{"id":10357,"date":"2026-04-13T23:32:00","date_gmt":"2026-04-13T15:32:00","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=10357"},"modified":"2026-04-13T23:32:03","modified_gmt":"2026-04-13T15:32:03","slug":"pnct-f-flat-type-cables-cable-specification-system","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/pnct-f-flat-type-cables-cable-specification-system\/","title":{"rendered":"PNCT-F Flat Type Cables &#038; Cable Specification System"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Complete Technical Guide to Flat-Profile Port Crane Cables and Comprehensive Cable Type Designation System \u2014 Understanding Cable Variants (HT, FC, SC), Reinforcement Options (R), Shielding (S), and Proper Cable Specification and Ordering Procedures<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Professional Reference for Terminal Engineers and Procurement Specialists: Cable Type Selection Matrix, Designation Codes, Specification Parameters, Complete Technical Data for All Cable Variants, and Step-by-Step Guide to Specifying the Correct Cable for Port Cranes, Festoon Systems, Ship Unloaders, and Marine Terminal Applications.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"eceaea\" data-has-transparency=\"false\" style=\"--dominant-color: #eceaea;\" loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"530\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1168.avif\" alt=\"\" class=\"wp-image-10358 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1168.avif 850w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1168-300x187.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1168-768x479.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1168-400x249.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1168-800x499.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1168-832x519.avif 832w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>PNCT-F Flat Type Port Crane Cables &#038; Cable Specification System \u2014 Complete Guide to Cable Selection and Designation | FeiChun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical guide to PNCT-F flat type port crane cables and comprehensive cable type designation system. Understand cable variants (HT, FC, SC), specifications (R-Reinforced, F-Flat, S-Shielded), conductor configurations, and proper cable ordering procedures for marine terminals and port equipment applications.\">\n<meta name=\"keywords\" content=\"PNCT-F cable, flat type cable, port crane cable, cable designation, cable specification system, HT cable, FC cable, SC cable, cable ordering, marine cable, festoon cable, cable type selection\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<meta name=\"robots\" content=\"index,follow\">\n<meta property=\"og:title\" content=\"PNCT-F Flat Type Cables &#038; Cable Specification System \u2014 Complete Technical Reference\">\n<meta property=\"og:type\" content=\"article\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#0066CC;--c-link-hover:#004499;--c-accent:#0066CC;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#0066CC;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;--hl-red-glow:rgba(255,60,60,0.08)}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#6BA3FF;--c-link-hover:#8CB5FF;--c-accent:#6BA3FF;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#6BA3FF;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#6BA3FF;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;--hl-red-glow:rgba(255,60,60,0.15)}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.5rem,3.7vw,2.15rem);line-height:1.22;margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-en{font-size:.82rem;color:var(--c-tertiary);line-height:1.5;font-style:italic;margin-top:.5rem;padding-top:.5rem;border-top:1px solid var(--b-light)}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify}.body strong{font-weight:600;color:var(--c-body)}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.83rem;line-height:1.45}.tw caption{text-align:left;font-weight:600;font-size:.76rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.72rem;padding:.55rem .7rem;text-align:left;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.45rem .7rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note.red{background:var(--hl-red-glow);border-left-color:#C0392B}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--b-rule)}.refs h2{font-size:1.08rem;margin-bottom:.9rem}.rl{list-style:none;counter-reset:rf;padding:0}.rl li{counter-increment:rf;font-size:.79rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5}.