{"id":10426,"date":"2026-04-14T14:46:05","date_gmt":"2026-04-14T06:46:05","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=10426"},"modified":"2026-04-14T14:46:07","modified_gmt":"2026-04-14T06:46:07","slug":"k-60227-iec-02-kiv-450-750v-flexible-building-wiring-wire","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/k-60227-iec-02-kiv-450-750v-flexible-building-wiring-wire\/","title":{"rendered":"K 60227 IEC 02 (KIV) 450\/750V Flexible Building Wiring Wire"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Professional-Grade Indoor Electrical Wiring for Residential &amp; Commercial Applications \u2014 Polyvinyl Chloride (PVC) Insulation, Class 5 Flexible Stranded Annealed Copper Conductors, KS C IEC 60227-3 Standard Compliance, 70\u00b0C Continuous Temperature Rating, Extended Conductor Sizing (1.5\u2013240 sq mm), Comprehensive Standard Color Identification (Black, White, Red, Green, Yellow, Blue), Simplified Installation for Indoor Building Distribution, Superior Flexibility for Easy Routing, and Specialized Applications for Residential Wiring, Commercial Building Distribution Systems, Indoor Power Distribution, and Building Infrastructure Electrical Networks<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Complete Technical Reference for Electricians and Building Contractors: Understanding KIV Wire Architecture, Class 5 Flexible Conductor Design, PVC Insulation Properties, 450\/750V Electrical Performance, 70\u00b0C Continuous Temperature Rating, Conductor Sizing and Ampacity Optimization, Standard Color Coding System, Building Wiring Installation Practices, Conduit Routing and Cable Management, Electrical Safety Standards and Code Compliance, Circuit Protection and Breaker Coordination, Proper Termination Techniques, Quality Assurance Testing Standards, and Integration with Residential and Commercial Building Electrical Systems.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"f0e9e5\" data-has-transparency=\"false\" style=\"--dominant-color: #f0e9e5;\" loading=\"lazy\" decoding=\"async\" width=\"748\" height=\"628\" sizes=\"auto, (max-width: 748px) 100vw, 748px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1185-748x628.avif\" alt=\"\" class=\"wp-image-10428 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1185-748x628.avif 748w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1185-300x252.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1185-400x336.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1185.avif 753w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>K 60227 IEC 02 (KIV) 450\/750V Flexible Building Wiring Wire \u2014 Indoor Installation | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical reference for K 60227 IEC 02 (KIV) 450\/750V flexible single-core vinyl insulated building wiring wire engineered for residential and commercial indoor electrical installations. Comprehensive coverage of Class 5 flexible stranded annealed copper conductors, polyvinyl chloride insulation, KS C IEC 60227-3 standard compliance, 70\u00b0C continuous temperature rating, extended conductor sizing (1.5\u2013240 sq mm), standard color identification, optimized flexibility for internal building wiring, simplified installation procedures, and specialized applications for residential wiring, commercial building distribution, and indoor power systems.\">\n<meta name=\"keywords\" content=\"KIV wire, building wire, 450\/750V wire, residential wiring, indoor wire, flexible wire, vinyl insulated wire, KS C 60227-3, Class 5 flexible\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<meta name=\"robots\" content=\"index,follow\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#0066CC;--c-link-hover:#004499;--c-accent:#0066CC;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#0066CC;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;--hl-red-glow:rgba(255,60,60,0.08)}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#6BA3FF;--c-link-hover:#8CB5FF;--c-accent:#6BA3FF;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#6BA3FF;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#6BA3FF;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;--hl-red-glow:rgba(255,60,60,0.15)}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden}.page-wrap{max-width:920px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.5rem,3.7vw,2.15rem);line-height:1.22;margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-en{font-size:.82rem;color:var(--c-tertiary);line-height:1.5;font-style:italic;margin-top:.5rem;padding-top:.5rem;border-top:1px solid var(--b-light)}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify}.body strong{font-weight:600;color:var(--c-body)}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.78rem;line-height:1.35}.tw caption{text-align:left;font-weight:600;font-size:.74rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.68rem;padding:.5rem .55rem;text-align:left;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.35rem .55rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55}.feature-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:1rem;margin:1.5rem 0 2rem}.feature-card{background:var(--bg-surface);border:1px solid var(--b-light);border-radius:4px;padding:1rem;text-align:left}.feature-card h4{font-weight:700;font-size:.92rem;margin-bottom:.3rem;color:var(--c-body)}.feature-card p{font-size:.81rem;color:var(--c-secondary);margin-bottom:0}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.3rem}.tw{font-size:.72rem}.feature-grid{grid-template-columns:1fr}}<\/style>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechArticle\",\"headline\":\"K 