{"id":10333,"date":"2026-04-13T14:19:01","date_gmt":"2026-04-13T06:19:01","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?p=10333"},"modified":"2026-04-13T14:19:04","modified_gmt":"2026-04-13T06:19:04","slug":"jis-c-3327-cable-code-designation","status":"publish","type":"post","link":"https:\/\/feichuncables.com\/blog\/jis-c-3327-cable-code-designation\/","title":{"rendered":"JIS C 3327 Cable Code Designation"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The Complete Technical Reference for Decoding Japanese Industrial Standard Flexible Cable Names \u2014 Understanding Class Numbers, Material Symbols, Insulation Codes, Sheath Codes, and the CT Designation System Across All 15 Cable Types Defined by JIS C 3327<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An Essential Reference for Engineers, Specifiers, and Procurement Professionals Working with Japanese-Standard Port Crane Cables, Ship Unloader Cables, Industrial Cabtyre Cables, and Flexible Power Cables: How to Read, Decode, and Correctly Specify Any JIS C 3327 Cable from the Simplest 1CT Natural Rubber Cable to the Most Advanced 4PNCT EP Rubber \/ Chloroprene Sheathed High-Performance Crane Cable<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img data-dominant-color=\"e5e5e5\" data-has-transparency=\"false\" style=\"--dominant-color: #e5e5e5;\" loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"628\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" src=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1165-800x628.avif\" alt=\"\" class=\"wp-image-10334 not-transparent\" title=\"\" srcset=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1165-800x628.avif 800w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1165-300x235.avif 300w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1165-768x603.avif 768w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1165-400x314.avif 400w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1165-832x653.avif 832w, https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/image-1165.avif 1008w\" \/><\/figure>\n\n\n\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>JIS C 3327 Cable Code Designation \u2014 Complete Guide to Japanese Industrial Standard Flexible Cable Naming, Classification System, Symbol Meanings &#038; Decoding | FeiChun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical reference for JIS C 3327 cable code designation system. Decode Japanese standard flexible cable names: class numbers, insulation codes, sheath codes, and CT designation. Covers all 15 cable types from 1CT to KKCT. Understand 2PNCT, 3PNCT, 2RNCT, and all variants. Essential reference for port crane, ship unloader, and industrial cable specifiers.\">\n<meta name=\"keywords\" content=\"JIS C 3327, cable code designation, Japanese cable standard, cable naming convention, PNCT meaning, 2PNCT code, 3PNCT code, CT flexible cable, cabtyre cable, cable classification, EP rubber cable code, chloroprene rubber cable code, natural rubber cable, silicone rubber cable, cable class 1 2 3 4, Japanese industrial standard cable, port crane cable specification, cable designation guide, cable symbol meaning, RNCT cable, PHCT cable, KKCT cable, cable insulation code, cable sheath code, FeiChun cable reference\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd.\">\n<meta name=\"robots\" content=\"index,follow\">\n<meta property=\"og:title\" content=\"JIS C 3327 Cable Code Designation \u2014 Complete Decoding Guide for Japanese Standard Flexible Cables\">\n<meta property=\"og:type\" content=\"article\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#0066CC;--c-link-hover:#004499;--c-accent:#0066CC;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#0066CC;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;--hl-red-glow:rgba(255,60,60,0.08)}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#6BA3FF;--c-link-hover:#8CB5FF;--c-accent:#6BA3FF;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#6BA3FF;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#6BA3FF;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;--hl-red-glow:rgba(255,60,60,0.15)}}*,*::before,*::after{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8;overflow-x:hidden}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:.6rem;margin-right:.4rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.5rem,3.7vw,2.15rem);line-height:1.22;margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-en{font-size:.82rem;color:var(--c-tertiary);line-height:1.5;font-style:italic;margin-top:.5rem;padding-top:.5rem;border-top:1px solid var(--b-light)}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary);text-align:justify}.body strong{font-weight:600;color:var(--c-body)}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.83rem;line-height:1.45}.tw caption{text-align:left;font-weight:600;font-size:.76rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.72rem;padding:.55rem .7rem;text-align:left;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.45rem .7rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note.red{background:var(--hl-red-glow);border-left-color:#C0392B}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem}.refs{margin-top:2.8rem;padding-top:1.5rem;border-top:2px solid var(--b-rule)}.refs h2{font-size:1.08rem;margin-bottom:.9rem}.rl{list-style:none;counter-reset:rf;padding:0}.rl li{counter-increment:rf;font-size:.79rem;color:var(--c-tertiary);margin-bottom:.55rem;padding-left:2.2rem;position:relative;line-height:1.5}.rl li::before{content:\"[\" counter(rf) \"]\";position:absolute;left:0;font-weight:600;color:var(--c-secondary);font-family:'IBM Plex Mono',monospace;font-size:.74rem}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.82rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.68rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ci a:hover{text-decoration:underline}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.74rem;color:var(--c-tertiary);text-align:center;line-height:1.55}.tm{font-size:.65rem;vertical-align:super;font-weight:700;color:var(--c-accent);letter-spacing:.02em}code.cd{font-family:'IBM