{"id":2281,"date":"2025-11-19T11:36:02","date_gmt":"2025-11-19T03:36:02","guid":{"rendered":"https:\/\/feichuncables.com\/blog\/?page_id=2281"},"modified":"2026-03-10T10:21:32","modified_gmt":"2026-03-10T02:21:32","slug":"what-is-mining-trailing-cable","status":"publish","type":"page","link":"https:\/\/feichuncables.com\/blog\/what-is-mining-trailing-cable\/","title":{"rendered":"What is Mining Trailing Cable?"},"content":{"rendered":"\n<!DOCTYPE html>\n<html lang=\"en\">\n<head>\n<meta charset=\"UTF-8\">\n<meta name=\"viewport\" content=\"width=device-width, initial-scale=1.0\">\n<title>What Is Mining Trailing Cable? Comprehensive Technical Guide to Specifications, Standards, and Applications | Feichun Cable<\/title>\n<meta name=\"description\" content=\"Complete technical guide to mining trailing cables: what they are, how they're constructed, which standards apply (AS\/NZS 1802, ICEA S-75-381, 30 CFR Part 75), EPR insulation vs XLPE, CPE vs PCP sheath materials, cable types (Type W, Type G-GC, Type SHD-GC, Type 240, Type 275), voltage ratings from 600V to 22kV, ampacity tables, equipment compatibility (continuous miners, shuttle cars, draglines), tropical considerations, and selection criteria. With 34 references.\">\n<meta name=\"keywords\" content=\"mining trailing cable, what is trailing cable, trailing cable definition, mining cable types, Type W mining cable, Type G-GC mining cable, Type SHD-GC mining cable, Type MP-GC mining cable, Type 240 mining cable, Type 275 mining cable, AS\/NZS 1802, ICEA S-75-381, NEMA WC 58, 30 CFR Part 75, MSHA trailing cable, EPR insulation mining, CPE sheath mining cable, mining cable construction, continuous miner cable, shuttle car cable, dragline cable, mining shovel cable, underground mining cable, surface mining cable, trailing cable specifications, trailing cable ampacity, mining cable voltage rating, flame retardant mining cable, ground check conductor, pilot conductor mining cable, semiconductive screen cable, mining cable standards, coal mine cable, metal mine cable, tropicalized mining cable, mining cable selection guide, \u77ff\u7528\u62d6\u66f3\u7535\u7f06, \u62d6\u66f3\u7535\u7f06\u662f\u4ec0\u4e48, \u77ff\u7528\u7535\u7f06\u6807\u51c6, AS\/NZS 1802\u77ff\u7528\u7535\u7f06\">\n<meta name=\"author\" content=\"Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8\">\n<meta name=\"robots\" content=\"index, follow\">\n<link rel=\"canonical\" href=\"https:\/\/feichuncables.com\/blog\/what-is-mining-trailing-cable-comprehensive-guide\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.googleapis.com\">\n<link rel=\"preconnect\" href=\"https:\/\/fonts.gstatic.com\" crossorigin>\n<link href=\"https:\/\/fonts.googleapis.com\/css2?family=Source+Serif+4:ital,wght@0,400;0,600;0,700;0,800;1,400&#038;family=Instrument+Sans:wght@400;500;600;700&#038;family=IBM+Plex+Mono:wght@400;500&#038;display=swap\" rel=\"stylesheet\">\n<style>:root{color-scheme:light dark;--bg-body:#F5F3EE;--bg-surface:#FFFFFF;--bg-recessed:#EDEAE4;--bg-code:#F0EDE7;--bg-th:#1C1C1C;--bg-tr-alt:#F8F6F2;--bg-callout-blue:#EBF3FD;--bg-callout-amber:#FFF8E6;--bg-callout-green:#E9F7EF;--bg-callout-red:#FDE8E8;--c-body:#222222;--c-secondary:#4D4D4D;--c-tertiary:#777777;--c-inverse:#FFFFFF;--c-cn:#666666;--c-link:#9B5A12;--c-link-hover:#734210;--c-accent:#B8860B;--b-rule:#D8D5CE;--b-light:#E8E5DF;--b-accent:#B8860B;--b-table:#CBC8C1;--sh-sm:0 1px 2px rgba(0,0,0,0.05);--sh-md:0 3px 10px rgba(0,0,0,0.07);--sh-table:0 1px 4px rgba(0,0,0,0.06);--badge-bg:#1C1C1C;--badge-c:#FFFFFF;--hl-green:#E1F5E6;--hl-red:#FDE8E1;--hl-blue:#E1EDFA;--hl-amber:#FFF3D0;}@media(prefers-color-scheme:dark){:root{--bg-body:#111111;--bg-surface:#1A1A1A;--bg-recessed:#222222;--bg-code:#252525;--bg-th:#282828;--bg-tr-alt:#161616;--bg-callout-blue:#162030;--bg-callout-amber:#25200E;--bg-callout-green:#142218;--bg-callout-red:#2A1714;--c-body:#E2E0DB;--c-secondary:#ADABA6;--c-tertiary:#888683;--c-inverse:#111111;--c-cn:#908E89;--c-link:#D9A63E;--c-link-hover:#EDC462;--c-accent:#D9A63E;--b-rule:#333333;--b-light:#2A2A2A;--b-accent:#D9A63E;--b-table:#363636;--sh-sm:0 1px 2px rgba(0,0,0,0.25);--sh-md:0 3px 10px rgba(0,0,0,0.35);--sh-table:0 1px 4px rgba(0,0,0,0.3);--badge-bg:#D9A63E;--badge-c:#111111;--hl-green:#16291A;--hl-red:#2A1714;--hl-blue:#162030;--hl-amber:#25200E;}}*{box-sizing:border-box;margin:0;padding:0}html{font-size:16px;scroll-behavior:smooth}body{font-family:'Instrument Sans',-apple-system,BlinkMacSystemFont,sans-serif;background:var(--bg-body);color:var(--c-body);line-height:1.8}.page-wrap{max-width:880px;margin:0 auto;padding:2.5rem 1.25rem 4rem}.hdr{padding-bottom:2rem;margin-bottom:2.5rem;border-bottom:2px solid var(--b-accent)}.hdr .badge{display:inline-block;background:var(--badge-bg);color:var(--badge-c);font-size:.68rem;font-weight:700;letter-spacing:.12em;text-transform:uppercase;padding:.3em 1em;border-radius:2px;margin-bottom:1rem}.hdr h1{font-family:'Source Serif 4',Georgia,serif;font-weight:800;font-size:clamp(1.55rem,3.8vw,2.25rem);line-height:1.22;color:var(--c-body);margin-bottom:.65rem}.hdr .sub{font-size:1rem;color:var(--c-secondary);line-height:1.6;margin-bottom:.4rem}.hdr .sub-cn{font-size:.85rem;color:var(--c-cn);line-height:1.6;font-style:italic}.meta{display:flex;flex-wrap:wrap;gap:1rem;margin-top:1.1rem;font-size:.78rem;color:var(--c-tertiary)}.toc{background:var(--bg-surface);border:1px solid var(--b-rule);border-radius:4px;padding:1.2rem 1.4rem;margin-bottom:2.8rem;box-shadow:var(--sh-sm)}.toc-label{font-weight:700;font-size:.72rem;letter-spacing:.1em;text-transform:uppercase;color:var(--c-tertiary);margin-bottom:.55rem}.toc ol{list-style:none;counter-reset:tc;padding:0}.toc li{counter-increment:tc;margin-bottom:.25rem}.toc li::before{content:counter(tc) \".\";font-weight:600;font-family:'IBM Plex Mono',monospace;font-size:.78rem;margin-right:.45em;color:var(--c-tertiary)}.toc a{font-size:.86rem;color:var(--c-secondary);text-decoration:none}.toc a:hover{color:var(--c-link);text-decoration:underline}.body h2{font-family:'Instrument Sans',sans-serif;font-weight:700;font-size:1.32rem;color:var(--c-body);margin:2.8rem 0 .9rem;padding-bottom:.35rem;border-bottom:1px solid var(--b-light)}.body h3{font-weight:600;font-size:1.05rem;color:var(--c-body);margin:1.7rem 0 .55rem}.body p{margin-bottom:1.15rem;color:var(--c-secondary)}.body .cn{font-size:.84rem;color:var(--c-cn);margin-top:-.55rem;margin-bottom:1.15rem;padding-left:1rem;border-left:2px solid var(--b-light);font-style:italic}.body a{color:var(--c-link);text-decoration:underline;text-underline-offset:2px}.body a:hover{color:var(--c-link-hover)}.body strong{font-weight:600;color:var(--c-body)}.eq{display:block;text-align:center;font-family:'IBM Plex Mono',monospace;font-size:.92rem;padding:1rem;margin:1.2rem 0;background:var(--bg-recessed);border-radius:4px;color:var(--c-body);line-height:1.6;overflow-x:auto}.tw{width:100%;overflow-x:auto;margin:1.4rem 0 2rem;border:1px solid var(--b-table);border-radius:4px;box-shadow:var(--sh-table)}.tw table{width:100%;border-collapse:collapse;font-size:.86rem;line-height:1.5}.tw caption{text-align:left;font-weight:600;font-size:.78rem;letter-spacing:.04em;text-transform:uppercase;color:var(--c-tertiary);padding:.75rem 1rem .35rem;background:var(--bg-surface);border-bottom:1px solid var(--b-light)}.tw thead th{background:var(--bg-th);color:var(--c-inverse);font-weight:600;font-size:.76rem;letter-spacing:.03em;text-transform:uppercase;padding:.65rem 1rem;text-align:left;white-space:nowrap;border-bottom:2px solid var(--b-accent)}.tw tbody td{padding:.55rem 1rem;border-bottom:1px solid var(--b-light);color:var(--c-secondary);vertical-align:top}.tw tbody tr:nth-child(even){background:var(--bg-tr-alt)}.tw tbody tr:hover{background:var(--bg-callout-amber)}.tw tbody td:first-child{font-weight:500;color:var(--c-body)}.tw .g{background:var(--hl-green)}.tw .r{background:var(--hl-red)}.tw .b{background:var(--hl-blue)}.tw .a{background:var(--hl-amber)}.note{padding:1rem 1.2rem;margin:1.5rem 0;border-radius:0 4px 4px 0;font-size:.9rem;border-left:3px solid var(--b-accent)}.note.blue{background:var(--bg-callout-blue)}.note.amber{background:var(--bg-callout-amber)}.note.green{background:var(--bg-callout-green)}.note.red{background:var(--bg-callout-red)}.note .nt{font-weight:700;font-size:.78rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-body);margin-bottom:.3rem}.note p{margin-bottom:.35rem;color:var(--c-secondary)}.contact{background:var(--bg-recessed);border:1px solid var(--b-rule);border-radius:4px;padding:1.5rem;margin-top:2.5rem}.contact h3{font-size:.98rem;margin-bottom:.7rem;color:var(--c-body)}.cg{display:grid;grid-template-columns:repeat(auto-fit,minmax(210px,1fr));gap:.75rem}.ci{font-size:.83rem;color:var(--c-secondary);line-height:1.45}.ci .lb{font-weight:600;font-size:.7rem;letter-spacing:.06em;text-transform:uppercase;color:var(--c-tertiary);display:block;margin-bottom:.1rem}.ci a{color:var(--c-link);text-decoration:none}.ft{margin-top:2rem;padding-top:1.5rem;border-top:1px solid var(--b-light);font-size:.75rem;color:var(--c-tertiary);text-align:center;line-height:1.55}@media(max-width:600px){.page-wrap{padding:1.2rem 1rem 3rem}.hdr h1{font-size:1.35rem}}<\/style>\n\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechArticle\",\"headline\":\"What Is Mining Trailing Cable? Comprehensive Technical Guide to Specifications, Standards, and Applications\",\"description\":\"Complete technical guide to mining trailing cables covering construction, insulation materials (EPR, XLPE), sheath materials (CPE, PCP), cable types per AS\/NZS 1802 and ICEA S-75-381, voltage ratings, ampacity, equipment compatibility, and tropical considerations.\",\"author\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\",\"url\":\"https:\/\/www.feichuncables.com\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"Anhui Feichun Special Cable Co., Ltd.