60227 IEC 02 (KIV) 450\/750V Flexible Building Wiring Wire\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"datePublished\":\"2026-04-14\"}<\/script>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">KIV Wire Family<\/span>\n    <span class=\"badge\">Building Wire<\/span>\n    <span class=\"badge\">450\/750V Rated<\/span>\n    <span class=\"badge\">Residential<\/span>\n    <h1>K 60227 IEC 02 (KIV) 450\/750V Flexible Building Wiring Wire<\/h1>\n    <p class=\"sub\">Professional-Grade Indoor Electrical Wiring for Residential &#038; Commercial Applications \u2014 Polyvinyl Chloride (PVC) Insulation, Class 5 Flexible Stranded Annealed Copper Conductors, KS C IEC 60227-3 Standard Compliance, 70\u00b0C Continuous Temperature Rating, Extended Conductor Sizing (1.5\u2013240 sq mm), Comprehensive Standard Color Identification (Black, White, Red, Green, Yellow, Blue), Simplified Installation for Indoor Building Distribution, Superior Flexibility for Easy Routing, and Specialized Applications for Residential Wiring, Commercial Building Distribution Systems, Indoor Power Distribution, and Building Infrastructure Electrical Networks<\/p>\n    <p class=\"sub-en\">Complete Technical Reference for Electricians and Building Contractors: Understanding KIV Wire Architecture, Class 5 Flexible Conductor Design, PVC Insulation Properties, 450\/750V Electrical Performance, 70\u00b0C Continuous Temperature Rating, Conductor Sizing and Ampacity Optimization, Standard Color Coding System, Building Wiring Installation Practices, Conduit Routing and Cable Management, Electrical Safety Standards and Code Compliance, Circuit Protection and Breaker Coordination, Proper Termination Techniques, Quality Assurance Testing Standards, and Integration with Residential and Commercial Building Electrical Systems.<\/p>\n    <div class=\"meta\">\n      <span>Anhui Feichun Special Cable Co., Ltd.<\/span>\n      <span>Published April 2026<\/span>\n      <span>12 min technical reference<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">KIV Wire Architecture &#038; Building Wiring Design Philosophy<\/a><\/li>\n      <li><a href=\"#s2\">Polyvinyl Chloride (PVC) Insulation for Indoor Applications<\/a><\/li>\n      <li><a href=\"#s3\">Class 5 Flexible Stranded Conductor Design<\/a><\/li>\n      <li><a href=\"#s4\">450\/750V Voltage Rating &#038; Building System Performance<\/a><\/li>\n      <li><a href=\"#s5\">Temperature Performance: 70\u00b0C Continuous Rating<\/a><\/li>\n      <li><a href=\"#s6\">Conductor Sizing &#038; Ampacity for Building Distribution<\/a><\/li>\n      <li><a href=\"#s7\">Color Identification &#038; Circuit Organization<\/a><\/li>\n      <li><a href=\"#s8\">Technical Specifications: KIV Wire Series (1.5\u2013240 sq mm)<\/a><\/li>\n      <li><a href=\"#s9\">Single-Core Flexibility &#038; Installation Advantages<\/a><\/li>\n      <li><a href=\"#s10\">Building Wiring Installation &#038; Conduit Routing<\/a><\/li>\n      <li><a href=\"#s11\">Safety Standards &#038; Electrical Code Compliance<\/a><\/li>\n      <li><a href=\"#s12\">Quality Assurance &#038; Testing Standards<\/a><\/li>\n      <li><a href=\"#s13\">Product Support &#038; Installation Consultation<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <!-- ===== S1 ===== -->\n  <section class=\"body\" id=\"s1\">\n    <h2>KIV Wire Architecture &#038; Building Wiring Design Philosophy<\/h2>\n\n    <p><strong>Purpose &#038; Application Scope:<\/strong> KIV (Korean Industrial Vinyl) flexible single-core building wire represents the engineered solution for residential and commercial indoor electrical wiring requiring simplified installation, practical flexibility, and reliable performance throughout decades of building service. Unlike power distribution cables designed for specialized applications (underground, portable, equipment), KIV wires are specifically engineered for standardized building electrical systems where simplicity, compatibility with standard conduit systems, and proven reliability across diverse building types create essential requirements.<\/p>\n\n    <p><strong>Core Engineering Philosophy:<\/strong> KIV wire design emphasizes practical flexibility enabling easy routing through building conduit systems, standard interface with residential and commercial electrical infrastructure, proven long-term reliability, and economy of installation. Class 5 flexible stranding enables routing through conduit bends, simplified pulling during installation, and practical handling without specialized equipment. Standard PVC insulation provides proven performance across indoor building environments, standard electrical interfaces, and cost-effective manufacturing enabling competitive pricing for high-volume residential and commercial construction markets.<\/p>\n\n    <p><strong>Market Position &#038; Regulatory Compliance:<\/strong> KIV wires comply with KS C IEC 60227-3 international standard specifications\u2014the recognized standard for flexible building wiring worldwide. The 450\/750V rating addresses standard 400V three-phase (230V single-phase) building power distributions universal across modern residential and commercial infrastructure. Building electrical codes in most jurisdictions specifically reference KS C IEC 60227-3 or equivalent standards, making KIV wires the standard choice for compliant building installation.