Plex Mono',monospace;font-size:.92em;background:var(--bg-code);padding:.15em .4em;border-radius:3px;font-weight:500;color:var(--c-body);letter-spacing:.02em}.decode{display:flex;flex-wrap:wrap;align-items:center;gap:.5rem;margin:1.2rem 0;padding:1rem 1.2rem;background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px}.decode .seg{text-align:center;padding:.4rem .6rem;border-radius:3px;line-height:1.3}.decode .seg .val{font-family:'IBM Plex Mono',monospace;font-size:1.3rem;font-weight:700;display:block;color:var(--c-body)}.decode .seg .lbl{font-size:.62rem;font-weight:600;letter-spacing:.08em;text-transform:uppercase;display:block;margin-top:.15rem}.decode .seg.cls{background:#E3F2FD;color:#1565C0}.decode .seg.cls .lbl{color:#1565C0}.decode .seg.ins{background:#E8F5E9;color:#2E7D32}.decode .seg.ins .lbl{color:#2E7D32}.decode .seg.sht{background:#FFF3E0;color:#E65100}.decode .seg.sht .lbl{color:#E65100}.decode .seg.base{background:#F3E5F5;color:#6A1B9A}.decode .seg.base .lbl{color:#6A1B9A}.decode .plus{font-size:1.1rem;font-weight:700;color:var(--c-tertiary)}.decode .eq{font-size:1.1rem;font-weight:700;color:var(--c-accent)}@media(prefers-color-scheme:dark){.decode .seg.cls{background:#1A2B3D;color:#90CAF9}.decode .seg.cls .lbl{color:#90CAF9}.decode .seg.ins{background:#1B2E1B;color:#A5D6A7}.decode .seg.ins .lbl{color:#A5D6A7}.decode .seg.sht{background:#2E2010;color:#FFB74D}.decode .seg.sht .lbl{color:#FFB74D}.decode .seg.base{background:#2A1A30;color:#CE93D8}.decode .seg.base .lbl{color:#CE93D8}}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.3rem}.tw{font-size:.76rem}.cg{grid-template-columns:1fr}.decode{gap:.3rem}.decode .seg .val{font-size:1.05rem}.decode .seg{padding:.3rem .4rem}}<\/style>\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechArticle\",\"headline\":\"JIS C 3327 Cable Code Designation \u2014 Complete Guide to Japanese Industrial Standard Flexible Cable Naming & Classification System\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"datePublished\":\"2026-04-13\"}<\/script>\n<\/head>\n<body>\n<div class=\"page-wrap\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">JIS C 3327 \u2014 Reference Guide<\/span>\n    <span class=\"badge\">Cable Code Designation<\/span>\n    <span class=\"badge\">15 Cable Classifications<\/span>\n    <span class=\"badge\">Complete Decoding System<\/span>\n    <h1>JIS C 3327 Cable Code Designation<\/h1>\n    <p class=\"sub\">The Complete Technical Reference for Decoding Japanese Industrial Standard Flexible Cable Names \u2014 Understanding Class Numbers, Material Symbols, Insulation Codes, Sheath Codes, and the CT Designation System Across All 15 Cable Types Defined by JIS C 3327<\/p>\n    <p class=\"sub-en\">An Essential Reference for Engineers, Specifiers, and Procurement Professionals Working with Japanese-Standard Port Crane Cables, Ship Unloader Cables, Industrial Cabtyre Cables, and Flexible Power Cables: How to Read, Decode, and Correctly Specify Any JIS C 3327 Cable from the Simplest 1CT Natural Rubber Cable to the Most Advanced 4PNCT EP Rubber \/ Chloroprene Sheathed High-Performance Crane Cable<\/p>\n    <div class=\"meta\">\n      <span>Anhui Feichun Special Cable Co., Ltd.<\/span>\n      <span>Published April 2026<\/span>\n      <span>10 min technical reference<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">Introduction: Why Cable Code Designation Matters<\/a><\/li>\n      <li><a href=\"#s2\">The Four-Part Code Structure<\/a><\/li>\n      <li><a href=\"#s3\">Symbol Dictionary: Every Letter Decoded<\/a><\/li>\n      <li><a href=\"#s4\">Flexibility Classes: 1 Through 4<\/a><\/li>\n      <li><a href=\"#s5\">Insulation Materials: The First Variable<\/a><\/li>\n      <li><a href=\"#s6\">Sheath Materials: The Second Variable<\/a><\/li>\n      <li><a href=\"#s7\">Complete Classification Table: All 15 Cable Types<\/a><\/li>\n      <li><a href=\"#s8\">Decoding Examples: Reading Any JIS C 3327 Cable Name<\/a><\/li>\n      <li><a href=\"#s9\">Extended Suffixes: SB, Light, RB &amp; Voltage Prefixes<\/a><\/li>\n      <li><a href=\"#s10\">Feichun Product Cross-Reference<\/a><\/li>\n      <li><a href=\"#s11\">Quick-Reference Decoding Chart<\/a><\/li>\n      <li><a href=\"#s12\">References &amp; Standards<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <!-- ===== S1 ===== -->\n  <section class=\"body\" id=\"s1\">\n    <h2>Introduction: Why Cable Code Designation Matters<\/h2>\n\n    <p>Every cable manufactured to the Japanese Industrial Standard <strong>JIS C 3327<\/strong> carries a code designation that functions as a compressed technical specification. When a crane manufacturer specifies a <code class=\"cd\">2PNCT<\/code> cable, or a port terminal engineer orders a <code class=\"cd\">3PNCT<\/code> replacement, the code itself communicates the cable&#8217;s flexibility class, insulation material, sheath material, and cable category\u2014without requiring the engineer to look up a product catalogue. For anyone working with Japanese-standard cables\u2014whether in port crane installations, ship unloader systems, industrial material handling, or general-purpose flexible power distribution\u2014understanding this code system is a fundamental professional skill.<\/p>\n\n    <p>The JIS C 3327 designation system is elegant in its logic. Every cable name follows a <strong>predictable, parseable structure<\/strong> where each character or character group carries a specific, unambiguous meaning. Once you understand the five material symbols and the four flexibility classes, you can decode any of the <strong>15 cable types<\/strong> defined by the standard\u2014and immediately know what the cable is made of, how flexible it is, and what applications it is suited for.<\/p>\n\n    <p>This reference guide provides the complete decoding system for JIS C 3327 cable codes, with worked examples, a visual symbol dictionary, and a cross-reference to Feichun&#8217;s product range. Bookmark this page\u2014it will save you time on every Japanese-standard cable specification you encounter.<\/p>\n  <\/section>\n\n  <!