b2 Conductor Range Enabling Complete VFD Specification from Servo Drives Through Industrial Motors, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70\u2013410 nF\/km], Low Coupling Resistance [Max 250 \u03a9\/km], Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor Mining and Industrial Installation Without Degradation, Temperature Range \u221240 to +70\u00b0C [Fixed] or \u22125 to +70\u00b0C [Flexible Application] with +90\u00b0C Conductor and +250\u00b0C Short-Circuit Capability, Hazardous-Area Installation per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, CPR Fire Classification Eca [EN 13501-1] Enabling European Regulatory Compliance, Optional XLPE Halogen-Free Version [2XSLCHK-J] per IEC 60502-4 with Eca-Rated Black SHF1 Sheath, Suitable for Mining Machinery, Outdoor Industrial Systems, Automotive and Food Automation with Environmental Exposure, and Complete International VFD Infrastructure Compliance with Regulatory Mandates)<\/h1>\n\n<p class=\"hdr .sub\"><span class=\"cpr-em\">CPR-compliant VFD cable combining PE shielded insulation with triple-layer screening, EU 305\/2011 + EN 50575 Eca certification, mining-rated design, UV-resistant black outdoor sheath, dual 4-core and 3+3G\/Y configurations, low capacitance, low coupling resistance, hazardous-area capability, and professional drive system integration<\/span>\u2014addressing frequency converter signal integrity, mining equipment reliability, outdoor environmental durability, regulatory compliance, and industrial automation infrastructure simultaneously.<\/p>\n\n<p class=\"hdr .sub-en\">Advanced technical reference for electrical engineers, drive system integrators, mining equipment specialists, motor specialists, electrical contractors, and decision-makers selecting CPR-compliant shielded VFD inverter cables for North American industrial variable frequency drive installations with mining applications, outdoor frequency converter integration, motor power supply systems, hazardous-area motor control, automotive and food industry applications, and applications requiring complete EU regulatory compliance, environmental durability, low-capacitance signal integrity, mining equipment safety, and professional frequency converter system integration.<\/p>\n\n<div class=\"meta\">\n<span>Anhui Feichun Special Cable Co., Ltd. Industrial Drive Solutions Division<\/span>\n<span>Published May 8, 2026<\/span>\n<span>Advanced technical analysis ~138 minutes with 80+ specification tables<\/span>\n<span>CPR-Compliant VFD Cable \u00b7 Mining &#038; Outdoor \u00b7 0.6\/1 kV \u00b7 EU Eca \u00b7 Hazardous Area<\/span>\n<\/div>\n<\/header>\n\n<div class=\"spec-grid\">\n  <div class=\"spec-card\"><div class=\"lab\">Voltage Rating<\/div><div class=\"val\">0.6\/1 kV<\/div><div class=\"des\">Frequency converter rated<\/div><\/div>\n  <div class=\"spec-card cpr\"><div class=\"lab\">CPR Compliance<\/div><div class=\"val\">EU 305\/2011 + EN 50575 (Eca)<\/div><div class=\"des\">European fire classification<\/div><\/div>\n  <div class=\"spec-card mining\"><div class=\"lab\">Mining Application<\/div><div class=\"val\">Yes (DIN VDE 0250)<\/div><div class=\"des\">Mining equipment certified<\/div><\/div>\n  <div class=\"spec-card uv\"><div class=\"lab\">UV Resistance<\/div><div class=\"val\">Outdoor-Rated Compound<\/div><div class=\"des\">Outdoor mining durability<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Conductor Range<\/div><div class=\"val\">1.5\u2013300 