<\/p>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">Design Principle: Practical Building Integration<\/div>\n      <p>KIV wires prioritize practical flexibility, standard building electrical system compatibility, and proven long-term reliability enabling simplified installation across diverse residential and commercial building projects. This design philosophy enables wires that integrate seamlessly with existing building electrical infrastructure while maintaining safe, reliable power distribution throughout building service life spanning 30\u201350+ years.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S2 ===== -->\n  <section class=\"body\" id=\"s2\">\n    <h2>Polyvinyl Chloride (PVC) Insulation for Indoor Applications<\/h2>\n\n    <p><strong>Material Chemistry &#038; Indoor Optimization:<\/strong> PVC insulation employed in KIV wires combines base polyvinyl chloride polymer with plasticizers, stabilizers, and UV absorbers specifically formulated for indoor building environments. Indoor-optimized PVC formulations prioritize mechanical flexibility for easy installation, electrical performance across temperature range typical of buildings (typically 10\u201340\u00b0C), and resistance to common indoor contaminants (dust, humidity, indoor air quality variations). This formulation provides proven long-term reliability across decades of indoor building service.<\/p>\n\n    <p><strong>Electrical Performance &#038; Building Safety:<\/strong> PVC insulation provides dielectric strength (voltage withstand capability) appropriate for 450\/750V building applications. Standard test voltage of 2,000V for 1 minute duration verifies insulation integrity\u2014approximately 2.7\u20134.4 times maximum operating voltage. PVC maintains consistent electrical properties across building operating temperature ranges (5\u201340\u00b0C typical, occasional extremes to \u22125\u201350\u00b0C in attics or mechanical spaces), delivering reliable insulation performance and electrical safety throughout building service life.<\/p>\n\n    <p><strong>Mechanical Properties &#038; Practical Flexibility:<\/strong> PVC insulation demonstrates excellent flexibility enabling practical routing through building conduit systems. The polymer structure remains pliable even at cold temperatures (5\u00b0C minimum typical building temperatures in winter or attics) enabling flexible handling without brittle insulation cracking. This mechanical property enables electricians to route wires efficiently through building systems without requiring heating or special conditioning procedures.<\/p>\n\n    <p><strong>Moisture &#038; Environmental Resistance:<\/strong> Indoor building environments expose wires to humidity variation, occasional moisture, dust accumulation, and diverse air quality conditions. PVC insulation resists moisture absorption enabling reliable operation even in humid basements, bathrooms, and humid climates. The polymer structure remains stable across typical indoor environmental conditions supporting long-term reliability without performance degradation.<\/p>\n\n  <\/section>\n\n  <!-- ===== S3 ===== -->\n  <section class=\"body\" id=\"s3\">\n    <h2>Class 5 Flexible Stranded Conductor Design<\/h2>\n\n    <p><strong>Flexible Stranding &#038; Installation Ease:<\/strong> KIV wires employ Class 5 flexible stranding with thin individual wire diameter enabling practical routing through building conduit systems without excessive mechanical stress or insulation damage. Flexible stranding enables wires to navigate conduit bends, follow wall cavities, and route around building obstacles without requiring conduit size increases or complicated routing schemes.<\/p>\n\n    <p><strong>Bend Radius &#038; Practical Installation:<\/strong> Class 5 stranding enables practical bend radius (typically 8\u201310 times wire diameter) enabling routing through standard building conduit and practical installation without special equipment. Electricians can route KIV wires through buildings using proven standard installation techniques developed across decades of residential and commercial construction projects.<\/p>\n\n    <p><strong>Electrical Performance &#038; Current Distribution:<\/strong> Class 5 stranding distributes current uniformly across all individual wires preventing localized overheating. This current distribution prevents insulation damage from concentrated current flow, supporting reliable long-term operation at rated ampacity. Electrical properties remain consistent across the wire cross-section enabling predictable performance in building electrical systems.<\/p>\n\n    <p><strong>Annealed Copper Conductors:<\/strong> KIV wires employ annealed copper conductors providing optimal balance between mechanical flexibility and electrical conductivity. Annealed copper maintains flexibility across temperature cycles and mechanical stress while sustaining excellent electrical conductivity supporting efficient power transmission throughout building systems.<\/p>\n\n  <\/section>\n\n  <!-- ===== S4 ===== -->\n  <section class=\"body\" id=\"s4\">\n    <h2>450\/750V Voltage Rating &#038; Building System Performance<\/h2>\n\n    <p><strong>Voltage Rating &#038; Building Applications:<\/strong> The 450\/750V designation indicates insulation rated for 450V phase-to-neutral and 750V phase-to-phase stresses in three-phase AC building systems. This rating covers standard 400V three-phase (230V single-phase) electrical distribution\u2014the universal standard for residential and commercial building power systems worldwide. KIV wires safely operate at continuous supply voltages throughout building systems from residential 230V single-phase through commercial 400V three-phase industrial power distribution.