PROTOLON高性能中压卷筒电缆 6-35千伏

PROTOLON (M)R-(N)TSCGEWOEU 6-35 KV
安徽飞纯特种电缆有限公司
Product Overview 产品概述
The PROTOLON (M)R-(N)TSCGEWOEU series represents a highly engineered family of medium voltage flexible reeling cables specifically designed for demanding applications in open-cast mining operations and heavy industrial environments. These cables are manufactured according to the stringent requirements of DIN VDE 0250-813 standard, which is recognized globally as the definitive specification for flexible trailing cables used in heavy industrial applications where extreme mechanical stresses are expected.
PROTOLON系列电缆专为露天矿山的大型物料搬运设备(如挖掘机、卸料车、移动式破碎机)设计,能够承受极高的机械应力,适用于单螺旋卷筒和圆柱形卷筒的灵活卷绕操作。
Applications 应用场合
These cables are engineered for connection of large material handling machines in open-cast mining operations, where equipment must maintain continuous power supply while subjected to high mechanical stresses, extreme temperature variations, and harsh environmental conditions. The primary applications include:
Excavators 挖掘机
Large-scale bucket-wheel excavators and walking draglines requiring cables capable of delivering megawatts of power while enduring continuous movement.
Dumpers 卸料车
Heavy-duty mobile dumpers and haul trucks in surface mining operations requiring reliable power transmission during constant reeling operations.
Mobile Crushers 移动式破碎机
Mobile crushing and screening equipment that requires flexible cable systems capable of withstanding dynamic stresses and frequent repositioning.
Material Handling Equipment 物料搬运设备
Stackers, reclaimers, and conveyor systems in mining and bulk material handling facilities requiring medium voltage power supply.
Standards & Approvals 标准与认证
- DIN VDE 0250-813 – General requirements for cables, wires and flexible cords for power installation; trailing cable specifications
- EN 50525-2-21 – Electrical parameters for flexible cables with rated voltages up to 450/750V
- DIN VDE 0207-21 – Compound specifications for insulation and sheathing materials
- DIN VDE 0298-3 – Mechanical parameters and installation requirements
- DIN EN 60811-404 / IEC 60811-404 – Chemical behaviour testing methods
- GOST-R/-K/-B – Fire Certificate of Certifications/Approvals from the Russian Federation
- DIN EN 60332-1-2 / IEC 60332-1-2 – Fire performance testing for flame propagation
Note: These cables are designed and tested according to internationally recognized standards to ensure reliable operation in the most demanding mining environments. Compliance with multiple standards provides assurance of quality and safety across different regulatory jurisdictions.
Technical Parameters 技术参数
Thermal Parameters 热参数
| Parameter 参数 | Value 数值 | Notes 备注 |
|---|---|---|
| Max. conductor temperature 最大导体温度 | 90°C | Normal operation 正常运行 |
| Max. conductor temperature at short circuit 短路时最大导体温度 | 250°C | Short-term condition 短时状态 |
| Ambient temperature fixed installation (min) 固定安装最低环境温度 | -40°C | Static application 静态应用 |
| Ambient temperature fixed installation (max) 固定安装最高环境温度 | 80°C | Static application 静态应用 |
| Ambient temperature flexible installation (min) 移动安装最低环境温度 | -30°C | Dynamic application 动态应用 |
| Ambient temperature flexible installation (max) 移动安装最高环境温度 | 80°C | Dynamic application 动态应用 |
Chemical Parameters 化学参数
| Property 性能 | Performance 表现 |
|---|---|
| Flame retardant 阻燃性 | In accordance with EN/IEC 60332-1-2 符合EN/IEC 60332-1-2标准 |
| Oil resistant 耐油性 | Yes 是 |
| Ozone resistance 耐臭氧性 | Yes 是 |
| Resistant to UV 抗紫外线 | Yes 是 |
| Sea water resistance 耐海水性 | Yes 是 |
Mechanical Parameters 机械参数
| Parameter 参数 | Value 数值 |
|---|---|
| Torsional stress 扭转应力 | +/- 100°/m |
| Permanent tensile strength (static) 永久抗拉强度(静态) | 20 N/mm² |
| Permanent tensile strength (dynamic) 永久抗拉强度(动态) | 25 N/mm² |
| Travel speed on rewinding 回卷速度 | Up to 100 m/min 最高100米/分钟 |
| Reeling operation speed 卷绕操作速度 | Up to 120 m/min 最高120米/分钟 |
| Bending radius (fixed installation) 弯曲半径(固定安装) | 6 × D (Acc. to VDE 0298-3) 根据VDE 0298-3标准 |
| Bending radius (flexible operation) 弯曲半径(移动操作) | 10 × D |
| Min distance with S-type directional changes S型换向最小距离 | 20 × D |
Cable Construction 电缆结构
The PROTOLON cable construction features a sophisticated multi-layer design optimized for extreme mechanical stresses and environmental conditions encountered in mining operations. Each layer is carefully engineered to provide specific protection and performance characteristics:
1. Conductor 导体
Very finely stranded copper, bare, class FS according to DIN VDE 0295. Provides maximum flexibility and conductivity for dynamic applications.