-- ===== S2 ===== -->\n  <section class=\"body\" id=\"s2\">\n    <h2>The Four-Part Code Structure<\/h2>\n\n    <p>Every JIS C 3327 cable code follows the same structural formula. The code is assembled from up to four parts, read left to right:<\/p>\n\n    <div class=\"decode\">\n      <div class=\"seg cls\"><span class=\"val\">Class<\/span><span class=\"lbl\">Flexibility<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg ins\"><span class=\"val\">Insulation<\/span><span class=\"lbl\">Material Code<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg sht\"><span class=\"val\">Sheath<\/span><span class=\"lbl\">Material Code<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg base\"><span class=\"val\">CT<\/span><span class=\"lbl\">Flexible Cable<\/span><\/div>\n    <\/div>\n\n    <p><strong>Part 1 \u2014 Class Number (1, 2, 3, or 4):<\/strong> A single digit at the beginning of the code that defines the cable&#8217;s flexibility classification. Class 1 is the least flexible; Class 4 is the most flexible. The class number is omitted only for the special case of silicone rubber cables (KKCT), which have a single class designation.<\/p>\n\n    <p><strong>Part 2 \u2014 Insulation Material Code (optional letter):<\/strong> A single letter identifying the insulation material. If this letter is absent, the insulation is natural rubber (the default material in the original JIS standard). If present, it identifies a non-default insulation material: <strong>P<\/strong> for EP rubber, <strong>K<\/strong> for silicone rubber, etc.<\/p>\n\n    <p><strong>Part 3 \u2014 Sheath Material Code (optional letter):<\/strong> A single letter identifying the outer sheath material. If absent, the sheath is natural rubber (default). If present, it identifies a non-default sheath material: <strong>R<\/strong> for chloroprene rubber (polychloroprene), <strong>H<\/strong> for polyethylene chlorosulfonide rubber, <strong>K<\/strong> for silicone rubber, etc.<\/p>\n\n    <p><strong>Part 4 \u2014 CT (always present):<\/strong> The suffix <strong>CT<\/strong> appears at the end of every code. It stands for <em>Cabtyre<\/em>\u2014the Japanese industrial term for a flexible cable designed for portable or dynamic applications. The CT suffix is the universal identifier that marks a cable as a JIS C 3327 flexible cable rather than a fixed-installation cable covered by other standards.<\/p>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">The &#8220;Implicit Default&#8221; Rule<\/div>\n      <p>The JIS C 3327 code system uses <strong>natural rubber as the implicit default<\/strong> for both insulation and sheath. When a material code letter is <em>absent<\/em>, natural rubber is implied. This is why the simplest cable designation is just <code class=\"cd\">CT<\/code> (with a class number prefix)\u2014it means natural rubber insulation + natural rubber sheath + flexible cable. Material code letters only appear when the cable uses a <em>non-default<\/em> material. Understanding this &#8220;absence means natural rubber&#8221; rule is the key to decoding any JIS C 3327 cable name.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S3 ===== -->\n  <section class=\"body\" id=\"s3\">\n    <h2>Symbol Dictionary: Every Letter Decoded<\/h2>\n\n    <p>JIS C 3327 uses exactly <strong>six symbols<\/strong> to encode all cable information. Five are material codes and one is the cable category identifier:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>JIS C 3327 \u2014 Complete Symbol Dictionary<\/caption>\n        <thead><tr><th>Symbol<\/th><th>Meaning<\/th><th>Material \/ Function<\/th><th>Chemical Basis<\/th><th>Key Properties<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><code class=\"cd\">CT<\/code><\/td><td>Flexible cable<\/td><td>Cabtyre cable (category identifier)<\/td><td>\u2014<\/td><td>Identifies the cable as a JIS C 3327 flexible cable for portable\/dynamic use<\/td><\/tr>\n          <tr><td><code class=\"cd\">N<\/code><\/td><td>Natural rubber<\/td><td>Insulation or sheath material<\/td><td>Polyisoprene (cis-1,4-polyisoprene)<\/td><td>Good flexibility, moderate oil resistance, limited UV\/ozone resistance<\/td><\/tr>\n          <tr><td><code class=\"cd\">R<\/code><\/td><td>Chloroprene rubber<\/td><td>Sheath material (polychloroprene)<\/td><td>Polychloroprene (Neoprene\u00ae type)<\/td><td>Excellent oil, flame, UV, ozone, and saltwater resistance \u2014 the port crane standard<\/td><\/tr>\n          <tr><td><code class=\"cd\">P<\/code><\/td><td>EP rubber<\/td><td>Insulation material (ethylene propylene)<\/td><td>Ethylene propylene diene monomer (EPDM)<\/td><td>Superior dielectric strength, flexibility retention at \u221230\u00b0C, ozone resistance<\/td><\/tr>\n          <tr><td><code class=\"cd\">H<\/code><\/td><td>Polyethylene chlorosulfonide rubber<\/td><td>Sheath material (Hypalon\u00ae type)<\/td><td>Chlorosulfonated polyethylene (CSM)<\/td><td>Exceptional chemical resistance, UV stability, nuclear\/chemical industry use<\/td><\/tr>\n          <tr><td><code class=\"cd\">K<\/code><\/td><td>Silicone rubber<\/td><td>Insulation and\/or sheath material<\/td><td>Polydimethylsiloxane (PDMS)<\/td><td>Extreme temperature range (\u221260\u00b0C to +180\u00b0C), very flexible, low smoke<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"note green\">\n      <div class=\"nt\">Natural Rubber \u2014 The &#8220;Silent&#8221; Symbol<\/div>\n      <p>Natural rubber (<code class=\"cd\">N<\/code>) is unique in the JIS system: it is the only material that can be <strong>either explicitly stated or silently implied<\/strong>. In codes like <code class=\"cd\">RNCT<\/code>, the <code class=\"cd\">N<\/code> appears explicitly to indicate natural rubber insulation (because the sheath letter <code class=\"cd\">R<\/code> is already present and the code needs to show both materials). In codes like <code class=\"cd\">CT<\/code>, natural rubber is implied for <em>both<\/em> insulation and sheath\u2014no letters are needed because both materials are the default. This dual behaviour of the <code class=\"cd\">N<\/code> symbol is the most common source of confusion when first learning the JIS coding system.