<\/p>\n\n    <p><strong>Insulation Thickness &#038; Safety Margin:<\/strong> PVC insulation thickness (0.7\u20132.2 mm depending on conductor size) provides adequate insulation thickness for 450\/750V rating. Dielectric withstand test at 2,000V verifies insulation robustness. This design margin protects against transient overvoltages from lightning, utility switching, or motor starting transients common in building electrical systems. This design margin ensures insulation integrity across the building service life.<\/p>\n\n    <p><strong>Compatibility with Building Infrastructure:<\/strong> KIV wires maintain compatible performance for connection with standard building electrical equipment\u2014circuit breakers, contactors, termination boxes, and standard electrical connections universal across residential and commercial construction. Standard 450\/750V rating ensures compatibility with diverse building electrical loads from lighting and receptacles through motor circuits and large commercial equipment.<\/p>\n\n  <\/section>\n\n  <!-- ===== S5 ===== -->\n  <section class=\"body\" id=\"s5\">\n    <h2>Temperature Performance: 70\u00b0C Continuous Rating<\/h2>\n\n    <p><strong>Thermal Rating for Building Applications:<\/strong> The 70\u00b0C maximum temperature rating indicates maximum sustained conductor temperature permissible during continuous operation. This rating reflects PVC insulation thermal limits appropriate for building electrical systems where moderate temperature rise from normal current operation is expected. At 70\u00b0C, PVC insulation maintains electrical properties and mechanical stability throughout decades of building service.<\/p>\n\n    <p><strong>Heat Generation &#038; Building Ampacity:<\/strong> Conductor current capacity depends on heat generation from electrical resistance balanced against thermal dissipation in building installation environments. Building installations (conduit in walls, attics, mechanical spaces) provide moderate thermal dissipation enabling ampacity values supporting typical building power requirements. Standard ampacity tables account for building installation methods providing practical current ratings.<\/p>\n\n    <p><strong>Long-Term Building Reliability:<\/strong> Proper conductor sizing maintaining operation at 50\u201360\u00b0C (rather than pushing toward 70\u00b0C maximum) during normal building operation extends wire life to 40\u201350+ years\u2014matching typical building service life expectations. This extended operational life supports long-term building reliability without frequent electrical system upgrades or repairs.<\/p>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Building Temperature Principle<\/div>\n      <p>The 70\u00b0C rating is appropriate for typical building installations where conduit routing and building ventilation provide moderate thermal environments. Proper conductor sizing ensures normal operation at comfortable temperature margins below maximum rating, supporting long-term reliability matching building service life expectations of 40\u201350+ years.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S6 ===== -->\n  <section class=\"body\" id=\"s6\">\n    <h2>Conductor Sizing &#038; Ampacity for Building Distribution<\/h2>\n\n    <p><strong>Comprehensive Conductor Range:<\/strong> KIV wires offer practical conductor sizing from 1.5 sq mm (light circuits, 230V single-phase outlets) through 240 sq mm (large power feeders, three-phase industrial). This comprehensive range enables single wire type to serve all building power distribution requirements\u2014from control circuits through main power feeders. Standardized sizing simplifies inventory and enables electricians to select appropriate wire sizes for any building circuit.<\/p>\n\n    <p><strong>Copper Conductors &#038; Resistance:<\/strong> All KIV wires employ annealed copper conductors with specified resistance values (provided in technical specifications). Standard copper resistance enables power loss calculations: Power Loss (W) = Current\u00b2 (A) \u00d7 Resistance (\u03a9\/km) \u00d7 Length (km). Calculations enable proper conductor selection minimizing voltage drop and heat generation in building circuits.<\/p>\n\n    <p><strong>Ampacity Rating &#038; Circuit Protection:<\/strong> Standard ampacity tables provide current ratings for various installation methods (in-wall conduit, surface-mounted, underground, in cable tray). Circuit breakers or fuses must be selected matching wire ampacity ensuring protection during overload conditions. Proper coordination between wire ampacity and circuit protection ensures safety throughout building electrical system.<\/p>\n\n    <p><strong>Voltage Drop Calculations:<\/strong> For extended circuit runs (long circuits in large buildings), voltage drop may exceed allowable limits (typically 2\u20133% maximum). Voltage drop calculations: Voltage Drop (V) = Current (A) \u00d7 Resistance (\u03a9\/km) \u00d7 Length (km) enable proper conductor selection preventing excessive voltage drop. Detailed guidance for voltage drop calculations is available from Feichun engineering support.<\/p>\n\n  <\/section>\n\n  <!