\"},\"datePublished\":\"2026-03-10\",\"dateModified\":\"2026-03-10\",\"mainEntityOfPage\":\"https:\/\/feichuncables.com\/blog\/what-is-mining-trailing-cable-comprehensive-guide\",\"inLanguage\":[\"en\",\"zh\"]}\n<\/script>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"BreadcrumbList\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/feichuncables.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\/\/feichuncables.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"What Is Mining Trailing Cable?\",\"item\":\"https:\/\/feichuncables.com\/blog\/what-is-mining-trailing-cable-comprehensive-guide\"}]}\n<\/script>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"What is a mining trailing cable?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A mining trailing cable is a heavy-duty flexible power cable designed to be dragged on the ground behind moving mining machinery such as continuous miners, shuttle cars, draglines, mining shovels, and load-haul-dump machines. Unlike fixed-installation cables, trailing cables must withstand continuous ground-contact abrasion, equipment crossover crushing, rock-edge cutting, falling-material impact, and exposure to acidic mine water \u2014 while providing reliable power delivery and meeting stringent safety requirements for flame retardancy and ground-fault monitoring in potentially explosive underground atmospheres.\"}},\n{\"@type\":\"Question\",\"name\":\"What are the main types of mining trailing cables?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Mining trailing cables are classified by standards and construction: Under ICEA S-75-381\/NEMA WC 58 (North America): Type W (portable power, 2kV), Type G-GC (portable with ground-check, 2kV), Type SHD-GC (shielded with ground-check, 5\/8\/15\/25kV), and Type MP-GC (mine power feeder with ground-check, 5\/8\/15\/25kV). Under AS\/NZS 1802 (Australia, New Zealand, and influenced markets): Type 240 (general trailing, 1.1\u201311kV), Type 241 (reeling service), and Type 275 (IT-earthed systems, 3.3\/3.3kV\u20136.6\/6.6kV). Under DIN VDE 0250 (European\/German): (N)TSCGECWOEU and similar designations for medium-voltage mining trailing cables.\"}},\n{\"@type\":\"Question\",\"name\":\"What insulation material is used in mining trailing cables?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ethylene Propylene Rubber (EPR) is the dominant insulation material for mining trailing cables due to its superior flexibility (critical for cables that must bend during trailing service), excellent dielectric properties, good thermal stability up to 90\u00b0C continuous operation, low sensitivity to water treeing compared to XLPE, and resistance to environmental degradation. XLPE (cross-linked polyethylene) is used in some mine power feeder cables (Type MP-GC) where flexibility is less critical. Standard EPR uses peroxide cross-linking, while hydrolysis-resistant EPR for tropical environments uses silane-modified cross-linking.\"}},\n{\"@type\":\"Question\",\"name\":\"What sheath material is used on mining trailing cables?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Chlorinated Polyethylene (CPE) is the most common sheath material for mining trailing cables, providing inherent flame retardancy from chlorine content, excellent abrasion and crush resistance, and good chemical resistance to mine water. Polychloroprene (PCP\/Neoprene) is used in some constructions, particularly for extra-heavy-duty applications. Polyurethane (PUR) is used for specialized applications requiring extreme cold resistance (to -50\u00b0C) or superior abrasion resistance. Sheath thickness for trailing cables typically ranges from 3.5 to 6.0mm \u2014 substantially thicker than reeling cable sheaths.\"}},\n{\"@type\":\"Question\",\"name\":\"What standards govern mining trailing cables?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Key standards include: ICEA S-75-381\/NEMA WC 58 (North America \u2014 portable and power feeder cables for mines), AS\/NZS 1802:2003 (Australia\/New Zealand \u2014 trailing cables for mining), DIN VDE 0250 (Europe \u2014 flexible cables including mining types), IEC 60502 (international \u2014 power cables with extruded insulation), and 30 CFR Part 75 Subpart G (US Federal \u2014 mandatory safety standards for trailing cables in underground coal mines, enforced by MSHA). Each standard specifies requirements for conductor construction, insulation, shielding, sheath, flame resistance, and testing.\"}},\n{\"@type\":\"Question\",\"name\":\"What is the difference between a trailing cable and a reeling cable?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A trailing cable is dragged on the ground behind mining machinery, engineered for external attack resistance (abrasion, crushing, cutting, impact) with thick CPE\/EPR sheaths. A reeling cable is wound and unwound on a cable drum, engineered for internal fatigue resistance (tension, torsion, dynamic bending) with flexible PUR sheaths, aramid strength members, and anti-torsion braids. They solve fundamentally different mechanical problems and cannot be interchanged \u2014 a trailing cable on a reel causes fatigue failure; a reeling cable on the ground causes rapid sheath destruction.\"}},\n{\"@type\":\"Question\",\"name\":\"What is a ground-check conductor in a mining trailing cable?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A ground-check conductor (also called pilot conductor or monitoring conductor) is a small-gauge conductor (typically 10\u201316 AWG or 1.5\u201316mm\u00b2) located at the center of the mining trailing cable. It carries a low-voltage monitoring signal (typically 10\u201320V DC) from the earth-fault monitoring relay. If the cable is damaged, cut, or if the ground circuit is interrupted, the monitoring relay detects the loss of pilot continuity and trips the power circuit \u2014 de-energizing the cable before a hazardous condition develops. Ground-check conductors are mandated by MSHA (30 CFR \u00a775.603), AS\/NZS 1802, and equivalent mining safety regulations worldwide.\"}},\n{\"@type\":\"Question\",\"name\":\"What voltage ratings are available for mining trailing cables?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Mining trailing cables are manufactured at multiple voltage ratings: Low voltage \u2014 600V, 1,000V, 1.1\/1.1kV, 2,000V for drill rigs, pumps, fans, and auxiliary equipment. Medium voltage \u2014 3.3\/3.3kV, 3.6\/6kV, 5kV, 6.6\/6.6kV for continuous miners, shuttle cars, and LHD machines. High voltage \u2014 8kV, 10kV, 11kV, 15kV for large mining shovels and draglines. Extra-high voltage \u2014 22kV, 25kV for very large draglines and walking draglines. The specific voltage rating depends on the mine's electrical distribution system and the equipment's power requirements.\"}},\n{\"@type\":\"Question\",\"name\":\"How long do mining trailing cables last?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Mining trailing cable service life varies dramatically based on environment, handling, and cable quality. In temperate underground coal mines with good cable handling practices, well-maintained trailing cables typically provide 18\u201336 months of service. In aggressive tropical environments (Indonesia, PNG) with high humidity, acidic mine water, and rough handling, standard cables may last only 6\u201318 months, while tropicalized cables (tinned copper, hydrolysis-resistant EPR, water-blocking, CPE sheath) can extend service life to 24\u201348 months. Surface mining cables for large shovels and draglines, which experience less severe handling but more UV and weather exposure, typically last 24\u201360 months depending on sheath quality.\"}},\n{\"@type\":\"Question\",\"name\":\"What equipment uses mining trailing cables?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Mining trailing cables provide power to all mobile mining equipment including: continuous miners (the primary application for medium-voltage trailing cables), shuttle cars, load-haul-dump (LHD) machines, roof bolters, underground drill rigs, mining shovels and excavators (surface), draglines and walking draglines (surface), tunnel boring machines (TBMs), mobile conveyors, mobile crushers, and longwall mining equipment. Each equipment type has specific cable requirements for voltage, conductor size, flexibility, and environmental protection.\"}}\n]}\n<\/script>\n<\/head>\n\n<body>\n<article class=\"page-wrap\" itemscope itemtype=\"https:\/\/schema.org\/TechArticle\">\n\n  <header class=\"hdr\">\n    <span class=\"badge\">Feichun Special Cable \u2014 Mining Cable Engineering Knowledge Base<\/span>\n    <h1 itemprop=\"headline\">What Is Mining Trailing Cable?<br>Comprehensive Technical Guide to Specifications, Standards, and Applications<\/h1>\n    <p class=\"sub\" itemprop=\"description\">Everything an Electrical Engineer, Mine Supervisor, or Procurement Specialist Needs to Know About Mining Trailing Cables: Definition and Operating Principle. Layer-by-Layer Construction Analysis. Insulation Materials (EPR vs XLPE). Sheath Materials (CPE vs PCP vs PUR). Cable Types by Standard (AS\/NZS 1802 Type 240\/275, ICEA S-75-381 Type W\/G-GC\/SHD-GC\/MP-GC, DIN VDE 0250). Voltage Ratings from 600V to 22kV. Ampacity and Derating for Tropical Conditions. Ground-Check and Pilot Conductor Systems. Equipment Compatibility Matrix. Regulatory Framework (MSHA 30 CFR Part 75, AS\/NZS, IEC). Tropical Considerations for Indonesia and PNG. Selection Criteria and Procurement Guidance.