2. Inner Semi-conducting Layer 内半导电层
Semi-conductive EPR material ensures uniform electric field distribution around the conductor.
3. Core Insulation 芯线绝缘
EPR rubber PROTOLON Special compound 3GI3 – High grade material based on high-quality EPR with improved mechanical and electrical characteristics.
4. Three Core Design 三芯设计
With split earth conductor in three interstices providing enhanced safety and grounding performance.
5. Outer Semi-conducting Layer 外半导电层
Semi-conductive NBR easy-strip layer facilitates field termination and reduces installation time.
6. Split Earth Conductors 分裂接地导体
Very finely stranded copper positioned in cable interstices for optimal grounding.
7. Inner Sheath 内护套
Rubber – Special compound 5GM3 provides additional mechanical protection.
8. Armoring/Reinforcement 铠装/加强层
Braiding Material – Polyester provides tensile strength and mechanical protection.
9. Outer Sheath 外护套
Rubber – Polychloroprene (PCP), Special compound 5GM5 offers superior resistance to oil, ozone, UV radiation, and mechanical abrasion.
Electrical Parameters 电气参数
| Voltage Rating 额定电压 | U₀/U (Uₘ) | Test Voltage 试验电压 | Nominal Voltage U 标称电压 |
|---|---|---|---|
| 3.6/6 kV | 3.6/6 (7.2) kV | 11 kV | 6,000 V |
| 6/10 kV | 6/10 (12) kV | 17 kV | 10,000 V |
| 8.7/15 kV | 8.7/15 (17.5) kV | 24 kV | 15,000 V |
| 12/20 kV | 12/20 (24) kV | 29 kV | 20,000 V |
| 14/25 kV | 14/25 (29) kV | 36 kV | 25,000 V |
| 18/30 kV | 18/30 (36) kV | 43 kV | 30,000 V |
| 20/35 kV | 20/35 (42) kV | 50 kV | 35,000 V |
Cable Properties – Detailed Specifications 电缆性能详细规格
The following tables provide comprehensive technical specifications for various cable configurations across different voltage ratings. These specifications include conductor cross-sections, cable dimensions, weight, tensile strength, electrical capacitance, inductance, resistance, and current carrying capacity. All values are measured according to relevant international standards.