mm\u00b2 (16\u2013550 MCM)<\/div><div class=\"des\">Complete power spectrum<\/div><\/div>\n  <div class=\"spec-card shield\"><div class=\"lab\">Shielding<\/div><div class=\"val\">Al Tape + PETP + Cu Braid<\/div><div class=\"des\">Triple-layer EMI suppression<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Configuration<\/div><div class=\"val\">4-Core &#038; 3+3G\/Y<\/div><div class=\"des\">Dual system coverage<\/div><\/div>\n  <div class=\"spec-card outdoor\"><div class=\"lab\">Outer Sheath<\/div><div class=\"val\">Black (RAL 9005) UV-Resistant<\/div><div class=\"des\">Mining environmental protection<\/div><\/div>\n  <div class=\"spec-card emi\"><div class=\"lab\">EMC Compliance<\/div><div class=\"val\">EN 55011 \/ EN 61800-3<\/div><div class=\"des\">Frequency converter safe<\/div><\/div>\n  <div class=\"spec-card\"><div class=\"lab\">Hazardous Area<\/div><div class=\"val\">DIN VDE 0250<\/div><div class=\"des\">Mining installation rated<\/div><\/div>\n<\/div>\n\n<nav class=\"toc\">\n<div class=\"toc-label\">Contents \u2014 10 Advanced Sections<\/div>\n<ol>\n<li><a href=\"#s1\">CPR Compliance &#038; Eca Fire Classification: EU 305\/2011 + EN 50575 Regulatory Mandate<\/a><\/li>\n<li><a href=\"#s2\">Mining Application Suitability: DIN VDE 0250 &#038; Hazardous-Area Certification<\/a><\/li>\n<li><a href=\"#s3\">UV-Resistant Outdoor Black Sheath: Mining Equipment Environmental Durability<\/a><\/li>\n<li><a href=\"#s4\">Triple-Layer Shielding with Low Capacitance: Mining VFD Signal Integrity<\/a><\/li>\n<li><a href=\"#s5\">Dual Configuration Coverage: 4-Core &#038; 3+3 Earth Conductor Mining Systems<\/a><\/li>\n<li><a href=\"#s6\">Extended 1.5\u2013300 mm\u00b2 Range: Complete Mining VFD Power Spectrum<\/a><\/li>\n<li><a href=\"#s7\">EMC Compliance for Mining Environments: EN 61800-3 &#038; Industrial Noise<\/a><\/li>\n<li><a href=\"#s8\">Halogen-Free Optional Version: Environmental &#038; Regulatory Compliance<\/a><\/li>\n<li><a href=\"#s9\">Comparative Analysis: CPR 2YSLCYK-J vs. Standard VFD &#038; Non-Regulated Alternatives<\/a><\/li>\n<li><a href=\"#s10\">Complete GAALFLEX\u00ae VFD 2YSLCYK-J CPR-Compliant SKU Catalog (100+ Mining Configurations)<\/a><\/li>\n<\/ol>\n<\/nav>\n\n<section class=\"body\">\n\n<section id=\"s1\">\n<h2>1. CPR Compliance &#038; Eca Fire Classification: EU 305\/2011 + EN 50575 Regulatory Mandate<\/h2>\n<p><span class=\"cpr-em\">GAALFLEX\u00ae VFD 2YSLCYK-J complies with EU Construction Products Regulation (CPR) 305\/2011 and EN 50575:2014+A1:2016, achieving Eca fire classification (CEI UNEL 35016 \/ EN 13501-1) enabling European and international regulatory acceptance<\/span>.<\/p>\n<div class=\"note cpr\">\n<div class=\"nt\">CPR Compliance: EU Regulatory Mandate &#038; Market Access for Mining Equipment<\/div>\n<p><strong>Mining equipment regulatory scenario:<\/strong> An Australian mining equipment OEM supplies conveyor belt motors and ventilation drives to European mining operations. Local EU regulations (CPR 305\/2011) mandate Eca-classified cables for industrial equipment sold into member states. Traditional unregulated VFD cable: rejected by EU procurement, requires costly substitution. GAALFLEX VFD 2YSLCYK-J CPR Eca-certified: meets all EU regulatory requirements, passes third-party fire testing, certificates provided per EN 50575. Result: equipment accepted in 27 EU member states, customer eliminates regulatory delay, mining operations across Europe fully compliant, OEM market access restored.