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.74rem}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55}.tm{font-size:.65rem;vertical-align:super;font-weight:700;color:var(--c-accent);letter-spacing:.02em}code.cd{font-family:'IBM Plex Mono',monospace;font-size:.92em;background:var(--bg-code);padding:.15em .4em;border-radius:3px;font-weight:500;color:var(--c-body);letter-spacing:.02em}.order-box{background:var(--bg-surface);border-left:4px solid var(--c-accent);border:1px solid var(--b-light);border-left:4px solid var(--c-accent);border-radius:4px;padding:1.2rem;margin:1.5rem 0;font-size:.85rem}.order-box h4{font-weight:700;margin-bottom:.5rem}.order-box .example{background:var(--bg-code);padding:.6rem;border-radius:3px;font-family:'IBM Plex Mono',monospace;margin-top:.5rem;font-size:.78rem;word-break:break-all}.grid-2{display:grid;grid-template-columns:1fr 1fr;gap:1rem;margin:1.5rem 0}.grid-2 > div{background:var(--bg-surface);border:1px solid var(--b-light);border-radius:4px;padding:1rem}.grid-2 h4{font-weight:700;font-size:.95rem;margin-bottom:.5rem;border-bottom:2px solid var(--b-accent);padding-bottom:.3rem}.grid-2 ul{list-style:none;padding:0;font-size:.82rem}.grid-2 li{margin-bottom:.3rem;padding-left:1rem;position:relative;color:var(--c-secondary)}.grid-2 li::before{content:\"\u25b8\";position:absolute;left:0}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.3rem}.tw{font-size:.76rem}.grid-2{grid-template-columns:1fr}}<\/style>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechArticle\",\"headline\":\"PNCT-F Flat Type Port Crane Cables & Cable Specification System \u2014 Complete Technical Reference\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"datePublished\":\"2026-04-13\"}<\/script>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">PNCT-F Standard<\/span>\n    <span class=\"badge\">Flat Type Cable<\/span>\n    <span class=\"badge\">Cable Designation System<\/span>\n    <span class=\"badge\">Specification Guide<\/span>\n    <h1>PNCT-F Flat Type Cables &#038; Cable Specification System<\/h1>\n    <p class=\"sub\">Complete Technical Guide to Flat-Profile Port Crane Cables and Comprehensive Cable Type Designation System \u2014 Understanding Cable Variants (HT, FC, SC), Reinforcement Options (R), Shielding (S), and Proper Cable Specification and Ordering Procedures<\/p>\n    <p class=\"sub-en\">Professional Reference for Terminal Engineers and Procurement Specialists: Cable Type Selection Matrix, Designation Codes, Specification Parameters, Complete Technical Data for All Cable Variants, and Step-by-Step Guide to Specifying the Correct Cable for Port Cranes, Festoon Systems, Ship Unloaders, and Marine Terminal Applications.<\/p>\n    <div class=\"meta\">\n      <span>Anhui Feichun Special Cable Co., Ltd.<\/span>\n      <span>Published April 2026<\/span>\n      <span>13 min technical reference<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">PNCT-F Flat Type Cable: Design Advantages<\/a><\/li>\n      <li><a href=\"#s2\">Cable Type Designation System Overview<\/a><\/li>\n      <li><a href=\"#s3\">Cable Type Categories: HT, FC, SC Explained<\/a><\/li>\n      <li><a href=\"#s4\">Specification Modifiers: -R (Reinforced), (S) (Shielded), -F (Flat)<\/a><\/li>\n      <li><a href=\"#s5\">Conductor Configurations: 2-Core, 3-Core, 4-Core<\/a><\/li>\n      <li><a href=\"#s6\">Cable Specification Parameters<\/a><\/li>\n      <li><a href=\"#s7\">How to Specify a Cable: Complete Checklist<\/a><\/li>\n      <li><a href=\"#s8\">Technical Data: PNCT-F Complete Specifications<\/a><\/li>\n      <li><a href=\"#s9\">Common Specification Errors &#038; Solutions<\/a><\/li>\n      <li><a href=\"#s10\">Selection Guide: Which Cable Type for Your Application<\/a><\/li>\n      <li><a href=\"#s11\">Quality Assurance &#038; Certification<\/a><\/li>\n      <li><a href=\"#s12\">References &#038; Standards<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <!-- ===== S1 ===== -->\n  <section class=\"body\" id=\"s1\">\n    <h2>PNCT-F Flat Type Cable: Design Advantages<\/h2>\n\n    <p>The <strong>PNCT-F designation<\/strong> identifies cables with a <strong>flat profile<\/strong> cross-section, as opposed to the standard round profile. While round cables are universal and flexible, flat cables offer specific advantages for certain port crane applications:<\/p>\n\n    <p><strong>Compact Storage and Handling:<\/strong> Flat cables pack more efficiently on drums and spools. A flat cable occupies approximately 15\u201320% less volume than a round cable of equivalent conductor area, reducing storage footprint and shipping volume.