PROTOLON (M) R-(N)TSCGEWOEU 8.7/15KV
| Construction 构造 | Conductor Ø 导体直径 (mm) | Cable Ø (min) 电缆最小外径 (mm) | Cable Ø (max) 电缆最大外径 (mm) | Cable Weight 电缆重量 (kg/km) | Max. Tensile 最大抗拉强度 (N) | Capacitance 电容 (nF/km) | Inductance 电感 (mH/km) | Resistance 电阻 at 20°C (Ω/km) | Current 载流量 (A) |
|---|---|---|---|---|---|---|---|---|---|
| 3×25+3×25/3 | 7.1 | 41.4 | 44.4 | 2,700 | 1,500 | 340 | 0.26 | 0.7839 | 139 |
| 3×25+3×50/3 | 7.1 | 43.6 | 46.6 | 3,080 | 1,500 | 340 | 0.26 | 0.7839 | 139 |
| 3×50+3×25/3 | 10.1 | 44.1 | 47.1 | 3,890 | 3,000 | 330 | 0.31 | 0.386 | 215 |
| 3×70+3×35/3 | 11.8 | 52 | 56 | 5,010 | 4,200 | 380 | 0.3 | 0.272 | 265 |
| 3×95+3×50/3 | 13.8 | 56.2 | 60.2 | 6,300 | 5,700 | 410 | 0.29 | 0.206 | 319 |
| 3×120+3×70/3 | 15.5 | 61.3 | 65.3 | 7,580 | 7,200 | 450 | 0.28 | 0.161 | 371 |
| 3×185+3×95/3 | 19.2 | 69.1 | 73.1 | 10,280 | 11,100 | 540 | 0.26 | 0.106 | 488 |
| 3×240+3×120/3 | 22.1 | 76.6 | 80.6 | 13,110 | 14,400 | 600 | 0.26 | 0.0801 | 574 |
| 3×300+3×150/3 | 24.7 | 83.5 | 88.5 | 16,010 | 18,000 | 660 | 0.25 | 0.0641 | 660 |
PROTOLON (M) R-(N)TSCGEWOEU 12/20KV
| Construction 构造 | Conductor Ø 导体直径 (mm) | Cable Ø (min) 电缆最小外径 (mm) | Cable Ø (max) 电缆最大外径 (mm) | Cable Weight 电缆重量 (kg/km) | Max. Tensile 最大抗拉强度 (N) | Capacitance 电容 (nF/km) | Inductance 电感 (mH/km) | Resistance 电阻 at 20°C (Ω/km) | Current 载流量 (A) |
|---|---|---|---|---|---|---|---|---|---|
| 3×25+3×25/3 | 7.1 | 44.1 | 47.1 | 3,110 | 1,500 | 230 | 0.36 | 0.7839 | 139 |
| 3×50+3×25/3 | 10.1 | 51.3 | 55.3 | 4,490 | 3,000 | 290 | 0.32 | 0.386 | 215 |
| 3×70+3×35/3 | 11.8 | 55 | 59 | 5,360 | 4,200 | 330 | 0.31 | 0.272 | 265 |
| 3×95+3×50/3 | 13.8 | 61.8 | 65.8 | 6,800 | 5,700 | 370 | 0.3 | 0.206 | 319 |
| 3×120+3×70/3 | 15.5 | 64.2 | 68.2 | 7,980 | 7,200 | 400 | 0.29 | 0.161 | 371 |
| 3×185+3×95/3 | 19.2 | 73.4 | 77.4 | 10,990 | 11,100 | 480 | 0.27 | 0.106 | 488 |
| 3×240+3×120/3 | 22.1 | 78.3 | 82.3 | 14,200 | 14,400 | 540 | 0.26 | 0.0801 | 574 |
| 3×300+3×150/3 | 24.7 | 86.4 | 91.4 | 16,560 | 18,000 | 590 | 0.26 | 0.0641 | 660 |
PROTOLON (M) R-(N)TSCGEWOEU 18/30KV
| Construction 构造 | Conductor Ø 导体直径 (mm) | Cable Ø (min) 电缆最小外径 (mm) | Cable Ø (max) 电缆最大外径 (mm) | Cable Weight 电缆重量 (kg/km) | Max. Tensile 最大抗拉强度 (N) | Capacitance 电容 (nF/km) | Inductance 电感 (mH/km) | Resistance 电阻 at 20°C (Ω/km) | Current 载流量 (A) |
|---|---|---|---|---|---|---|---|---|---|
| 3×25+3×25/3 | 7.1 | 52.2 | 56.2 | 3,900 | 1,500 | 180 | 0.4 | 0.7839 | 139 |
| 3×50+3×25/3 | 10.1 | 58.6 | 62.6 | 5,250 | 3,000 | 220 | 0.36 | 0.386 | 215 |
| 3×70+3×35/3 | 11.8 | 62.5 | 66.5 | 6,500 | 4,200 | 240 | 0.34 | 0.272 | 265 |
| 3×95+3×50/3 | 13.8 | 67.9 | 71.9 | 8,160 | 5,700 | 270 | 0.33 | 0.206 | 319 |
| 3×120+3×70/3 | 15.5 | 72.8 | 76.8 | 9,630 | 7,200 | 290 | 0.31 | 0.161 | 371 |
| 3×185+3×95/3 | 19.2 | 80.6 | 84.6 | 12,170 | 11,100 | 340 | 0.3 | 0.106 | 488 |
| 3×240+3×120/3 | 22.1 | 88.1 | 93.1 | 15,280 | 14,400 | 380 | 0.28 | 0.0801 | 574 |