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S4 ===== -->\n  <section class=\"body\" id=\"s4\">\n    <h2>Flexibility Classes: 1 Through 4<\/h2>\n\n    <p>The class number prefix defines the cable&#8217;s <strong>conductor flexibility<\/strong> per IEC 60228 and JIS C 3327. Higher class numbers indicate finer conductor stranding and greater flexibility:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>JIS C 3327 Flexibility Classes<\/caption>\n        <thead><tr><th>Class<\/th><th>Flexibility Level<\/th><th>Conductor Construction<\/th><th>Typical Applications<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><strong>Class 1<\/strong><\/td><td>Rigid \/ Solid<\/td><td>Solid conductor or coarse stranding. Minimum strand count per IEC 60228 Class 1.<\/td><td>Fixed installations only. Not suitable for any dynamic or portable application.<\/td><\/tr>\n          <tr><td><strong>Class 2<\/strong><\/td><td>Moderate flexibility<\/td><td>Stranded conductor with moderate strand count. Balanced flexibility and compressive resistance.<\/td><td>TRACAB\u00ae systems: curtain, carrier drum, cableveyor. Multi-method transport compatibility.<\/td><\/tr>\n          <tr><td><strong>Class 3<\/strong><\/td><td>General flexibility<\/td><td>Fine-stranded conductor. Good flexibility for general-purpose dynamic use.<\/td><td>General-use cabtyre cables. Curtain festoon systems. Standard port crane applications.<\/td><\/tr>\n          <tr><td><strong>Class 4<\/strong><\/td><td>High flexibility<\/td><td>Very fine stranding approaching Class 5. Maximum flexibility for tight-radius bending.<\/td><td>High-flex applications. Small-radius sheaves. Robotic and high-cycle-rate equipment.<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>The class number has a direct impact on the cable&#8217;s mechanical performance. <strong>Class 2<\/strong> conductors resist compressive deformation (ideal for drum winding) and maintain geometry under tensile load (ideal for long festoon spans). <strong>Class 3<\/strong> provides good all-round flexibility for standard crane festoon applications. <strong>Class 4<\/strong> offers the highest flexibility for applications requiring tight bending radii and extreme cycle life. <strong>Class 1<\/strong> is rarely used in crane applications and is limited to fixed-installation scenarios.<\/p>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Special Case: Silicone Rubber (KKCT)<\/div>\n      <p>The silicone rubber cable <code class=\"cd\">KKCT<\/code> is the only JIS C 3327 designation that does <strong>not<\/strong> carry a class number prefix. Silicone rubber cables have inherently high flexibility due to the material&#8217;s extremely low elastic modulus, and the standard defines a single flexibility specification for KKCT cables rather than offering multiple classes. If you encounter a JIS cable code with no leading number, it is a silicone rubber cable.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S5 ===== -->\n  <section class=\"body\" id=\"s5\">\n    <h2>Insulation Materials: The First Variable<\/h2>\n\n    <p>The insulation material is the dielectric layer that separates the conductor from the cable&#8217;s metallic screen or sheath, providing electrical isolation at the rated voltage. JIS C 3327 defines four insulation material options:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>JIS C 3327 Insulation Materials<\/caption>\n        <thead><tr><th>Code<\/th><th>Material<\/th><th>Dielectric Strength<\/th><th>Temperature Range<\/th><th>Advantages<\/th><th>Limitations<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><code class=\"cd\">(none)<\/code><\/td><td>Natural rubber<\/td><td>~15\u201320 kV\/mm<\/td><td>\u221225\u00b0C to +60\u00b0C<\/td><td>Good flexibility, low cost, proven track record<\/td><td>Limited UV\/ozone resistance, narrower temperature range<\/td><\/tr>\n          <tr><td><code class=\"cd\">P<\/code><\/td><td>EP rubber (EPDM)<\/td><td>~20\u201330 kV\/mm<\/td><td>\u221230\u00b0C to +80\u00b0C<\/td><td>Superior dielectric strength, excellent ozone resistance, wide temperature range, &gt;1M flex cycles<\/td><td>Higher cost than natural rubber<\/td><\/tr>\n          <tr><td><code class=\"cd\">K<\/code><\/td><td>Silicone rubber<\/td><td>~15\u201325 kV\/mm<\/td><td>\u221260\u00b0C to +180\u00b0C<\/td><td>Extreme temperature range, very low smoke emission, biocompatible<\/td><td>Lower mechanical strength, higher cost, limited oil resistance<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>For port crane and ship unloader applications, <strong>EP rubber (P)<\/strong> is the industry standard insulation choice. Its combination of high dielectric strength, wide operating temperature range (\u221230\u00b0C to +80\u00b0C), ozone resistance, and ability to withstand millions of flex cycles without cracking makes it the optimal insulation for any cable that will operate in a dynamic marine terminal environment. This is why <code class=\"cd\">PNCT<\/code>-designated cables dominate the port crane market worldwide.<\/p>\n\n  <\/section>\n\n  <!-- ===== S6 ===== -->\n  <section class=\"body\" id=\"s6\">\n    <h2>Sheath Materials: The Second Variable<\/h2>\n\n    <p>The sheath (outer jacket) is the cable&#8217;s external protective layer, providing mechanical protection, environmental resistance, and\u2014in some formulations\u2014flame retardancy. JIS C 3327 defines four sheath material options:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>JIS C 3327 Sheath Materials<\/caption>\n        <thead><tr><th>Code<\/th><th>Material<\/th><th>Oil Resistance<\/th><th>Flame Retardancy<\/th><th>Advantages<\/th><th>Primary Use<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><code class=\"cd\">(none)<\/code><\/td><td>Natural rubber<\/td><td>Poor<\/td><td>Not self-extinguishing<\/td><td>Low cost, good flexibility, high abrasion resistance<\/td><td>Indoor, dry, oil-free environments<\/td><\/tr>\n          <tr><td><code class=\"cd\">R<\/code><\/td><td>Chloroprene rubber (polychloroprene)<\/td><td>Excellent<\/td><td>Self-extinguishing<\/td><td>Oil, UV, ozone, saltwater, and abrasion resistance. The complete package.