<\/p>\n\n    <p><strong>Improved Thermal Dissipation:<\/strong> The flat geometry increases surface area relative to volume, enabling better heat dissipation from the conductor. In high-current applications (large hoist motors), flat cables run cooler than round cables, reducing insulation aging and extending service life.<\/p>\n\n    <p><strong>Easier Cable Management:<\/strong> Flat cables lay flatter in cable troughs and festoon routes, reducing twisting and tangling. This property is particularly valuable in complex multi-cable installations where space is constrained.<\/p>\n\n    <p><strong>Lower Profile Aesthetics:<\/strong> For applications where cable profile affects equipment appearance or port terminal aesthetics, flat cables provide a lower-profile alternative.<\/p>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">When Round vs. Flat: Selection Criteria<\/div>\n      <p>Round cables are the default choice for 90% of port crane applications due to their superior bending flexibility and universal compatibility with standard sheaves and fairleads. Flat cables are specified primarily in high-current applications (where thermal benefits justify the cost premium) or in installations where space constraints make flat geometry necessary. When in doubt, specify round (standard PNCT); specify flat (PNCT-F) only when specific engineering requirements justify the cost and complexity.<\/p>\n    <\/div>\n  <\/section>\n\n  <!-- ===== S2 ===== -->\n  <section class=\"body\" id=\"s2\">\n    <h2>Cable Type Designation System Overview<\/h2>\n\n    <p>Feichun&#8217;s cable designation system uses a hierarchical, modular approach where each component of the designation carries specific meaning:<\/p>\n\n    <div class=\"order-box\">\n      <h4>Standard Cable Designation Format<\/h4>\n      <p><strong>Prefix (Optional) &#8211; Base Type &#8211; Modifiers &#8211; Sheath Material Code<\/strong><\/p>\n      <div class=\"example\">Example: FC-PNCT-R  or  HT-PNCT(S)  or  SC-PNCT-F<\/div>\n      <p style=\"margin-top:.8rem;\"><strong>Prefix:<\/strong> FC (Festoon), HT (High Tension), SC (Spreader) \u2014 indicates cable application category<\/p>\n      <p><strong>Base Type:<\/strong> PNCT \u2014 EP rubber insulation + natural\/chloroprene sheath + flexible cable designation<\/p>\n      <p><strong>Modifiers:<\/strong> R (Reinforced), (S) (Shielded), F (Flat Type) \u2014 optional enhancements<\/p>\n      <p><strong>Sheath Material Code:<\/strong> Inherent to PNCT designation (chloroprene)<\/p>\n    <\/div>\n\n    <p>This system allows procurement teams to specify exactly what they need without ambiguity. A cable specified as <code class=\"cd\">FC-PNCT-R<\/code> is unambiguous: Festoon Cable, Reinforced, with all standard PNCT electrical and mechanical properties.<\/p>\n\n  <\/section>\n\n  <!-- ===== S3 ===== -->\n  <section class=\"body\" id=\"s3\">\n    <h2>Cable Type Categories: HT, FC, SC Explained<\/h2>\n\n    <p>The prefix designation indicates the primary application category:<\/p>\n\n    <div class=\"grid-2\">\n      <div>\n        <h4>HT \u2014 High Tension Cable<\/h4>\n        <ul>\n          <li>Primary application: hoist\/lifting power for STS cranes, RTGs, ship unloaders<\/li>\n          <li>Typical run length: 60\u2013120 meters (long span)<\/li>\n          <li>Load conditions: Heavy catenary stress; high tension<\/li>\n          <li>Specification priority: Maximum tensile strength; reinforcement recommended<\/li>\n          <li>Typical specification: <code class=\"cd\">HT-PNCT-R<\/code> or <code class=\"cd\">HT-PNCT-R(S)<\/code><\/li>\n        <\/ul>\n      <\/div>\n      <div>\n        <h4>FC \u2014 Festoon Cable<\/h4>\n        <ul>\n          <li>Primary application: general-purpose trolley\/cart movement; auxiliary circuits<\/li>\n          <li>Typical run length: 30\u201360 meters (medium span)<\/li>\n          <li>Load conditions: Moderate catenary stress; frequent flex cycles<\/li>\n          <li>Specification priority: Balanced tensile strength and flexibility<\/li>\n          <li>Typical specification: <code class=\"cd\">FC-PNCT<\/code> or <code class=\"cd\">FC-PNCT-R<\/code><\/li>\n        <\/ul>\n      <\/div>\n      <div>\n        <h4>SC \u2014 Spreader Cable<\/h4>\n        <ul>\n          <li>Primary application: cable spreader systems; load equalizers<\/li>\n          <li>Typical run length: 5\u201325 meters (short span)<\/li>\n          <li>Load conditions: Lower catenary stress; high flexibility priority<\/li>\n          <li>Specification priority: Maximum flexibility; compact diameter<\/li>\n          <li>Typical specification: <code class=\"cd\">SC-PNCT<\/code> or <code class=\"cd\">SC-PNCT-F<\/code><\/li>\n        <\/ul>\n      <\/div>\n      <div>\n        <h4>PNCT-R (High Voltage)<\/h4>\n        <ul>\n          <li>Primary application: large ship unloaders; power feeds >500 kW<\/li>\n          <li>Typical voltage: 3.6 kV, 6 kV, or 10 kV<\/li>\n          <li>Load conditions: Very high power; long span<\/li>\n          <li>Specification priority: Voltage isolation; reinforcement essential<\/li>\n          <li>Typical specification: <code class=\"cd\">HT-PNCT-R 3.6\/6kV<\/code><\/li>\n        <\/ul>\n      <\/div>\n    <\/div>\n\n    <p><strong>Critical Note:<\/strong> These designations are application recommendations, not hard restrictions. A cable specified as FC (Festoon) can technically be used for HT (High Tension) applications, but it may not be the optimal choice from a cost or performance perspective. Terminal engineers should consult Feichun&#8217;s selection matrix to optimize cable choice for their specific application.<\/p>\n\n  <\/section>\n\n  <!-- ===== S4 ===== -->\n  <section class=\"body\" id=\"s4\">\n    <h2>Specification Modifiers: -R (Reinforced), (S) (Shielded), -F (Flat)<\/h2>\n\n    <p>Optional modifiers can be appended to the base cable type to specify additional features:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>Cable Specification Modifiers<\/caption>\n        <thead><tr><th>Modifier<\/th><th>Full Name<\/th><th>Function<\/th><th>When to Specify<\/th><th>Cost Impact<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><code class=\"cd\">-R<\/code><\/td><td>Reinforced<\/td><td>Integrated Kevlar\u00ae aramid reinforcement layer (0.5\u20131.1 mm); absorbs 80\u201390% of catenary load<\/td><td>Any application with multi-year service life expectation; cable spans >40 meters; high-utilization terminals (18+ hrs\/day)<\/td><td>+15\u201325% vs. standard<\/td><\/tr>\n          <tr><td><code class=\"cd\">(S)<\/code><\/td><td>Shielded<\/td><td>Tinned copper wire braid shield; attenuates EMI from VFD motors<\/td><td>STS cranes with VFD motor drives; ship unloaders with variable-frequency drives; any installation with electronic control sensitivity<\/td><td>+10\u201320% vs. standard<\/td><\/tr>\n          <tr><td><code class=\"cd\">-F<\/code><\/td><td>Flat Type<\/td><td>Flat profile cross-section instead of round; 15\u201320% volume reduction; improved thermal dissipation<\/td><td>High-current hoist motors (>200 A); space-constrained cable routes; compact storage requirements<\/td><td>+5\u201310% vs. round<\/td><\/tr>\n          <tr><td><code class=\"cd\">-R(S)<\/code> or <code class=\"cd\">-RS<\/code><\/td><td>Reinforced + Shielded<\/td><td>Combines reinforcement and shielding in single cable<\/td><td>High-power VFD applications requiring both mechanical durability and EMI protection<\/td><td>+25\u201335% vs. standard<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p><strong>Modifier Combinations:<\/strong> Modifiers can be combined in a single specification. For example, <code class=\"cd\">HT-PNCT-R(S)-F<\/code> specifies a High Tension cable with Reinforcement, Shielding, and Flat Type profile. Such cables exist but represent premium specifications; most installations require only one or two modifiers.<\/p>\n\n  <\/section>\n\n  <!-- ===== S5 ===== -->\n  <section class=\"body\" id=\"s5\">\n    <h2>Conductor Configurations: 2-Core, 3-Core, 4-Core<\/h2>\n\n    <p>Port crane cables are manufactured in multiple core count configurations, allowing a single cable run to serve multiple electrical circuits:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>Conductor Configuration Options<\/caption>\n        <thead><tr><th>Config.<\/th><th>Typical Application<\/th><th>Circuit Usage<\/th><th>Advantages<\/th><th>Disadvantages<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><strong>2-Core<\/strong><\/td><td>Small RTGs, auxiliary power<\/td><td>Single-phase + neutral (240V AC) or positive + negative (DC)<\/td><td>Compact; lowest cost per core<\/td><td>Limited circuit separation; cannot support 3-phase loads<\/td><\/tr>\n          <tr><td><strong>3-Core<\/strong><\/td><td>General festoon; auxiliary circuits; lighting<\/td><td>Three independent circuits OR single phase + neutral + ground<\/td><td>Versatile; balances compactness with flexibility<\/td><td>Not ideal for 3-phase power (requires two cables for 3-phase + neutral)<\/td><\/tr>\n          <tr><td><strong>4-Core<\/strong><\/td><td>Primary hoist power; three-phase + neutral<\/td><td>Three-phase motors (R, S, T phases) + neutral (N) in single run<\/td><td>Complete 3-phase power in one cable; simplifies festoon routing<\/td><td>Larger diameter; higher cost; heavier per 100m<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>The choice of core count should be driven by electrical architecture, not by cost alone. Over-specifying core count (e.g., 4-core when 3-core suffices) adds weight and cost unnecessarily. Under-specifying (e.g., two 2-core cables instead of one 4-core) adds complexity and doubles the termination points, increasing maintenance burden.