-- ===== S7 ===== -->\n  <section class=\"body\" id=\"s7\">\n    <h2>Color Identification &#038; Circuit Organization<\/h2>\n\n    <p><strong>Standard Building Color System:<\/strong> KIV wires employ internationally standardized color identification: Black (Phase 1), White (Neutral), Red (Phase 2\/Auxiliary), Green (Protective Earth\/Ground), Yellow (Auxiliary), Blue (Secondary Power\/Control). This color system has become universal for building electrical systems worldwide enabling electricians to maintain consistent circuit identification across diverse projects and regions.<\/p>\n\n    <p><strong>Circuit Organization &#038; Maintenance:<\/strong> Standardized color coding enables electricians to quickly identify circuit function and voltage levels during installation, maintenance, and troubleshooting. Consistent color identification reduces error risk during circuit modifications and supports safe building electrical system operation throughout service life.<\/p>\n\n    <p><strong>Building Documentation Requirements:<\/strong> Building electrical plans and documentation must explicitly reference wire colors for all circuits. Single-line diagrams identify which phase, neutral, and ground conductors serve each circuit. This documentation becomes essential for future maintenance, repairs, and building modifications supporting safe operation throughout building lifetime.<\/p>\n\n    <p><strong>Safety &#038; Code Compliance:<\/strong> Proper color identification and circuit organization satisfy electrical code requirements across all building types and jurisdictions. Standard color coding enables code inspectors to verify compliance and enables safe electrical system operation supporting occupant safety and building protection.<\/p>\n\n    <div class=\"feature-grid\">\n      <div class=\"feature-card\">\n        <h4>Black (Phase 1)<\/h4>\n        <p>Primary AC power phase conductor carrying building power distribution<\/p>\n      <\/div>\n      <div class=\"feature-card\">\n        <h4>White (Neutral)<\/h4>\n        <p>Neutral return conductor completing building circuits and providing reference voltage<\/p>\n      <\/div>\n      <div class=\"feature-card\">\n        <h4>Red (Phase 2\/Auxiliary)<\/h4>\n        <p>Second phase in three-phase systems or auxiliary power in single-phase installations<\/p>\n      <\/div>\n      <div class=\"feature-card\">\n        <h4>Green (Protective Earth)<\/h4>\n        <p>Safety grounding conductor protecting building systems and personnel from electrical hazards<\/p>\n      <\/div>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S8 ===== -->\n  <section class=\"body\" id=\"s8\">\n    <h2>Technical Specifications: KIV Wire Series (1.5\u2013240 sq mm)<\/h2>\n\n    <p><strong>Comprehensive Building Wire Range:<\/strong> KIV wires span practical building applications from 1.5 sq mm (light circuits) through 240 sq mm (large commercial feeders). Each conductor size specifies Class 5 stranding configuration, insulation thickness, conductor resistance, and ampacity for standard building installation methods. The following table provides representative specifications\u2014complete data for all conductor sizes and configurations available.<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>KIV Wire Technical Specifications \u2014 Single-Core Class 5 (450\/750V, 70\u00b0C Rating)<\/caption>\n        <thead>\n          <tr>\n            <th>Conductor (sq mm)<\/th>\n            <th>Wire Dia. (mm)<\/th>\n            <th>Insulation (mm)<\/th>\n            <th>Sheath O.D. Min (mm)<\/th>\n            <th>Sheath O.D. Max (mm)<\/th>\n            <th>Conductor Resist. Copper (\u03a9\/km)<\/th>\n            <th>Test Voltage (V)<\/th>\n            <th>Insulation Resist. (M\u03a9\u00b7km)<\/th>\n            <th>Weight (kg\/km)<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr>\n            <td>1.5<\/td>\n            <td>1.6<\/td>\n            <td>0.7<\/td>\n            <td>2.8<\/td>\n            <td>3.4<\/td>\n            <td>13.3<\/td>\n            <td>2,000<\/td>\n            <td>0.010<\/td>\n            <td>30<\/td>\n          <\/tr>\n          <tr>\n            <td>2.5<\/td>\n            <td>2.63<\/td>\n            <td>0.8<\/td>\n            <td>3.4<\/td>\n            <td>4.1<\/td>\n            <td>7.98<\/td>\n            <td>2,000<\/td>\n            <td>0.009<\/td>\n            <td>40<\/td>\n          <\/tr>\n          <tr>\n            <td>4<\/td>\n            <td>3.6<\/td>\n            <td>0.8<\/td>\n            <td>3.9<\/td>\n            <td>4.8<\/td>\n            <td>4.95<\/td>\n            <td>2,000<\/td>\n            <td>0.007<\/td>\n            <td>50<\/td>\n          <\/tr>\n          <tr>\n            <td>6<\/td>\n            <td>4.4<\/td>\n            <td>0.8<\/td>\n            <td>4.4<\/td>\n            <td>5.3<\/td>\n            <td>3.30<\/td>\n            <td>2,000<\/td>\n            <td>0.006<\/td>\n            <td>80<\/td>\n          <\/tr>\n          <tr>\n            <td>10<\/td>\n            <td>5.7<\/td>\n            <td>1.0<\/td>\n            <td>5.7<\/td>\n            <td>6.8<\/td>\n            <td>1.91<\/td>\n            <td>2,000<\/td>\n            <td>0.0056<\/td>\n            <td>130<\/td>\n          <\/tr>\n          <tr>\n            <td>16<\/td>\n            <td>6.7<\/td>\n            <td>1.0<\/td>\n            <td>6.7<\/td>\n            <td>8.1<\/td>\n            <td>1.21<\/td>\n            <td>2,000<\/td>\n            <td>0.0046<\/td>\n            <td>180<\/td>\n          <\/tr>\n          <tr>\n            <td>25<\/td>\n            <td>8.4<\/td>\n            <td>1.2<\/td>\n            <td>8.4<\/td>\n            <td>10.2<\/td>\n            <td>0.780<\/td>\n            <td>2,000<\/td>\n            <td>0.0044<\/td>\n            <td>280<\/td>\n          <\/tr>\n          <tr>\n            <td>35<\/td>\n            <td>9.7<\/td>\n            <td>1.2<\/td>\n            <td>9.7<\/td>\n            <td>11.7<\/td>\n            <td>0.554<\/td>\n            <td>2,000<\/td>\n            <td>0.0038<\/td>\n            <td>370<\/td>\n          <\/tr>\n          <tr>\n            <td>50<\/td>\n            <td>11.5<\/td>\n            <td>1.4<\/td>\n            <td>11.5<\/td>\n            <td>13.9<\/td>\n            <td>0.386<\/td>\n            <td>2,000<\/td>\n            <td>0.0037<\/td>\n            <td>500<\/td>\n          <\/tr>\n          <tr>\n            <td>70<\/td>\n            <td>13.2<\/td>\n            <td>1.4<\/td>\n            <td>13.2<\/td>\n            <td>16.0<\/td>\n            <td>0.272<\/td>\n            <td>2,000<\/td>\n            <td>0.0032<\/td>\n            <td>700<\/td>\n          <\/tr>\n          <tr>\n            <td>95<\/td>\n            <td>15.1<\/td>\n            <td>1.6<\/td>\n            <td>15.1<\/td>\n            <td>18.2<\/td>\n            <td>0.206<\/td>\n            <td>2,000<\/td>\n            <td>0.0032<\/td>\n            <td>970<\/td>\n          <\/tr>\n          <tr>\n            <td>120<\/td>\n            <td>16.7<\/td>\n            <td>1.6<\/td>\n            <td>16.7<\/td>\n            <td>20.2<\/td>\n            <td>0.161<\/td>\n            <td>2,000<\/td>\n            <td>0.0029<\/td>\n            <td>1,200<\/td>\n          <\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S9 ===== -->\n  <section class=\"body\" id=\"s9\">\n    <h2>Single-Core Flexibility &#038; Installation Advantages<\/h2>\n\n    <p><strong>Single-Core Design Benefits:<\/strong> Single-core configuration enables individual conductors (phase, neutral, ground) to be routed independently throughout building systems optimizing for wall cavity dimensions, conduit routing, and building structural constraints. This flexibility simplifies building design and installation enabling electricians to work efficiently with existing building architecture rather than requiring special conduit or routing modifications.<\/p>\n\n    <p><strong>Practical Installation &#038; Pulling Advantages:<\/strong> Single-core wires are simpler and less expensive to pull through building conduit compared to multi-conductor cables. Individual wires require less pulling force and enable use of smaller conduit sizes reducing building construction cost. This practical advantage has made single-core wires the universal standard for residential and commercial building installations worldwide.<\/p>\n\n    <p><strong>Flexibility for Building Modifications:<\/strong> Single-core design enables future circuit modifications and building upgrades without requiring complete rewiring. Additional circuits can be added by routing new single-core conductors through existing conduit (if capacity permits) or parallel new conduit simplifying building system expansion.<\/p>\n\n    <p><strong>Color-Coded Identification:<\/strong> Single-core design with standardized color identification enables electricians to rapidly trace circuits and identify voltage levels during installation and maintenance. Color coding eliminates reliance on labeling or documentation for circuit identification simplifying field work and reducing error risk.<\/p>\n\n  <\/section>\n\n  <!-- ===== S10 ===== -->\n  <section class=\"body\" id=\"s10\">\n    <h2>Building Wiring Installation &#038; Conduit Routing<\/h2>\n\n    <p><strong>Conduit Selection &#038; Installation:<\/strong> Building electrical codes specify conduit size based on wire size, wire insulation thickness, and number of wires in conduit. Generally, conduit fill should not exceed 40% of conduit cross-sectional area enabling adequate wire pulling force and future wire addition. Proper conduit selection ensures practical installation and enables future modifications without requiring conduit replacement.<\/p>\n\n    <p><strong>Wire Pulling &#038; Installation Techniques:<\/strong> Proper wire pulling requires adequate pulling force and proper pulling techniques preventing insulation damage. Pulling lugs or draw-boxes simplify pulling procedures. Wire lubricants can reduce pulling friction enabling longer pulls. Standard pulling speeds and techniques have been refined across decades of building installation practice.<\/p>\n\n    <p><strong>Grounding &#038; Safety Connections:<\/strong> Green ground conductors must establish low-resistance connections to equipment grounding buses and building structural grounding systems. Proper grounding connections enable fault currents to safely return during short-circuit conditions protecting building systems and personnel from electrical hazards. Grounding connection integrity is verified during building electrical inspection.<\/p>\n\n    <p><strong>Termination &#038; Connection Procedures:<\/strong> Wire terminations at breakers, receptacles, and equipment must be performed properly ensuring reliable electrical contact. Proper termination torque, connection types, and terminal sizing ensure connections remain tight throughout building operation. Loose connections create fire hazard and must be corrected immediately.<\/p>\n\n  <\/section>\n\n  <!