<\/td><td>Port cranes, marine terminals, outdoor industrial<\/td><\/tr>\n          <tr><td><code class=\"cd\">H<\/code><\/td><td>Polyethylene chlorosulfonide (Hypalon\u00ae type)<\/td><td>Excellent<\/td><td>Self-extinguishing<\/td><td>Exceptional chemical resistance, superior UV stability, nuclear-grade<\/td><td>Chemical plants, nuclear facilities, extreme UV environments<\/td><\/tr>\n          <tr><td><code class=\"cd\">K<\/code><\/td><td>Silicone rubber<\/td><td>Poor<\/td><td>Low smoke, low toxicity<\/td><td>Extreme temperature, low smoke, suitable for confined spaces<\/td><td>High-temperature industrial, food processing, clean rooms<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>For port crane applications, <strong>chloroprene rubber (R)<\/strong> is the dominant sheath choice. Its simultaneous oil resistance, flame retardancy, UV stability, saltwater impermeability, and mechanical toughness make it the only sheath material that can survive the multi-hazard port terminal environment without compromise. This is why <code class=\"cd\">PNCT<\/code> (EP rubber insulation + chloroprene rubber sheath) is the standard specification for crane cables globally.<\/p>\n\n  <\/section>\n\n  <!-- ===== S7 ===== -->\n  <section class=\"body\" id=\"s7\">\n    <h2>Complete Classification Table: All 15 Cable Types<\/h2>\n\n    <div class=\"tw\">\n      <table>\n        <caption>JIS C 3327 \u2014 Complete Cable Code Designation Table (All 15 Types)<\/caption>\n        <thead><tr><th>Code<\/th><th>Class<\/th><th>Insulation<\/th><th>Sheath<\/th><th>Full Description<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><code class=\"cd\">1 CT<\/code><\/td><td>1<\/td><td>Natural rubber<\/td><td>Natural rubber<\/td><td>Class 1 natural rubber insulated, natural rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">2 CT<\/code><\/td><td>2<\/td><td>Natural rubber<\/td><td>Natural rubber<\/td><td>Class 2 natural rubber insulated, natural rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">3 CT<\/code><\/td><td>3<\/td><td>Natural rubber<\/td><td>Natural rubber<\/td><td>Class 3 natural rubber insulated, natural rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">4 CT<\/code><\/td><td>4<\/td><td>Natural rubber<\/td><td>Natural rubber<\/td><td>Class 4 natural rubber insulated, natural rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">2 RNCT<\/code><\/td><td>2<\/td><td>Natural rubber<\/td><td><strong>Chloroprene rubber<\/strong><\/td><td>Class 2 natural rubber insulated, chloroprene rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">3 RNCT<\/code><\/td><td>3<\/td><td>Natural rubber<\/td><td><strong>Chloroprene rubber<\/strong><\/td><td>Class 3 natural rubber insulated, chloroprene rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">4 RNCT<\/code><\/td><td>4<\/td><td>Natural rubber<\/td><td><strong>Chloroprene rubber<\/strong><\/td><td>Class 4 natural rubber insulated, chloroprene rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">2 PNCT<\/code><\/td><td>2<\/td><td><strong>EP rubber<\/strong><\/td><td><strong>Chloroprene rubber<\/strong><\/td><td>Class 2 EP rubber insulated, chloroprene rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">3 PNCT<\/code><\/td><td>3<\/td><td><strong>EP rubber<\/strong><\/td><td><strong>Chloroprene rubber<\/strong><\/td><td>Class 3 EP rubber insulated, chloroprene rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">4 PNCT<\/code><\/td><td>4<\/td><td><strong>EP rubber<\/strong><\/td><td><strong>Chloroprene rubber<\/strong><\/td><td>Class 4 EP rubber insulated, chloroprene rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">2 PHCT<\/code><\/td><td>2<\/td><td><strong>EP rubber<\/strong><\/td><td><strong>Hypalon\u00ae rubber<\/strong><\/td><td>Class 2 EP rubber insulated, polyethylene chlorosulfonide rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">3 PHCT<\/code><\/td><td>3<\/td><td><strong>EP rubber<\/strong><\/td><td><strong>Hypalon\u00ae rubber<\/strong><\/td><td>Class 3 EP rubber insulated, polyethylene chlorosulfonide rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">4 PHCT<\/code><\/td><td>4<\/td><td><strong>EP rubber<\/strong><\/td><td><strong>Hypalon\u00ae rubber<\/strong><\/td><td>Class 4 EP rubber insulated, polyethylene chlorosulfonide rubber sheathed flexible cable<\/td><\/tr>\n          <tr><td><code class=\"cd\">KKCT<\/code><\/td><td>\u2014<\/td><td><strong>Silicone rubber<\/strong><\/td><td><strong>Silicone rubber<\/strong><\/td><td>Silicone rubber insulated, silicone rubber sheathed flexible cable<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">Reading the Table: Material Combination Patterns<\/div>\n      <p>Notice the logical patterns: the <code class=\"cd\">CT<\/code> family uses natural rubber for both insulation and sheath (no material letters needed). The <code class=\"cd\">RNCT<\/code> family upgrades only the sheath to chloroprene while keeping natural rubber insulation. The <code class=\"cd\">PNCT<\/code> family upgrades the insulation to EP rubber and uses chloroprene sheath\u2014the premium combination for port crane cables. The <code class=\"cd\">PHCT<\/code> family pairs EP rubber insulation with Hypalon\u00ae sheath for extreme chemical environments. And <code class=\"cd\">KKCT<\/code> uses silicone for everything, targeting extreme temperature applications. Each step from CT \u2192 RNCT \u2192 PNCT \u2192 PHCT represents an upgrade in material performance and application capability.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S8 ===== -->\n  <section class=\"body\" id=\"s8\">\n    <h2>Decoding Examples: Reading Any JIS C 3327 Cable Name<\/h2>\n\n    <h3>Example 1: <code class=\"cd\">2PNCT<\/code><\/h3>\n    <div class=\"decode\">\n      <div class=\"seg cls\"><span class=\"val\">2<\/span><span class=\"lbl\">Class 2<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg ins\"><span class=\"val\">P<\/span><span class=\"lbl\">EP Rubber Ins.