<\/p>\n    <p class=\"sub-cn\">\u7535\u6c14\u5de5\u7a0b\u5e08\u3001\u77ff\u5c71\u4e3b\u7ba1\u548c\u91c7\u8d2d\u4e13\u5bb6\u9700\u8981\u4e86\u89e3\u7684\u77ff\u7528\u62d6\u66f3\u7535\u7f06\u5168\u90e8\u77e5\u8bc6\uff1a\u5b9a\u4e49\u4e0e\u5de5\u4f5c\u539f\u7406\u3001\u9010\u5c42\u7ed3\u6784\u5206\u6790\u3001\u7edd\u7f18\u6750\u6599\uff08EPR vs XLPE\uff09\u3001\u62a4\u5957\u6750\u6599\uff08CPE vs PCP vs PUR\uff09\u3001\u5404\u6807\u51c6\u4e0b\u7684\u7535\u7f06\u7c7b\u578b\uff08AS\/NZS 1802 Type 240\/275\u3001ICEA S-75-381 Type W\/G-GC\/SHD-GC\/MP-GC\u3001DIN VDE 0250\uff09\u3001600V\u81f322kV\u7535\u538b\u7b49\u7ea7\u3001\u70ed\u5e26\u6761\u4ef6\u4e0b\u7684\u8f7d\u6d41\u91cf\u964d\u5bb9\u3001\u63a5\u5730\u76d1\u6d4b\u4e0e\u5f15\u5bfc\u5bfc\u4f53\u7cfb\u7edf\u3001\u8bbe\u5907\u517c\u5bb9\u77e9\u9635\u3001\u6cd5\u89c4\u6846\u67b6\uff08MSHA 30 CFR Part 75\u3001AS\/NZS\u3001IEC\uff09\u3001\u5370\u5c3c\u548cPNG\u70ed\u5e26\u8003\u91cf\u3001\u9009\u578b\u6807\u51c6\u4e0e\u91c7\u8d2d\u6307\u5357\u3002<\/p>\n    <div class=\"meta\">\n      <span itemprop=\"author\">Anhui Feichun Special Cable Co., Ltd.<\/span> | <time datetime=\"2026-03-10\" itemprop=\"datePublished\">Mar 10, 2026<\/time> | <span>Reading time: ~45 min<\/span>\n    <\/div>\n  <\/header>\n\n  <nav class=\"toc\" aria-label=\"Table of Contents\">\n    <div class=\"toc-label\">Contents<\/div>\n    <ol>\n      <li><a href=\"#s1\">What Is a Mining Trailing Cable? Definition and Operating Principle<\/a><\/li>\n      <li><a href=\"#s2\">How Is a Mining Trailing Cable Constructed? Layer-by-Layer Analysis<\/a><\/li>\n      <li><a href=\"#s3\">What Insulation Materials Are Used? EPR vs XLPE<\/a><\/li>\n      <li><a href=\"#s4\">What Sheath Materials Are Used? CPE vs PCP vs PUR<\/a><\/li>\n      <li><a href=\"#s5\">What Are the Cable Types? Classification by Standard<\/a><\/li>\n      <li><a href=\"#s6\">What Voltage Ratings Are Available?<\/a><\/li>\n      <li><a href=\"#s7\">What Is the Ampacity of Mining Trailing Cables?<\/a><\/li>\n      <li><a href=\"#s8\">What Is a Ground-Check Conductor and Why Is It Required?<\/a><\/li>\n      <li><a href=\"#s9\">What Standards Govern Mining Trailing Cables?<\/a><\/li>\n      <li><a href=\"#s10\">Which Mining Equipment Uses Trailing Cables?<\/a><\/li>\n      <li><a href=\"#s11\">How Does a Trailing Cable Differ from a Reeling Cable?<\/a><\/li>\n      <li><a href=\"#s12\">What Are the Mechanical Requirements for Trailing Service?<\/a><\/li>\n      <li><a href=\"#s13\">What Happens in Tropical Mining Environments?<\/a><\/li>\n      <li><a href=\"#s14\">How to Select the Right Mining Trailing Cable<\/a><\/li>\n      <li><a href=\"#s15\">Feichun Cable Mining Trailing Cable Products<\/a><\/li>\n      <li><a href=\"#s16\">References and Further Reading<\/a><\/li>\n    <\/ol>\n  <\/nav>\n\n  <div class=\"body\">\n\n    <h2 id=\"s1\">1. What Is a Mining Trailing Cable? Definition and Operating Principle<\/h2>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Direct Answer<\/div>\n      <p>A <strong>mining trailing cable<\/strong> is a heavy-duty flexible power cable designed to be dragged on the ground behind moving mining machinery. Unlike fixed-installation cables that remain stationary after installation, trailing cables move continuously with the equipment they power \u2014 being pulled, dragged, bent around corners, driven over by other equipment, and exposed to the full range of mechanical and chemical abuse that underground and surface mining environments inflict. The cable must deliver reliable electrical power while surviving this continuous physical punishment and meeting stringent safety requirements for flame retardancy and ground-fault monitoring in potentially explosive atmospheres.<\/p>\n    <\/div>\n\n    <p>The term &#8220;trailing&#8221; describes the cable&#8217;s relationship to the machine it serves: the cable literally trails behind the machine as it moves through the mine. When a continuous miner advances into a coal seam, the trailing cable pays out behind it, lying on the mine floor. When a shuttle car travels between the mining face and the conveyor belt, its trailing cable drags along the roadway. When a dragline repositions in an open pit, hundreds of meters of heavy trailing cable are dragged across the pit floor. In every case, the cable is the machine&#8217;s lifeline \u2014 the sole electrical connection between the mobile equipment and the stationary power distribution system.<\/p>\n\n    <p>This operating mode creates a mechanical stress profile that is fundamentally different from any other cable application. The cable&#8217;s outer surface is under constant environmental assault: abrasion from ground drag across rough rock surfaces, crushing from equipment tires and tracks driving over the cable, cutting from sharp rock fragments and bolt ends, impact from falling material and roof falls, and chemical attack from acidic mine water, hydraulic fluid leaks, and diesel fuel spillage. The cable must survive all of these simultaneous stresses while maintaining electrical integrity sufficient to safely deliver power at voltages up to 22kV in atmospheres that may contain explosive concentrations of methane gas and coal dust.<\/p>\n\n    <p>According to research published by PMC (National Center for Biotechnology Information), cable-related electrical incidents remain a significant safety concern in mining operations. A study on insulation monitoring technology documented that the harsh underground environment \u2014 with air humidity generally exceeding 90%, frequent dripping and drenching, poor heat dissipation, and high temperature \u2014 directly accelerates cable insulation degradation. The study noted that in Chinese coal mines alone, more than 10 major cable-related accidents occurred between 2007 and 2014, resulting in more than 100 casualties. These statistics underscore why mining trailing cables are among the most heavily regulated and rigorously tested industrial products in the world.<\/p>\n\n    <p class=\"cn\">\u77ff\u7528\u62d6\u66f3\u7535\u7f06\u662f\u4e13\u4e3a\u5728\u79fb\u52a8\u91c7\u77ff\u673a\u68b0\u540e\u65b9\u5730\u9762\u62d6\u62fd\u800c\u8bbe\u8ba1\u7684\u91cd\u578b\u67d4\u6027\u7535\u529b\u7535\u7f06\u3002\u4e0e\u56fa\u5b9a\u5b89\u88c5\u540e\u9759\u6b62\u4e0d\u52a8\u7684\u7535\u7f06\u4e0d\u540c\uff0c\u62d6\u66f3\u7535\u7f06\u968f\u5176\u4f9b\u7535\u7684\u8bbe\u5907\u6301\u7eed\u79fb\u52a8\u2014\u2014\u88ab\u62c9\u62fd\u3001\u5f2f\u66f2\u3001\u78be\u538b\uff0c\u627f\u53d7\u5730\u4e0b\u548c\u9732\u5929\u77ff\u5c71\u73af\u5883\u65bd\u52a0\u7684\u5168\u90e8\u673a\u68b0\u548c\u5316\u5b66\u4fb5\u8680\u3002\u7535\u7f06\u5fc5\u987b\u5728\u627f\u53d7\u8fd9\u79cd\u6301\u7eed\u7269\u7406\u6467\u6b8b\u7684\u540c\u65f6\u53ef\u9760\u8f93\u9001\u7535\u529b\uff0c\u5e76\u6ee1\u8db3\u6f5c\u5728\u7206\u70b8\u6027\u5927\u6c14\u4e2d\u963b\u71c3\u548c\u63a5\u5730\u6545\u969c\u76d1\u6d4b\u7684\u4e25\u683c\u5b89\u5168\u8981\u6c42\u3002PMC \u53d1\u8868\u7684\u7814\u7a76\u8868\u660e\uff0c2007-2014\u5e74\u95f4\u4ec5\u4e2d\u56fd\u7164\u77ff\u5c31\u53d1\u751f\u4e8610\u4f59\u8d77\u7535\u7f06\u76f8\u5173\u91cd\u5927\u4e8b\u6545\uff0c\u9020\u6210100\u4f59\u4eba\u4f24\u4ea1\u2014\u2014\u8fd9\u8bf4\u660e\u4e86\u77ff\u7528\u62d6\u66f3\u7535\u7f06\u4e3a\u4f55\u662f\u4e16\u754c\u4e0a\u76d1\u7ba1\u6700\u4e25\u683c\u3001\u6d4b\u8bd5\u6700\u4e25\u82db\u7684\u5de5\u4e1a\u4ea7\u54c1\u4e4b\u4e00\u3002<\/p>\n\n\n    <h2 id=\"s2\">2. How Is a Mining Trailing Cable Constructed? Layer-by-Layer Analysis<\/h2>\n\n    <p>A modern mining trailing cable is a multi-layer engineered structure where each layer serves a specific functional purpose. Understanding the construction from center to outer surface reveals why these cables are significantly more complex \u2014 and more expensive \u2014 than standard power cables of equivalent voltage and conductor size.<\/p>\n\n    <h3>Layer 1 \u2014 Central Pilot (Ground-Check) Conductor<\/h3>\n\n    <p>At the geometric center of the cable sits a small-gauge conductor (typically 10\u201316 AWG in North American constructions, or 1.5\u201316mm\u00b2 in metric constructions) insulated with EPR or silicone rubber. This pilot conductor carries a low-voltage monitoring signal \u2014 typically 10\u201320V DC \u2014 from the earth-fault monitoring relay. Its central position provides maximum physical protection from external damage. If the pilot circuit is interrupted (indicating cable damage or cut), the monitoring relay immediately trips the power circuit, de-energizing the cable before a hazardous condition develops. In AS\/NZS 1802 constructions, the pilot is often an extensible design \u2014 manufactured with extra length built into the lay \u2014 so that if the cable is stretched under tension, the pilot conductor stretches without breaking, maintaining the safety monitoring circuit under mechanical stress conditions that might fracture a standard conductor.<\/p>\n\n    <h3>Layer 2 \u2014 Earth (Ground) Conductors<\/h3>\n\n    <p>Surrounding the central pilot are earth conductors \u2014 typically three, positioned in the interstices between the power cores. Each earth conductor is individually insulated (green\/yellow or green per regional color coding). Three-earth-conductor architecture provides redundancy: if one earth core is mechanically damaged, the remaining two continue to provide a low-impedance fault return path. The combined cross-section of the earth conductors is specified by standards to carry the full fault current for the time required for protective devices to operate \u2014 typically rated at 50% of the power conductor cross-section for cables 6 AWG and larger per ICEA S-75-381, or as specified in AS\/NZS 1802 tables. Earth conductors are tinned copper in most modern constructions to prevent oxidation at termination points.<\/p>\n\n    <h3>Layer 3 \u2014 Power Conductors (Phase Conductors)<\/h3>\n\n    <p>Three power conductors carry the three-phase AC power supply. Each conductor is stranded from multiple fine copper wires in rope-lay flexible construction \u2014 Class B or Class C stranding per ASTM B172\/B174 in North American constructions, or Class 5 per IEC 60228 in metric constructions. The fine-wire stranding provides the flexibility needed for trailing service while maintaining current-carrying capacity. Conductor sizes range from 6 AWG (16mm\u00b2) for auxiliary equipment up to 500 kcmil (240mm\u00b2) or larger for high-capacity mining shovels. Each power conductor is insulated with EPR or XLPE (discussed in Section 3) to the appropriate thickness for its voltage rating.