{"id":10410,"date":"2026-04-14T13:53:27","date_gmt":"2026-04-14T05:53:27","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=10410"},"modified":"2026-04-14T13:53:30","modified_gmt":"2026-04-14T05:53:30","slug":"kiv-single-core-flexible-vinyl-insulated-wire","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/kiv-single-core-flexible-vinyl-insulated-wire\/","title":{"rendered":"KIV Single-Core Flexible Vinyl Insulated Wire"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Professional Engineering for Building &amp; Electrical Installations \u2014 K 60227 IEC 02 Standard Compliance, Flexible Class 5 Stranded Copper Conductors, Polyvinyl Chloride (PVC) Insulation, Extended Conductor Sizing (1.5\u2013240 sq mm), Standard Color Identification (Black, White, Red, Green, Yellow, Blue), 70\u00b0C Temperature Rating, Optimized Flexibility for Indoor Wiring, and Specialized Applications for Professional Electrical Installations and Building Distribution Systems<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Complete Technical Reference for Electrical Installers and Engineers: Understanding KIV Single-Core Architecture, Class 5 Flexible Conductor Design, 450\/750V Electrical Performance, Polyvinyl Chloride Insulation Properties, 70\u00b0C Temperature Performance, Conductor Sizing Optimization for Building Distribution, Standard Color Coding System, Extended Conductor Range (1.5\u2013240 sq mm), Installation Best Practices for Professional Wiring, Safety and Regulatory Compliance, Quality Assurance Standards, and Integration with Building Electrical Distribution Systems.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"f0e9e5\" data-has-transparency=\"false\" style=\"--dominant-color: #f0e9e5;\" loading=\"lazy\" decoding=\"async\" width=\"744\" height=\"628\" sizes=\"auto, (max-width: 744px) 100vw, 744px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181-744x628.avif\" alt=\"\" class=\"wp-image-10411 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181-744x628.avif 744w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181-300x253.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181-768x648.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181-400x338.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181-800x675.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181-832x702.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1181.avif 848w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>KIV Single-Core Flexible Wire Family \u2014 Professional-Grade Power Distribution | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical reference for K 60227 IEC 02 (KIV) 450\/750V single-core flexible vinyl insulated wire engineered for professional electrical installations, industrial power distribution, and building wiring. Comprehensive coverage of Class 5 flexible stranded copper conductors, PVC insulation, extended conductor sizing (1.5\u2013240 sq mm), standard color identification system, 70\u00b0C temperature rating, optimized flexibility, and specialized applications for indoor building wiring and professional equipment integration.\">\n<meta name=\"keywords\" content=\"KIV wire, single-core wire, 450\/750V wire, flexible wire, vinyl insulated wire, professional wire, building wiring, electrical installation, KSC 60227\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<meta name=\"robots\" content=\"index,follow\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#0066CC;--c-link-hover:#004499;--c-accent:#0066CC;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#0066CC;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;--hl-red-glow:rgba(255,60,60,0.08)}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#6BA3FF;--c-link-hover:#8CB5FF;--c-accent:#6BA3FF;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#6BA3FF;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#6BA3FF;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;--hl-red-glow:rgba(255,60,60,0.15)}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden}.page-wrap{max-width:920px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.5rem,3.7vw,2.15rem);line-height:1.22;margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-en{font-size:.82rem;color:var(--c-tertiary);line-height:1.5;font-style:italic;margin-top:.5rem;padding-top:.5rem;border-top:1px solid var(--b-light)}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify}.body strong{font-weight:600;color:var(--c-body)}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.78rem;line-height:1.35}.tw caption{text-align:left;font-weight:600;font-size:.74rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.68rem;padding:.5rem .55rem;text-align:left;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.35rem .55rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55}.feature-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:1rem;margin:1.5rem 0 2rem}.feature-card{background:var(--bg-surface);border:1px solid var(--b-light);border-radius:4px;padding:1rem;text-align:left}.feature-card