<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg sht\"><span class=\"val\">N<\/span><span class=\"lbl\">Chloroprene Sheath<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg base\"><span class=\"val\">CT<\/span><span class=\"lbl\">Flexible Cable<\/span><\/div>\n    <\/div>\n    <p><strong>Translation:<\/strong> Class 2 flexibility, EP rubber insulation, chloroprene rubber sheath, flexible cable. This is the TRACAB<span class=\"tm\">\u00ae<\/span> cable for curtain, carrier drum, and cableveyor transport systems on port cranes. Feichun equivalent: <strong>FC-2TC-RB-K\u2122<\/strong>.<\/p>\n\n    <h3>Example 2: <code class=\"cd\">3PNCT<\/code><\/h3>\n    <div class=\"decode\">\n      <div class=\"seg cls\"><span class=\"val\">3<\/span><span class=\"lbl\">Class 3<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg ins\"><span class=\"val\">P<\/span><span class=\"lbl\">EP Rubber Ins.<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg sht\"><span class=\"val\">N<\/span><span class=\"lbl\">Chloroprene Sheath<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg base\"><span class=\"val\">CT<\/span><span class=\"lbl\">Flexible Cable<\/span><\/div>\n    <\/div>\n    <p><strong>Translation:<\/strong> Class 3 flexibility, EP rubber insulation, chloroprene rubber sheath, flexible cable. The 6600V high voltage variant under JIS C 4353 is also designated 3PNCT. Feichun equivalent: <strong>FC-2PNCT-K\u2122<\/strong> (600V) or <strong>FC-3PNCT-6.6kV-K\u2122<\/strong> (6600V).<\/p>\n\n    <h3>Example 3: <code class=\"cd\">3CT<\/code><\/h3>\n    <div class=\"decode\">\n      <div class=\"seg cls\"><span class=\"val\">3<\/span><span class=\"lbl\">Class 3<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg ins\"><span class=\"val\">(none)<\/span><span class=\"lbl\">Natural Rubber Ins.<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg sht\"><span class=\"val\">(none)<\/span><span class=\"lbl\">Natural Rubber Sheath<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg base\"><span class=\"val\">CT<\/span><span class=\"lbl\">Flexible Cable<\/span><\/div>\n    <\/div>\n    <p><strong>Translation:<\/strong> Class 3 flexibility, natural rubber insulation, natural rubber sheath, flexible cable. The basic general-purpose cabtyre cable. Suitable for indoor, dry, oil-free environments only\u2014not recommended for port crane or marine terminal use.<\/p>\n\n    <h3>Example 4: <code class=\"cd\">KKCT<\/code><\/h3>\n    <div class=\"decode\">\n      <div class=\"seg cls\"><span class=\"val\">(none)<\/span><span class=\"lbl\">Single Class<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg ins\"><span class=\"val\">K<\/span><span class=\"lbl\">Silicone Rubber Ins.<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg sht\"><span class=\"val\">K<\/span><span class=\"lbl\">Silicone Rubber Sheath<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg base\"><span class=\"val\">CT<\/span><span class=\"lbl\">Flexible Cable<\/span><\/div>\n    <\/div>\n    <p><strong>Translation:<\/strong> Silicone rubber insulation, silicone rubber sheath, flexible cable. The extreme-temperature specialist: \u221260\u00b0C to +180\u00b0C operating range. Used in steelworks, glass manufacturing, foundries, and high-temperature industrial applications. Not typically used in port crane applications (limited oil resistance).<\/p>\n\n    <h3>Example 5: <code class=\"cd\">4PHCT<\/code><\/h3>\n    <div class=\"decode\">\n      <div class=\"seg cls\"><span class=\"val\">4<\/span><span class=\"lbl\">Class 4<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg ins\"><span class=\"val\">P<\/span><span class=\"lbl\">EP Rubber Ins.<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg sht\"><span class=\"val\">H<\/span><span class=\"lbl\">Hypalon\u00ae Sheath<\/span><\/div>\n      <span class=\"plus\">+<\/span>\n      <div class=\"seg base\"><span class=\"val\">CT<\/span><span class=\"lbl\">Flexible Cable<\/span><\/div>\n    <\/div>\n    <p><strong>Translation:<\/strong> Class 4 (high) flexibility, EP rubber insulation, polyethylene chlorosulfonide rubber (Hypalon\u00ae type) sheath, flexible cable. The premium specification for chemical plants, nuclear facilities, and environments requiring exceptional chemical and UV resistance beyond what chloroprene can provide.<\/p>\n\n  <\/section>\n\n  <!-- ===== S9 ===== -->\n  <section class=\"body\" id=\"s9\">\n    <h2>Extended Suffixes: SB, Light, RB &amp; Voltage Prefixes<\/h2>\n\n    <p>Beyond the core JIS C 3327 designation, cable manufacturers (including Feichun) use <strong>additional suffixes and prefixes<\/strong> to identify product variants within the same base specification. These extensions are not part of the JIS standard itself but are widely used in the industry:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>Common Extended Designations for PNCT-Family Cables<\/caption>\n        <thead><tr><th>Extended Code<\/th><th>Meaning<\/th><th>Key Addition<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><code class=\"cd\">2PNCT<\/code><\/td><td>Base designation<\/td><td>Standard Class 2 EP rubber \/ chloroprene cable (also marketed as 2TC Light)<\/td><\/tr>\n          <tr><td><code class=\"cd\">2PNCT-SB<\/code><\/td><td>Shielded variant<\/td><td>Adds tinned copper wire braided combined with cotton yarn EMI shielding<\/td><\/tr>\n          <tr><td><code class=\"cd\">2TC Light<\/code><\/td><td>Trade name for 2PNCT<\/td><td>Lightweight Class 3 general-purpose cabtyre cable. &#8220;Light&#8221; = optimised weight.<\/td><\/tr>\n          <tr><td><code class=\"cd\">2TC Light-SB<\/code><\/td><td>Shielded trade name<\/td><td>2TC Light with EMI shielding (equivalent to 2PNCT-SB)<\/td><\/tr>\n          <tr><td><code class=\"cd\">2TC-RB<\/code><\/td><td>TRACAB\u00ae multi-transport<\/td><td>Class 2 cable validated for curtain, carrier drum, and cableveyor systems<\/td><\/tr>\n          <tr><td><code class=\"cd\">600V<\/code> prefix<\/td><td>Voltage class<\/td><td>Low voltage rating. Test voltage: 3,000V \/ 1 min. Standard: JIS C 3327.