<\/p>\n\n    <h3>Layer 4 \u2014 Semiconductive Screens<\/h3>\n\n    <p>In medium-voltage trailing cables (above 2kV), each power core is surrounded by a semiconductive screen \u2014 either a bonded semiconductive elastomer layer or a composite construction of copper tape\/braid over a semiconductive layer. The screen provides uniform electrical field distribution around the conductor, preventing field concentration at surface irregularities that would initiate partial discharge and eventual insulation breakdown. In AS\/NZS 1802 constructions, two screen types are defined: &#8220;composite&#8221; screens (copper\/polyester braid over semiconductive layer) and &#8220;semiconductive&#8221; screens (bonded semiconductive elastomer without metallic component). The screen type affects cable flexibility, fault current capacity, and cost.<\/p>\n\n    <h3>Layer 5 \u2014 Core Assembly and Filling<\/h3>\n\n    <p>The screened power cores, earth conductors, and central pilot are assembled together with elastomeric fillers that fill the interstices between cores, maintaining the cable&#8217;s circular cross-section and preventing core movement during bending. In tropicalized constructions, swellable water-blocking yarns are wound between cores to prevent capillary water migration from sheath breach points. A semiconductive bedding layer or binding tape may be applied over the assembled core to provide a uniform surface for the inner sheath.<\/p>\n\n    <h3>Layer 6 \u2014 Inner Sheath (Bedding)<\/h3>\n\n    <p>An inner sheath of PCP (polychloroprene) or equivalent elastomer provides a thermal and mechanical barrier between the core assembly and the outer sheath. This layer distributes external mechanical forces more uniformly across the cable structure, preventing localized stress concentration on individual cores. In some constructions, a reinforcement layer \u2014 open nylon braid or textile wrapping \u2014 is incorporated between the inner and outer sheaths to enhance tensile strength and torsional resistance.<\/p>\n\n    <h3>Layer 7 \u2014 Outer Sheath (Jacket)<\/h3>\n\n    <p>The outermost layer is the cable&#8217;s primary defense against the mining environment. The outer sheath is typically 3.5\u20136.0mm thick \u2014 substantially thicker than reeling cable sheaths \u2014 and is formulated from heavy-duty CPE (chlorinated polyethylene), PCP (polychloroprene), or in specialized applications, PUR (polyurethane). The sheath must resist grinding abrasion from continuous ground contact, survive crushing from multi-tonne mining equipment, resist cutting from sharp rock and metal edges, maintain integrity after impact from falling objects, provide flame retardancy per MSHA, AS\/NZS, or IEC requirements, and resist chemical attack from mine water, oils, and fuels. The sheath color \u2014 typically black, but orange, yellow, or red in some constructions \u2014 provides visibility in dark mining environments and may indicate voltage rating per regional color-coding conventions.<\/p>\n\n    <span class=\"eq\">Mining Trailing Cable Construction (Center \u2192 Outside):<br>Pilot Conductor \u2192 Earth Conductors \u2192 Power Cores (with EPR\/XLPE insulation) \u2192 Semiconductive Screens \u2192 Core Assembly Fill \u2192 Inner Sheath \u2192 Outer Sheath (CPE\/PCP\/PUR)<\/span>\n\n\n    <h2 id=\"s3\">3. What Insulation Materials Are Used? EPR vs XLPE<\/h2>\n\n    <p><strong>Ethylene Propylene Rubber (EPR)<\/strong> is the dominant insulation material for mining trailing cables worldwide. EPR provides a combination of properties uniquely suited to the trailing cable application: excellent flexibility that allows the cable to bend during trailing service without insulation cracking, good dielectric properties at medium voltages (3.3kV\u201315kV), superior resistance to water treeing compared to XLPE \u2014 a critical advantage in wet mining environments \u2014 thermal stability to 90\u00b0C continuous conductor temperature with 250\u00b0C short-circuit capability, and compatibility with both peroxide and silane cross-linking processes.<\/p>\n\n    <p>As noted by Filipino Engineer, a technical reference for Asian electrical engineering, EPR&#8217;s advantages over XLPE include extra flexibility, reduced thermal expansion, and low sensitivity to water treeing. These properties make EPR the preferred choice for dynamic mining applications where cables must flex during operation. The trade-off is that EPR has higher dielectric losses than XLPE \u2014 but at the medium voltages typical of mining trailing cables (3.3kV\u201311kV), this dielectric loss is negligible in lifecycle cost analysis.<\/p>\n\n    <p><strong>Cross-linked Polyethylene (XLPE)<\/strong> is used in some mine power feeder cables (particularly Type MP-GC in North American constructions) where the cable is more stationary and flexibility is less critical than in trailing service. XLPE offers lower dielectric losses, higher voltage capability, and lower cost than EPR, but its greater stiffness and higher sensitivity to water treeing make it less suitable for the dynamic, wet-environment service that trailing cables experience.<\/p>\n\n    <div class=\"tw\">\n      <caption>Table 1 \u2014 EPR vs XLPE Insulation: Properties Comparison for Mining Trailing Cables<\/caption>\n      <table>\n        <thead><tr><th>Property<\/th><th>EPR<\/th><th>XLPE<\/th><th>Significance for Trailing Cables<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Flexibility<\/td><td class=\"g\">Excellent<\/td><td>Good<\/td><td>EPR preferred for cables that must flex during trailing service<\/td><\/tr>\n          <tr><td>Water Treeing Resistance<\/td><td class=\"g\">Superior<\/td><td>Moderate<\/td><td>Critical in wet mining environments; EPR advantage is significant<\/td><\/tr>\n          <tr><td>Dielectric Loss<\/td><td>Higher<\/td><td class=\"g\">Lower<\/td><td>Negligible at mining voltages (\u226415kV); favors XLPE at HV only<\/td><\/tr>\n          <tr><td>Thermal Expansion<\/td><td class=\"g\">Lower<\/td><td>Higher<\/td><td>Lower expansion reduces stress at terminations during load cycling<\/td><\/tr>\n          <tr><td>Max Continuous Temperature<\/td><td>90\u00b0C<\/td><td>90\u00b0C<\/td><td>Equal; both suitable for mining duty cycles<\/td><\/tr>\n          <tr><td>Short-Circuit Temperature<\/td><td>250\u00b0C<\/td><td>250\u00b0C<\/td><td>Equal; both meet mining protection requirements<\/td><\/tr>\n          <tr><td>Chemical Resistance<\/td><td>Good (acids, alkalis)<\/td><td class=\"g\">Good (oils, chemicals)<\/td><td>Both adequate; EPR better for mine water, XLPE better for oils<\/td><\/tr>\n          <tr><td>Cost<\/td><td class=\"r\">Higher<\/td><td class=\"g\">Lower<\/td><td>EPR premium justified by flexibility and water treeing advantages<\/td><\/tr>\n          <tr><td>Typical Application<\/td><td class=\"g\">Trailing cables (all types)<\/td><td>Power feeder cables (Type MP-GC)<\/td><td>EPR dominates trailing service; XLPE for semi-static feeders<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p class=\"cn\">EPR\uff08\u4e59\u4e19\u6a61\u80f6\uff09\u51ed\u501f\u5176\u5728\u67d4\u97e7\u6027\u3001\u6297\u6c34\u6811\u679d\u548c\u4f4e\u70ed\u81a8\u80c0\u65b9\u9762\u7684\u7efc\u5408\u4f18\u52bf\uff0c\u6210\u4e3a\u5168\u7403\u77ff\u7528\u62d6\u66f3\u7535\u7f06\u7684\u4e3b\u5bfc\u7edd\u7f18\u6750\u6599\u3002XLPE\u5728\u4ecb\u7535\u635f\u8017\u548c\u6210\u672c\u65b9\u9762\u6709\u4f18\u52bf\uff0c\u4f46\u5176\u8f83\u5927\u7684\u521a\u6027\u548c\u5bf9\u6c34\u6811\u679d\u7684\u654f\u611f\u6027\u4f7f\u5176\u4e0d\u592a\u9002\u5408\u62d6\u66f3\u7535\u7f06\u7684\u52a8\u6001\u6e7f\u73af\u5883\u5de5\u51b5\u3002\u5728 3.3\u201315kV \u7684\u77ff\u7528\u7535\u538b\u8303\u56f4\u5185\uff0cEPR \u7684\u4ecb\u7535\u635f\u8017\u52a3\u52bf\u53ef\u4ee5\u5ffd\u7565\u4e0d\u8ba1\u3002<\/p>\n\n\n    <h2 id=\"s4\">4. What Sheath Materials Are Used? CPE vs PCP vs PUR<\/h2>\n\n    <p>The outer sheath is the single most important component for determining a trailing cable&#8217;s service life in the field. It is the first layer to contact the operating environment and must absorb the continuous mechanical and chemical abuse of mining service without compromising internal cable integrity.<\/p>\n\n    <div class=\"tw\">\n      <caption>Table 2 \u2014 Sheath Material Comparison for Mining Trailing Cables<\/caption>\n      <table>\n        <thead><tr><th>Property<\/th><th>CPE (Chlorinated PE)<\/th><th>PCP (Polychloroprene)<\/th><th>PUR (Polyurethane)<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Primary Strength<\/td><td class=\"g\">Crush + abrasion resistance<\/td><td>General toughness + flame retardancy<\/td><td class=\"g\">Extreme abrasion + cold flexibility<\/td><\/tr>\n          <tr><td>Flame Retardancy<\/td><td class=\"g\">Excellent (inherent Cl)<\/td><td class=\"g\">Excellent (inherent Cl)<\/td><td>Good (with additives)<\/td><\/tr>\n          <tr><td>Abrasion Resistance<\/td><td class=\"g\">Excellent<\/td><td>Good<\/td><td class=\"g\">Excellent<\/td><\/tr>\n          <tr><td>Crush Resistance<\/td><td class=\"g\">Excellent<\/td><td>Good<\/td><td>Good<\/td><\/tr>\n          <tr><td>Water Absorption<\/td><td class=\"g\">Low (0.5\u20131.5%)<\/td><td class=\"r\">Higher (2\u20134%)<\/td><td class=\"g\">Low<\/td><\/tr>\n          <tr><td>Acid Resistance<\/td><td class=\"g\">Good (to pH 2.5)<\/td><td>Moderate<\/td><td>Moderate<\/td><\/tr>\n          <tr><td>Oil Resistance<\/td><td>Good<\/td><td>Good<\/td><td class=\"g\">Excellent<\/td><\/tr>\n          <tr><td>Cold Flexibility<\/td><td>Good (to \u221240\u00b0C)<\/td><td>Good (to \u221240\u00b0C)<\/td><td class=\"g\">Excellent (to \u221250\u00b0C)<\/td><\/tr>\n          <tr><td>Fungal Resistance<\/td><td class=\"g\">Good (with additives)<\/td><td class=\"r\">Poor (susceptible)<\/td><td>Good<\/td><\/tr>\n          <tr><td>Typical Application<\/td><td>Most trailing cables<\/td><td>Traditional underground cables<\/td><td>Extreme cold \/ extreme abrasion<\/td><\/tr>\n          <tr><td>Typical Thickness<\/td><td>3.5 \u2013 5.0 mm<\/td><td>3.5 \u2013 5.0 mm<\/td><td>3.0 \u2013 4.5 mm<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p><strong>CPE (Chlorinated Polyethylene)<\/strong> has become the dominant sheath material for modern mining trailing cables, replacing PCP in many applications. CPE&#8217;s chlorine content provides inherent flame retardancy without requiring additional flame-retardant additives. Its lower water absorption (0.5\u20131.5% compared to 2\u20134% for PCP) provides superior moisture protection in wet mining environments. CPE also offers better resistance to acidic mine water \u2014 a critical advantage in coal mines where pyritic sulfur content creates acidic groundwater with pH as low as 2.5\u20133.5.