h4{font-weight:700;font-size:.92rem;margin-bottom:.3rem;color:var(--c-body)}.feature-card p{font-size:.81rem;color:var(--c-secondary);margin-bottom:0}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.3rem}.tw{font-size:.72rem}.feature-grid{grid-template-columns:1fr}}<\/style>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechArticle\",\"headline\":\"KIV Single-Core Flexible Wire Family \u2014 Professional-Grade Power Distribution\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"datePublished\":\"2026-04-14\"}<\/script>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">KIV Family<\/span>\n    <span class=\"badge\">Single-Core Wire<\/span>\n    <span class=\"badge\">450\/750V Rated<\/span>\n    <span class=\"badge\">Professional Grade<\/span>\n    <h1>KIV Single-Core Flexible Vinyl Insulated Wire<\/h1>\n    <p class=\"sub\">Professional Engineering for Building &#038; Electrical Installations \u2014 K 60227 IEC 02 Standard Compliance, Flexible Class 5 Stranded Copper Conductors, Polyvinyl Chloride (PVC) Insulation, Extended Conductor Sizing (1.5\u2013240 sq mm), Standard Color Identification (Black, White, Red, Green, Yellow, Blue), 70\u00b0C Temperature Rating, Optimized Flexibility for Indoor Wiring, and Specialized Applications for Professional Electrical Installations and Building Distribution Systems<\/p>\n    <p class=\"sub-en\">Complete Technical Reference for Electrical Installers and Engineers: Understanding KIV Single-Core Architecture, Class 5 Flexible Conductor Design, 450\/750V Electrical Performance, Polyvinyl Chloride Insulation Properties, 70\u00b0C Temperature Performance, Conductor Sizing Optimization for Building Distribution, Standard Color Coding System, Extended Conductor Range (1.5\u2013240 sq mm), Installation Best Practices for Professional Wiring, Safety and Regulatory Compliance, Quality Assurance Standards, and Integration with Building Electrical Distribution Systems.<\/p>\n    <div class=\"meta\">\n      <span>Anhui Feichun Special Cable Co., Ltd.<\/span>\n      <span>Published April 2026<\/span>\n      <span>12 min technical reference<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">KIV Single-Core Wire Architecture &#038; Design Strategy<\/a><\/li>\n      <li><a href=\"#s2\">Class 5 Flexible Stranded Conductor Design<\/a><\/li>\n      <li><a href=\"#s3\">Polyvinyl Chloride (PVC) Insulation Properties<\/a><\/li>\n      <li><a href=\"#s4\">450\/750V Voltage Rating &#038; Electrical Performance<\/a><\/li>\n      <li><a href=\"#s5\">Temperature Performance: 70\u00b0C Continuous Rating<\/a><\/li>\n      <li><a href=\"#s6\">Conductor Sizing &#038; Ampacity Optimization<\/a><\/li>\n      <li><a href=\"#s7\">Standard Color Identification System<\/a><\/li>\n      <li><a href=\"#s8\">Technical Specifications: KIV Wire Series (1.5\u2013240 sq mm)<\/a><\/li>\n      <li><a href=\"#s9\">Single-Core vs. Multi-Core Architecture<\/a><\/li>\n      <li><a href=\"#s10\">Building Wiring Applications &#038; Installation<\/a><\/li>\n      <li><a href=\"#s11\">Professional Installation &#038; Safety Protocols<\/a><\/li>\n      <li><a href=\"#s12\">Quality Assurance &#038; Testing Standards<\/a><\/li>\n      <li><a href=\"#s13\">Product Support &#038; Professional Services<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <!-- ===== S1 ===== -->\n  <section class=\"body\" id=\"s1\">\n    <h2>KIV Single-Core Wire Architecture &#038; Design Strategy<\/h2>\n\n    <p><strong>K 60227 IEC 02 (KIV) single-core flexible vinyl insulated wire<\/strong> represents the professional-grade approach to electrical building wiring and power distribution\u2014engineered for flexibility, color-coded identification, extended conductor range, and reliability in indoor electrical installations. The KIV designation (Korean standard KS C designation for vinyl insulated flexible wire) indicates specific construction combining Class 5 flexible stranded copper conductors with polyvinyl chloride (PVC) insulation optimized for professional electrical work.<\/p>\n\n    <p><strong>Fundamental Design Philosophy:<\/strong> Unlike multi-core cords which consolidate multiple circuits into single assemblies, KIV single-core wires are designed as individual conductors enabling flexible circuit design in building electrical distribution systems. Electricians can select individual wires in appropriate colors and sizes, combining them according to specific installation requirements. This modular approach enables optimal cost and performance optimization for each application.<\/p>\n\n    <p><strong>Core Voltage Rating: 450\/750V:<\/strong> The 450\/750V rating indicates higher voltage capacity than consumer cords (300\/500V)\u2014appropriate for professional building wiring where 380\u2013415V three-phase distribution or 230V single-phase supplies are standard. The 750V maximum overvoltage tolerance provides safety margin against transient surges and switching transients characteristic of professional electrical systems.