<\/td><\/tr>\n          <tr><td><code class=\"cd\">6600V<\/code> prefix<\/td><td>High voltage class<\/td><td>High voltage rating. Test voltage: 17,000V \/ 10 min. Standard: JIS C 4353.<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>The <strong>-SB<\/strong> suffix stands for <em>Shielded Braided<\/em> and indicates the cable includes a metallic braid shield (tinned copper combined with cotton yarn) for electromagnetic interference containment. This suffix is essential when specifying cables for VFD-driven crane motor applications.<\/p>\n\n    <p>The <strong>voltage prefix<\/strong> (600V or 6600V) is critically important: it determines not only the insulation thickness and test voltage but also the applicable standard. <strong>600V cables<\/strong> are manufactured to JIS C 3327, while <strong>6600V cables<\/strong> are manufactured to the separate standard <strong>JIS C 4353<\/strong>, which specifies additional requirements including semiconductive stress-grading layers, metallic earth screens, dual-layer sheaths, and partial discharge testing.<\/p>\n\n  <\/section>\n\n  <!-- ===== S10 ===== -->\n  <section class=\"body\" id=\"s10\">\n    <h2>Feichun Product Cross-Reference<\/h2>\n\n    <p>Anhui Feichun Special Cable Co., Ltd. manufactures Kevlar<span class=\"tm\">\u00ae<\/span>-reinforced equivalents for the most widely used PNCT-family cables in port crane applications. The following table maps JIS designations to Feichun product codes:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>JIS Designation \u2192 Feichun Product Cross-Reference<\/caption>\n        <thead><tr><th>JIS Designation<\/th><th>Feichun Product Code<\/th><th>Voltage<\/th><th>Key Feature<\/th><th>Primary Application<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><code class=\"cd\">600V 2PNCT<\/code> (2TC Light)<\/td><td>FC-2PNCT-K\u2122<\/td><td>600V<\/td><td>Kevlar\u00ae tensile reinforcement<\/td><td>General-purpose crane festoon &amp; curtain<\/td><\/tr>\n          <tr><td><code class=\"cd\">600V 2PNCT-SB<\/code> (2TC Light-SB)<\/td><td>FC-2PNCT-SB-K\u2122<\/td><td>600V<\/td><td>Kevlar\u00ae + EMI shield<\/td><td>VFD-driven crane motors, EMI-sensitive systems<\/td><\/tr>\n          <tr><td><code class=\"cd\">600V 2TC-RB<\/code><\/td><td>FC-2TC-RB-K\u2122<\/td><td>600V<\/td><td>Kevlar\u00ae + TRACAB\u00ae transport<\/td><td>Curtain, carrier drum, &amp; cableveyor systems<\/td><\/tr>\n          <tr><td><code class=\"cd\">6600V 3PNCT<\/code><\/td><td>FC-3PNCT-6.6kV-K\u2122<\/td><td>6600V<\/td><td>Kevlar\u00ae + semiconductive layer + dual sheath<\/td><td>Large STS cranes, ship unloaders &gt;500 kW<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>All Feichun equivalents add <strong>Kevlar<span class=\"tm\">\u00ae<\/span> para-aramid fibre braided tensile reinforcement<\/strong>\u2014a feature not specified by the base JIS standard but essential for the dynamic mechanical demands of port crane festoon, reeling, and cableveyor applications. The Kevlar<span class=\"tm\">\u00ae<\/span> layer provides 5\u00d7 the tensile strength of steel per unit weight, absorbing self-weight catenary loads and dynamic forces without transferring mechanical stress to the conductors or insulation system.<\/p>\n\n  <\/section>\n\n  <!-- ===== S11 ===== -->\n  <section class=\"body\" id=\"s11\">\n    <h2>Quick-Reference Decoding Chart<\/h2>\n\n    <p>Cut out and keep\u2014a single-glance reference for decoding any JIS C 3327 cable name:<\/p>\n\n    <div class=\"tw\">\n      <table>\n        <caption>JIS C 3327 \u2014 Quick-Reference Decoding Chart<\/caption>\n        <thead><tr><th>Position<\/th><th>What It Tells You<\/th><th>Possible Values<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td><strong>First character(s)<\/strong><\/td><td>Flexibility class<\/td><td><code class=\"cd\">1<\/code> = rigid \u00b7 <code class=\"cd\">2<\/code> = moderate \u00b7 <code class=\"cd\">3<\/code> = general \u00b7 <code class=\"cd\">4<\/code> = high \u00b7 (none) = silicone<\/td><\/tr>\n          <tr><td><strong>Letters before CT<\/strong><\/td><td>Material codes<\/td><td>(none) = natural rubber \u00b7 <code class=\"cd\">P<\/code> = EP rubber \u00b7 <code class=\"cd\">R<\/code> = chloroprene \u00b7 <code class=\"cd\">N<\/code> = natural rubber (explicit) \u00b7 <code class=\"cd\">H<\/code> = Hypalon\u00ae \u00b7 <code class=\"cd\">K<\/code> = silicone<\/td><\/tr>\n          <tr><td><strong>Last two characters<\/strong><\/td><td>Cable category<\/td><td><code class=\"cd\">CT<\/code> = flexible cable (cabtyre) \u2014 always present<\/td><\/tr>\n          <tr><td><strong>Suffix after code<\/strong><\/td><td>Variant identifier<\/td><td><code class=\"cd\">-SB<\/code> = shielded braided \u00b7 <code class=\"cd\">-RB<\/code> = TRACAB\u00ae multi-transport \u00b7 <code class=\"cd\">Light<\/code> = optimised weight<\/td><\/tr>\n          <tr><td><strong>Voltage prefix<\/strong><\/td><td>Voltage class &amp; standard<\/td><td><code class=\"cd\">600V<\/code> = JIS C 3327 \u00b7 <code class=\"cd\">6600V<\/code> = JIS C 4353<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">The One Rule That Decodes Everything<\/div>\n      <p>If you remember nothing else from this guide, remember this: <strong>read the code as Class + Insulation + Sheath + CT<\/strong>. The class is the leading number. The insulation code is the first letter. The sheath code is the second letter (or the first letter, if only one material code is present and the insulation is implied as natural rubber). And <code class=\"cd\">CT<\/code> always means flexible cable. Absent letters default to natural rubber. With this single rule, you can decode all 15 cable types defined by JIS C 3327.<\/p>\n    <\/div>\n\n  <\/section>\n\n  <!-- ===== S12 ===== -->\n  <section class=\"refs\" id=\"s12\">\n    <h2>References &amp; Standards<\/h2>\n    <ol class=\"rl\">\n      <li>JIS C 3327, <em>600 V Rubber Insulated Cabtyre Cables<\/em> \u2014 Japanese Industrial Standard (covers Classes 1\u20134, all material combinations).<\/li>\n      <li>JIS C 4353, <em>6600 V EP Rubber Insulated Polychloroprene Sheathed Cabtyre Cables (3PNCT)<\/em> \u2014 Japanese Industrial Standard (high voltage variant).