<\/p>\n\n    <p><strong>PCP (Polychloroprene\/Neoprene)<\/strong> was the traditional sheath material for mining cables and remains in use for certain applications. PCP provides good general toughness and flame retardancy but has higher water absorption than CPE, making it less suitable for sustained wet-environment service. PCP is also more susceptible to fungal colonization in tropical environments \u2014 a documented problem in Indonesian and Papua New Guinean mining operations where fungal organisms produce acidic metabolic byproducts that accelerate sheath degradation.<\/p>\n\n    <p><strong>PUR (Polyurethane)<\/strong> is used in specialized trailing cables for extreme cold environments (operational to \u221250\u00b0C) and for large surface mining equipment (shovels, draglines) where exceptional abrasion resistance is required. Feichun Cable&#8217;s TENAX-PUR product line uses PUR sheaths for 6\/10kV trailing cables that operate in open-pit mines from Siberia to the Atacama Desert. PUR&#8217;s superior tear resistance and oil resistance make it ideal for surface mining where cables contact hydraulic fluid and diesel fuel spillage.<\/p>\n\n\n    <h2 id=\"s5\">5. What Are the Cable Types? Classification by Standard<\/h2>\n\n    <h3>North American Classification (ICEA S-75-381 \/ NEMA WC 58)<\/h3>\n\n    <div class=\"tw\">\n      <caption>Table 3 \u2014 North American Mining Trailing Cable Types<\/caption>\n      <table>\n        <thead><tr><th>Type<\/th><th>Description<\/th><th>Voltage<\/th><th>Key Features<\/th><th>Typical Application<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Type W<\/td><td>Portable power, round<\/td><td>2,000V<\/td><td>EPR\/CPE; no ground-check; 2\u20135 conductors<\/td><td>DC equipment, pumps, fans, drills<\/td><\/tr>\n          <tr><td>Type G-GC<\/td><td>Portable with ground-check<\/td><td>2,000V<\/td><td>EPR\/CPE; includes ground-check conductor<\/td><td>AC continuous miners, shuttle cars (low voltage)<\/td><\/tr>\n          <tr><td>Type SHD-GC<\/td><td>Shielded with ground-check<\/td><td>5\/8\/15\/25 kV<\/td><td>EPR\/CPE; individual core shielding; ground-check<\/td><td>Medium\/high-voltage continuous miners, shovels<\/td><\/tr>\n          <tr><td>Type MP-GC<\/td><td>Mine power feeder with ground-check<\/td><td>5\/8\/15\/25 kV<\/td><td>XLPE\/PVC or EPR\/CPE; for semi-static feeders<\/td><td>Power center to face, longwall power supply<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <h3>Australian \/ New Zealand Classification (AS\/NZS 1802:2003)<\/h3>\n\n    <div class=\"tw\">\n      <caption>Table 4 \u2014 AS\/NZS 1802 Mining Trailing Cable Types<\/caption>\n      <table>\n        <thead><tr><th>Type<\/th><th>Voltage Range<\/th><th>Screen Type<\/th><th>Application<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Type 240<\/td><td>1.1kV \u2013 11kV<\/td><td>Composite (Cu\/polyester braid)<\/td><td>General trailing service \u2014 all mobile mining equipment<\/td><\/tr>\n          <tr><td>Type 241<\/td><td>1.1kV \u2013 11kV<\/td><td>Composite<\/td><td>Reeling service \u2014 equipment with cable drums<\/td><\/tr>\n          <tr><td>Type 245<\/td><td>1.1kV \u2013 11kV<\/td><td>Semiconductive (bonded elastomer)<\/td><td>General trailing service \u2014 alternative screen construction<\/td><\/tr>\n          <tr><td>Type 275<\/td><td>3.3\/3.3kV \u2013 6.6\/6.6kV<\/td><td>Composite or semiconductive<\/td><td>IT-earthed systems \u2014 Uo=U insulation requirement<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>The critical distinction in AS\/NZS 1802 is the Uo\/U voltage notation. In IT (isolated neutral) earthing systems \u2014 mandated in many Australian and New Zealand mining operations and adopted by Indonesian and PNG mines using Australian-designed equipment \u2014 a single earth fault causes phase-to-earth voltage to rise to the full phase-to-phase value. Cable insulation must be rated Uo = U, producing markings like &#8220;3.3\/3.3kV&#8221; instead of the European &#8220;3.6\/6kV.&#8221; This is not a cosmetic difference \u2014 it represents a fundamentally different insulation design and testing basis.<\/p>\n\n    <h3>European Classification (DIN VDE 0250)<\/h3>\n\n    <p>European mining trailing cables are designated by complex type codes such as (N)TSCGECWOEU, where each letter indicates a specific construction feature: N = national standard, T = trailing cable, SC = semiconductive screen, GE = earth conductor, CW = concentric winding, O = oil resistant, EU = European standard. DIN VDE 0250-813 specifically covers medium-voltage reeling and trailing cables for mining at 6\/10kV and 12\/20kV ratings.<\/p>\n\n\n    <h2 id=\"s6\">6. What Voltage Ratings Are Available?<\/h2>\n\n    <div class=\"tw\">\n      <caption>Table 5 \u2014 Mining Trailing Cable Voltage Ratings and Applications<\/caption>\n      <table>\n        <thead><tr><th>Voltage Class<\/th><th>Specific Ratings<\/th><th>Typical Equipment<\/th><th>Standard Reference<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Low Voltage<\/td><td>600V, 1,000V, 1.1\/1.1kV, 2,000V<\/td><td>Drill rigs, pumps, fans, auxiliary equipment, shuttle cars (some)<\/td><td>ICEA (Type W, Type G-GC); AS\/NZS 1802 (Type 240)<\/td><\/tr>\n          <tr><td>Medium Voltage<\/td><td>3.3\/3.3kV, 3.6\/6kV, 5kV, 6.6\/6.6kV<\/td><td>Continuous miners, shuttle cars, LHD machines, longwall equipment<\/td><td>ICEA (Type SHD-GC); AS\/NZS 1802 (Type 240, 275)<\/td><\/tr>\n          <tr><td>High Voltage<\/td><td>8kV, 10kV, 11kV, 15kV<\/td><td>Large mining shovels, excavators, rope shovels<\/td><td>ICEA (Type SHD-GC); AS\/NZS 1802 (Type 240)<\/td><\/tr>\n          <tr><td>Extra-High Voltage<\/td><td>22kV, 25kV<\/td><td>Very large draglines, walking draglines<\/td><td>DIN VDE 0250-813; custom specifications<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n\n    <h2 id=\"s7\">7. What Is the Ampacity of Mining Trailing Cables?<\/h2>\n\n    <p>Ampacity (current-carrying capacity) is not a fixed value \u2014 it depends on conductor size, insulation material, installation conditions, ambient temperature, and cable grouping. Standard ampacity tables for mining trailing cables assume a conductor temperature of 90\u00b0C and ambient air temperature of 40\u00b0C for cables run in free air, per ICEA S-75-381 or VDE 0298-4 methodology.<\/p>\n\n    <div class=\"tw\">\n      <caption>Table 6 \u2014 Typical Ampacity Values: EPR-Insulated Copper Mining Trailing Cables (90\u00b0C Conductor, 40\u00b0C Ambient, Free Air)<\/caption>\n      <table>\n        <thead><tr><th>Conductor Size (AWG \/ mm\u00b2)<\/th><th>Approx. Ampacity (A)<\/th><th>Notes<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>6 AWG \/ 16mm\u00b2<\/td><td>~85<\/td><td>Drills, small pumps, auxiliary equipment<\/td><\/tr>\n          <tr><td>4 AWG \/ 25mm\u00b2<\/td><td>~115<\/td><td>Medium-duty equipment<\/td><\/tr>\n          <tr><td>2 AWG \/ 35mm\u00b2<\/td><td>~145<\/td><td>Shuttle cars, roof bolters<\/td><\/tr>\n          <tr><td>1\/0 AWG \/ 50mm\u00b2<\/td><td>~195<\/td><td>Continuous miners (lower power)<\/td><\/tr>\n          <tr><td>2\/0 AWG \/ 70mm\u00b2<\/td><td>~225<\/td><td>Continuous miners, LHD machines<\/td><\/tr>\n          <tr><td>4\/0 AWG \/ 120mm\u00b2<\/td><td>~300<\/td><td>Large continuous miners, longwall equipment<\/td><\/tr>\n          <tr><td>350 kcmil \/ 185mm\u00b2<\/td><td>~385<\/td><td>Mining shovels, large equipment<\/td><\/tr>\n          <tr><td>500 kcmil \/ 240mm\u00b2<\/td><td>~470<\/td><td>Large shovels, draglines<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">Tropical Derating Warning<\/div>\n      <p>In Indonesian and Papua New Guinean mining environments where ambient temperatures reach 45\u201350\u00b0C, these ampacity values must be derated. The derating formula is: <strong>I<sub>derated<\/sub> = I<sub>base<\/sub> \u00d7 \u221a((90 \u2212 T<sub>ambient<\/sub>) \u00f7 (90 \u2212 40))<\/strong>. At 50\u00b0C ambient: derating factor = \u221a(40\u00f750) = 0.894. A cable rated 195A at 40\u00b0C carries only ~174A at 50\u00b0C ambient. Always use measured maximum site temperature, not seasonal averages, as the design basis.<\/p>\n    <\/div>\n\n\n    <h2 id=\"s8\">8. What Is a Ground-Check Conductor and Why Is It Required?<\/h2>\n\n    <p>The ground-check conductor (also called pilot conductor or monitoring conductor) is a safety-critical cable component mandated by mining regulations worldwide. Its function is deceptively simple but operationally essential: it provides continuous monitoring of cable integrity so that damage or faults are detected and the cable is de-energized before a hazardous condition develops.