<\/p>\n\n    <p><strong>Extended Conductor Range:<\/strong> KIV wires are available in conductor sizes 1.5\u2013240 sq mm\u2014substantially broader range than consumer cords. This extended sizing enables optimal specification from small auxiliary circuits (1.5 sq mm) through large primary power feeders (240 sq mm) within single product family.<\/p>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">KIV Wire Selection: Professional Installation Best Practice<\/div>\n      <p>Professional electrical installers recognize KIV wires as the optimized solution for building electrical systems. Standardized color coding, extended conductor range, and recognized international standards ensure regulatory approval and safety across professional installations. Feichun&#8217;s KIV family provides consistent quality enabling reliable long-term performance in demanding building environments.<\/p>\n    <\/div>\n  <\/section>\n\n  <!-- ===== S2 ===== -->\n  <section class=\"body\" id=\"s2\">\n    <h2>Class 5 Flexible Stranded Conductor Design<\/h2>\n\n    <p><strong>Class 5 Conductor Specification:<\/strong> KIV wires employ Class 5 stranded conductors per IEC 60228 standard\u2014the finest standard construction for flexible wiring applications. Class 5 conductors employ numerous thin copper wires (typically 7, 19, 37, or 61 individual strands depending on total conductor size) twisted together in precise geometric pattern providing maximum flexibility.<\/p>\n\n    <p><strong>Flexibility Benefits:<\/strong> Multi-strand Class 5 construction enables smooth bending and coiling without conductor fracture. Each thin individual strand distributes stress uniformly\u2014no single wire bears excessive load. This distributed stress architecture enables thousands of bend cycles without conductor degradation, far exceeding performance of rigid single-strand conductors.<\/p>\n\n    <p><strong>Copper Grade &#038; Purity:<\/strong> KIV conductors employ high-purity copper (99.95% minimum) in annealed (soft) condition. Annealing eliminates work-hardening brittleness, maintaining consistent flexibility throughout conductor life. Unlike half-hard copper (which maintains shape but sacrifices flexibility), annealed copper enables smooth bending even after extended storage and handling.<\/p>\n\n    <p><strong>Tinned vs. Bare Copper Options:<\/strong> KIV wires available in both bare copper and tin-coated options. Bare copper provides lowest cost and maximum electrical conductivity. Tin-coated copper (typically 0.1\u20130.2 mm coating thickness) provides superior corrosion resistance\u2014essential for humid environments or installations exposed to atmospheric contamination. Tin coating also improves termination reliability by preventing oxidation at connection points.<\/p>\n\n    <p><strong>Strand Count Optimization:<\/strong> Small conductors (1.5\u20136 sq mm) employ 7-strand construction balancing flexibility and manufacturing efficiency. Medium conductors (10\u201335 sq mm) employ 19 or 37-strand patterns. Large conductors (50\u2013240 sq mm) employ 37, 61, or specialized multi-layer strand arrangements maximizing flexibility while maintaining structural integrity.<\/p>\n\n  <\/section>\n\n  <!-- ===== S3 ===== -->\n  <section class=\"body\" id=\"s3\">\n    <h2>Polyvinyl Chloride (PVC) Insulation Properties<\/h2>\n\n    <p><strong>PVC Material Characteristics:<\/strong> Polyvinyl chloride (PVC) insulation provides excellent combination of electrical performance, mechanical durability, and cost-effectiveness appropriate for professional building wiring. PVC material offers high dielectric strength (16\u201318 kV\/mm), stable insulation resistance across temperature range, and superior mechanical durability compared to consumer-grade materials.<\/p>\n\n    <p><strong>Insulation Thickness Optimization:<\/strong> KIV wire insulation thickness varies with conductor size\u20141.5 sq mm conductors employ 0.7 mm insulation; medium conductors employ 1.0\u20131.4 mm; large conductors employ 1.6\u20132.2 mm. This graduated approach balances electrical stress distribution (thicker insulation for larger conductors) against wire diameter and cost considerations.<\/p>\n\n    <p><strong>Electrical Performance:<\/strong> PVC insulation provides consistent dielectric properties across 450\/750V operating range. Test voltage of 3,500V (approximately 4.7\u00d7 operating maximum) validates substantial safety margin. Minimum insulation resistance of 250\u2013450 M\u03a9\u00b7km (depending on conductor size) ensures electrical integrity throughout service life.<\/p>\n\n    <p><strong>Mechanical Properties:<\/strong> PVC maintains excellent flexibility when properly formulated with plasticizers\u2014bending repeatedly without insulation cracking, withstanding thousands of flex cycles without degradation. However, PVC does stiffen at low temperatures (below \u221210\u00b0C) limiting cold climate performance compared to specialized rubber materials.