<\/p>\n\n  <\/section>\n\n  <!-- ===== S6 ===== -->\n  <section class=\"body\" id=\"s6\">\n    <h2>Cable Specification Parameters<\/h2>\n\n    <p>When specifying a cable, the following parameters must be clearly defined:<\/p>\n\n    <div class=\"order-box\">\n      <h4>Essential Specification Parameters<\/h4>\n      <p><strong>1. Cable Type &#038; Modifiers:<\/strong> <code class=\"cd\">HT-PNCT-R<\/code>, <code class=\"cd\">FC-PNCT<\/code>, etc.<\/p>\n      <p><strong>2. Voltage Rating:<\/strong> 0.6\/1 kV (standard), 3.6\/6 kV, 6\/10 kV, etc.<\/p>\n      <p><strong>3. Conductor Configuration:<\/strong> 2 \u00d7 [size], 3 \u00d7 [size], or 4 \u00d7 [size]. Example: <code class=\"cd\">3 \u00d7 2.5 sq mm<\/code><\/p>\n      <p><strong>4. Overall Diameter (if specified):<\/strong> Maximum acceptable cable OD. If not specified, manufacturer&#8217;s standard is assumed.<\/p>\n      <p><strong>5. Total Length:<\/strong> Example: &#8220;500 meters on single spool&#8221; or &#8220;100 meters on reel + 50 meters on reel&#8221;<\/p>\n      <p><strong>6. Operating Conditions:<\/strong> Location (port, steelworks, power station, etc.), equipment type (STS crane, RTG, unloader), maximum tension, movement distance\/speed, and any special environmental requirements (high salt spray, extreme UV, arctic conditions, etc.)<\/p>\n      <p><strong>7. Reel Specifications:<\/strong> Reel dimensions, torque rating, if applicable. Standard is 1,000 mm diameter \u00d7 800 mm width for port crane cables.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S7 ===== -->\n  <section class=\"body\" id=\"s7\">\n    <h2>How to Specify a Cable: Complete Checklist<\/h2>\n\n    <p>Use this step-by-step checklist to prepare accurate cable specifications for quotation or purchase order:<\/p>\n\n    <div class=\"order-box\">\n      <h4>Step 1: Identify Application Category<\/h4>\n      <div class=\"example\">\u25a1 HT (High Tension) \u2014 hoist\/main power\n\u25a1 FC (Festoon) \u2014 trolley\/general motion\n\u25a1 SC (Spreader) \u2014 load equalizer\n\u25a1 Other (specify): ________________<\/div>\n    <\/div>\n\n    <div class=\"order-box\">\n      <h4>Step 2: Determine Required Modifiers<\/h4>\n      <div class=\"example\">\u25a1 -R (Reinforced) \u2014 service life >5 years? YES \/ NO\n\u25a1 (S) (Shielded) \u2014 VFD motor drive present? YES \/ NO\n\u25a1 -F (Flat Type) \u2014 space constraints or high current? YES \/ NO<\/div>\n    <\/div>\n\n    <div class=\"order-box\">\n      <h4>Step 3: Select Voltage &#038; Standard<\/h4>\n      <div class=\"example\">\u25a1 0.6\/1 kV (standard port crane)\n\u25a1 3.6\/6 kV (ship unloader)\n\u25a1 6\/10 kV (large power application)<\/div>\n    <\/div>\n\n    <div class=\"order-box\">\n      <h4>Step 4: Specify Conductor Configuration<\/h4>\n      <div class=\"example\">\u25a1 2 \u00d7 _____ sq mm (specify size: 1.0, 1.5, 2.5, 4, 6, 10, etc.)\n\u25a1 3 \u00d7 _____ sq mm\n\u25a1 4 \u00d7 _____ sq mm<\/div>\n    <\/div>\n\n    <div class=\"order-box\">\n      <h4>Step 5: Document Operational Requirements<\/h4>\n      <div class=\"example\">Application: STS Crane \/ RTG \/ Ship Unloader \/ Other\nSpan length: _____ meters\nAnnual utilization: _____ hours\/day, _____ days\/week\nOperating location: _________________________________\nEnvironmental hazards: Saltwater spray \/ UV \/ Oil \/ High temperature \/ Other<\/div>\n    <\/div>\n\n    <div class=\"order-box\">\n      <h4>Step 6: Compile Full Specification<\/h4>\n      <div class=\"example\">Example Purchase Order Specification:\n\n&#8220;Supply 500 meters of HT-PNCT-R cable, 4 \u00d7 2.5 sq mm, \n0.6\/1 kV, on single 1,000 mm \u00d7 800 mm spool. \nApplication: STS crane hoist power. \nSpan: 65 meters. Utilization: 20 hrs\/day, 7 days\/week. \nLocation: Busan container terminal (high saltwater exposure). \nCertification: KSC IEC 60502-1 compliant with Certificate of Conformance. \nDelivery: FOB Shanghai, 4-week lead time.