<\/p>\n\n    <p><strong>How it works:<\/strong> A low-voltage DC signal (typically 10\u201320V) is sent through the pilot conductor from the power center&#8217;s earth-fault monitoring relay. The relay continuously monitors this circuit for continuity and for earth-fault current. If the cable is cut (severing the pilot), if a ground fault develops (creating current flow through the pilot circuit), or if the grounding circuit is compromised, the relay detects the abnormality and trips the main power circuit breaker \u2014 de-energizing all power conductors within milliseconds.<\/p>\n\n    <p><strong>Regulatory mandate:<\/strong> In the United States, 30 CFR \u00a775.603 requires that trailing cables used in coal mines be equipped with ground-check conductors. MSHA (Mine Safety and Health Administration) enforces this requirement through regular inspections, and non-compliance can result in mine closure orders. AS\/NZS 1802 similarly requires pilot conductors in all trailing cable types. The pilot conductor is not optional \u2014 it is a regulatory requirement in every jurisdiction that governs underground mining electrical safety.<\/p>\n\n    <p><strong>Construction details:<\/strong> The pilot conductor is positioned at the cable&#8217;s geometric center for maximum physical protection. In AS\/NZS 1802 Type 275 cables, the pilot is an &#8220;extensible&#8221; design \u2014 manufactured with extra conductor length built into the helical lay \u2014 so that moderate cable stretching under tension does not break the pilot circuit. Typical pilot conductor size is 16mm\u00b2 (6 AWG) tinned copper, insulated with EPR rated for 110V.<\/p>\n\n\n    <h2 id=\"s9\">9. What Standards Govern Mining Trailing Cables?<\/h2>\n\n    <div class=\"tw\">\n      <caption>Table 7 \u2014 Mining Trailing Cable Standards by Jurisdiction<\/caption>\n      <table>\n        <thead><tr><th>Standard<\/th><th>Jurisdiction<\/th><th>Scope<\/th><th>Key Requirements<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>ICEA S-75-381 \/ NEMA WC 58<\/td><td>North America<\/td><td>Portable and power feeder cables for mines<\/td><td>Conductor (ASTM B172\/B174), insulation, shielding, jacket, flame test, cold bend\/impact at \u221250\u00b0C<\/td><\/tr>\n          <tr><td>AS\/NZS 1802:2003<\/td><td>Australia, NZ, influenced markets<\/td><td>Trailing cables for mining<\/td><td>Type 240\/241\/245\/275; EPR insulation; CPE\/PCP sheath; pilot conductor; flame per AS\/NZS 1660.5<\/td><\/tr>\n          <tr><td>DIN VDE 0250<\/td><td>Europe (Germany)<\/td><td>Flexible cables including mining<\/td><td>Part 813 for MV reeling\/trailing; construction, dimensions, testing<\/td><\/tr>\n          <tr><td>30 CFR Part 75 Subpart G<\/td><td>USA (MSHA)<\/td><td>Trailing cables in underground coal mines<\/td><td>Flame resistance, ground-check, short-circuit protection, splicing, clamping, handling<\/td><\/tr>\n          <tr><td>IEC 60502<\/td><td>International<\/td><td>Power cables with extruded insulation<\/td><td>General construction and testing; referenced by regional mining standards<\/td><\/tr>\n          <tr><td>IEC 60228<\/td><td>International<\/td><td>Conductor classification<\/td><td>Class 5 (flexible) and Class 6 (extra-flexible) definitions<\/td><\/tr>\n          <tr><td>IEC 60332-1<\/td><td>International<\/td><td>Flame retardancy testing<\/td><td>Single vertical cable flame propagation test<\/td><\/tr>\n          <tr><td>MT818-2009<\/td><td>China<\/td><td>Mining cable for coal mines<\/td><td>Chinese national standard for underground mining cables<\/td><\/tr>\n          <tr><td>SANS 1507<\/td><td>South Africa<\/td><td>Mining cables<\/td><td>SABS standard for South African mining operations<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p><strong>MSHA enforcement in the United States:<\/strong> The U.S. Mine Safety and Health Administration enforces 30 CFR Part 75, Subpart G (\u00a7\u00a775.600\u201375.607) which establishes mandatory safety standards specifically for trailing cables in underground coal mines. Key requirements include: all trailing cables must be flame-resistant and MSHA-accepted (\u00a775.600); short-circuit protection must be provided by automatic circuit breakers (\u00a775.601); trailing cables must be equipped with ground-check conductors (\u00a775.603); splices must be made mechanically strong, flame-resistant, and insulated to original cable quality (\u00a775.604); and trailing cables must be clamped to machines to prevent strain on electrical connections (\u00a775.605). Non-compliance citations are among the most common electrical violations in MSHA inspections.<\/p>\n\n\n    <h2 id=\"s10\">10. Which Mining Equipment Uses Trailing Cables?<\/h2>\n\n    <div class=\"tw\">\n      <caption>Table 8 \u2014 Equipment-to-Cable Type Compatibility Matrix<\/caption>\n      <table>\n        <thead><tr><th>Equipment<\/th><th>Typical Voltage<\/th><th>Cable Type (ICEA)<\/th><th>Cable Type (AS\/NZS)<\/th><th>Conductor Size<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Continuous Miner<\/td><td>2kV \u2013 4.16kV<\/td><td>Type SHD-GC<\/td><td>Type 275 (3.3\/3.3kV)<\/td><td>2\/0 \u2013 4\/0 AWG (70\u2013120mm\u00b2)<\/td><\/tr>\n          <tr><td>Shuttle Car<\/td><td>600V \u2013 2kV<\/td><td>Type G-GC \/ SHD-GC<\/td><td>Type 240 (1.1kV)<\/td><td>2 \u2013 2\/0 AWG (35\u201370mm\u00b2)<\/td><\/tr>\n          <tr><td>Load-Haul-Dump (LHD)<\/td><td>2kV \u2013 4.16kV<\/td><td>Type SHD-GC<\/td><td>Type 275 (3.3\/3.3kV)<\/td><td>1\/0 \u2013 4\/0 AWG (50\u2013120mm\u00b2)<\/td><\/tr>\n          <tr><td>Roof Bolter<\/td><td>600V \u2013 1kV<\/td><td>Type G-GC<\/td><td>Type 240 (1.1kV)<\/td><td>6 \u2013 2 AWG (16\u201335mm\u00b2)<\/td><\/tr>\n          <tr><td>Underground Drill Rig<\/td><td>600V \u2013 1kV<\/td><td>Type W \/ Type G-GC<\/td><td>Type 240 (1.1kV)<\/td><td>6 \u2013 4 AWG (16\u201325mm\u00b2)<\/td><\/tr>\n          <tr><td>Mining Shovel (Surface)<\/td><td>4.16kV \u2013 15kV<\/td><td>Type SHD-GC<\/td><td>Type 240 (6.6\u201311kV)<\/td><td>4\/0 \u2013 500 kcmil (120\u2013240mm\u00b2)<\/td><\/tr>\n          <tr><td>Dragline<\/td><td>7.2kV \u2013 25kV<\/td><td>Type SHD-GC \/ Custom<\/td><td>Type 240 (11kV) \/ Custom<\/td><td>350 \u2013 500+ kcmil (185\u2013240+mm\u00b2)<\/td><\/tr>\n          <tr><td>Tunnel Boring Machine<\/td><td>3.3kV \u2013 6.6kV<\/td><td>Type SHD-GC<\/td><td>Type 240 (3.3\u20136.6kV)<\/td><td>2\/0 \u2013 4\/0 AWG (70\u2013120mm\u00b2)<\/td><\/tr>\n          <tr><td>Mobile Conveyor<\/td><td>600V \u2013 3.3kV<\/td><td>Type G-GC \/ SHD-GC<\/td><td>Type 240 (1.1\u20133.3kV)<\/td><td>4 \u2013 1\/0 AWG (25\u201350mm\u00b2)<\/td><\/tr>\n          <tr><td>Longwall Equipment<\/td><td>2kV \u2013 4.16kV<\/td><td>Type SHD-GC \/ MP-GC<\/td><td>Type 275<\/td><td>2\/0 \u2013 4\/0 AWG (70\u2013120mm\u00b2)<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n\n    <h2 id=\"s11\">11. How Does a Trailing Cable Differ from a Reeling Cable?<\/h2>\n\n    <div class=\"note amber\">\n      <div class=\"nt\">Key Distinction<\/div>\n      <p><strong>If the cable is wound on a reel \u2192 Reeling Cable.<\/strong> If the cable drags on the ground behind a machine \u2192 <strong>Trailing Cable.<\/strong> They solve fundamentally different mechanical problems and cannot be interchanged.<\/p>\n    <\/div>\n\n    <div class=\"tw\">\n      <caption>Table 9 \u2014 Trailing Cable vs Reeling Cable: Engineering Comparison<\/caption>\n      <table>\n        <thead><tr><th>Feature<\/th><th>Trailing Cable<\/th><th>Reeling Cable<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Motion Type<\/td><td>Dragged on the ground<\/td><td>Wound\/unwound on a drum<\/td><\/tr>\n          <tr><td>Primary Stress<\/td><td class=\"g\">Abrasion, crushing, cutting, impact<\/td><td>Tension, torsion, dynamic bending<\/td><\/tr>\n          <tr><td>Sheath Material<\/td><td class=\"g\">CPE \/ PCP \u2014 very thick (3.5\u20136mm)<\/td><td>PUR \u2014 thinner (2\u20133mm), flexible<\/td><\/tr>\n          <tr><td>Strength Member<\/td><td>Not required<\/td><td class=\"g\">Aramid (Kevlar) central core<\/td><\/tr>\n          <tr><td>Anti-Torsion<\/td><td>Not required<\/td><td class=\"g\">Embedded synthetic braid<\/td><\/tr>\n          <tr><td>Bending Radius<\/td><td>8\u201312 \u00d7 D (larger)<\/td><td class=\"g\">6\u20138 \u00d7 D (smaller)<\/td><\/tr>\n          <tr><td>Flex Life<\/td><td>50,000\u2013100,000 cycles<\/td><td class=\"g\">1,000,000+ cycles<\/td><\/tr>\n          <tr><td>Crush Resistance<\/td><td class=\"g\">Very high<\/td><td>Moderate<\/td><\/tr>\n          <tr><td>Primary Standard<\/td><td>AS\/NZS 1802, ICEA S-75-381<\/td><td>IEC 60502, DIN VDE 0250<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>Using a trailing cable on a reeling drum causes premature failure \u2014 the thick, stiff sheath resists bending, overstressing conductors that lack the ultra-fine stranding of reeling cables, and the absence of anti-torsion construction leads to Z-kinking within weeks. Conversely, using a reeling cable as a trailing cable in a mine destroys the thin PUR sheath within days through ground-contact abrasion \u2014 the sheath was designed for drum-surface contact, not rock-floor drag.<\/p>\n\n\n    <h2 id=\"s12\">12. What Are the Mechanical Requirements for Trailing Service?<\/h2>\n\n    <p><strong>Tensile strength:<\/strong> Trailing cables must withstand the pulling forces generated when the machine advances and drags the cable. Unlike reeling cables (where tension is controlled by the drum drive), trailing cable tension is irregular \u2014 sudden jerks occur when the cable snags on obstacles, and sustained pulling loads develop on long cable runs. The cable sheath and internal structure must distribute these forces without transferring damaging loads to the conductors.<\/p>\n\n    <p><strong>Crush resistance:<\/strong> Mining equipment routinely drives over trailing cables \u2014 shuttle cars, haul trucks, LHD machines, and even continuous miners may cross their own trailing cable during repositioning. The cable must survive these crossover events without conductor deformation or insulation compression that would compromise electrical integrity. This requirement drives the thick sheath specification (3.5\u20136.0mm) and the selection of high-crush-resistance sheath compounds.