| 3×300+3×150/3 | 24.7 | 94.6 | 99.6 | 18,200 | 18,000 | 420 | 0.28 | 0.0641 | 660 |
Technical Advantages 技术优势
The PROTOLON cable system incorporates several advanced engineering features that distinguish it from conventional mining cables. According to research conducted on DIN VDE 0250 standard cables, these design elements significantly enhance performance and reliability in demanding applications.
High Flexibility 高柔韧性
The use of very finely stranded copper conductors (Class FS) combined with high-quality EPR insulation provides exceptional flexibility, enabling the cable to withstand continuous bending cycles on reeling drums without conductor fatigue or insulation cracking.
Superior Tensile Strength 卓越抗拉强度
Polyester braiding reinforcement provides tensile strength up to 30 N/mm², essential for supporting the cable’s own weight across spans that can exceed 100 meters in large mining equipment installations.
Enhanced Environmental Protection 增强环境保护
The polychloroprene (PCP) outer sheath delivers outstanding resistance to oil, ozone, UV radiation, and seawater, ensuring long service life in harsh mining environments where exposure to industrial fluids and extreme weather is common.
Optimized Electrical Performance 优化电气性能
The semi-conductive screening layers ensure uniform electric field distribution, reducing the risk of partial discharge and extending insulation life. Low capacitance values minimize charging currents and improve power factor.
Contact Information 联系方式
For technical inquiries, quotations, or custom cable solutions, please contact Anhui Feichun Special Cable Co., Ltd. through any of the following channels:
References & Standards 参考文献与标准
- VDE Verlag. “DIN VDE 0250-813:1985 – Cables, wires and flexible cords for power installation; trailing cable.” GlobalSpec Standards
- Feichun Cable. “What is DIN VDE 0250 Reeling Cables?” Technical Blog. November 2025. Feichun Cable Blog
- Prysmian Group. “Cable Solutions for the Mining Industry.” Product Catalog. Prysmian Mining Cables
- European Committee for Electrotechnical Standardization. “EN 50525-2-21:2011 – Electric cables – Low voltage energy cables of rated voltages up to and including 450/750 V.” CENELEC Standards.
- International Electrotechnical Commission. “IEC 60332-1-2 – Tests on electric and optical fibre cables under fire conditions – Part 1-2: Test for vertical flame propagation for a single insulated wire or cable.” IEC Standards Database.
- VDE Verlag. “DIN VDE 0298-3:2013-06 – Use of cables and flexible cords in power installations – Part 3: Recommended values for current-carrying capacity.” German Standards.
- International Electrotechnical Commission. “IEC 60811-404 – Electric and optical fibre cables – Test methods for non-metallic materials – Part 404: Miscellaneous tests – Thermal ageing methods – Ageing in an air oven.” IEC Standards.
- Eland Cables. “Mining Cables | Drilling & Tunnelling Cable.” Product Overview. Eland Mining Cables