<\/p>\n\n    <p><strong>Environmental Resistance:<\/strong> PVC provides good moisture resistance (preventing water absorption that degrades insulation), inherent flame retardance (self-extinguishing without open flame), and chemical resistance to common indoor building environment contaminants. These properties extend wire service life in typical indoor installations.<\/p>\n\n  <\/section>\n\n  <!-- ===== S4 ===== -->\n  <section class=\"body\" id=\"s4\">\n    <h2>450\/750V Voltage Rating &#038; Electrical Performance<\/h2>\n\n    <p><strong>Dual Voltage Rating Nomenclature:<\/strong> The 450\/750V rating indicates 450V nominal continuous operating voltage with 750V maximum transient overvoltage tolerance. This rating accommodates professional building electrical systems where three-phase 380\u2013415V supplies or single-phase 230V circuits are standard. The 300V overvoltage margin (from 450V nominal to 750V maximum) provides industry-standard protection against electrical transient events.<\/p>\n\n    <p><strong>Safety Margin Engineering:<\/strong> The voltage margin represents professional-grade safety factor. Motor starting surges (typically 1.3\u20131.5\u00d7 nominal voltage) remain safely below the 750V threshold. Lightning impulse transients and switching transients also remain within margin. Test voltage of 3,500V confirms substantial safety factor built into wire design.<\/p>\n\n    <p><strong>Conductor Sizing Guidance by Voltage:<\/strong> Professional electricians size conductors based on actual circuit current requirements and voltage drop limits. At 450V three-phase power, voltage drop should not exceed 2\u20133% for branch circuits (approximately 9\u201313.5V drop across typical circuit). Proper conductor sizing ensures acceptable voltage drop while optimizing installation cost.<\/p>\n\n    <p><strong>Dielectric Performance Across Size Range:<\/strong> From smallest (1.5 sq mm) through largest (240 sq mm) conductors, PVC insulation maintains consistent dielectric properties. The insulation provides electrical breakdown resistance exceeding 11.4\u201317.6 kV before catastrophic failure\u2014far exceeding the 750V operating maximum.<\/p>\n\n  <\/section>\n\n  <!-- ===== S5 ===== -->\n  <section class=\"body\" id=\"s5\">\n    <h2>Temperature Performance: 70\u00b0C Continuous Rating<\/h2>\n\n    <p><strong>70\u00b0C Continuous Operating Temperature:<\/strong> KIV wires maintain full operational performance at maximum 70\u00b0C (158\u00b0F) continuous conductor temperature\u2014standard rating for professional building wiring applications. This 70\u00b0C rating accommodates typical indoor electrical distribution where sustained high-temperature operation is not anticipated.<\/p>\n\n    <p><strong>Ampacity Derating at Temperature:<\/strong> While PVC insulation maintains acceptable electrical properties at 70\u00b0C, conductor ampacity (current capacity) must be derated at elevated temperatures. At sustained 70\u00b0C operation, ampacity should be reduced approximately 15\u201320% compared to 40\u00b0C baseline to manage heat dissipation and ensure safe long-term operation.<\/p>\n\n    <p><strong>Building Installation Considerations:<\/strong> Building wiring installed in conduit or cable trays (enclosed spaces restricting heat dissipation) must accommodate higher ambient temperatures than exposed routing. Installers must verify adequate heat dissipation preventing sustained conductor temperatures exceeding 70\u00b0C maximum rating.<\/p>\n\n    <p><strong>Cold Climate Performance Limitations:<\/strong> PVC stiffens at low temperatures (below \u221210\u00b0C), limiting performance in unheated spaces or winter outdoor installations. For cold climate buildings or equipment, specialized wires with EPR or silicone insulation provide superior low-temperature performance.<\/p>\n\n    <p><strong>Thermal Cycling Resilience:<\/strong> Building wiring experiences seasonal temperature cycling. PVC withstands moderate thermal cycling\u2014testing demonstrates KIV wires maintain electrical integrity following 10+ cycles spanning 0\u00b0C to 70\u00b0C. Extended cycling beyond 20+ cycles may cause progressive insulation hardening.<\/p>\n\n  <\/section>\n\n  <!-- ===== S6 ===== -->\n  <section class=\"body\" id=\"s6\">\n    <h2>Conductor Sizing &#038; Ampacity Optimization<\/h2>\n\n    <p><strong>Extended Conductor Range (1.5\u2013240 sq mm):<\/strong> KIV wires are available in standardized conductor sizes: 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, and 240 sq mm. This extended range enables optimal specification for every circuit requirement from small auxiliary circuits through large primary power feeders.<\/p>\n\n    <p><strong>Small Conductor Sizing (1.5\u20136 sq mm):<\/strong> Used for low-power circuits, lighting circuits, and control circuits. Size 1.5 sq mm rated approximately 10\u201316 amperes; size 6 sq mm rated approximately 30\u201340 amperes. These small conductors minimize wire bulk in dense wiring environments while providing adequate current capacity for modest loads.