&#8221;<\/div>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S8 ===== -->\n  <section class=\"body\" id=\"s8\">\n    <h2>Technical Data: PNCT-F Complete Specifications<\/h2>\n\n    <p>The following table provides complete technical specifications for PNCT-F flat-type cables across all standard conductor sizes and configurations:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>PNCT-F Flat Type Cable \u2014 3-Core &#038; 4-Core Configurations (Sample Data)<\/caption>\n        <thead><tr><th>Config.<\/th><th>Conductor Size sq mm<\/th><th>Insulation (mm)<\/th><th>Sheath (mm)<\/th><th>Overall Diameter (mm)<\/th><th>Weight kg\/km<\/th><th>Resistance \u03a9\/km<\/th><th>Test Voltage V\/1min<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td colspan=\"8\" style=\"text-align:center;font-weight:700;background:var(--bg-th);color:var(--c-inverse)\">3-CORE CONFIGURATIONS<\/td><\/tr>\n          <tr><td>3 \u00d7 1.0<\/td><td>1.0<\/td><td>1.3<\/td><td>2.6<\/td><td>9.4 \u00d7 13.1<\/td><td>174<\/td><td>20.0<\/td><td>3,500<\/td><\/tr>\n          <tr><td>3 \u00d7 1.5<\/td><td>1.5<\/td><td>1.6<\/td><td>2.6<\/td><td>9.7 \u00d7 13.7<\/td><td>193<\/td><td>13.7<\/td><td>3,500<\/td><\/tr>\n          <tr><td>3 \u00d7 2.5<\/td><td>2.5<\/td><td>2.1<\/td><td>2.7<\/td><td>10.4 \u00d7 14.9<\/td><td>238<\/td><td>8.21<\/td><td>3,500<\/td><\/tr>\n          <tr><td>3 \u00d7 4<\/td><td>4.0<\/td><td>2.6<\/td><td>2.7<\/td><td>10.9 \u00d7 15.9<\/td><td>284<\/td><td>5.09<\/td><td>3,500<\/td><\/tr>\n          <tr><td>3 \u00d7 6<\/td><td>6.0<\/td><td>3.6<\/td><td>2.8<\/td><td>12.2 \u00d7 18.3<\/td><td>349<\/td><td>3.39<\/td><td>3,500<\/td><\/tr>\n          <tr><td>3 \u00d7 10<\/td><td>10<\/td><td>4.8<\/td><td>2.9<\/td><td>13.6 \u00d7 20.9<\/td><td>495<\/td><td>1.95<\/td><td>3,500<\/td><\/tr>\n          <tr><td colspan=\"8\" style=\"text-align:center;font-weight:700;background:var(--bg-th);color:var(--c-inverse)\">4-CORE CONFIGURATIONS<\/td><\/tr>\n          <tr><td>4 \u00d7 1.0<\/td><td>1.0<\/td><td>1.3<\/td><td>2.7<\/td><td>9.6 \u00d7 17.0<\/td><td>241<\/td><td>20.0<\/td><td>3,500<\/td><\/tr>\n          <tr><td>4 \u00d7 1.5<\/td><td>1.5<\/td><td>1.6<\/td><td>2.7<\/td><td>9.9 \u00d7 17.9<\/td><td>270<\/td><td>13.7<\/td><td>3,500<\/td><\/tr>\n          <tr><td>4 \u00d7 2.5<\/td><td>2.5<\/td><td>2.1<\/td><td>2.8<\/td><td>10.6 \u00d7 19.6<\/td><td>335<\/td><td>8.21<\/td><td>3,500<\/td><\/tr>\n          <tr><td>4 \u00d7 4<\/td><td>4.0<\/td><td>2.6<\/td><td>2.9<\/td><td>11.3 \u00d7 21.3<\/td><td>413<\/td><td>5.09<\/td><td>3,500<\/td><\/tr>\n          <tr><td>4 \u00d7 6<\/td><td>6.0<\/td><td>3.6<\/td><td>3.0<\/td><td>13.2 \u00d7 34.5<\/td><td>500<\/td><td>3.39<\/td><td>3,500<\/td><\/tr>\n          <tr><td>4 \u00d7 10<\/td><td>10<\/td><td>4.8<\/td><td>3.2<\/td><td>14.2 \u00d7 28.8<\/td><td>741<\/td><td>1.95<\/td><td>3,500<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>All PNCT-F cables meet KSC IEC 60502-1 electrical and mechanical requirements. The flat profile (shown as width \u00d7 height in the Overall Diameter column) reduces storage volume while maintaining rated current capacity and bending flexibility.<\/p>\n\n  <\/section>\n\n  <!-- ===== S9 ===== -->\n  <section class=\"body\" id=\"s9\">\n    <h2>Common Specification Errors &#038; Solutions<\/h2>\n\n    <div class=\"tw\">\n      <table>\n        <caption>Common Specification Mistakes &#038; Corrections<\/caption>\n        <thead><tr><th>Error<\/th><th>Problem<\/th><th>Correct Approach<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><strong>Specifying only &#8220;PNCT&#8221; without modifiers<\/strong><\/td><td>Ambiguous; supplier may deliver standard (non-reinforced) cable when reinforcement was needed<\/td><td>Always include -R modifier if multi-year service life expected. Specify: <code class=\"cd\">HT-PNCT-R<\/code>, not just <code class=\"cd\">HT-PNCT<\/code><\/td><\/tr>\n          <tr><td><strong>Forgetting to specify shielding for VFD applications<\/strong><\/td><td>Unshielded cables allow EMI from VFD motor to couple onto power lines, causing nuisance trips and equipment damage<\/td><td>For any VFD crane: specify <code class=\"cd\">HT-PNCT-R(S)<\/code> explicitly. Do not assume shielding is standard.<\/td><\/tr>\n          <tr><td><strong>Confusing voltage rating with safety factor<\/strong><\/td><td>Specifying 0.6\/1 kV cable for &#8220;low voltage&#8221; 400V application without considering safety margin<\/td><td>0.6\/1 kV cables have 3.5\u00d7 safety margin over 400V primary. This is correct and standard. Upgrade to 3.6\/6 kV only for ship unloader applications exceeding 500 kW.<\/td><\/tr>\n          <tr><td><strong>Over-specifying core count<\/strong><\/td><td>Specifying 4-core cable when 3-core would suffice; wastes money and adds unnecessary weight<\/td><td>Choose core count based on electrical circuit requirements, not cost. If only 3 circuits needed, specify 3-core.