<\/p>\n<\/div>\n<\/section>\n\n<section id=\"s2\">\n<h2>2. Mining Application Suitability: DIN VDE 0250 &#038; Hazardous-Area Certification<\/h2>\n<p><span class=\"mining-em\">GAALFLEX\u00ae VFD 2YSLCYK-J is specifically suitable for mining applications per DIN VDE 0250 with hazardous-area installation capability enabling underground and surface mining motor control systems<\/span>.<\/p>\n<\/section>\n\n<section id=\"s3\">\n<h2>3. UV-Resistant Outdoor Black Sheath: Mining Equipment Environmental Durability<\/h2>\n<p><span class=\"uv-em\">GAALFLEX\u00ae VFD 2YSLCYK-J features UV-resistant black RAL 9005 PVC outer sheath enabling outdoor mining installation, equipment exposed areas, and environmental protection without coating or conduit<\/span>.<\/p>\n<\/section>\n\n<section id=\"s4\">\n<h2>4. Triple-Layer Shielding with Low Capacitance: Mining VFD Signal Integrity<\/h2>\n<p><span class=\"shield-em\">GAALFLEX\u00ae VFD 2YSLCYK-J provides aluminum tape + PETP foil + tinned copper braid triple-layer shielding with low mutual capacitance (70\u2013410 nF\/km) ensuring precision frequency converter signal integrity in mining environments<\/span>.<\/p>\n<\/section>\n\n<section id=\"s5\">\n<h2>5. Dual Configuration Coverage: 4-Core &#038; 3+3 Earth Conductor Mining Systems<\/h2>\n<p><span class=\"mining-em\">GAALFLEX\u00ae VFD 2YSLCYK-J provides dual configuration portfolio (4-core single sheath and 3+3 earth conductor) enabling standardized mining VFD system specification across diverse underground and surface applications<\/span>.<\/p>\n<\/section>\n\n<section id=\"s6\">\n<h2>6. Extended 1.5\u2013300 mm\u00b2 Range: Complete Mining VFD Power Spectrum<\/h2>\n<p><span class=\"mining-em\">GAALFLEX\u00ae VFD 2YSLCYK-J spans 1.5\u2013300 mm\u00b2 (16\u2013550 MCM) enabling complete mining frequency converter specification from small hoist controls through maximum-power mining mill drives and ventilation systems<\/span>.<\/p>\n<\/section>\n\n<section id=\"s7\">\n<h2>7. EMC Compliance for Mining Environments: EN 61800-3 &#038; Industrial Noise<\/h2>\n<p><span class=\"emi-em\">GAALFLEX\u00ae VFD 2YSLCYK-J provides electromagnetic compatibility per EN 55011 (Industrial Emissions), EN 61800-3 (Drive Systems EMC), and DIN VDE 0875 enabling integration with mining VFD systems in high-noise underground and surface environments<\/span>.<\/p>\n<\/section>\n\n<section id=\"s8\">\n<h2>8. Halogen-Free Optional Version: Environmental &#038; Regulatory Compliance<\/h2>\n<p><span class=\"outdoor-em\">GAALFLEX\u00ae VFD 2YSLCYK-J offers optional 2XSLCHK-J halogen-free version with XLPE per IEC 60502-4 and SHF1 black Eca-rated sheath enabling environmental compliance and zero-halogen mining operations<\/span>.<\/p>\n<\/section>\n\n<section id=\"s9\">\n<h2>9. Comparative Analysis: CPR 2YSLCYK-J vs. Standard VFD &#038; Non-Regulated Alternatives<\/h2>\n\n<div class=\"tw\">\n<table>\n<caption>Table 9.1-A \u2014 Performance comparison: GAALFLEX VFD 2YSLCYK-J (CPR Eca mining-rated) vs. standard non-CPR VFD, unregulated alternatives<\/caption>\n<thead><tr><th>Metric<\/th><th>Non-CPR Standard VFD<\/th><th>Unregulated Mining Cable<\/th><th>Non-Mining Shielded<\/th><th>GAALFLEX 2YSLCYK-J (CPR Eca)<\/th><th>Advantage<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">REGULATORY COMPLIANCE &amp; MARKET ACCESS<\/td><\/tr>\n<tr><td>EU CPR 305\/2011 compliance<\/td><td class=\"num\">Limited (non-certified)<\/td><td class=\"num\">None (non-compliant)<\/td><td class=\"num\">Limited (if any)<\/td><td class=\"winner\">Full (Eca certified)<\/td><td>EU market access guaranteed<\/td><\/tr>\n<tr><td>Eca fire classification (EN 13501-1)<\/td><td class=\"num\">None (non-rated)<\/td><td class=\"num\">None (non-rated)<\/td><td class=\"num\">Unknown (non-cert)<\/td><td class=\"winner\">Yes (Eca tested certified)<\/td><td>27 EU member state compliance<\/td><\/tr>\n<tr><td>Mining application suitability (DIN VDE 0250)<\/td><td class=\"num\">Limited (if certified)<\/td><td class=\"num\">Limited (if any)<\/td><td class=\"num\">None (non-mining)<\/td><td class=\"winner\">Yes (mining certified)<\/td><td>Underground mining safe<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">OUTDOOR &amp; ENVIRONMENTAL DURABILITY<\/td><\/tr>\n<tr><td>UV-resistant outdoor black sheath<\/td><td class=\"num\">Limited (if available)<\/td><td class=\"num\">Limited (non-UV)<\/td><td class=\"num\">Limited (transparent)<\/td><td class=\"winner\">Yes (black UV-rated)<\/td><td>Mining outdoor deployment<\/td><\/tr>\n<tr><td>Outdoor mining equipment exposure<\/td><td class=\"num\">Limited (enclosure required)<\/td><td class=\"num\">Limited (weather degrades)<\/td><td class=\"num\">Poor (transparent fails)<\/td><td class=\"winner\">Excellent (no coating needed)<\/td><td>Exposed mining installation safe<\/td><\/tr>\n<tr><td colspan=\"5\" style=\"background:#E8E8E0;font-weight:600;text-align:center;\">MINING SYSTEM INTEGRATION<\/td><\/tr>\n<tr><td>Mining VFD triple-shielding + low-cap<\/td><td class=\"num\">Single shield (75\u201380 dB)<\/td><td class=\"num\">Limited (if shielded)<\/td><td class=\"num\">Single shield (poor for mining)<\/td><td class=\"winner\">Triple-layer (90+ dB) + low-cap<\/td><td>Mining noise immunity<\/td><\/tr>\n<tr><td>Hazardous-area installation (DIN VDE 0250)<\/td><td class=\"num\">Limited (if any)<\/td><td class=\"num\">Limited (non-certified)<\/td><td class=\"num\">None (non-compliant)<\/td><td class=\"winner\">Yes (mining hazard-rated)<\/td><td>Underground coal\/methane safe<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/section>\n\n<section id=\"s10\">\n<h2>10. Complete GAALFLEX\u00ae VFD 2YSLCYK-J CPR-Compliant SKU Catalog (100+ Mining Configurations)<\/h2>\n\n<p>GAALFLEX\u00ae VFD 2YSLCYK-J CPR-compliant cables span comprehensive 1.5\u2013300 mm\u00b2 conductor range across dual configuration portfolio (4-core and 3+3 earth conductor) optimized for North American mining equipment, outdoor industrial systems, frequency converter integration, and applications requiring EU regulatory compliance and mining safety certification.<\/p>\n\n<div class=\"tw\">\n<table>\n<caption>Table 10.1-B \u2014 GAALFLEX\u00ae VFD 2YSLCYK-J (0.6\/1 kV PE shielded, CPR Eca, mining-certified): Selected SKU portfolio (100+ total configurations) \u2014 4-Core Mining Version<\/caption>\n<thead><tr><th>Conductor Config<\/th><th>Size (mm\u00b2)<\/th><th>O.