-- ===== S11 ===== -->\n  <section class=\"body\" id=\"s11\">\n    <h2>Safety Standards &#038; Electrical Code Compliance<\/h2>\n\n    <p><strong>Building Electrical Code Requirements:<\/strong> KIV wires comply with KS C IEC 60227-3 standard which is incorporated into building electrical codes worldwide. Compliance ensures wires meet safety requirements, performance expectations, and design reliability standards established by regulatory authorities. Building inspections verify wire compliance during construction and enable safe building operation.<\/p>\n\n    <p><strong>Circuit Protection &#038; Coordination:<\/strong> Electrical codes require circuit protection (breakers or fuses) sized to protect wires from overload damage. Proper breaker sizing prevents excessive current preventing insulation damage before protection operates. Coordination between breaker rating and wire ampacity ensures safety throughout building electrical system.<\/p>\n\n    <p><strong>Grounding &#038; Bonding Requirements:<\/strong> Building codes require proper grounding and bonding of all exposed conductive materials ensuring occupant protection from ground-fault hazards. Green (ground) conductors must be properly installed and connected establishing complete protective grounding system throughout building.<\/p>\n\n    <p><strong>Inspection &#038; Acceptance Procedures:<\/strong> Completed building electrical systems must pass inspections verifying compliance with electrical codes. Inspectors verify proper wire sizing, grounding connections, circuit protection, and overall system safety. Inspection approval ensures building operates safely supporting occupant protection and property protection throughout building service life.<\/p>\n\n  <\/section>\n\n  <!-- ===== S12 ===== -->\n  <section class=\"body\" id=\"s12\">\n    <h2>Quality Assurance &#038; Testing Standards<\/h2>\n\n    <p><strong>Manufacturing Quality Testing:<\/strong> Every KIV wire batch undergoes comprehensive quality verification before shipment. Testing includes electrical performance verification (2,000V dielectric withstand for 1 minute), insulation resistance measurement ensuring moisture ingress has not compromised properties, and conductor continuity testing confirming internal integrity.<\/p>\n\n    <p><strong>Mechanical Property Validation:<\/strong> Tensile strength testing verifies conductor copper quality and stranding integrity. Elongation-at-break testing (minimum standards) confirms proper PVC formulation. Insulation abrasion testing verifies outer PVC layer withstands mechanical handling and building installation stresses.<\/p>\n\n    <p><strong>Environmental Testing:<\/strong> PVC insulation aging testing confirms material stability across long-term indoor building service. Moisture resistance testing verifies insulation maintains properties in humid building environments. Temperature cycling (5\u201340\u00b0C typical building range) confirms material stability across seasons and building geographic locations.<\/p>\n\n    <p><strong>Standards Compliance &#038; Certification:<\/strong> All KIV wires comply with KS C IEC 60227-3 international standard. Complete batch testing documentation with Certificate of Conformance is provided. Independent accredited laboratories perform testing enabling third-party compliance verification supporting building code acceptance.<\/p>\n\n  <\/section>\n\n  <!-- ===== S13 ===== -->\n  <section class=\"body\" id=\"s13\">\n    <h2>Product Support &#038; Installation Consultation<\/h2>\n\n    <p><strong>Standard Product Availability:<\/strong> Complete KIV wire range (1.5\u2013240 sq mm, all standard colors: Black, White, Red, Green, Yellow, Blue) is maintained in inventory. All standard conductor configurations are immediately available for orders. Flexible inventory enables electricians and contractors to source wires efficiently for any building project.<\/p>\n\n    <p><strong>Technical Engineering Support:<\/strong> Feichun engineers provide professional consultation including circuit load analysis and conductor sizing calculations, voltage drop analysis for extended circuits, conduit sizing recommendations, and building installation planning guidance. Contact <strong>Tech@feichuncables.com<\/strong> for professional engineering consultation supporting specific building projects.<\/p>\n\n    <p><strong>Building Contractor Support:<\/strong> On-site technical representatives are available for consultation during large building projects. Support includes installation quality verification, grounding system design, and building code compliance assessment ensuring projects meet all regulatory requirements and performance expectations.<\/p>\n\n    <p><strong>Warranty &#038; Support Services:<\/strong> KIV wires are backed by comprehensive warranty covering manufacturing defects. Extended warranties are available for critical building applications. 24\/7 technical support provides rapid problem-solving for unexpected issues during installation or building operation.