<\/p>\n\n    <p><strong>Medium Conductor Sizing (10\u201335 sq mm):<\/strong> Standard sizing for branch circuits and sub-distribution circuits. Size 10 sq mm rated approximately 50 amperes; size 35 sq mm rated approximately 150+ amperes. Medium conductors accommodate typical commercial equipment loads with acceptable voltage drop over moderate distances.<\/p>\n\n    <p><strong>Large Conductor Sizing (50\u2013120 sq mm):<\/strong> Heavy-duty sizing for main distribution circuits and equipment primary feeders. Size 50 sq mm rated approximately 200 amperes; size 120 sq mm rated approximately 400+ amperes. Large conductors minimize voltage drop over extended circuit runs and accommodate substantial loads requiring high current capacity.<\/p>\n\n    <p><strong>Maximum Conductor Sizing (150\u2013240 sq mm):<\/strong> Ultra-heavy-duty sizing for main electrical feeders and primary power distribution. Size 240 sq mm rated approximately 600+ amperes at 40\u00b0C. These maximum sizes accommodate entire facility electrical distribution where single main feeder supplies all building power.<\/p>\n\n    <p><strong>Voltage Drop Calculation:<\/strong> Professional installers calculate voltage drop: VD = 2 \u00d7 L \u00d7 I \u00d7 R \u00f7 1000, where L = circuit length (meters), I = circuit current (amperes), R = conductor resistance (\u03a9\/km from technical specifications). Voltage drop should not exceed 2\u20133% for final circuits ensuring adequate voltage at connected equipment.<\/p>\n\n  <\/section>\n\n  <!-- ===== S7 ===== -->\n  <section class=\"body\" id=\"s7\">\n    <h2>Standard Color Identification System<\/h2>\n\n    <p><strong>Standardized Color Coding:<\/strong> KIV wires employ standardized colors enabling rapid visual identification. These color standards (per IEC 60227-3 and equivalent national standards) ensure consistency enabling technicians worldwide to identify wire functions correctly\u2014critical for electrical safety.<\/p>\n\n    <p><strong>Standard Color Selection:<\/strong> Six standard colors available: Black, White, Red, Green, Yellow, and Blue. Professional installations employ these colors systematically to identify different circuits, phases, or functional roles within electrical distribution system.<\/p>\n\n    <p><strong>Common Color Usage Conventions:<\/strong><\/p>\n\n    <p><strong>Black Wire:<\/strong> Typically designates phase conductor in single-phase circuits or any phase conductor in three-phase systems. Can also identify neutral or alternative functions in specialized systems.<\/p>\n\n    <p><strong>White Wire:<\/strong> Typically designates neutral conductor in AC systems. International standards often restrict white to neutral function only, distinguishing from phase conductors.<\/p>\n\n    <p><strong>Red Wire:<\/strong> Often designates second phase in three-phase systems or alternative phase in specialized circuits. Some standards designate red for secondary or switched circuits.<\/p>\n\n    <p><strong>Green Wire:<\/strong> Reserved for protective earth grounding conductor in some standards. Prevents dangerous mistaken connection to active circuits.<\/p>\n\n    <p><strong>Yellow Wire:<\/strong> Often designates third phase in three-phase systems or alternative circuit function. Some standards combine yellow with green (green\/yellow striped) specifically for earth grounding.<\/p>\n\n    <p><strong>Blue Wire:<\/strong> Alternative designation for neutral, alternative phase, or specialized circuit function depending on installation requirements and local standards.<\/p>\n\n    <p><strong>Color Coding Safety Importance:<\/strong> Standardized colors prevent dangerous connection errors that could cause equipment malfunction or electrocution hazard. Electricians depend on color coding for rapid identification\u2014color mistakes represent serious safety violations.<\/p>\n\n  <\/section>\n\n  <!-- ===== S8 ===== -->\n  <section class=\"body\" id=\"s8\">\n    <h2>Technical Specifications: KIV Wire Series (1.5\u2013240 sq mm)<\/h2>\n\n    <div class=\"tw\">\n      <table>\n        <caption>K 60227 IEC 02 (KIV) 450\/750V Single-Core Flexible Wire \u2014 Complete Technical Specifications<\/caption>\n        <thead><tr><th>Size (sq mm)<\/th><th>Max Wire Diameter (mm)<\/th><th>Insulation Thickness (mm)<\/th><th>Outer Diameter (mm)<\/th><th>Weight (kg\/km)<\/th><th>Conductor Resistance @ 20\u00b0C (\u03a9\/km)<\/th><th>Insulation Resistance @ 70\u00b0C (M\u03a9\u00b7km)<\/th><th>Test Voltage (V\/5min)<\/th><th>Packing (m)<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>1.5<\/td><td>1.6<\/td><td>0.7<\/td><td>2.8\u20133.4<\/td><td>30<\/td><td>13.3\u201313.7<\/td><td>0.010<\/td><td>3,500<\/td><td>200<\/td><\/tr>\n          <tr><td>2.5<\/td><td>2.1<\/td><td>0.8<\/td><td>3.4\u20134.1<\/td><td>40<\/td><td>7.98\u20138.21<\/td><td>0.009<\/td><td>3,500<\/td><td>200<\/td><\/tr>\n          <tr><td>4<\/td><td>2.63<\/td><td>0.8<\/td><td>3.9\u20134.8<\/td><td>50<\/td><td>4.95\u20135.09<\/td><td>0.007<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>6<\/td><td>3.6<\/td><td>0.8<\/td><td>4.4\u20135.3<\/td><td>80<\/td><td>3.30\u20133.39<\/td><td>0.006<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>10<\/td><td>4.8<\/td><td>1.0<\/td><td>5.7\u20136.8<\/td><td>130<\/td><td>1.91\u20131.95<\/td><td>0.0056<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>16<\/td><td>6.0<\/td><td>1.0<\/td><td>6.7\u20138.1<\/td><td>180<\/td><td>1.21\u20131.24<\/td><td>0.0046<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>25<\/td><td>7.4<\/td><td>1.2<\/td><td>8.4\u201310.2<\/td><td>280<\/td><td>0.780\u20130.795<\/td><td>0.0044<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>35<\/td><td>8.7<\/td><td>1.2<\/td><td>9.7\u201311.7<\/td><td>370<\/td><td>0.554\u20130.565<\/td><td>0.0038<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>50<\/td><td>10.4<\/td><td>1.4<\/td><td>11.5\u201313.9<\/td><td>500<\/td><td>0.386\u20130.393<\/td><td>0.0037<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>70<\/td><td>12.5<\/td><td>1.4<\/td><td>13.2\u201316.0<\/td><td>700<\/td><td>0.272\u20130.277<\/td><td>0.0032<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>95<\/td><td>14.5<\/td><td>1.6<\/td><td>15.1\u201318.2<\/td><td>970<\/td><td>0.206\u20130.210<\/td><td>0.0032<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>120<\/td><td>16.2<\/td><td>1.6<\/td><td>16.7\u201320.2<\/td><td>1,200<\/td><td>0.161\u20130.164<\/td><td>0.0029<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>150<\/td><td>18.2<\/td><td>1.8<\/td><td>18.6\u201322.5<\/td><td>1,490<\/td><td>0.129\u20130.132<\/td><td>0.0029<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>185<\/td><td>20.2<\/td><td>2.0<\/td><td>20.6\u201324.9<\/td><td>1,850<\/td><td>0.106\u20130.108<\/td><td>0.0029<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td>240<\/td><td>23.3<\/td><td>2.2<\/td><td>23.5\u201328.4<\/td><td>2,440<\/td><td>0.0801\u20130.0817<\/td><td>0.0028<\/td><td>3,500<\/td><td>100<\/td><\/tr>\n          <tr><td colspan=\"9\" style=\"text-align:center;font-weight:700;background:var(--bg-th);color:var(--c-inverse)\">All wires conform to K 60227 IEC 02 (KIV) standard. Class 5 flexible stranded copper conductors. Outer diameter shown as minimum\u2013maximum range. Available in Bare Copper or Tin-Coated Copper. Standard colors: Black, White, Red, Green, Yellow, Blue.<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S9 ===== -->\n  <section class=\"body\" id=\"s9\">\n    <h2>Single-Core vs. Multi-Core Architecture<\/h2>\n\n    <p><strong>Single-Core Design Advantage:<\/strong> KIV single-core wires provide maximum flexibility in circuit design\u2014electricians select individual wires in appropriate colors and sizes according to specific installation requirements. This modular approach enables optimal cost by avoiding oversized multi-core cables and enables custom circuit arrangements matching actual building needs.<\/p>\n\n    <p><strong>Installation Flexibility:<\/strong> Single-core wires enable efficient installation in conduit or cable trays where multiple separate circuits share common routing infrastructure. Different circuits can employ different wire sizes (large feeder circuits alongside small control circuits in same conduit)\u2014difficult or impossible with fixed multi-core designs.<\/p>\n\n    <p><strong>Termination Simplicity:<\/strong> Each single-core wire terminates independently\u2014no complex multi-pin connectors required. Standard crimped lugs or push-in terminals accommodate connections efficiently. Maintenance and troubleshooting simplified by independent circuit testing.<\/p>\n\n    <p><strong>Comparison to Multi-Core Cords:<\/strong> Multi-core cords (like VCTF previously discussed) consolidate multiple circuits into single assemblies\u2014optimal for portable equipment where circuits move together. Single-core wires suit fixed building installations where circuits may have different routing paths, termination locations, or maintenance requirements.<\/p>\n\n  <\/section>\n\n  <!-- ===== S10 ===== -->\n  <section class=\"body\" id=\"s10\">\n    <h2>Building Wiring Applications &#038; Installation<\/h2>\n\n    <p><strong>Indoor Building Distribution:<\/strong> KIV wires serve as standard for indoor electrical distribution in residential, commercial, and industrial buildings. Typically routed in conduit, cable trays, or through walls connecting circuit breaker panels to outlets, switches, and equipment.<\/p>\n\n    <p><strong>Three-Phase Power Distribution:<\/strong> Three-phase 380\u2013415V systems employ three KIV wires (one per phase) plus neutral and protective earth grounding wires. Professional installers use standardized colors: Black (Phase 1), Red (Phase 2), Yellow (Phase 3), White (Neutral), Green\/Yellow (Earth). Three-phase sizing enables efficient distribution of large electrical loads.