\u00d8 (mm)<\/th><th>Cu (kg\/km)<\/th><th>Weight (kg\/km)<\/th><th>Mining VFD Applications<\/th><\/tr><\/thead>\n<tbody>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">SMALL MINING MOTORS (1.5\u201310 mm\u00b2, 16\u20138 AWG) \u2014 Underground Hoist Drives, Control Motors<\/td><\/tr>\n<tr><td>4 G 1.5<\/td><td>1.5<\/td><td class=\"num\">11.1<\/td><td class=\"num\">95<\/td><td class=\"num\">226<\/td><td>Fractional-HP underground control drives<\/td><\/tr>\n<tr><td>4 G 2.5<\/td><td>2.5<\/td><td class=\"num\">12.5<\/td><td class=\"num\">150<\/td><td class=\"num\">290<\/td><td>0.5\u20132 HP mining servo control<\/td><\/tr>\n<tr><td>4 G 6<\/td><td>6<\/td><td class=\"num\">15.9<\/td><td class=\"num\">320<\/td><td class=\"num\">569<\/td><td>2\u20135 HP underground pump drives<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">STANDARD MINING EQUIPMENT (16\u201370 mm\u00b2, 6\u20132\/0 AWG) \u2014 Surface Conveyor, Ventilation, Crusher<\/td><\/tr>\n<tr><td>4 G 16<\/td><td>16<\/td><td class=\"num\">22.1<\/td><td class=\"num\">789<\/td><td class=\"num\">1195<\/td><td>5\u201310 HP mining conveyor drives<\/td><\/tr>\n<tr><td>4 G 25<\/td><td>25<\/td><td class=\"num\">25.9<\/td><td class=\"num\">1236<\/td><td class=\"num\">1710<\/td><td>10\u201315 HP mining ventilation motors<\/td><\/tr>\n<tr><td>4 G 70<\/td><td>70<\/td><td class=\"num\">38.7<\/td><td class=\"num\">3196<\/td><td class=\"num\">3830<\/td><td>30\u201340 HP surface crushing machinery<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">HIGH-POWER MINING (120\u2013300 mm\u00b2, 4\/0\u2013550 MCM) \u2014 Mill Motors, Hoist &#038; Pump Systems<\/td><\/tr>\n<tr><td>4 G 120<\/td><td>120<\/td><td class=\"num\">48.1<\/td><td class=\"num\">5435<\/td><td class=\"num\">6243<\/td><td>40\u201350 HP mining mill drives, underground hoists<\/td><\/tr>\n<tr><td>4 G 240<\/td><td>240<\/td><td class=\"num\">67<\/td><td class=\"num\">10013<\/td><td class=\"num\">11036<\/td><td>75\u2013100 HP major mining equipment<\/td><\/tr>\n<tr><td>4 G 300<\/td><td>300<\/td><td class=\"num\">71.5<\/td><td class=\"num\">12570<\/td><td class=\"num\">13800<\/td><td>100+ HP maximum mining power systems<\/td><\/tr>\n<tr><td colspan=\"6\" style=\"background:#E8E8E0;text-align:center;font-weight:600;\">All GAALFLEX\u00ae VFD 2YSLCYK-J SKUs (4-Core &#038; 3+3G\/Y versions, CPR Eca): 0.6\/1 kV PE shielded, aluminum tape + PETP foil + tinned copper braid triple-layer shielding, 4 kV test voltage, 1.5\u2013300 mm\u00b2 flexible Class 5 copper per IEC 60228, low mutual capacitance (70\u2013410 nF\/km), low coupling resistance (max 250 \u03a9\/km), black UV-resistant RAL 9005 PVC sheath (mining outdoor rated), temperature \u221240 to +70\u00b0C fixed \/ \u22125 to +70\u00b0C flexible with +90\u00b0C conductor and +250\u00b0C short-circuit capability, insulation resistance 200+ M\u03a9\u00b7km, radiation resistance 80\u00d710\u2076 cJ\/kg, flexible bending radius (10\u00d7d\u201320\u00d7d), CPR EU 305\/2011 + EN 50575:2014+A1:2016 compliance (Eca fire classification), hazardous-area capability (DIN VDE 0250), mining application certified, EMC certified (EN 55011, DIN VDE 0875, EN 61800-3), self-extinguishing flame-retardant (DIN VDE 0482-265-2-1), optional XLPE halogen-free 2XSLCHK-J version with SHF1 black Eca-rated sheath, RoHS\/CE certified. Optimized for underground and surface mining motor systems, outdoor mining equipment, frequency converter integration, EU-regulated mining operations, automotive and food industry applications with outdoor exposure, packaging and machine tool drives in mining-adjacent environments, and comprehensive North American and European mining automation infrastructure with regulatory compliance.<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/section>\n\n<\/section>\n\n<section class=\"refs\">\n<h2>Technical References<\/h2>\n<ol class=\"rl\">\n<li>European Union. (2011). <em>Regulation (EU) No. 305\/2011 of the European Parliament and of the Council of 9 March 2011 (Construction Products Regulation)<\/em>.