<\/td><\/tr>\n          <tr><td><strong>Not specifying overall diameter limit<\/strong><\/td><td>Supplier delivers cable within standard but larger diameter than equipment can accommodate (e.g., sheave size constraints)<\/td><td>If diameter is constrained by existing equipment, specify: &#8220;Maximum OD: 25 mm&#8221; to prevent over-sizing.<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S10 ===== -->\n  <section class=\"body\" id=\"s10\">\n    <h2>Selection Guide: Which Cable Type for Your Application<\/h2>\n\n    <p><strong>STS Crane (Ship-to-Shore) \u2014 Hoist Power:<\/strong> Specify <code class=\"cd\">HT-PNCT-R<\/code> or <code class=\"cd\">HT-PNCT-R(S)<\/code> (if VFD). Conductor size: 4\u201310 sq mm depending on hoist motor power. Configuration: typically 4-core for three-phase hoist + neutral.<\/p>\n\n    <p><strong>STS Crane \u2014 Trolley\/Carriage Motion:<\/strong> Specify <code class=\"cd\">FC-PNCT<\/code> or <code class=\"cd\">FC-PNCT-R<\/code> (if multi-year contract). Conductor size: 1.5\u20132.5 sq mm. Configuration: typically 3-core.<\/p>\n\n    <p><strong>RTG (Rubber-Tyred Gantry):<\/strong> Specify <code class=\"cd\">FC-PNCT-R<\/code>. Conductor size: 1.5\u20134 sq mm depending on motor size. Configuration: 4-core recommended for hoist + trolley motion in single cable.<\/p>\n\n    <p><strong>Ship Unloader (Bulk or Container):<\/strong> Specify <code class=\"cd\">HT-PNCT-R(S) 3.6\/6kV<\/code> for large units (>500 kW). Conductor size: 6\u201316 sq mm. Configuration: 4-core. If power exceeds 1 MW, consult Feichun for high-voltage options.<\/p>\n\n    <p><strong>Mobile Harbour Crane:<\/strong> Specify <code class=\"cd\">HT-PNCT-R<\/code> for hoist cable. Conductor size: 2.5\u20136 sq mm. If VFD motor: add (S) modifier. Boom cable may be lower specification: <code class=\"cd\">FC-PNCT<\/code>.<\/p>\n\n    <p><strong>Cableveyor System:<\/strong> Specify <code class=\"cd\">FC-PNCT-R<\/code> or <code class=\"cd\">SC-PNCT-R-F<\/code> (flat preferred for compact runs). Conductor size: 1.5\u20134 sq mm depending on drive motor. Configuration: typically 2 or 3-core depending on circuit requirements.<\/p>\n\n  <\/section>\n\n  <!-- ===== S11 ===== -->\n  <section class=\"body\" id=\"s11\">\n    <h2>Quality Assurance &#038; Certification<\/h2>\n\n    <p>All Feichun cables, regardless of type or configuration, are manufactured to the same rigorous quality standards:<\/p>\n\n    <p>\u2713 <strong>KSC IEC 60502-1 Compliance:<\/strong> All cables meet or exceed Korean and international standards for 0.6\/1 kV flexible cables<\/p>\n\n    <p>\u2713 <strong>Certificate of Conformance:<\/strong> Every cable batch includes documented test results (dielectric strength, insulation resistance, tensile properties, flex-cycle endurance)<\/p>\n\n    <p>\u2713 <strong>Third-Party Testing:<\/strong> All testing performed at ISO\/IEC 17025-accredited independent laboratories<\/p>\n\n    <p>\u2713 <strong>Material Traceability:<\/strong> Complete supply chain documentation from copper sourcing through final cable assembly<\/p>\n\n    <p>\u2713 <strong>10-Year Warranty Archive:<\/strong> All Certificate of Conformance documents retained for 10 years for warranty and compliance verification<\/p>\n\n  <\/section>\n\n  <!-- ===== S12 ===== -->\n  <section class=\"refs\" id=\"s12\">\n    <h2>References &#038; Standards<\/h2>\n    <ol class=\"rl\">\n      <li>KSC 3317 \u2014 <em>Rubber Insulated Flexible Cables 0.6\/1kV<\/em> (Korean Industrial Standard)<\/li>\n      <li>IEC 60502-1 \u2014 <em>General requirements for cables, cords and flexible cords \u2014 Part 1: Rated voltages up to and including 450\/750V<\/em><\/li>\n      <li>IEC 60228 \u2014 <em>Conductors of insulated cables \u2014 Classification and construction requirements<\/em><\/li>\n      <li>IEC 60811-1-1 \u2014 <em>Insulating and sheathing materials of electric and optical cables \u2014 Common test methods<\/em><\/li>\n      <li>Feichun Cable \u2014 Internal Specification Guide and Purchase Order Template<\/li>\n    <\/ol>\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Anhui Feichun Special Cable Co., Ltd. \u2014 Cable Specification &#038; Selection Assistance<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\"><span class=\"lb\">Cable Selection &#038; Technical Consulting<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Purchase Order &#038; Quotation Support<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">24\/7 Emergency Support<\/span>+86 138 5608 5607<\/div>\n      <div class=\"ci\"><span class=\"lb\">Technical WhatsApp &#038; WeChat<\/span>+86 138 5512 3218<\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>This comprehensive technical reference covers PNCT-F flat type port crane cables, the complete cable type designation system (HT, FC, SC), specification modifiers (-R, -S, -F), conductor configurations, cable specification procedures, and technical data for all standard cable variants. Intended for terminal operators, crane engineers, and procurement professionals specifying cables for port cranes, ship unloaders, RTGs, and maritime festoon systems. All specifications conform to KSC 3317 and IEC 60502-1 standards.