<\/p>\n\n    <p><strong>Sub-Distribution Circuits:<\/strong> KIV wires also serve in sub-distribution circuits supplying individual building areas\u2014lighting circuits, equipment power circuits, power outlet circuits. Each circuit employs appropriately sized wires minimizing both cost and voltage drop.<\/p>\n\n    <p><strong>Equipment Connections:<\/strong> Motors, transformers, switchgear, and other electrical equipment typically connect using KIV wires appropriately sized for equipment current requirements and voltage.<\/p>\n\n    <div class=\"note green\">\n      <div class=\"nt\">Professional Installation Best Practice<\/div>\n      <p>Building electricians should design circuits systematically, calculating actual load requirements and voltage drop, then specifying KIV wire size based on professional engineering standards. Oversizing wires increases installation cost and material consumption; undersizing creates excessive voltage drop and safety risk. Feichun engineers provide professional sizing consultation at Tech@feichuncables.com.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S11 ===== -->\n  <section class=\"body\" id=\"s11\">\n    <h2>Professional Installation &#038; Safety Protocols<\/h2>\n\n    <p><strong>Proper Conduit &#038; Cable Tray Routing:<\/strong> KIV wires should be routed through protective conduit or cable trays preventing mechanical damage from construction activities, sharp edges, or environmental hazards. Conduit also simplifies future maintenance and wire replacement.<\/p>\n\n    <p><strong>Bend Radius Compliance:<\/strong> Minimum bend radius should be approximately 10\u201315\u00d7 wire outer diameter. Sharper bends create stress concentration and potential insulation cracking. Professional installations employ proper bend radius throughout routing.<\/p>\n\n    <p><strong>Termination Standards:<\/strong> All wire terminations employ properly sized crimped lugs, push-in terminals, or screw terminals appropriate for wire size and material (copper or tinned). Loose or corroded terminations create fire hazard and must be corrected immediately.<\/p>\n\n    <p><strong>Grounding Connection Verification:<\/strong> Protective earth grounding conductor must be verified continuous before energizing circuit. Proper grounding provides personal electrocution protection and equipment fault protection.<\/p>\n\n    <p><strong>Cable Fill Compliance:<\/strong> Conduit should not exceed 40% fill capacity (by cross-sectional area) to enable adequate cooling and future wire addition without damage to existing insulation.<\/p>\n\n    <p><strong>Circuit Protection &#038; Sizing:<\/strong> Each circuit protected by appropriately sized breaker or fuse rating not exceeding wire ampacity. Oversized protection allows excessive current\u2014creating insulation damage before protection operates.<\/p>\n\n  <\/section>\n\n  <!-- ===== S12 ===== -->\n  <section class=\"body\" id=\"s12\">\n    <h2>Quality Assurance &#038; Testing Standards<\/h2>\n\n    <p><strong>Production Quality Testing:<\/strong> Every KIV wire batch undergoes comprehensive testing prior to shipment:<\/p>\n\n    <p><strong>Electrical Testing:<\/strong> Dielectric withstand (3,500V for 5 minutes), insulation resistance verification (minimum 250\u2013450 M\u03a9\u00b7km depending on size at 70\u00b0C), conductor continuity testing confirming no internal breaks.<\/p>\n\n    <p><strong>Mechanical Testing:<\/strong> Tensile strength validation, elongation-at-break testing (minimum 200% for PVC), bend-cycle testing (minimum 1,000+ cycles depending on size), insulation puncture resistance.<\/p>\n\n    <p><strong>Environmental Testing:<\/strong> Flame retardance testing (self-extinguishing standards), UV aging resistance (100+ hours), humidity resistance, temperature cycling (\u22125\u00b0C to +70\u00b0C, 10+ cycles).<\/p>\n\n    <p><strong>Standards Compliance:<\/strong> All KIV wires conform to K 60227 IEC 02 standard (Korean designation equivalent to IEC 60227-3). Testing by accredited laboratories with complete Certificate of Conformance provided with each batch.<\/p>\n\n  <\/section>\n\n  <!-- ===== S13 ===== -->\n  <section class=\"body\" id=\"s13\">\n    <h2>Product Support &#038; Professional Services<\/h2>\n\n    <p><strong>Standard Range Availability:<\/strong> Complete KIV wire range (1.5\u2013240 sq mm, all standard colors) immediately available from inventory or standard manufacturing (1\u20133 weeks lead time).<\/p>\n\n    <p><strong>Custom Services:<\/strong> Tin-coating options for corrosion-prone environments, custom colors for specialized applications, pre-cut lengths with pre-terminated lugs for standardized circuits.<\/p>\n\n    <p><strong>Emergency Production:<\/strong> Express manufacturing (1 week) available for urgent requirements. International shipping to all major markets.<\/p>\n\n    <p><strong>Technical Engineering Consultation:<\/strong> Feichun engineers provide professional support including circuit load analysis, conductor sizing calculations, installation planning, and on-site engineering consultation for complex projects. Contact Tech@feichuncables.com for professional consultation.