<\/p>\n\n    <p><strong>Impact resistance:<\/strong> Roof falls in underground mines can drop hundreds of kilograms of rock onto the cable. Falling tools, equipment components, and material handling accidents create additional impact hazards. The cable must absorb impact energy without sheath rupture. ICEA S-75-381 specifies cold impact testing at \u221250\u00b0C \u2014 the cable must survive impact at extreme low temperatures without cracking.<\/p>\n\n    <p><strong>Flame retardancy:<\/strong> Mining trailing cables must be flame-retardant and self-extinguishing \u2014 a fire in an underground mine with limited ventilation and potential methane accumulation is catastrophic. MSHA requires all trailing cables to pass flame-resistance testing and be MSHA-accepted. AS\/NZS 1660.5 requires a limited oxygen index (LOI) of at least 28% for underground mining cables. These requirements influence both sheath and insulation compound selection \u2014 CPE&#8217;s inherent chlorine content contributes to flame retardancy without requiring additional additives that might compromise mechanical properties.<\/p>\n\n\n    <h2 id=\"s13\">13. What Happens in Tropical Mining Environments?<\/h2>\n\n    <p>Indonesia, Papua New Guinea, Philippines, Central Africa, and South America represent the fastest-growing mining regions \u2014 and all share tropical or equatorial climates that dramatically accelerate cable degradation through three specific mechanisms that standard temperate-climate cable specifications do not address.<\/p>\n\n    <p><strong>Hydrolysis<\/strong> attacks EPR insulation: water molecules break polymer chains, reducing dielectric strength. The rate doubles every 10\u00b0C. At 40\u201350\u00b0C Indonesian ambient (versus 12\u201320\u00b0C Australian underground), the hydrolysis rate is 3\u20135\u00d7 faster.<\/p>\n\n    <p><strong>Water treeing<\/strong> grows microscopic moisture channels through insulation under voltage stress. In mines where cables are dragged through standing water and humidity exceeds 85% year-round, the moisture supply for tree propagation is unlimited.<\/p>\n\n    <p><strong>Copper oxidation<\/strong> causes contact resistance at terminations. In tropical humidity, bare copper darkens to copper oxide within weeks, creating semiconductive surface layers that cause localized overheating.<\/p>\n\n    <p><strong>The tropicalization solution:<\/strong> Feichun Cable&#8217;s tropicalized Type 275 addresses each mechanism with specific engineering features: tinned copper conductors (defeats oxidation), hydrolysis-resistant silane-crosslinked EPR (defeats hydrolysis, retaining &gt;90% dielectric strength after 1,000h water immersion at 90\u00b0C versus 60\u201370% for standard EPR), swellable water-blocking fill (defeats capillary water migration), and ultra-low-absorption CPE sheath with anti-fungal additives (&lt;0.5% water uptake versus 2\u20134% for standard PCP).<\/p>\n\n    <div class=\"note green\">\n      <div class=\"nt\">Field Evidence<\/div>\n      <p>At Papua New Guinea&#8217;s Lihir Gold Mine, a standard Type 275 cable reached near-failure (2 M\u03a9\u00b7km insulation resistance) after 14 months. A Feichun tropicalized cable at the same site maintained &gt;100 M\u03a9\u00b7km after 36 months. Service life improvement: 2\u20133\u00d7 for a cost premium of only 12\u201318%.<\/p>\n    <\/div>\n\n\n    <h2 id=\"s14\">14. How to Select the Right Mining Trailing Cable<\/h2>\n\n    <div class=\"note blue\">\n      <div class=\"nt\">Selection Checklist<\/div>\n      <p><strong>Step 1 \u2014 Voltage:<\/strong> Match cable Uo\/U rating to the mine&#8217;s distribution voltage and earthing system. For IT systems: Uo must equal U (e.g., 3.3\/3.3kV). For solidly-grounded: standard Uo\/U notation applies.<\/p>\n      <p><strong>Step 2 \u2014 Conductor size:<\/strong> Calculate required ampacity including derating for actual ambient temperature. Select conductor size from manufacturer tables with appropriate safety margin.<\/p>\n      <p><strong>Step 3 \u2014 Standard:<\/strong> Identify which standard governs your operation \u2014 AS\/NZS 1802, ICEA S-75-381, DIN VDE 0250, or national equivalent. This determines cable type designation and construction requirements.<\/p>\n      <p><strong>Step 4 \u2014 Environment:<\/strong> Assess specific environmental threats \u2014 tropical humidity, acidic mine water, extreme cold, UV exposure, biological activity. Specify tropicalization package if operating in equatorial or high-humidity environments.<\/p>\n      <p><strong>Step 5 \u2014 Equipment compatibility:<\/strong> Verify cable outer diameter, weight, and connector compatibility with the specific equipment&#8217;s cable handling system, reel dimensions (if applicable), and termination hardware.<\/p>\n      <p><strong>Step 6 \u2014 Sheath marking:<\/strong> Ensure sheath printing includes correct Uo\/U notation, cable type, conductor configuration, and manufacturer identification per applicable standard \u2014 site inspectors verify this marking during compliance audits.<\/p>\n    <\/div>\n\n\n    <h2 id=\"s15\">15. Feichun Cable Mining Trailing Cable Products<\/h2>\n\n    <div class=\"tw\">\n      <caption>Table 10 \u2014 Feichun Cable Trailing Cable Product Range<\/caption>\n      <table>\n        <thead><tr><th>Product<\/th><th>Standard<\/th><th>Voltage<\/th><th>Conductor Range<\/th><th>Key Feature<\/th><\/tr><\/thead>\n        <tbody>\n          <tr><td>Type 240<\/td><td>AS\/NZS 1802<\/td><td>1.1kV \u2013 11kV<\/td><td>6mm\u00b2 \u2013 150mm\u00b2<\/td><td>EPR insulation, composite screen, HD elastomer sheath<\/td><\/tr>\n          <tr><td>Type 275 Standard<\/td><td>AS\/NZS 1802<\/td><td>3.3\/3.3kV \u2013 6.6\/6.6kV<\/td><td>16mm\u00b2 \u2013 95mm\u00b2<\/td><td>IT-earthed systems; Uo=U insulation<\/td><\/tr>\n          <tr><td>Type 275 Tropicalized<\/td><td>AS\/NZS 1802<\/td><td class=\"g\">3.3\/3.3kV<\/td><td class=\"g\">25mm\u00b2 \u2013 70mm\u00b2<\/td><td class=\"g\">5-feature tropicalization for Indonesia\/PNG<\/td><\/tr>\n          <tr><td>TENAX-PUR<\/td><td>DIN VDE 0250<\/td><td>6\/10kV<\/td><td>50mm\u00b2 \u2013 185mm\u00b2<\/td><td>PUR sheath for \u221250\u00b0C; luminous option<\/td><\/tr>\n          <tr><td>Type SHD-GC Equivalent<\/td><td>ICEA S-75-381<\/td><td>5kV \u2013 15kV<\/td><td>2 AWG \u2013 4\/0 AWG<\/td><td>EPR\/CPE for North American mining operations<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/div>\n\n    <p>For cable selection assistance, contact Feichun Cable&#8217;s engineering team with your equipment model, operating voltage, earthing system type, and environmental conditions for a specific product recommendation.<\/p>\n\n\n    <h2 id=\"s16\">16. References and Further Reading<\/h2>\n    <p style=\"font-size:.82rem;color:var(--c-tertiary);margin-bottom:1rem;\">The following sources were referenced in the preparation of this guide.<\/p>\n\n    <h3 style=\"font-weight:600;font-size:.92rem;color:var(--c-body);margin:1.4rem 0 .6rem;\">Academic and Research Publications<\/h3>\n    <ol style=\"list-style:none;padding:0;font-size:.82rem;color:var(--c-secondary);line-height:1.7;\">\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[1]<\/span> Wang, X., et al. (2022). &#8220;Insulation Monitoring Technology of HV Cables in Underground Coal Mines.&#8221; <em>PMC\/Sensors<\/em>. <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC9152389\/\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">PMC9152389<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[2]<\/span> Liu, H., et al. (2022). &#8220;Comprehensive Operation Status Evaluation for Mining XLPE Cables.&#8221; <em>PMC\/Energies<\/em>. <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC9571771\/\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">PMC9571771<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[3]<\/span> MDPI. (2025). &#8220;Degradation Pathways of Electrical Cable Insulation.&#8221; <em>MDPI Fire<\/em>, 8(10). <a href=\"https:\/\/www.mdpi.com\/2571-6255\/8\/10\/397\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">mdpi.com<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[4]<\/span> Allen, N. S., et al. (1992). &#8220;Degradation of Silane- and Peroxide-Cross-linked PE and EPR.&#8221; <em>Polymer Degradation and Stability<\/em>. <a href=\"https:\/\/www.sciencedirect.com\/science\/article\/abs\/pii\/014139109290068G\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">ScienceDirect<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[5]<\/span> ELEK Software. (2025). &#8220;Estimating Cable Life Expectancy.&#8221; <a href=\"https:\/\/elek.com\/articles\/estimating-cable-life-expectancy\/\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">elek.com<\/a><\/li>\n    <\/ol>\n    <h3 style=\"font-weight:600;font-size:.92rem;color:var(--c-body);margin:1.4rem 0 .6rem;\">Standards and Regulations<\/h3>\n    <ol style=\"list-style:none;padding:0;font-size:.82rem;color:var(--c-secondary);line-height:1.7;\">\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[6]<\/span> ICEA S-75-381 \/ NEMA WC 58. &#8220;Portable and Power Feeder Cables for Use in Mines.&#8221;<\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[7]<\/span> AS\/NZS 1802:2003. &#8220;Electric Cables \u2014 Trailing Cables for Mining.&#8221; Standards Australia.<\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[8]<\/span> 30 CFR Part 75, Subpart G (\u00a7\u00a775.600\u201375.607). &#8220;Trailing Cables.&#8221; MSHA. <a href=\"https:\/\/www.ecfr.gov\/current\/title-30\/chapter-I\/subchapter-O\/part-75\/subpart-G\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">eCFR<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[9]<\/span> 30 CFR Part 75, Subpart I (\u00a7\u00a775.800\u201375.834). &#8220;Underground HV Distribution.