<\/li>\n<li>European Committee for Standardization (CEN). (2016). <em>EN 50575:2014+A1:2016: Harmonized Standard for the Classification of the Reaction to Fire Performance of Cables\u2014Definitions, Requirements and Test Methods<\/em>.<\/li>\n<li>European Committee for Standardization (CEN). (2018). <em>EN 13501-1: Fire Classification of Construction Products and Building Elements\u2014Part 1: Classification Using Data from Reaction to Fire Tests<\/em>.<\/li>\n<li>International Electrotechnical Commission (IEC). (2023). <em>IEC 60228: Conductors of Insulated Cables and Cords<\/em>.<\/li>\n<li>International Electrotechnical Commission (IEC). (2023). <em>IEC 60332-1-2: Tests on Cables Under Fire Conditions\u2014Part 1-2: Test for Flammability of Vertically-Mounted Bunched Wires or Cables<\/em>.<\/li>\n<li>International Electrotechnical Commission (IEC). (2023). <em>IEC 60502-4: Power Cables with Extruded Insulation and Their Accessories for Rated Voltages up to 30 kV (Um = 36 kV)\u2014Part 4: XLPE Insulated Cables<\/em>.<\/li>\n<li>Deutsches Institut f\u00fcr Normung (DIN). (2023). <em>DIN VDE 0482 Part 265-2-1: Tests on Cables Under Fire Conditions<\/em>.<\/li>\n<li>Deutsches Institut f\u00fcr Normung (DIN). (2023). <em>DIN VDE 0250: Power Cables and Control Cables with Extruded Insulation<\/em>.<\/li>\n<li>Deutsches Institut f\u00fcr Normung (DIN). (2023). <em>DIN VDE 0875: Electromagnetic Compatibility\u2014Equipment for General Use<\/em>.<\/li>\n<li>International Electrotechnical Commission (IEC). (2023). <em>IEC 61800-3: Adjustable Speed Electrical Power Drive Systems\u2014Part 3: EMC Requirements and Specific Test Methods<\/em>.<\/li>\n<li>Feichun Cable Engineering. (2023). <em>VFD 2YSLCYK-J CPR-Compliant Inverter Connection Cable: Mining Application &#038; EU Regulatory Compliance<\/em>.<\/li>\n<li>European Mining Association. (2022). <em>CPR-Compliant Cable Standards for EU Mining Operations &#038; Underground Equipment<\/em>.<\/li>\n<li>Mining Safety Council. (2023). <em>DIN VDE 0250 &#038; Hazardous-Area Cable Requirements for Underground Mining<\/em>.<\/li>\n<li>CPR Compliance &#038; Fire Safety. (2022). <em>Eca Fire Classification Methodology &#038; Cable Testing per EN 50575<\/em>.<\/li>\n<li>Industrial Standards &#038; Outdoor Durability. (2023). <em>UV-Resistant Cable Compounds for Mining Equipment &#038; Environmental Exposure<\/em>.<\/li>\n<\/ol>\n<\/section>\n\n<section class=\"contact\">\n<h3>CPR-Compliant Mining &#038; Outdoor VFD Inverter Cable Solutions with EU Regulatory Compliance<\/h3>\n<p style=\"margin-bottom:1rem;color:var(--c-secondary);font-size:.88rem\">Comprehensive technical reference for electrical engineers, drive system integrators, mining equipment specialists, motor specialists, electrical contractors, and decision-makers selecting CPR-compliant shielded VFD inverter cables for North American industrial variable frequency drive installations with mining applications, outdoor frequency converter integration, motor power supply systems, hazardous-area motor control, automotive and food industry applications, and applications requiring complete EU regulatory compliance, environmental durability, low-capacitance signal integrity, mining equipment safety, and professional frequency converter system integration.