<\/p>\n\n    <p><strong>Warranty &#038; Quality Guarantee:<\/strong> KIV wires backed by comprehensive warranty covering manufacturing defects and material failure. Extended warranty available for specialized applications and long-term building installations.<\/p>\n\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Anhui Feichun Special Cable Co., Ltd. \u2014 KIV Professional Wire Specialists<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\"><span class=\"lb\">KIV Wire Selection &#038; Sizing<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Building Electrical Engineering<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Professional Installation Consultation<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">24\/7 Emergency Support<\/span>+86 138 5608 5607<\/div>\n      <div class=\"ci\"><span class=\"lb\">Technical WhatsApp &#038; WeChat<\/span>+86 138 5512 3218<\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>This comprehensive technical reference covers K 60227 IEC 02 (KIV) 450\/750V single-core flexible vinyl insulated wire families engineered for professional building electrical distribution and installation. Complete coverage of Class 5 flexible stranded copper conductor design, polyvinyl chloride insulation properties, 450\/750V electrical performance characteristics, 70\u00b0C continuous temperature rating, extended conductor sizing (1.5\u2013240 sq mm), standard color identification system (Black, White, Red, Green, Yellow, Blue), flexible wiring architecture for indoor distribution systems, advanced installation protocols, professional maintenance strategies, comprehensive quality assurance systems, and integration with building electrical infrastructure. All wires conform to K 60227 IEC 02 (Korean Standard equivalent to IEC 60227-3 International Standard) with recognized professional-grade performance suitable for demanding building electrical applications.<\/p>\n    <p style=\"margin-top:.5rem;\">\u00a9 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.<\/p>\n  <\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"K 60227 IEC 02 (KIV) single-core flexible vinyl insulated wire represents the professional-grade approach to electrical building wiring and power distribution\u2014engineered for flexibility, color-coded identification, extended conductor range, and reliability in indoor electrical installations. The KIV designation (Korean standard KS C designation for vinyl insulated flexible wire) indicates specific construction combining Class 5 flexible stranded copper conductors with polyvinyl chloride (PVC) insulation optimized for professional electrical work.\nFundamental Design Philosophy: Unlike multi-core cords which consolidate multiple circuits into single assemblies, KIV single-core wires are designed as individual conductors enabling flexible circuit design in building electrical distribution systems. Electricians can select individual wires in appropriate colors and sizes, combining them according to specific installation requirements. This modular approach enables optimal cost and performance optimization for each application.\nCore Voltage Rating: 450\/750V: The 450\/750V rating indicates higher voltage capacity than consumer cords (300\/500V)\u2014appropriate for professional building wiring where 380\u2013415V three-phase distribution or 230V single-phase supplies are standard. The 750V maximum overvoltage tolerance provides safety margin against transient surges and switching transients characteristic of professional electrical systems.\nExtended Conductor Range: KIV wires are available in conductor sizes 1.5\u2013240 sq mm\u2014substantially broader range than consumer cords. This extended sizing enables optimal specification from small auxiliary circuits (1.5 sq mm) through large primary power feeders (240 sq mm) within single product family.","protected":false},"author":1,"featured_media":10411,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[464,1,56,27157],"tags":[16,17],"class_list":["post-10410","post","type-post","status-publish","format-standard","has-post-thumbnail","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","category-uncategorized","category-reeling-cable","category-27157","tag-din-vde-0250","tag-reeling-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10410","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=10410"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10410\/revisions"}],"predecessor-version":[{"id":10413,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10410\/revisions\/10413"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/10411"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=10410"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=10410"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=10410"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}