<\/p>\n\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Anhui Feichun Special Cable Co., Ltd. \u2014 KIV Building Wire Specialists<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\"><span class=\"lb\">KIV Wire Selection &#038; Building Design<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Building Electrical System Planning<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Installation &#038; Code Compliance Support<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">24\/7 Technical Support<\/span>+86 138 5608 5607<\/div>\n      <div class=\"ci\"><span class=\"lb\">Project WhatsApp &#038; WeChat<\/span>+86 138 5512 3218<\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>This comprehensive technical reference covers K 60227 IEC 02 (KIV) 450\/750V flexible single-core vinyl insulated building wiring wire families engineered for residential and commercial electrical installations. Complete coverage of polyvinyl chloride insulation technology, Class 5 flexible stranded copper conductor design, KS C IEC 60227-3 standard compliance, 70\u00b0C continuous temperature rating, extended conductor sizing (1.5\u2013240 sq mm), standard color identification system, building installation practices, electrical safety standards and code compliance, quality assurance testing standards, and comprehensive engineering support services. KIV building wires provide proven solutions for indoor electrical installations across residential homes, commercial buildings, and industrial facilities where reliable, flexible, code-compliant wiring enables safe electrical distribution throughout building service life.<\/p>\n  <\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"KIV Wire Architecture &#038; Building Wiring Design Philosophy\nPurpose &#038; Application Scope: KIV (Korean Industrial Vinyl) flexible single-core building wire represents the engineered solution for residential and commercial indoor electrical wiring requiring simplified installation, practical flexibility, and reliable performance throughout decades of building service. Unlike power distribution cables designed for specialized applications (underground, portable, equipment), KIV wires are specifically engineered for standardized building electrical systems where simplicity, compatibility with standard conduit systems, and proven reliability across diverse building types create essential requirements.\nCore Engineering Philosophy: KIV wire design emphasizes practical flexibility enabling easy routing through building conduit systems, standard interface with residential and commercial electrical infrastructure, proven long-term reliability, and economy of installation. Class 5 flexible stranding enables routing through conduit bends, simplified pulling during installation, and practical handling without specialized equipment. Standard PVC insulation provides proven performance across indoor building environments, standard electrical interfaces, and cost-effective manufacturing enabling competitive pricing for high-volume residential and commercial construction markets.\nMarket Position &#038; Regulatory Compliance: KIV wires comply with KS C IEC 60227-3 international standard specifications\u2014the recognized standard for flexible building wiring worldwide. The 450\/750V rating addresses standard 400V three-phase (230V single-phase) building power distributions universal across modern residential and commercial infrastructure. Building electrical codes in most jurisdictions specifically reference KS C IEC 60227-3 or equivalent standards, making KIV wires the standard choice for compliant building installation.","protected":false},"author":1,"featured_media":10428,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,35,464],"tags":[52287,52379,52363,52356,52286,52560,52357,52359,52386,52454,52367,52239,52368,52420,52358,507,20710,9938,52480,52470,52571,52479,1048,52477,20982,52570,52473,52478,5204,52391,4491,52455,52471,44977,52568,52566,698,52459,52453,52565,52567,37497,52403,13524,52146,52476,52564,52456,52393,7646,708,44966,52457,18663,52466,52569,52463],"class_list":["post-10426","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-festoon-cable","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","tag-1-5-sq-mm","tag-10-sq-mm","tag-120-sq-mm","tag-16-sq-mm","tag-2-5-sq-mm","tag-2000v-test-voltage","tag-25-sq-mm","tag-35-sq-mm","tag-4-sq-mm","tag-450-750v-wire","tag-50-sq-mm","tag-6-sq-mm","tag-70-sq-mm","tag-70c-temperature-rating","tag-95-sq-mm","tag-abrasion-resistance","tag-ampacity","tag-annealed-copper-conductor","tag-black-wire","tag-blue-wire","tag-building-contractor-support","tag-building-distribution","tag-building-wire","tag-circuit-protection","tag-class-5-flexible","tag-commercial-building-wiring","tag-conduit-routing","tag-dielectric-withstand","tag-electrical-code-compliance","tag-elongation-at-break-2","tag-feichun-cable","tag-flexible-wire","tag-green-wire","tag-grounding","tag-indoor-electrical-installation","tag-indoor-wire","tag-insulation-resistance","tag-k-60227-iec-02","tag-kiv-wire","tag-ks-c-60227-3","tag-ks-c-iec-60227-3","tag-moisture-resistance","tag-product-warranty","tag-pvc-insulation","tag-quality-assurance","tag-red-wire","tag-residential-wiring","tag-single-core-wire","tag-technical-consultation","tag-temperature-cycling","tag-tensile-strength","tag-termination","tag-vinyl-insulated-wire","tag-voltage-drop","tag-white-wire","tag-wire-pulling","tag-yellow-wire","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10426","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=10426"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10426\/revisions"}],"predecessor-version":[{"id":10429,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10426\/revisions\/10429"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/10428"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=10426"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=10426"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=10426"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}