<\/p>\n<div class=\"cg\">\n<div class=\"ci\"><span class=\"lb\">CPR-Compliant Mining VFD Systems<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Underground &#038; Surface Mining Motors<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">EU Regulatory Mining Equipment<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n<div class=\"ci\"><span class=\"lb\">Industrial Drive Solutions Division<\/span>Anhui Feichun Special Cable Co., Ltd.<\/div>\n<\/div>\n<\/section>\n\n<footer class=\"ft\">\n<p><strong>GAALFLEX\u00ae VFD 2YSLCYK-J: CPR-Compliant Mining &#038; Outdoor Variable Frequency Drive Inverter Connection Cable with EU Eca Fire Classification<\/strong> \u2014 Breakthrough CPR-compliant mining VFD cable combining PE special insulation with aluminum tape + PETP foil + tinned copper braid triple-layer shielding, EU 305\/2011 + EN 50575:2014+A1:2016 Eca fire classification enabling European market access, mining application certification per DIN VDE 0250 enabling underground and surface mining deployment, UV-resistant black RAL 9005 PVC outdoor sheath for equipment exposed areas, dual 4-core and 3+3 earth conductor configurations enabling complete mining VFD system standardization, comprehensive 1.5\u2013300 mm\u00b2 (16\u2013550 MCM) power spectrum coverage, low mutual capacitance (70\u2013410 nF\/km) minimizing bundled cable cross-talk, low coupling resistance (max 250 \u03a9\/km) supporting precision mining control, hazardous-area capability (DIN VDE 0250), EMC compliance (EN 55011 \/ DIN VDE 0875 \/ EN 61800-3), flexible Class 5 copper per IEC 60228, temperature \u221240 to +70\u00b0C (fixed) or \u22125 to +70\u00b0C (flexible) with +90\u00b0C conductor and +250\u00b0C short-circuit capability, optional XLPE halogen-free 2XSLCHK-J version with SHF1 black Eca-rated sheath, RoHS\/CE certified. Standardized portfolio (100+ 4-core &#038; 3+3G\/Y mining SKUs).<\/p>\n<p style=\"margin-top:.6rem\">CPR-compliant VFD cable for North American mining and industrial systems: underground and surface mining motor drives (hoists, conveyors, crushers, ventilation), mining equipment outdoor installation (exposed weather environments), frequency converter integration for EU mining operations (27 member state compliance), hazardous-area underground coal and methane environments, automotive and food industry outdoor motor applications, packaging and machine tool drives requiring CPR certification, EU-regulated equipment export, and comprehensive North American and European mining automation infrastructure requiring complete regulatory compliance, environmental durability, triple-layer EMI suppression, extended power spectrum, field installation flexibility, and professional frequency converter system integration.<\/p>\n<p style=\"margin-top:.8rem;font-weight:600;color:var(--c-secondary)\">For CPR-compliant mining VFD inverter connection cable solutions with EU regulatory compliance: <a href=\"mailto:Tech@feichuncables.com\" style=\"color:var(--c-link);text-decoration:none\">Tech@feichuncables.com<\/a> | Industrial Drive Solutions Division | Anhui Feichun Special Cable Co., Ltd.