<\/p>\n    <p style=\"margin-top:.5rem;\">\u00a9 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.<\/p>\n  <\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n","protected":false},"excerpt":{"rendered":"PNCT-F designation identifies cables with a flat profile cross-section, as opposed to the standard round profile. While round cables are universal and flexible, flat cables offer specific advantages for certain port crane applications:\nCompact Storage and Handling: Flat cables pack more efficiently on drums and spools. A flat cable occupies approximately 15\u201320% less volume than a round cable of equivalent conductor area, reducing storage footprint and shipping volume.\nImproved Thermal Dissipation: The flat geometry increases surface area relative to volume, enabling better heat dissipation from the conductor. In high-current applications (large hoist motors), flat cables run cooler than round cables, reducing insulation aging and extending service life.\nEasier Cable Management: Flat cables lay flatter in cable troughs and festoon routes, reducing twisting and tangling. This property is particularly valuable in complex multi-cable installations where space is constrained.\nLower Profile Aesthetics: For applications where cable profile affects equipment appearance or port terminal aesthetics, flat cables provide a lower-profile alternative.","protected":false},"author":1,"featured_media":10358,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,8,35,56],"tags":[52141,25791,52140,52139,52132,31942,38115,52125,3305,52134,52127,52123,3269,52118,38012,52137,6336,52122,4491,36,52135,17038,52129,52133,23453,52124,52079,52114,52085,385,52145,46052,52138,37624,52149,52128,2531,52130,52142,52146,52143,52078,52126,2607,52121,1063,2782,52147,52131,2586,2604,52144,52136,52148,1088,37485],"class_list":["post-10357","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-cranes-and-material-handling-cable","category-festoon-cable","category-reeling-cable","tag-2-core-cable-2","tag-3-core-cable-2","tag-4-core-cable","tag-application-category","tag-base-type","tag-cable-designation","tag-cable-management","tag-cable-ordering","tag-cable-selection-guide","tag-cable-specification-checklist","tag-cable-specification-system","tag-cable-type-selection","tag-cableveyor-system","tag-certificate-of-conformance","tag-conductor-configuration","tag-designation-format","tag-emi-shielding","tag-fc-cable","tag-feichun-cable","tag-festoon-cable","tag-festoon-cable-type","tag-flat-profile-cable","tag-flat-type-cable","tag-flat-type-modifier","tag-high-tension-cable","tag-ht-cable","tag-kevlar-reinforcement","tag-korean-standard","tag-ksc-iec-60502-1","tag-marine-cable","tag-material-traceability","tag-mobile-harbour-crane-cable","tag-operating-conditions","tag-overall-diameter","tag-pnct-series","tag-pnct-f-cable","tag-port-crane-cable","tag-prefix-designation","tag-purchase-order-specification","tag-quality-assurance","tag-reel-specifications","tag-reinforced-cable","tag-round-vs-flat-cable","tag-rtg-crane-cable","tag-sc-cable","tag-shielded-cable","tag-ship-unloader-cable","tag-specification-errors","tag-specification-modifiers","tag-spreader-cable","tag-sts-crane-cable","tag-technical-data","tag-thermal-dissipation","tag-third-party-testing","tag-vfd-cable","tag-voltage-rating","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10357","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=10357"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10357\/revisions"}],"predecessor-version":[{"id":10359,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10357\/revisions\/10359"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/10358"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=10357"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=10357"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=10357"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}