&#8221; <a href=\"https:\/\/www.ecfr.gov\/current\/title-30\/chapter-I\/subchapter-O\/part-75\/subpart-I\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">eCFR<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[10]<\/span> DIN VDE 0250-813. &#8220;Medium Voltage Reeling and Trailing Cables for Mining.&#8221; VDE.<\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[11]<\/span> IEC 60502, IEC 60228, IEC 60332-1, IEC 60811. International Electrotechnical Commission.<\/li>\n    <\/ol>\n    <h3 style=\"font-weight:600;font-size:.92rem;color:var(--c-body);margin:1.4rem 0 .6rem;\">Industry and Manufacturer References<\/h3>\n    <ol style=\"list-style:none;padding:0;font-size:.82rem;color:var(--c-secondary);line-height:1.7;\">\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[12]<\/span> Business Research Insights. (2025). &#8220;Mining Cables Market \u2014 CAGR 2.2%.&#8221; <a href=\"https:\/\/www.businessresearchinsights.com\/market-reports\/mining-cables-market-102251\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">businessresearchinsights.com<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[13]<\/span> Prysmian Group Australia. (2018). &#8220;Cable Guide for the Mining Industry.&#8221; <a href=\"https:\/\/australia.prysmian.com\/sites\/australia.prysmian.com\/files\/media\/documents\/2018-mining-cables-guide_0.pdf\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">Prysmian (PDF)<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[14]<\/span> General Cable \/ Prysmian NA. (2014). &#8220;Anaconda Mining Cable Catalog.&#8221; <a href=\"https:\/\/na.prysmian.com\/sites\/na.prysmian.com\/files\/media\/documents\/INS-0044-R1014_Mining_Catalog_ENGLISH.pdf\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">Prysmian NA (PDF)<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[15]<\/span> Filipino Engineer. (2024). &#8220;XLPE vs EPR as Insulating Materials for HV Cables.&#8221; <a href=\"https:\/\/filipinoengineer.com\/blog\/2024\/07\/a-comparison-between-xlpe-and-epr-as-insulating-materials-for-hv-cables.html\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">filipinoengineer.com<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[16]<\/span> SAB Br\u00f6ckskes. &#8220;PUR Cables &#038; Wires: Features and Applications.&#8221; <a href=\"https:\/\/www.sab-cable.com\/cables-wires-harnessing-temperature-measurement\/technical-data\/cables-and-wires\/polyurethane-pur.html\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">sab-cable.com<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[17]<\/span> MSHA. &#8220;Electrical Handbook \/ Program Policy Manual Vol. V.&#8221; <a href=\"https:\/\/www.msha.gov\/program-policy-manual\/program-policy-manual-3\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">msha.gov<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[18]<\/span> MSHA. &#8220;Instantaneous Circuit Breaker Settings for Short Circuit Protection of Trailing Cables.&#8221; <a href=\"https:\/\/arlweb.msha.gov\/S&#038;HINFO\/TECHRPT\/ELECTRICAL\/INSTAN30.pdf\" style=\"color:var(--c-link);text-decoration:none;\" target=\"_blank\" rel=\"noopener\">MSHA Technical Report (PDF)<\/a><\/li>\n    <\/ol>\n    <h3 style=\"font-weight:600;font-size:.92rem;color:var(--c-body);margin:1.4rem 0 .6rem;\">Feichun Cable Technical Publications<\/h3>\n    <ol style=\"list-style:none;padding:0;font-size:.82rem;color:var(--c-secondary);line-height:1.7;\">\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[19]<\/span> Feichun Cable. (2025). &#8220;What Is Mining Trailing Cable?&#8221; <a href=\"https:\/\/feichuncables.com\/blog\/what-is-mining-trailing-cable\/\" style=\"color:var(--c-link);text-decoration:none;\">feichuncables.com\/blog<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[20]<\/span> Feichun Cable. (2026). &#8220;Type 275 3.3\/3.3kV for Indonesia.&#8221; <a href=\"https:\/\/feichuncables.com\/blog\/\" style=\"color:var(--c-link);text-decoration:none;\">feichuncables.com\/blog<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[21]<\/span> Feichun Cable. (2026). &#8220;PNG Gold Mines High-Humidity Specifications.&#8221; <a href=\"https:\/\/feichuncables.com\/blog\/papua-new-guinea-gold-mines-high-humidity-specifications-for-type-275-3-3-3-3kv-3x50mm\u00b2-reeling-cables\/\" style=\"color:var(--c-link);text-decoration:none;\">feichuncables.com\/blog (PNG)<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[22]<\/span> Feichun Cable. (2026). &#8220;TENAX-PUR 6\u201310kV Cable Specification.&#8221; <a href=\"https:\/\/feichuncables.com\/blog\/tenax-pur-ntscgeh3s-i-6-10-kv\/\" style=\"color:var(--c-link);text-decoration:none;\">feichuncables.com\/blog (TENAX-PUR)<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[23]<\/span> Feichun Cable. (2026). &#8220;Type 240 Mining Cable AS\/NZS 1802 Data Sheet.&#8221; <a href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/Type-240-Mining-Cable.pdf\" style=\"color:var(--c-link);text-decoration:none;\">feichuncables.com (PDF)<\/a><\/li>\n      <li style=\"margin-bottom:.5rem;padding-left:2rem;position:relative;\"><span style=\"position:absolute;left:0;font-weight:600;color:var(--c-tertiary);font-family:'IBM Plex Mono',monospace;font-size:.75rem;\">[24]<\/span> Feichun Cable. (2026). &#8220;Reeling Cable vs Trailing Cable: Complete Engineering Comparison.&#8221; <a href=\"https:\/\/feichuncables.com\/blog\/\" style=\"color:var(--c-link);text-decoration:none;\">feichuncables.com\/blog<\/a><\/li>\n    <\/ol>\n\n  <\/div>\n\n  <div class=\"contact\">\n    <h3>Contact Anhui Feichun Special Cable Co., Ltd. \u2014 Mining Trailing Cable Specialists<\/h3>\n    <div class=\"cg\">\n      <div class=\"ci\"><span class=\"lb\">Technical Engineering &#038; Cable Selection<\/span><a href=\"mailto:tech@feichuncables.com\">tech@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">International Sales &#038; Procurement<\/span><a href=\"mailto:sales@feichuncables.com\">sales@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Mining Industry Specialist<\/span><a href=\"mailto:mining@feichuncables.com\">mining@feichuncables.com<\/a><\/div>\n      <div class=\"ci\"><span class=\"lb\">Emergency Support \u2014 WhatsApp\/WeChat<\/span><a href=\"https:\/\/wa.me\/8613855123218\" target=\"_blank\" rel=\"noopener\">+86 138-5512-3218<\/a><\/div>\n    <\/div>\n  <\/div>\n\n  <footer class=\"ft\">\n    <p>&copy; 2026 Anhui Feichun Special Cable Co., Ltd. \u5b89\u5fbd\u98de\u7eaf\u7279\u79cd\u7535\u7f06\u6709\u9650\u516c\u53f8 \u2014 All rights reserved.<\/p>\n    <p>Building A, Private Science &#038; Technology Park, Hefei Economic and Technological Development Zone, Anhui Province, China.<\/p>\n    <p style=\"margin-top:.5rem;font-size:.7rem;\">This article is provided for informational and educational purposes. Always consult with qualified electrical engineers and follow applicable safety standards and regulations for your specific installation. IEC, AS\/NZS, DIN VDE, ICEA, ASTM, and MSHA are standards\/agencies of their respective organizations. PMC, MDPI, and ScienceDirect are academic publishing platforms cited for reference. All trademarks are properties of their respective owners. Last updated: March 10, 2026.<\/p>\n  <\/footer>\n\n<\/article>\n<\/body>\n<\/html>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/Feichun_AS_NZS_1802_AS_NZS_2802_Mining_Cable_Catalogue1-1.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u5d4c\u5165 Feichun_AS_NZS_1802_AS_NZS_2802_Mining_Cable_Catalogue(1)\"><\/object><a id=\"wp-block-file--media-bccc2ea4-cd35-4510-8bd7-753ad956ce7c\" href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/Feichun_AS_NZS_1802_AS_NZS_2802_Mining_Cable_Catalogue1-1.pdf\">Feichun_AS_NZS_1802_AS_NZS_2802_Mining_Cable_Catalogue(1)<\/a><a href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/Feichun_AS_NZS_1802_AS_NZS_2802_Mining_Cable_Catalogue1-1.pdf\" class=\"wp-block-file__button wp-element-button\" aria-describedby=\"wp-block-file--media-bccc2ea4-cd35-4510-8bd7-753ad956ce7c\" download>\u4e0b\u8f7d<\/a><\/div>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/NSHTOU-J-PUR-4G\u00d735-0.6_1-kV-\u2014-Anhui-Feichun-Special-Cable-Co.-Ltd_.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"\u5d4c\u5165 (N)SHTOU-J PUR 4G\u00d735-0.6_1 kV \u2014 Anhui Feichun Special Cable Co., Ltd_\"><\/object><a id=\"wp-block-file--media-3df0ea3f-b2ce-4f8c-8a69-c3bbfdaf8e91\" href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/NSHTOU-J-PUR-4G\u00d735-0.6_1-kV-\u2014-Anhui-Feichun-Special-Cable-Co.-Ltd_.pdf\">(N)SHTOU-J PUR 4G\u00d735-0.6_1 kV \u2014 Anhui Feichun Special Cable Co., Ltd_<\/a><a href=\"https:\/\/feichuncables.com\/blog\/wp-content\/uploads\/NSHTOU-J-PUR-4G\u00d735-0.6_1-kV-\u2014-Anhui-Feichun-Special-Cable-Co.-Ltd_.pdf\" class=\"wp-block-file__button wp-element-button\" aria-describedby=\"wp-block-file--media-3df0ea3f-b2ce-4f8c-8a69-c3bbfdaf8e91\" download>\u4e0b\u8f7d<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"What Is Mining Tra&hellip;","protected":false},"author":1,"featured_media":1362,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"csco_singular_sidebar":"left","csco_page_header_type":"title","csco_page_load_nextpost":"","footnotes":""},"class_list":["post-2281","page","type-page","status-publish","has-post-thumbnail","cs-entry"],"_links":{"self":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/pages\/2281","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/comments?post=2281"}],"version-history":[{"count":2,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/pages\/2281\/revisions"}],"predecessor-version":[{"id":8792,"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/pages\/2281\/revisions\/8792"}],"wp:attachment":[{"href":"https:\/\/feichuncables.com\/blog\/wp-json\/wp\/v2\/media?parent=2281"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}