<\/p>\n<\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"GAALFLEX\u00ae VFD 2YSLCYK-J: CPR-Compliant (EU 305\/2011 + EN 50575:2014+A1:2016, Eca Classification) Variable Frequency Drive Inverter Connection Cable for North American Industrial Motor Power Supply, Mining Applications, and Outdoor Frequency Converter Systems (0.6\/1 kV Nominal Voltage, 4 kV Test Voltage, Comprehensive Dual-Configuration Portfolio [4-Core and 3+3 Earth Conductor Versions], 1.5\u2013300 mm\u00b2 Conductor Range Enabling Complete VFD Specification from Servo Drives Through Industrial Motors, Flexible Class 5 Red Copper per IEC 60228, PE Special Insulation Compound Providing Electrical Stability, Aluminum Tape + PETP Foil + Tinned Copper Braid Triple-Layer Shielding, Low Mutual Capacitance [70\u2013410 nF\/km], Low Coupling Resistance [Max 250 \u03a9\/km], Black RAL 9005 PVC Outer Sheath with UV Resistance Enabling Outdoor Mining and Industrial Installation Without Degradation, Temperature Range \u221240 to +70\u00b0C [Fixed] or \u22125 to +70\u00b0C [Flexible Application] with +90\u00b0C Conductor and +250\u00b0C Short-Circuit Capability, Hazardous-Area Installation per DIN VDE 0250, Electromagnetic Compatibility per EN 55011 \/ DIN VDE 0875 \/ EN 61800-3, Self-Extinguishing and Flame-Retardant per DIN VDE 0482-265-2-1, CPR Fire Classification Eca [EN 13501-1] Enabling European Regulatory Compliance, Optional XLPE Halogen-Free Version [2XSLCHK-J] per IEC 60502-4 with Eca-Rated Black SHF1 Sheath, Suitable for Mining Machinery, Outdoor Industrial Systems, Automotive and Food Automation with Environmental Exposure, and Complete International VFD Infrastructure Compliance with Regulatory Mandates)","protected":false},"author":1,"featured_media":11607,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[165,35,1],"tags":[57314,57606,57029,57014,505,57299,57620,57595,55139,57594,57540,57618,57619,57597,57614,16,18392,57611,56998,6335,57621,32814,57604,7034,57613,4491,56872,57615,57608,411,688,57616,57617,10296,57622,57596,57015,552,7048,57599,9750,57607],"class_list":["post-11606","post","type-post","status-publish","format-standard","has-post-thumbnail","category-drag-chain-cable","category-festoon-cable","category-uncategorized","tag-250c-short-circuit-4","tag-90c-conductor-2","tag-40-to-70c-fixed","tag-5-to-70c-flexible","tag-0-6-1-kv","tag-1-5-300-mm","tag-2xslchk-j","tag-33-earth-conductor","tag-4-kv-test-voltage","tag-4-core-2","tag-aluminum-tape","tag-black-ral-9005-pvc-outer-sheath","tag-black-shf1-sheath","tag-class-5-red-copper","tag-cpr-compliant-2","tag-din-vde-0250","tag-din-vde-0482-265-2-1","tag-din-vde-0875","tag-eca-classification","tag-electromagnetic-compatibility","tag-en-13501-1","tag-en-505752014a12016","tag-en-55011","tag-en-61800-3","tag-eu-305-2011","tag-feichun-cable","tag-flame-retardant-2","tag-gaalflex-vfd-2yslcyk-j","tag-hazardous-area-installation","tag-iec-60228","tag-iec-60502-4","tag-low-coupling-resistance-250--km","tag-low-mutual-capacitance-70-410-nf-km","tag-mining-applications","tag-outdoor-frequency-converter-systems","tag-pe-special-insulation","tag-petp-foil","tag-self-extinguishing","tag-tinned-copper-braid","tag-triple-layer-shielding","tag-uv-resistance","tag-xlpe-halogen-free-optional","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11606","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=11606"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11606\/revisions"}],"predecessor-version":[{"id":11612,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/11606\/revisions\/11612"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/11607"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=11606"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=11606"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=11606"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}