<\/li>\n      <li>JIS C 3005, <em>Test methods for rubber and plastics insulated wires and cables<\/em>.<\/li>\n      <li>IEC 60228, <em>Conductors of insulated cables \u2014 Classification and construction requirements (Classes 1\u20136)<\/em>.<\/li>\n      <li>IEC 60811-1-1, <em>Insulating and sheathing materials of electric and optical cables \u2014 Common test methods<\/em>.<\/li>\n      <li>DuPont\u2122 Kevlar\u00ae Technical Guide, <em>Properties and Applications of Kevlar\u00ae Aramid Fibre<\/em>.<\/li>\n      <li>ISO 9001:2015, <em>Quality management systems \u2014 Requirements<\/em>.<\/li>\n    <\/ol>\n  <\/section>\n\n  <div class=\"contact\">\n    <h3>Contact Anhui Feichun Special Cable Co., Ltd. \u2014 Japanese-Standard Cable Specialists<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\"><span class=\"lb\">Technical Specifications &amp; Cable Selection<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">JIS-Standard Cable Procurement &amp; Quotations<\/span><a href=\"mailto:Tech@feichuncables.com\">Tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">24\/7 Emergency Technical Support<\/span>+86 138 5608 5607<\/div>\n      <div class=\"ci\"><span class=\"lb\">Technical WhatsApp &amp; WeChat<\/span>+86 138 5512 3218<\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>This reference guide explains the JIS C 3327 cable code designation system used across the Japanese Industrial Standard flexible cable family, covering all 15 cable types from 1CT through KKCT, with detailed symbol decoding, flexibility class explanations, insulation and sheath material comparisons, worked decoding examples, extended suffix definitions, and cross-references to Feichun&#8217;s Kevlar\u00ae-reinforced equivalent product range. Intended as a permanent reference for engineers, specifiers, and procurement professionals working with Japanese-standard port crane cables, ship unloader cables, and industrial flexible power cables. Kevlar\u00ae is a registered trademark of DuPont de Nemours, Inc. Hypalon\u00ae is a registered trademark of DuPont de Nemours, Inc. Neoprene\u00ae is a registered trademark of DuPont de Nemours, Inc. TRACAB\u00ae is a registered trademark. All product information is approximate and subject to manufacturing tolerances.<\/p>\n    <p style=\"margin-top:.5rem;\">\u00a9 2026 Anhui Feichun Special Cable Co., Ltd. All rights reserved.<\/p>\n  <\/footer>\n\n<\/div>\n<\/body>\n<\/html>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/495952196-JIS-C3327.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u5d4c\u5165 495952196-JIS-C3327\"><\/object><a id=\"wp-block-file--media-d624e833-cc5f-414c-838a-42e760bce8b3\" href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/495952196-JIS-C3327.pdf\">495952196-JIS-C3327<\/a><a href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/495952196-JIS-C3327.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-d624e833-cc5f-414c-838a-42e760bce8b3\">\u4e0b\u8f7d<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"JIS C 3327 designation system is elegant in its logic. Every cable name follows a predictable, parseable structure where each character or character group carries a specific, unambiguous meaning. Once you understand the five material symbols and the four flexibility classes, you can decode any of the 15 cable types defined by the standard\u2014and immediately know what the cable is made of, how flexible it is, and what applications it is suited for.","protected":false},"author":1,"featured_media":10334,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"categories":[66,94,464,56],"tags":[52012,3032,51949,51996,52017,52024,52039,52020,52014,52013,52044,52027,52043,52028,52015,52031,52023,52035,52016,52042,52021,27505,4522,52037,52033,52032,52018,52041,52038,52019,51953,52029,52040,52026,52045,52010,2923,465,52030,51965,52034,467,24060,52036,52011,52022,52025,15180,3231],"class_list":["post-10333","post","type-post","status-publish","format-standard","has-post-thumbnail","category-common-problems-encountered-in-cable-applications","category-din-vde-0250-mining-cable","category-flexible-cables-with-high-bending-life-and-fatigue-resistance","category-reeling-cable","tag-2pnct-code","tag-2pnct-sb","tag-2tc-light","tag-2tc-rb","tag-3pnct-code","tag-600v-cable-designation","tag-6600v-3pnct","tag-cable-class-1-2-3-4","tag-cable-classification","tag-cable-code-designation","tag-cable-code-structure","tag-cable-designation-guide","tag-cable-insulation-code","tag-cable-material-codes","tag-cable-naming-convention","tag-cable-sheath-code","tag-cable-symbol-meaning","tag-cable-type-classification","tag-cabtyre-cable","tag-cabtyre-definition","tag-chloroprene-rubber-cable-code","tag-chloroprene-sheath","tag-class-2-cable","tag-class-3-cable","tag-class-4-cable","tag-conductor-flexibility-class","tag-ct-flexible-cable","tag-ct-suffix-meaning","tag-decode-jis-cable","tag-ep-rubber-cable-code","tag-ep-rubber-insulation","tag-feichun-cable-reference","tag-flexible-cable-standard","tag-hypalon-sheath","tag-japanese-cable-naming-system","tag-japanese-cable-standard","tag-japanese-industrial-standard-cable","tag-jis-c-3327","tag-jis-c-3327-decoding","tag-jis-c-4353","tag-kkct-cable","tag-natural-rubber-cable","tag-natural-rubber-insulation","tag-phct-cable","tag-pnct-meaning","tag-port-crane-cable-specification","tag-rnct-cable","tag-silicone-rubber-cable","tag-tracab-cable","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=10333"}],"version-history":[{"count":1,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10333\/revisions"}],"predecessor-version":[{"id":10336,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/posts\/10333\/revisions\/10336"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media\/10334"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=10333"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/categories?post=10333"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/tags?post=10333"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}